Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shape optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Review of SiC material development for nuclear fusion applications: Cross-cutting research and emerging opportunities

The SiC-based materials, particularly SiC-fiber-reinforced SiC matrix (SiC/SiC) composites, show strong potential for structural and functional applications in future fusion power plants because they can operate at high temperatures with a range of coolants and breeders, thereby enabling higher energy conversion efficiency. Here, this paper presents recent advancements in the development of SiC-based materials, focusing on processing techniques and material performance and resistance under fusion-relevant environments. The processing activities have emphasized near-net-shape fabrication and the joining of SiC subcomponents, with processing methods and material compositions informed by previous irradiation experiments on various grades of SiC. Research on irradiation effects has remained focused on degradation mechanisms and the microstructural optimization of SiC/SiC composites irradiated to high neutron damage levels. Analysis of irradiation defects in SiC has advanced via the application of cutting-edge characterization methods, among which Raman spectroscopy is becoming a common tool to assess atomic-scale chemical disorder. Fusion–fission crosscutting irradiation research has explored combined effects in SiC/SiC composites with application-relevant geometries, including bowing of SiC/SiC composite channels under neutron flux gradients, stress evolution in SiC/SiC composite tubes under through-thickness temperature gradients, and irradiation-enhanced corrosion in SiC. Finally, research opportunities for component testing and assessment under fusion-relevant conditions, in support of emerging concepts from the private fusion sector, are discussed.

Advanced manufacturing↗

Origami silicon optoelectronics for hemispherical electronic eye systems

Digital image sensors in hemispherical geometries offer unique imaging advantages over their planar counterparts, such as wide field of view and low aberrations. Deforming miniature semiconductor-based sensors with high-spatial resolution into such format is challenging. Here we introduce a simple origami approach for fabricating single-crystalline silicon-based focal plane arrays and artificial compound eyes that have hemisphere-like structures. Convex isogonal polyhedral concepts allow certain combinations of polygons to fold into spherical formats. Using each polygon block as a sensor pixel, the silicon-based devices are shaped into maps of truncated icosahedron and fabricated on flexible sheets and further folded either into a concave or convex hemisphere. These two electronic eye prototypes represent simple and low-cost methods as well as flexible optimization parameters in terms of pixel density and design. Results demonstrated in this work combined with miniature size and simplicity of the design establish practical technology for integration with conventional electronic devices.

42 ENGINEERING↗

Biopolymer-supramolecular polymer hybrids for photocatalytic hydrogen production

Solar generation of H 2 is a promising strategy for dense energy storage. Supramolecular polymers composed of chromophore amphiphile monomers containing perylene monoimide (PMI) have been reported as crystalline light-harvesting assemblies for aqueous H 2 -evolving catalysts. Gelation of these supramolecular polymers with multivalent ions creates hydrogels with high diffusivity but insufficient mechanical stability and catalyst retention for reusability. We report here on using sodium alginate (SA) biopolymer to both induce supramolecular polymerization of PMI and co-immobilize them with catalysts in a robust hydrogel with high diffusivity that can also be 3D-printed. Faster mass transfer was achieved by controlling the material macrostructure by reducing gel diameter and microstructure by reducing biopolymer loading. Optimized gels produce H 2 at rates rivaling solution-based PMI and generate H 2 for up to 6 days. The PMI assemblies in the SA matrix create a percolation network capable of bulk-electron transfer under illumination. These PMI–SA materials were then 3D-printed on conductive substrates to create 3D hydrogel photoelectrodes with optimized porosity. The design of these versatile hybrid materials was bioinspired by the soft matter environment of natural photosynthetic systems and opens the opportunity to carry out light-to-fuel conversion within soft matter with arbitrary shapes and particular local environments.

36 MATERIALS SCIENCE↗

Effects of Al-5Ti-1B master alloy on the microstructural evaluation of a highly alloyed aluminum alloy produced by SIMA process

This study was undertaken to investigate the influence of Al-5Ti-1B master alloy on the structural characteristics of Al-12Zn-3 Mg-2.5Cu aluminum alloy. The optimum amount of Ti containing master alloy for proper grain refining was selected as 6 wt.%. A modified strain-induced, melt-activated (SIMA) process for semi-solid processing of alloys was proposed. In order to examine the effectiveness of the modified SIMA process, the recrystallized microstructures of the Al alloy (Al-12Zn-3 Mg-2.5Cu) prepared by the modified SIMA processes were macroscopically. The modified SIMA process employed casting, warm multi-forging, recrystallization and partial melting instead of the conventional process. Reheating condition to obtain a fine globular microstructure was optimized. The microstructure evolution of reheated Al-12Zn-3 Mg-2.5Cu aluminum alloy was characterized by SEM (Scanning electron microscopy) and optical microscopy. In this study the relation between the induced strain with size and shape of grain size has been studied. Results indicated that with the increase of strain sphericity of particles, their size decreases and sphericity takes place in less reahiting time.

