Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

On the Mechanical Behavior of LP-DED C103 Thin-Wall Structures

Laser Powder Directed Energy Deposition (LP-DED) can produce thin-wall features on the order of 1 mm. These features are essential for large structures operating in extreme environments such as regeneratively cooled nozzles and heat exchangers, which often make use of refractory metals. In this work, the mechanical behavior of LP-DED C103 was investigated via quasi-static tensile testing and low cycle fatigue (LCF) testing. The effects of vacuum stress relief (SR) and hot isostatic pressing (HIP) heat treatments were investigated for specimens in the vertical and horizontal build orientations during tensile testing. The AB and SR properties were lower than literature values for wrought and laser powder bed fusion (L-PBF) bulk components but higher than electron beam powder bed fusion (EB-PBF). The application of a HIP cycle improved strength by 7% and ductility by 27% past the initial as-built condition. Fracture images reveal that interlayer stress concentration sites are responsible for fracture in specimens in the vertical orientation. Meanwhile, fracture in the horizontal specimens mainly propagates at a slanted angle typical of plane stress conditions. The LCF results show cycles to failure ranging from 100 cycles to 8000 cycles for max strain levels of 2% and 0.5%, respectively. Fractography on the fatigue specimens reveals an increasing propagation zone as max strain levels are increased. The impact of these findings and future work are discussed in detail.

36 MATERIALS SCIENCE↗

Charge-flow structures as polymeric early-warning fire alarm devices

The charge-flow transistor (CFT) and its applications for fire detection and gas sensing were investigated. The utility of various thin film polymers as possible sensing materials was determined. One polymer, PAPA, showed promise as a relative humidity sensor; two others, PFI and PSB, were found to be particularly suitable for fire detection. The behavior of the charge-flow capacitor, which is basically a parallel-plate capacitor with a polymer-filled gap in the metallic tip electrode, was successfully modeled as an RC transmission line. Prototype charge-flow transistors were fabricated and tested. The effective threshold voltage of this metal oxide semiconductor was found to be dependent on whether surface or bulk conduction in the thin film was dominant. Fire tests with a PFI-coated CFT indicate good sensitivity to smouldering fires.

Sechen, C. M.↗

What Determines the Response: Test or Reference?

The stability of sensory memory has been studied by presenting a reference stimulus, a delay, and a test stimulus. As has been pointed out by Lages and Treisman (1998 Vision Research 38 557-572), the usual measure of performance depends only on the effect of test variations on the responses. The Weber fraction characterizing performance is more properly called the test stimulus Weber fraction. We measure the relative contribution of the test and reference to the response by the ratio of the test Weber fraction to the reference Weber fraction. The stimuli were two dark lines on a bright background. Seven reference separations, varying from 9.5 to 16.7 arc min, were intermixed in each run. Interstimulus intervals (ISI) of 50, 200 and 2000 msec and intertrial intervals (ITI) of 500 and 2500 msec were investigated. When the ISI was short (50 or 200 msec), for both ITIs, responses were determined equally by the test and reference. For the long ISI (2000 msec), the reference stimulus contributed less. However, only for the 500 msec ITI (and not for all observers) was the contribution of the reference stimulus negligible, as Treisman's criterion setting theory might suggest.

Chukova, S. V.↗

CO2 Suppression of PMMA Flames In Low-Gravity

Even though much has been learned about the effects of microgravity on material flammability, flame spread, and suppressant effectiveness, uncertainties remain regarding some of the practical aspects of fire protection in spacecraft. The experiments and simulations underway in this project are aimed directly at testing, understanding and improving NASA's existing policies and practices toward fire safety in spacecraft and extraterrestrial habitats. Specifically, the objectives of this research are: 1) Determine systematically the conditions that will ignite onboard flammable materials upon passage of an initial premixed gas, firebrand, or aerosol flame over these materials; 2) Test the effect of firebrands and configuration spacing; and 3) Determine the effectiveness of the flow of CO2 extinguisher or other extinguishing agents. Experimental and computational investigations are planned to achieve each of the three objectives above. Even though progress has been made in all of the areas, the majority of data has been collected for objective (3). Current results from these investigations are discussed.

