Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

A mosaic infrared sensor for space astronomy, phase 3

Short wavelength (1 to 3 micron) HgCdTe mosaic detector arrays for space astronomy purposes were fabricated and studied. Honeywell will test and analyze these arrays at moderate temperatures (300-130K). Low temperature testing will be performed at the University of Hawaii. Short wavelength mosaic arrays were fabricated on three wafers and one array from each wafer was tested and analyzed. The p-type base carrier concentration on these wafers was an order of magnitude lower than typically used so far on this program (10 to the 14/cc as compared to 10 to the 15/cc). Tunneling currents are expected to decrease with this decrease in carrier concentration, resulting in improved performance at very low temperatures. The risk with such a low carrier concentration is that fixed charge in the surface passivating layer must be carefully controlled to prevent surface inversion layers.

Sood, A. K.↗

A novel occupancy detection solution using low-power IR-FPA based wireless occupancy sensor

Significant energy savings can be achieved by operating heating, ventilation, and air conditioning control systems with indoor occupancy measurement information. This paper presents a novel plug-and-play occupancy sensing method which will enable temporal minimization of building energy consumption to meet building usage behavior without privacy concerns. The proposed wireless occupancy sensing platform is based on long-wave infra-red (LWIR) focal-plane arrays (FPAs), or thermal imagers, that detect thermal energy rather than visible light. We developed an advanced sensor package consisting of multiple thermal imagers with low-cost optical enhancements to increase field of view and increase sensitivity to occupant detection (filtering building clutter). These imagers can be coupled with radio frequency and ultrasonic-based radar to enhance data collection at key occupant zone boundaries to improve accuracy. Standard filtering and estimation techniques from the image processing and computer vision communities are introduced to overcome the accuracy issues suffered by traditional PIR based sensing, especially when occupants remain relatively still. Accurate low-level counting of individuals can be achieved with minimal impact on privacy. As a result, the proposed occupancy detection method can work as a retrofit to enable real-time understanding of the building operational state and usage behavior. Sensor data obtained from real test building zones was used to test the efficacy of the method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of the Mid-Frequency Arrays for Advanced ACTPol

The Advanced ACTPol upgrade on the Atacama Cosmology Telescope aims to improve the measurement of the cosmic microwave background anisotropies and polarization, using four new dichroic detector arrays fabricated on 150-mm silicon wafers. These bolometric cameras use AlMn transition-edge sensors, coupled to feedhorns with orthomode transducers for polarization sensitivity. The first deployed camera is sensitive to both 150 and 230 GHz. Here, we present the laboratory characterization of the thermal parameters and optical efficiencies for the two newest fielded arrays, each sensitive to both 90 and 150 GHz. We provide assessments of the parameter uniformity across each array with evaluation of systematic uncertainties. Lastly, we show the arrays’ initial performance in the field.

42 ENGINEERING↗

On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

Kizhner, Semion↗

QWIPs, SLS, Landsat and the International Space Station

In 1988 DARPA provided funding to NASA’s Goddard Space Flight Center to support the development of GaAs Quantum Well Infrared Photodetectors (QWIP). The goal was to make a single element photodetector that might be expandable to a two-dimensional array format. Ultimately, this led to the development of a 128 x 128 element array in collaboration with AT&T Bell Labs and Rockwell Science Center in 1990. We continued to develop numerous generations of QWIP arrays most recently resulting in the multi-QWIP focal plane for the NASA-US Geological Survey (USGS) Landsat 8 mission launched in 2013 and a similar instrument on the Landsat 9 mission to be launched in 2020. Toward the end of the Landsat 8 QWIP-based Thermal Infrared Sensor (TIRS) instrument the potential of the newly developed Strained Layer Superlattice (SLS) detector array technology became of great interest to NASA for three primary reasons: 1) higher operating temperature; 2) broad spectral response and; 3) higher sensitivity. We have collaborated extensively with QmagiQ, LLC and Northwestern University to further pursue and advance the SLS technology ever since we started back in 2012. In December of 2018 we launched the first SLS-based IR camera system to the International Space Station on board the Robotic Refueling Mission #3 (RRM3). This paper will describe the evolution of QWIP technology leading to the current development of SLS-based imaging systems at the Goddard Space Flight Center over the past 30 years.