36 MATERIALS SCIENCE↗

Nanopatterning and tuning of optical taper antenna apex for tip-enhanced Raman scattering performance

This paper focuses on finding optimal electrochemical conditions from linear sweep voltammetry analysis for preparing highly reproducible tip-enhanced Raman scattering (TERS) conical gold tips with dc-pulsed voltage etching. Special attention is given to the reproducibility of tip apex shapes with different etchant mixtures. We show that the fractional Brownian motion model enables a mathematical description of the decaying current kinetics during the whole etching process up to the cutoff event. Further progress in preparation of highly reproducible smooth and sharp tip apexes is related to the effect of an additive, such as isopropanol, to aqueous acids. A finite-difference time-domain method based near-field analysis provides evidence that TERS performance depends critically on tip orientation relative to a highly focused laser beam. A TERS based criterion for recognizing gold tips able to couple/decouple optical near- and far-fields is proposed.

36 MATERIALS SCIENCE↗

First-principle study of quantum confinement effect on small sized silicon quantum dots using density-functional theory

Density functional theory (DFT), as a first-principle approach has successfully been implemented to study nanoscale material. Here, DFT by numerical basis-set was used to study the quantum confinement effect as well as electronic properties of silicon quantum dots (Si-QDs) in ground state condition. Selection of quantum dot models were studied intensively before choosing the right structure for simulation. Next, the computational result were used to examine and deduce the electronic properties and its density of state (DOS) for 14 spherical Si-QDs ranging in size up to ∼ 2 nm in diameter. The energy gap was also deduced from the HOMO-LUMO results. The atomistic model of each silicon QDs was constructed by repeating its crystal unit cell of face-centered cubic (FCC) structure, and reconstructed until the spherical shape obtained. The core structure shows tetrahedral (T{sub d}) symmetry structure. It was found that the model need to be passivated, and hence it was noticed that the confinement effect was more pronounced. The model was optimized using Quasi-Newton method for each size of Si-QDs to get relaxed structure before it was simulated. In this model the exchange-correlation potential (V{sub xc}) of the electrons was treated by Local Density Approximation (LDA) functional and Perdew-Zunger (PZ) functional.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Retrieval of high time resolution growth factor probability density function from a humidity-controlled fast integrated mobility spectrometer

Hygroscopicity describes the tendency of aerosol particle to uptake water and is among the key parameters in determining the impact of atmospheric aerosols on global radiation and climate. A hygroscopicity tandem differential mobility analyzer (HTDMA) system is the most widely utilized instrument for determining the aerosol hygroscopic growth. Because of the time needed to scan the classifying voltage of the DMA, HTDMA measurement normally requires a minimum of 30 min to characterize the particle hygroscopic growth at a single relative humidity for five to six different sizes. This slow speed is often inadequate for measurements onboard mobile platforms or when aerosols evolve rapidly. Recently, a humidity-controlled fast integrated mobility spectrometer (HFIMS) was developed for measuring the hygroscopic growth of particles. The measurement speed of the HFIMS is about one order of magnitude faster than that of the conventional HTDMA. Here, a data inversion routine is developed to retrieve the growth factor probability density function (GF-PDF) of particles measured by the HFIMS. The inversion routine considers the transfer functions of the upstream DMA and the downstream water-based fast integrated mobility spectrometer (FIMS), and derives the GF-PDF that reproduces the measured responses of the HFIMS. The performance of the inversion routine is examined using ambient measurements with different assumptions for the spectral shape of the particle GF-PDF (multimodal lognormal or piecewise linear). The influences of the data inversion parameters and counting statistics on the inverted GF-PDFs were further investigated, and an approach to determine the optimized inversion parameters is presented.