Ruff, G. A.↗

Decontamination and Sterilization of Surfaces using Low Cost Ionic Liquids (CRADA Final Report)

The current study made a comprehensive literature review of the structure activity relationship (SAR) for microcidal and virucidal influence of ionic liquids. It summarized the key structure parameters that have close correlation to the antimicrobial and antiviral properties of the ILs. It proposed an experimental plan on developing and testing an effective ionic liquid from renewable lignocellulosic biomass. The goal is to understand the structure activity relationship (SAR) for virucidal influence of ionic liquids through comprehensive literature search and data analysis. A full experimental plan will be drafted based on the literature summary. Perform a comprehensive literature search to aid the development of an effective and easily deployable method to inactivate SARS-CoV-2 and decontaminate surfaces based on low-cost functional ionic liquids. These designer solvents have the potential to be a compelling and environmentally friendly alternative to common chemical disinfectants. Literature summary report including reported ionic liquid structures, synthesis and testing methods, and the structure activity relationship. Experimental plan on developing a low cost effective antiviral ionic liquid.

59 BASIC BIOLOGICAL SCIENCES↗

Combining Machine Learning and Comparative Effectiveness Methodology to Study Primary Care Pharmacotherapy Pathways for Veterans With Depression

Our objective is to demonstrate an innovative method combining machine learning with comparative effectiveness research techniques and to investigate a hitherto unstudied question about the effectiveness of common prescribing patterns. For Operation Enduring Freedom/Operation Iraqi Freedom veterans with major depressive disorder, we generate pharmacotherapy pathways (of antidepressants) using process mining and machine learning. We select the medication episodes that were started at subtherapeutic doses by the first assigned primary care physician and observe the paths that those medication episodes follow. Using 2-stage least squares, we test the effectiveness of starting at a low dose and staying low for longer versus ramping up fast while balancing observable and unobservable characteristics of patients and providers through instrumental variables. We leverage predetermined provider practice patterns as instruments. We collected outpatient pharmacy data for selective serotonin reuptake inhibitors and selective norepinephrine reuptake inhibitors, patient and provider characteristics (as control variables), and the instruments for our cohort. All data were extracted for the period between 2006 and 2020. There is a statistically significant positive effect (0.68, 95% CI 0.11–1.25) of “ramping up fast” on engagement in care. When we examine the effect of “ramping up slow”, we see an insignificant negative impact on engagement in care (−0.82, 95% CI −1.89 to 0.25). As expected, the probability of drop-out also seems to have a negative effect on engagement in care (−0.39, 95% CI −0.94 to 0.17). We further validate these results by testing with medication possession ratios calculated periodically as an alternative engagement in care metric. Our findings contradict the “Start low, go slow” adage, indicating that ramping up the dose of an antidepressant faster has a significantly positive effect on engagement in care for our population.

60 APPLIED LIFE SCIENCES↗

Hall Thruster Thermal Modeling and Test Data Correlation

HERMeS - Hall Effect Rocket with Magnetic Shielding. Developed through a joint effort by NASA/GRC and the Jet Propulsion Laboratory (JPL). Design goals: High power (12.5 kW) high Isp (3000 sec), high efficiency (> 60%), high throughput (10,000 kg), reduced plasma erosion and increased life (5 yrs) to support Asteroid Redirect Robotic Mission (ARRM). Further details see "Performance, Facility Pressure Effects and Stability Characterization Tests of NASAs HERMeS Thruster" by H. Kamhawi and team. Hall Thrusters (HT) inherently operate at elevated temperatures approx. 600 C (or more). Due to electric magnetic (E x B) fields used to ionize and accelerate propellant gas particles (i.e., plasma). Cooling is largely limited to radiation in vacuum environment.Thus the hardware components must withstand large start-up delta-T's. HT's are constructed of multiple materials; assorted metals, non-metals and ceramics for their required electrical and magnetic properties. To mitigate thermal stresses HT design must accommodate the differential thermal growth from a wide range of material Coef. of Thermal Expansion (CTEs). Prohibiting the use of some bolted/torqued interfaces.Commonly use spring loaded interfaces, particularly at the metal-to-ceramic interfaces to allow for slippage.However most component interfaces must also effectively conduct heat to the external surfaces for dissipation by radiation.Thus contact pressure and area are important.