Jhabvala, M.↗

Atomically engineered epitaxial anatase TiO 2 metal-semiconductor field-effect transistors

Here, anatase TiO 2 is a promising material for a vast array of electronic, energy, and environmental applications, including photocatalysis, photovoltaics, and sensors. A key requirement for these applications is the ability to modulate its electrical properties without dominant dopant scattering and while maintaining high carrier mobility. Here, we demonstrate the room temperature field-effect modulation of the conducting epitaxial interface between anatase TiO 2 and LaAlO 3 (001), which arises for LaO-terminated LaAlO 3 , while the AlO 2- terminated interface is insulating. This approach, together with the metal-semiconductor field-effect transistor geometry, naturally bypasses the gate/channel interface traps, resulting in a high field-effect mobility μ FE of 3.14 cm 2 (V s) –1 approaching 98% of the corresponding Hall mobility μ Hall . Accordingly, the channel conductivity is modulated over 6 orders of magnitude over a gate voltage range of ~4 V.

36 MATERIALS SCIENCE↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A dedicated mirror-magnet experiment to study quench characteristics and dependencies in $Nb_{3}Sn$ coils and explore improvements of diagnostics capabilities

A single Nb3Sn short quadrupole coil in a mirror-magnet configuration was employed to investigate a wide range of phenomena and to serve as test-bed for diagnostics developments. A configurable array of spot-heaters was installed on the inner coil surface for control of induced quench conditions. Several different quench antenna arrays were positioned along the coil inner surface, and included significant sensor overlap for assessment of their relative efficiency and operation. Multiple acoustic sensors were placed on the pole and at coil ends. Optical fibers in grid configurations were put in different places on the coil and magnet for strain assessment, along with standard resistive strain gauges. Current spikes in the magnet circuit were monitored. This plethora of instrumentation aimed to support investigations on induced and spontaneous quenches, among other goals, and was supplemented by standard voltage-tap-based measurements. Voltage tap data of induced quenches from various spot-heater configurations was investigated for similarities to voltage development in spontaneous quenches. Quench antennas provided insights about current redistribution in the quenching coil and coil splices. The Quench Current-boosting Device was applied and the effect on coil training examined. This paper describes motivations behind the research, the overall test setup and main results.

Stoynev, Stoyan [Fermilab]↗

Temporal development of composition, spectra, and anisotropies during upstream particle events

An analysis is conducted of the temporal development of particle intensity, composition, and anisotropies during diffuse particle events. The observations were made with an ultra-low energy charge analyzer (ULECA) sensor. ULECA basically consists of an electrostatic deflection system and an array of solid state detectors. The simultaneous measurement of energy per charge and total energy makes it possible to determine the charge state of a particle. Spectra are derived by an iterative technique involving the numerical integration of particle spectra with the energy response functions of the individual detectors. The presented data are explained in terms of temporal and spatial structures in the upstream region. The temporal structures during the event onset are consistent with a time-dependent first-order Fermi acceleration model, as discussed by Scholer et al. (1980).

Ipavich, F. M.↗

The test facility requirements for the thermal vacuum thermal balance test of the Cosmic Background Explorer Observatory

The Cosmic Background Explorer Observatory (COBE) underwent a thermal vacuum thermal balance test in the Space Environment Simulator (SES). This was the largest and most complex test ever conducted at this facility. The 4 x 4 m (13 x 13 ft) spacecraft weighed approx. 2223 kg (4900 lbs) for the test. The test set up included simulator panels for the inboard solar array panels, simulator panels for the flight cowlings, Sun and Earth Sensor stimuli, Thermal Radio Frequency Shield heater stimuli and a cryopanel for thermal control in the Attitude Control System Shunt Dissipator area. The fixturing also included a unique 4.3 m (14 ft) diameter Gaseous Helium Cryopanel which provided a 20 K environment for the calibration of one of the spacecraft's instruments, the Differential Microwave Radiometer. This cryogenic panel caused extra contamination concerns and a special method was developed and written into the test procedure to prevent the high buildup of condensibles on the panel which could have led to backstreaming of the thermal vacuum chamber. The test was completed with a high quality simulated space environment provided to the spacecraft. The test requirements, test set up, and special fixturing are described.