47 OTHER INSTRUMENTATION↗

Strong-field QED limitations on TeV-class plasma wakefield accelerators

We demonstrate that quantum and classical radiation effects can become non-negligible for TeV-class beams propagating through plasma channels typical of staged plasma accelerators. Although the quantum nonlinearity parameter χ e remains small under currently envisioned experimental conditions, the cumulative influence of radiation over long acceleration distances can lead to significant modifications to the beam’s energy spread, emittance, and polarization. Our analytic models, validated by particle-in-cell simulations, highlight that for standard Gaussian beams, the orbit-induced energy spread dominates over quantum stochastic effects but can be mitigated by tailoring the beam profile, for example, through ring-shaped transverse distributions. In regimes where the radiation reaction approaches the accelerating force, the emittance may be cooled, forming distinctive ring-shaped phase-space structures. Finally, we analyze the influence of the radiation effect on spin transport inside the wakefield. These findings underscore the importance of considering both classical and quantum radiation dynamics in the design and optimization of future high-intensity plasma accelerators.

accelerator↗

Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Single-shot high-resolution characterization of optical pulses by spectral phase diversity

The concept of spectral phase diversity is proposed and applied to the temporal characterization of optical pulses. The experimental trace is composed of the measured power of a plurality of ancillary optical pulses derived from the pulse under test by adding known amounts of chromatic dispersion. The spectral phase of the pulse under test is retrieved by minimizing the error between the experimental trace and a trace calculated from the optical spectrum using the known diagnostic parameters. An assembly composed of splitters and dispersive delay fibers has been used to generate 64 ancillary pulses whose instantaneous power can be detected in a single shot with a high-bandwidth photodiode and oscilloscope. Pulse-shape reconstruction for pulses shorter than the photodetection impulse response has been demonstrated.The diagnostic is experimentally shown to accurately characterize pulses from a chirped-pulse–amplification system when its stretcher is detuned from the position for optimal recompression. As a result, various investigations of the performance with respect to the number of ancillary pulses and the range of chromatic dispersion generated in the diagnostic are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Unified Data-Driven Approach for Programming In Situ Analysis and Visualization: An Interim Report of Sandia Sub-Team Contributions

As we look ahead to next generation high performance computing platforms, the placement and movement of data is becoming the key-limiting factor on both performance and energy efficiency. Furthermore, the increased quantities of data the systems are capable of generating, in conjunction with the insufficient rate of improvements in the supporting I/0 infrastructure, is forcing applications away from the off-line post-processing of data towards techniques based on in ,situ analysis and visualization. Together, these challenges are shaping how we will both design and develop effective, performant and energy-efficient software. In particular, the challenges highlight the need for data and data-centric operations to be fundamental in the reasoning about, and optimization of, scientific workflows on extreme-scale architectures.

97 MATHEMATICS AND COMPUTING↗

Predicting the Longitudinally and Radially Varying Gut Microbiota Composition Using Multi-Scale Microbial Metabolic Modeling

Background: The gut microbiota is a heterogeneous group of microbes that is spatially distributed along various sections of the intestines and across the mucosa and lumen in each section. Understanding the dynamics between the spatially differential microbial populations and the driving forces for the observed spatial organization will provide valuable insights into important questions such as the nature of colonization of the infant gut and different types of inflammatory bowel disease localized in different regions of the intestines. However, in most studies, the microbiota is sampled only at a single site (often feces) or from a particular anatomical site of the intestines. Differential oxygen availability is putatively a key factor shaping the spatial organization. Results: To test this hypothesis, we constructed a community genome-scale metabolic model consisting of representative organisms for the major phyla present in the human gut microbiome. By solving step-wise optimization problems embedded in a dynamic framework to predict community metabolism and integrate the mucosally-adherent with the luminal microbiome between consecutive sections along the intestines, we were able to capture (i) the essential features of the spatially differential composition of obligate anaerobes vs. facultative anaerobes and aerobes determined experimentally, and (ii) the accumulation of microbial biomass in the lumen. Sensitivity analysis suggests that the spatial organization depends primarily on the oxygen-per-microbe availability in each region. Oxygen availability is reduced relative to the ~100-fold increase in mucosal microbial density along the intestines, causing the switch between aerobes and anaerobes. Conclusion: The proposed integrated dynamic framework is able to predict spatially differential gut microbiota composition using microbial genome-scale metabolic models and test hypotheses regarding the dynamics of the gut microbiota. It can potentially become a valuable tool for exploring therapeutic strategies for site-specific perturbation of the gut microbiota and the associated metabolic activities.

