Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time integrator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Aerosol measurements in the stratocumulus project

Cloud Condensation Nuclei (CCN) and Condensation Nuclei (CN) were measured from the National Center for Atmospheric Research (NCAR) Electra throughout the marine stratocumulus project. The total particle concentration was measured with a condensation nucleus counter. The CCN were measured with the Desert Research Institute (DRI) instantaneous CCN spectrometer. This instrument simultaneously measures the concentration of aerosol active at up to 100 different critical supersaturations (Sc). This is accomplished by exposing the sample to a fixed supersaturation field and using the size of the droplets produced in this cloud chamber to deduce the Sc of the nuclei upon which they have grown. Droplet size is associated with Sc through a calibration which is accomplished by passing soluble aerosols of known size and composition through the cloud chamber. This procedure results in a calibration curve of Sc vs. droplet size. This then allows the channel number to be directly associated with Sc. Thus, number concentration vs. Sc is obtained and this is a CCN spectrum. Since the instrument operates continuously, the measurements at all Sc's are available simultaneously. Samples are drawn directly from the ambient air and data is displayed in nearly real time. Samples were integrated over times of about 10 seconds so that substantial spatial resolution is available. Calibrations were performed once or twice a day and were found to be consistent. Preliminary results are shown.

Hudson, James G.↗

Flutter analysis of a supersonic cascade in time domain using an ADI Euler solver

The aeroelastic stability of a two-dimensional cascade oscillating in supersonic axial flow is analyzed in the time domain. The aeroelastic model consists of a single degree of freedom typical section structural model for each blade of the cascade and an unsteady two-dimensional cascade aerodynamic model based on the Euler equations. The Euler equations are solved using a time accurate Alternating Direction Implicit (ADI) solution scheme. The aeroelastic equations are integrated in time. The effect of interblade phase angle is included in the aeroelastic analysis by an appropriate choice of initial and boundary conditions. Flutter predictions are obtained from the time response of a flat plate cascade in single degree of freedom pitching motion. The results correlate well with those obtained from a separate frequency domain flutter analysis for all values of interblade phase angles considered. Flutter results are then presented for cascades having airfoil sections representative of a supersonic throughflow fan. The validity of the time integration method for a cascade of airfoils at various interblade phase angles is demonstrated.

Reddy, T. S. R.↗

Filovirus Research: The Need for an Integrated Approach in Time and Space

The episodic appearance of Ebola virus (EBOV) and Marburg virus (MARV) across central Africa over the last 15 years not only underscores the importance of filoviruses as uniquely virulent agents to both human and wildlife communities but also implies a very complex transmission scenario that must be understood if we are to prevent or mitigate filovirus outbreaks in the future. Efforts of a global network of scientists and healthcare workers have expanded our knowledge of filoviruses to meet the growing threat of Ebola and Marburg hemorrhagic fevers in Africa. In recent decades, several newly emerging diseases have resulted in major threats to both affected communities and global public health. Viruses from wildlife hosts in particular, have exhibited a capability for cross-species transmission (CST), and have caused high-impact diseases in humans Such as Ebola and Marburg hemorrhagic fevers, Nipah and severe acute respiratory syndrome (SAILS). It has been estimated that about 60.3% (Jones et al. 2008) of human infectious diseases are of animal origin (zoonoses) and even some important viral diseases that are traditionally considered of human origin, for example measles and smallpox, may very well have their prehistoric origins in wildlife (Wolfe et al 2007). It maybe logical and prudent therefore, to anticipate that there are other, new filoviruses out there that will cross into humans at some point in time. If we anticipate that these will happen and wish to be prepared for and mitigate this potential, then an understanding of filoviruses as a biologic system in the environment will be essential to that process. We will need to know how the ecological dynamic of CST interacts with a 'new' viruse's evolutionary factors to overcome environmental, demographic and host-specific barriers to transmission and infectivity to humans.

Pinzon, Jorge E.↗

Persistence Mapping Using EUV Solar Imager Data

We describe a simple image processing technique that is useful for the visualization and depiction of gradually evolving or intermittent structures in solar physics extreme-ultraviolet imagery. The technique is an application of image segmentation, which we call "Persistence Mapping," to isolate extreme values in a data set, and is particularly useful for the problem of capturing phenomena that are evolving in both space and time. While integration or "time-lapse" imaging uses the full sample (of size N ), Persistence Mapping rejects (N - 1)/N of the data set and identifies the most relevant 1/N values using the following rule: if a pixel reaches an extreme value, it retains that value until that value is exceeded. The simplest examples isolate minima and maxima, but any quantile or statistic can be used. This paper demonstrates how the technique has been used to extract the dynamics in long-term evolution of comet tails, erupting material, and EUV dimming regions.

Thompson, B. J.↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Multistep matrix integrators for real-time simulation

An explicit linear multistep matrix-integration technique is presented for vector systems of ODEs which employs the stability region placement approach to permit the time-step to be chosen independently of system eigenvalues. Closed-form solutions for the general p-step method and the case where the system matrix has zero eigenvalues are given. It is shown that system mode shapes are preserved over the integration process, and that the technique remains applicable to systems with eigenvalues at their origin without need for computing a matrix inversion.