Model↗

Assessing the Effectiveness of Generalized Likelihood Ratio Test Detector Schemes in Seismic Event Detection and the Avoidance of Nontarget Signals

Cross-correlation techniques have played a long-standing and pivotal role in seismic event monitoring. However, the performance of correlation-based detectors is challenged by nuisance seismicity, or nontarget signals. Such detections are a problem when the mission is to automatically map events to the correct source region. Using aftershocks of the 2014 $M_w$ 6.0 South Napa, California, earthquake, we demonstrate the effectiveness of utilizing a dynamic correlation processor framework in a generalized likelihood ratio test (GLRT) detector configuration to minimize nontarget detections. A GLRT maximizes a detection statistic with respect to one or more unknown parameters. In this case, the detection statistic is a template signal match against the waveform in a window sliding over a data stream, and the unknown parameter is an index variable indicating group membership of the template event or events. Detected events are assigned to the event group that yields the largest detection statistic. In this work, our results show that a GLRT detector will outperform a suite of independently operating correlation and subspace detectors in terms of having a lower nontarget detection rate at a given missed detection rate. We also show that a GLRT detector composed of a few high-rank subspace detectors has a slightly higher nontarget detection rate, but a significantly lower missed detection rate, than a GLRT detector composed of many low-rank subspace detectors. The high-rank GLRT configuration produced impressive results even with marginal data (single channel, single station, and very low time bandwidth product), which bodes well for the utility of building efficient aftershock classification systems and global monitoring systems at larger scales. However, future work is required to assess performance at the regional scale and to assess the performance of the system at detecting target events not used in the detector template creation.

58 GEOSCIENCES↗

Effects of Field of View and Visual Complexity on Virtual Reality Training Effectiveness for a Visual Scanning Task

Virtual reality training systems are commonly used in a variety of domains, and it is important to understand how the realism of a training simulation influences training effectiveness. The paper presents a framework for evaluating the effects of virtual reality fidelity based on an analysis of a simulation’s display, interaction, and scenario components. Following this framework, we conducted a controlled experiment to test the effects of fidelity on training effectiveness for a visual scanning task. The experiment varied the levels of field of view and visual realism during a training phase and then evaluated scanning performance with the simulator’s highest level of fidelity. To assess scanning performance, we measured target detection and adherence to a prescribed strategy. The results show that both field of view and visual realism significantly affected target detection during training; higher field of view led to better performance and higher visual realism worsened performance. Additionally, the level of visual realism during training significantly affected learning of the prescribed visual scanning strategy, providing evidence that high visual realism was important for learning the technique. The results also demonstrate that task performance during training was not always a sufficient measure of mastery of an instructed technique. That is, if learning a prescribed strategy or skill is the goal of a training exercise, performance in a simulation may not be an appropriate indicator of effectiveness outside of training—evaluation in a more realistic setting may be necessary.