59 BASIC BIOLOGICAL SCIENCES↗

Techniques for optimizing nanotips derived from frozen taylor cones

Optimization techniques are disclosed for producing sharp and stable tips/nanotips relying on liquid Taylor cones created from electrically conductive materials with high melting points. A wire substrate of such a material with a preform end in the shape of a regular or concave cone, is first melted with a focused laser beam. Under the influence of a high positive potential, a Taylor cone in a liquid/molten state is formed at that end. The cone is then quenched upon cessation of the laser power, thus freezing the Taylor cone. The tip of the frozen Taylor cone is reheated by the laser to allow its precise localized melting and shaping. Tips thus obtained yield desirable end-forms suitable as electron field emission sources for a variety of applications. In-situ regeneration of the tip is readily accomplished. These tips can also be employed as regenerable bright ion sources using field ionization/desorption of introduced chemical species.

36 MATERIALS SCIENCE↗

Integrated operation scenarios: Chapter 6 of the special issue: on the path to tokamak burning plasma operation

Here we report the progress of the development and optimization of operational scenarios for ITER and beyond, focusing upon baseline, hybrid, and steady-state scenarios since 2007. This includes advancements made by the integrated operation scenarios (IOS) topical group of the international tokamak physical activity as well as contributions from the broader tokamak community. The key area of research involves developing IOSs that encompass tokamak physics, operation, and technology by utilizing integrated modeling and control strategies. This requires leveraging available actuators to simultaneously control plasma position and shape, MHD activities that could lead to disruptions, transport, plasma-wall interaction and power exhaust, fuel cycle, fusion burn, and tritium breeding. The control extends from the plasma initiation phase, through the current ramp-up, flattop, start and end of the fusion burn, and current ramp-down, to the plasma termination phase. A review of the currently developed scenarios and modeling is provided in terms of (i) optimizing plasma initiation in ITER, (ii) preparing for the low activation phase to fully commission all tokamak systems and establish and validate physics and scenario conditions in preparation for deuterim-tritium (DT) operation, (iii) developing and preparing baseline and hybrid scenarios to demonstrate the feasibility of achieving these regimes within device constraints, (iv) exploring steady-state scenarios to meet ITER’s steady-state goals, (v) evaluating and preparing actuators for ITER, (vi) developing integrated control solutions using shared actuators. The most notable achievements include; (i) the development of ITER demonstration discharges by matching various dimensionless parameters, (ii) the development of scenarios in an ITER-like tungsten environment and DT operation, and (iii) the development of scenarios in superconducting tokamaks, enabling long-pulse operations with similar coil constraints to ITER. Along with these significant achievements, outstanding issues and recommendations for further research and development are provided. Importantly, this study goes beyond simply updating the ITER Physics Basis; it carries profound implications for the broader field of burning plasma research, offering valuable insights and guidance for the next generation of fusion experiments and devices.

ITER↗

SU-G-IeP3-14: Updating Tools for Radiographic Technique Charts

Purpose: Manual technique selection in radiography is needed for imaging situations where there is difficulty in proper positioning for AEC, prosthesis, for non-bucky imaging, or for guiding image repeats. Basic information about how to provide consistent image signal and contrast for various kV and tissue thickness is needed to create manual technique charts, and relevant for physicists involved in technique chart optimization. Guidance on technique combinations and rules-of-thumb to provide consistent image signal still in use today are based on measurements with optical density of screen-film combinations and older generation x-ray systems. Tools such as a kV-scale chart can be useful to know how to modify mAs when kV is changed in order to maintain consistent image receptor signal level. We evaluate these tools for modern equipment for use in optimizing proper size scaled techniques. Methods: We used a water phantom to measure calibrated signal change for CR and DR (with grid) for various beam energies. Tube current values were calculated that would yield a consistent image signal response. Data was fit to provide sufficient granularity of detail to compose technique-scale chart. Tissue thickness approximated equivalence to 80% of water depth. Results: We created updated technique-scale charts, providing mAs and kV combinations to achieve consistent signal for CR and DR for various tissue equivalent thicknesses. We show how this information can be used to create properly scaled size-based manual technique charts. Conclusion: Relative scaling of mAs and kV for constant signal (i.e. the shape of the curve) appears substantially similar between film-screen and CR/DR. This supports the notion that image receptor related differences are minor factors for relative (not absolute) changes in mAs with varying kV. However, as demonstrated creation of these difficult to find detailed technique-scales are useful tools for manual chart optimization.