De Abreu-Garcia, J. A.↗

Design of an L-band Microwave Radiometer with Active Mitigation of Interference

Radio frequency interference (RFI) impairs L-band radiometry outside the protected 20 MHz frequency band around 1413 MHz. However, bandwidths of 100 MHz or more are desired for certain remote sensing applications as well as certain astronomy applications. Because much of the RFI in this band is from radars with pulse lengths on the order of microseconds, traditional radiometers (i.e., those which directly measure total power or power spectral density integrated over time scales of milliseconds or greater) are poorly-suited to this task. Simply reducing integration time and discarding contaminated outputs may not be a practical answer due to the wide variety of modulations and pulse lengths observed in L-band RFI signals, the dynamic and complex nature of the associated propagation channels, and the logistical effort associated with post-measurement data editing. This motivates the design and development of radiometers capable of coherent sampling and adaptive, real-time mitigation of interference. Such a radiometer will be described in this presentation. This design is capable of coherently-sampling up to 100 MHz bandwidth at L-band. RFI mitigation is implemented in FPGA components so that real-time suppression is achieved. The system currently uses a cascade of basic time- and frequency-domain detection and blanking techniques; more advanced algorithms are under consideration. The modular FPGA-based architecture provides other benefits, such as the ability to implement extremely stable digital filters and the ability to reconfigure the system "on the fly". An overview of the basic design along with on-the-air results from an initial implementation will be provided in the presentation. Related L-band RFI surveys will be described to illustrate the relevance of this approach in a variety of operating conditions.

Hampson, G. A.↗

Design of an L-band Microwave Radiometer with Active Mitigation of Interference

Radio frequency interference (RFI) impairs L-band radiometry outside the protected 20 MHz frequency band around 1413 MHz. However, bandwidths of 100 MHz or more are desired for certain remote sensing applications as well as certain astronomy applications. Because much of the RFI in this band is from radars with pulse lengths on the order of microseconds, traditional radiometers (i.e., those which directly measure total power or power spectral density integrated over time scales of milliseconds or greater) are poorly-suited to this task. Simply reducing integration time and discarding contaminated outputs may not be a practical answer due to the wide variety of modulations and pulse lengths observed in L-band RFI signals, the dynamic and complex nature of the associated propagation channels, and the logistical effort associated with post-measurement data editing. This motivates the design and development of radiometers capable of coherent sampling and adaptive, real-time mitigation of interference. Such a radiometer will be described in this presentation. This design is capable of coherently-sampling up to 100 MHz bandwidth at L-band. RFI mitigation is implemented in FPGA components so that real-time suppression is achieved. The system currently uses a cascade of basic time- and frequency- domain detection and blanking techniques; more advanced algorithms are un- der consideration. The modular FPGA-based architecture provides other benefits, such as the ability to implement extremely stable digital filters and the ability to reconfigure the system "on the fly". An overview of the basic design along with on-the-air results from an initial implementation will be provided in the presentation. Related L-band RFI surveys will be described to illustrate the relevance of this approach in a variety of operating conditions.

Ellingson, S. W.↗

A numerical scheme to solve unstable boundary value problems

A new iterative scheme for solving boundary value problems is presented. It consists of the introduction of an artificial time dependence into a modified version of the system of equations. Then explicit forward integrations in time are followed by explicit integrations backwards in time. The method converges under much more general conditions than schemes based in forward time integrations (false transient schemes). In particular it can attain a steady state solution of an elliptical system of equations even if the solution is unstable, in which case other iterative schemes fail to converge. The simplicity of its use makes it attractive for solving large systems of nonlinear equations.

Kalnay Derivas, E.↗

Hybrid integrated optic modules for real-time signal processing

The most recent progress on four relatively new hybrid integrated optic device modules in LiNbO3 waveguides and one in YIG/GGG waveguide that are currently being studied are discussed. The five hybrid modules include a time-integrating acoustooptic correlator, a channel waveguide acoustooptic frequency shifter/modulator, an electrooptic channel waveguide total internal reflection moculator/switch, an electrooptic analog-to-digital converter using a Fabry-Perot modulator array, and a noncollinear magnetooptic modulator using magnetostatic surface waves. All of these devices possess the desirable characteristics of very large bandwidth (GHz or higher), very small substrate size along the optical path (typically 1.5 cm or less), single-mode optical propagation, and low drive power requirement. The devices utilize either acoustooptic, electrooptic or magnetooptic effects in planar or channel waveguides and, therefore, act as efficient interface devices between a light wave and temporal signals. Major areas of application lie in wideband multichannel optical real-time signal processing and communications. Some of the specific applications include spectral analysis and correlation of radio frequency (RF) signals, fiber-optic sensing, optical computing and multiport switching/routing, and analog-to-digital conversion of wide RF signals.

Tsai, C. S.↗