97 MATHEMATICS AND COMPUTING↗

Cornering characteristics of the nose-gear tire of the space shuttle orbiter

An experimental investigation was conducted to evaluate cornering characteristics of the 32 x 8.8 nose gear tire of the space shuttle orbiter. Data were obtained on a dry concrete runway at nominal ground speeds ranging from 50 to 100 knots and over a range of tire vertical loads and yaw angles which span the expected envelope of loads and yaw angles to be encountered during space shuttle landing operations. The cornering characteristics investigated included side and drag forces and friction coefficients, aligning and overturning torques, friction force moment arm, and the lateral center of pressure shift. Results of this investigation indicate that the cornering characteristics of the space shuttle nose gear tire are insensitive to variations in ground speed over the range tested. The effects on cornering characteristics of variations in the tire vertical load and yaw angle are as expected. Trends observed are consistent with trends observed during previous cornering tests involving other tire sizes.

Vogler, W. A.↗

Dynamic assertion testing of flight control software

Assertions are used to dynamically test fault tolerant flight software. The experiment showed that 87% of typical errors introduced into the program would be detected by assertions. Detailed analysis of the test data showed that the number of assertions needed to detect those errors could be reduced to a minimal set. The analysis also revealed that the most effective assertions tested program parameters that provided greater indirect (collateral) testing of other parameters.

Andrews, D. M.↗

Dynamic assertion testing of flight control software

An experiment in using assertions to dynamically test fault tolerant flight software is described. The experiment showed that 87% of typical errors introduced into the program would be detected by assertions. Detailed analysis of the test data showed that the number of assertions needed to detect those errors could be reduced to a minimal set. The analysis also revealed that the most effective assertions tested program parameters that provided greater indirect (collateral) testing of other parameters.

Andrews, D. M.↗

Accelerated Irradiation Testing of Miniature Nuclear Fuel and Cladding Specimens

Qualification of advanced nuclear fuels and materials requires irradiation testing to provide input to predictive models for licensing. Oak Ridge National Laboratory has a long history of performing accelerated irradiation testing and post-irradiation examination (PIE) of miniature material specimens to determine the evolution of microstructure and thermophysical properties, leveraging the High Flux Isotope Reactor, dedicated hot cells, and instruments for handling small, low-level radioactive samples. This work gives a brief overview of irradiation testing of miniature samples to support qualification of advanced fuel cladding materials such as FeCrAl alloys and SiC ceramic matrix composites. More recent work has enabled separate effects irradiation testing of miniature fuel specimens. The small fuel size essentially decouples fuel temperature from fission rate, allowing for highly accelerated testing without large temperature gradients. This paper briefly highlights the new mini fuel irradiation facility and its first set of experiments.

Petrie, Christian↗

Introducing CGOLS: The Cholla Galactic Outflow Simulation Suite

Here, we present the Cholla Galactic OutfLow Simulations (CGOLS) suite, a set of extremely high resolution global simulations of isolated disk galaxies designed to clarify the nature of multiphase structure in galactic winds. Using the GPU-based code Cholla, we achieve unprecedented resolution in these simulations, modeling galaxies over a 20 kpc region at a constant resolution of 5 pc. The simulations include a feedback model designed to test the effects of different mass- and energy-loading factors on galactic outflows over kiloparsec scales. In addition to describing the simulation methodology in detail, we also present the results from an adiabatic simulation that tests the frequently adopted analytic galactic wind model of Chevalier & Clegg. Our results indicate that the Chevalier & Clegg model is a good fit to nuclear starburst winds in the nonradiative region of parameter space. Finally, we investigate the role of resolution and convergence in large-scale simulations of multiphase galactic winds. While our largest-scale simulations show convergence of observable features like soft X-ray emission, our tests demonstrate that simulations of this kind with resolutions greater than 10 pc are not yet converged, confirming the need for extreme resolution in order to study the structure of winds and their effects on the circumgalactic medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification of a selective inhibitor of human monocarboxylate transporter 4