60 APPLIED LIFE SCIENCES↗

Fast IMRT with narrow high energy scanned photon beams

Purpose: Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, experiments have been performed with full range targets, generating a broad bremsstrahlung beam, in combination with multileaf collimators or material compensators. In the present publication, the first measurements with fast narrow high energy (50 MV) scanned photon beams are presented indicating an interesting performance increase even though some of the hardware used were suboptimal. Methods: Inverse therapy planning was used to calculate optimal scanning patterns to generate dose distributions with interesting properties for fast IMRT. To fully utilize the dose distributional advantages with scanned beams, it is necessary to use narrow high energy beams from a thin bremsstrahlung target and a powerful purging magnet capable of deflecting the transmitted electron beam away from the generated photons onto a dedicated electron collector. During the present measurements the scanning system, purging magnet, and electron collimator in the treatment head of the MM50 racetrack accelerator was used with 3-6 mm thick bremsstrahlung targets of beryllium. The dose distributions were measured with diodes in water and with EDR2 film in PMMA. Monte Carlo simulations with geant4 were used to study the influence of the electrons transmitted through the target on the photon pencil beam kernel. Results: The full width at half-maximum (FWHM) of the scanned photon beam was 34 mm measured at isocenter, below 9.5 cm of water, 1 m from the 3 mm Be bremsstrahlung target. To generate a homogeneous dose distribution in a 10 x 10 cm{sup 2} field, the authors used a spot matrix of 100 equal intensity beam spots resulting in a uniformity of collimated 80%-20% penumbra of 9 mm at a primary electron energy of 50 MeV. For the more complex cardioid shaped dose distribution, they used 270 spots, which at a pulse repetition frequency of 200 Hz is completed every 1.36 s. Conclusions: The present measurements indicate that the use of narrow scanned photon beams is a flexible and fast method to deliver advanced intensity modulated beams. Fast scanned photon IMRT should, therefore, be a very interesting modality in the delivery of biologically optimized radiation therapy with the possibility for in vivo treatment verification with PET-CT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Letter Report Documenting Progress of Second Generation ATF FeCrAl Alloy Fabrication

Development of the 2 nd generation ATF FeCrAl alloy has been initiated, and a candidate alloy was selected for trial tube fabrication through hot-extrusion and gun-drilling processes. Four alloys based on Fe-13Cr-4.5Al-0.15Y in weight percent were newly cast with minor alloying additions of Mo, Si, Nb, and C to promote solid-solution and second-phase precipitate strengthening. The alloy compositions were selected with guidance from computational thermodynamic tools. The lab-scale heats of ~ 600g were arc-melted and drop-cast, homogenized, hot-forged and -rolled, and then annealed producing plate shape samples. An alloy with Mo and Nb additions (C35MN) processed at 800°C exhibits very fine sub-grain structure with the sub-grain size of 1-3μm which exhibited more than 25% better yield and tensile strengths together with decent ductility compared to the other FeCrAl alloys at room temperature. It was found that the Nb addition was key to improving thermal stability of the fine sub-grain structure. Optimally, grains of less than 30 microns are desired, with grains up to and order of magnitude in desired produced through Nb addition. Scale-up effort of the C35MN alloy was made in collaboration with a commercial cast company who has a capability of vacuum induction melting. A 39lb columnar ingot with ~81mm diameter and ~305mm height (with hot-top) was commercially cast, homogenized, hot-extruded, and annealed providing 10mm-diameter bar-shape samples with the fine sub-grain structure. This commercial heat proved consistent with materials produced at ORNL at the lab-scale. Tubes and end caps were machined from the bar sample and provided to another work package for the ATF-1 irradiation campaign in the milestone M3FT-14OR0202251.

2nd generation ATF FeCrAl alloy↗

Uncovering translation roadblocks during the development of a synthetic tRNA

Ribosomes are remarkable in their malleability to accept diverse aminoacyl-tRNA substrates from both the same organism and other organisms or domains of life. This is a critical feature of the ribosome that allows the use of orthogonal translation systems for genetic code expansion. Optimization of these orthogonal translation systems generally involves focusing on the compatibility of the tRNA, aminoacyl-tRNA synthetase, and a non-canonical amino acid with each other. As we expand the diversity of tRNAs used to include non-canonical structures, the question arises as to the tRNA suitability on the ribosome. Specifically, we investigated the ribosomal translation of allo-tRNA UTu1 , a uniquely shaped (9/3) tRNA exploited for site-specific selenocysteine insertion, using single-molecule fluorescence. With this technique we identified ribosomal disassembly occurring from translocation of allo-tRNA UTu1 from the A to the P site. Using cryo-EM to capture the tRNA on the ribosome, we pinpointed a distinct tertiary interaction preventing fluid translocation. Through a single nucleotide mutation, we disrupted this tertiary interaction and relieved the translation roadblock. With the continued diversification of genetic code expansion, our work highlights a targeted approach to optimize translation by distinct tRNAs as they move through the ribosome.

59 BASIC BIOLOGICAL SCIENCES↗