Highlights: • hMCT4 transporter mediates the transport of metabolites such as l-lactate and pyruvate. • 5-ETZ, a bioisostere of propionate, is recognized by hMCT1 and hMCT4. • Fibrates, a group of isobutyrate derivatives, selectively inhibit hMCT4. • Bindarit might be the first-identified potent and selective inhibitor of hMCT4. The human monocarboxylate transporters (hMCTs/SLC16As) mediate the uptake of various monocarboxylates. Several isoforms of hMCTs are expressed in cancerous tissue as well as in normal tissue. In cancerous tissue, hypoxia induces the expression of hMCT4, which transports the energetic metabolite l-lactate across the plasma membrane. Since hMCT4 is involved in pH regulation and the transport of l-lactate in cancer cells, an hMCT4 inhibitor could function as an anticancer agent. Although several non specific hMCT inhibitors have been developed, a selective hMCT4 inhibitor has not yet been identified. The aim of this study was therefore to identify a selective hMCT4 inhibitor for use as a pharmacological tool for studying hMCT4. The heterologous expression system of the Xenopus oocyte was used to assess the effects of test compounds on hMCT4, whereupon isobutyrate derivatives, fibrates, and bindarit (2-[(1-benzyl-1H-indazol-3-yl)methoxy]-2-methylpropanoic acid) were demonstrated to exhibit selective inhibitory effects against this transporter. It is suggested that the structure formed from the joining of an isobutyrate moiety and two aromatic rings by appropriate linkers is important for acquiring the selective hMCT4-inhibiting activity. These findings provide novel insights into the ligand recognition of hMCT4, and contribute to the development of novel anticancer agents.

60 APPLIED LIFE SCIENCES↗

Experimental Evaluation of Several Key Factors Affecting Root Biomass Estimation by 1500 MHz Ground-Penetrating Radar

Accurate quantification of coarse roots without disturbance represents a gap in our understanding of belowground ecology. Ground penetrating radar (GPR) has shown significant promise for coarse root detection and measurement, however root orientation relative to scanning transect direction, the difficulty identifying dead root mass, and the effects of root shadowing are all key factors affecting biomass estimation that require additional research. Specifically, many aspects of GPR applicability for coarse root measurement have not been tested with a full range of antenna frequencies. We tested the effects of multiple scanning directions, root crossover, and root versus soil moisture content in a sand-hill mixed oak community using a 1500 MHz antenna, which provides higher resolution than the oft used 900 MHz antenna. Combining four scanning directions produced a significant relationship between GPR signal reflectance and coarse root biomass (R2 = 0.75) (p < 0.01) and reduced variability encountered when fewer scanning directions were used. Additionally, significantly fewer roots were correctly identified when their moisture content was allowed to equalize with the surrounding soil (p < 0.01), providing evidence to support assertions that GPR cannot reliably identify dead root mass. The 1500 MHz antenna was able to identify roots in close proximity of each other as well as roots shadowed beneath shallower roots, providing higher precision than a 900 MHz antenna. As expected, using a 1500 MHz antenna eliminates some of the deficiency in precision observed in studies that utilized lower frequency antennas.

1500 MHz antenna↗

Interaction of high voltage surfaces with the space plasma

High voltage solar arrays provide spacecraft power while optimizing mass and power efficiency. Operating such arrays in the space plasma environment can result in anomalously large currents being collected through insulation defects. Two thicknesses of the insulating material were tested, with no effect found due to insulator thickness. In these tests the polyimide thickness was always much less than the pinhole diameter. The pinhole area was varied over an area range of more than 30:1. It was found that the current collected was independent of the pinhole area for hole diameters from 0.35 to 2.0 mm. Two types of adhesives were tried in two different configurations. The adhesives were chosen for their extreme difference in vacuum qualifications. Neither adhesive types nor configuration made a significant difference in current collection. The temperature of the insulating material was also varied. It was found that current collection decreased with increasing temperature. Tests were conducted to see if pinhole current collection decreased with time, as was indicated by the effects of several short tests. Current was collected for over four hours while the conductor potential was held constant at 1000 volts. A smooth decrease with time was not observed, but rather a roughly constant current collection with brief surges to high values. Tests were also conducted with the simulated solar cell biased negative. The current was found to be proportional to pinhole area.

Kaufman, H. R.↗

REMOVAL OF IODIDE FROM GROUNDWATER USING SILVER CHLORIDE WHITE PAPER

Releases from the F and H Area Seepage Basins on the Savannah River Site (SRS) have caused groundwater plumes that contain a variety of contaminants. These plumes are releasing contaminants into Fourmile Branch, which is a small tributary of the Savannah River. The metallic contaminant releases to the branch are being controlled by base injection. The base injection targets cationic contaminants and was not intended to reduce the concentration of I-129 in groundwater. SRS and the regulatory agencies believe it is appropriate to investigate remedial alternatives that could reduce the I-129. The Savannah River Site Area Closures Projects (ACP) and the Savannah River National Laboratory (SRNL) are developing an innovative in situ treatment for I-129 using silver chloride (AgCl). The proposed AgCl amendment has a very small particle size and is designed to be injected into the contaminated aquifer to capture I-129. The solubility of AgI is several orders of magnitude lower than the solubility of AgCl. Thus, when I-129 comes in contact with AgCl it forms silver iodide (AgI), which is very stable and essentially insoluble in water. SRNL has been performing bench-scale column tests on the effectiveness of silver chloride to capture iodine in an aqueous solution. These initial tests evaluate silver chloride in four different particle sizes; 4-5 millimeters (standard reagent silver chloride), approximately 1 millimeters (sieved reagent silver chloride), approximately 2 micrometers (ultra fine grind without a grinding agent), and <1 micrometer (ultra fine grind with a grinding agent). The first two experiments with macro-sized particles were proof of principle tests. In these the AgCl was mechanically mixed into a portion of the soil filling the columns. The last two were to test the effectiveness of injecting particles suspended in an aqueous solution--the ability to inject the particles, their retention in the column and their effectiveness at removing dissolved iodide from solution. The amendments for these two columns were obtained from a private company specializing in ultra-fine grinding of materials. They were ground in propylene glycol because when ground in water silver metal electroplated onto the steel grinding equipment. Table 1 shows the list of columns and the amendment characteristics. The results of these column experiments demonstrate that solid silver chloride is highly effective at removing dissolved iodine from water and should be an effective amendment for removing I-129 from groundwater. Based on known groundwater chemistry and the reaction of AgCl with I- to produce AgI, the only interference will be natural dissolved stable iodine (I-127). Millings et al. (2002) reported a maximum I-127 concentration of 2.2 ug/L in groundwater from well P-27D, a background water table well near F-Area. The concentration of dissolved iodide used in these experiments is approximately 4500 times this natural concentration. Therefore, a AgCl amendment in the subsurface at the same concentration used in these experiments, might effectively remove I-129 for up to 4500 times the number of pore volumes of groundwater as observed here. This assumes homogeneous distribution of the amendment and no occlusion by other minerals in the subsurface. The only reliable way to evaluate these effects is by trial in the field. The column studies also suggest that the amendment is readily injectable into sediments, but will not be highly mobile. The fact that the effluent from Column 4 shows no iodide breakthrough after nearly 11 pore volumes indicates that some of the injected AgCl was trapped in the column. A mass balance on iodide reacted so far suggests that a minimum of 0.056 grams of silver chloride was trapped in the column to react with the iodide. This is 5.6% of the mass injected. Assume the 1-foot column represents the first foot of sediment in the subsurface into which the amendment is injected. If 5.6% of the AgCl particles are trapped in each subsequent foot of sediment through which the injectate moves, at 100 feet the concentration of particles will be 3% of the injection concentration. This is the maximum possible concentration indicated by these column studies, because far more AgCl may have been trapped in the column. Continued data collection will tell how much more. Dissolved silver concentrations from the silver chloride amendment will be low. Effluent from Column 1 was analyzed for dissolved silver and the concentrations were below the detection limit of 0.2 mg/L.

36 MATERIALS SCIENCE↗