Milam, Laura J.↗

Test facility requirements for the thermal vacuum thermal balance test of the Cosmic Background Explorer Observatory

The Cosmic Background Explorer Observatory (COBE) underwant a thermal vacuum thermal balance test in the Space Environment Simulator (SES). This was the largest and most complex test ever conducted at this facility. The 4 x 4 m (13 x 13 ft) spacecraft weighed approx. 2223 kg (4900 lbs) for the test. The test set up included simulator panels for the inboard solar array panels, simulator panels for the flight cowlings, Sun and Earth Sensor stimuli, Thermal Radio Frequency Shield heater stimuli and a cryopanel for thermal control in the Attitude Control System Shunt Dissipator area. The fixturing also included a unique 4.3 m (14 ft) diameter Gaseous Helium Cryopanel which provided a 20 K environment for the calibration of one of the spacecraft's instruments, the Differential Microwave Radiometer. This cryogenic panel caused extra contamination concerns and a special method was developed and written into the test procedure to prevent the high buildup of condensibles on the panel which could have led to backstreaming of the thermal vacuum chamber. The test was completed with a high quality simulated space environment provided to the spacecraft. The test requirements, test set up, and special fixturing are described.

Milam, Laura J.↗

Aided targeting system simulation evaluation

Simulation research was conducted at the Crew Station Research and Development Facility on the effectiveness and ease of use of three targeting systems. A manual system required the aviator to scan a target array area with a simulated second generation forward looking infrared (FLIR) sensor, locate and categorize targets, and construct a target hand-off list. The interface between the aviator and the system was like that of an advanced scout helicopter (manual mode). Two aided systems detected and categorized targets automatically. One system used only the FLIR sensor and the second used FLIR fused with Longbow radar. The interface for both was like that of an advanced scout helicopter aided mode. Exposure time while performing the task was reduced substantially with the aided systems, with no loss of target hand-off list accuracy. The fused sensor system showed lower time to construct the target hand-off list and a slightly lower false alarm rate than the other systems. A number of issues regarding system sensitivity and criterion, and operator interface design are discussed.

Demaio, Joe↗

An Array of Frequency Selective Bolometers (FSB) for the Spectral Energy Distribution (SPEED) Camera

The SPEED camera is being developed to study the spectral energy distributions of high redshift galaxies using the Heinrich Hertz Telescope (HHT) in Arizona. SPEED requires a small cryogenic detector array of 2x2 pixels with each pixel having four frequency bands in the 150-350 GHz range. Here we describe the development of the detector array of these high efficiency FSBs. The FSB design provides the multi-pixel multi-spectral band capability required for SPEED in a compact stackable array. The SPEED bolometers will use proximity effect superconducting transition edge sensors as their temperature-sensing element allowing for higher levels of multiplexing in future applications.

Silverberg, R. F.↗

Passive Wake Acoustics Measurements at Denver International Airport

From August to September 2003, NASA conducted an extensive measurement campaign to characterize the acoustic signal of wake vortices. A large, both spatially as well as in number of elements, phased microphone array was deployed at Denver International Airport for this effort. This paper will briefly describe the program background, the microphone array, as well as the supporting ground-truth and meteorological sensor suite. Sample results to date are then presented and discussed. It is seen that, in the frequency range processed so far, wake noise is generated predominantly from a very confined area around the cores.

Wang, Frank Y.↗

The USNA MIDN Microdosimeter Instrument

This paper describes the MIcroDosimetry iNstrument (MIDN) mission now under development at the United States Naval Academy. The instrument is manifested to fly on the MidSTAR-1 spacecraft, which is the second spacecraft to be developed and launched by the Academy s faculty and midshipmen. Launch is scheduled for 1 September 2006 on an ATLAS-5 launch vehicle. MIDN is a rugged, portable, low power, low mass, solid-state microdosimeter designed to measure in real time the energy distributions of energy deposited by radiation in microscopic volumes. The MIDN microdosimeter sensor is a reverse-biased silicon p-n junction array in a Silicon-On-Insulator (SOI) configuration. Microdosimetric frequency distributions as a function of lineal energies determine the radiation quality factors in support of radiation risk estimation to humans.

Pisacane, V. L.↗

Theoretical Noise Analysis on a Position-sensitive Metallic Magnetic Calorimeter

We report on the theoretical noise analysis for a position-sensitive Metallic Magnetic Calorimeter (MMC), consisting of MMC read-out at both ends of a large X-ray absorber. Such devices are under consideration as alternatives to other cryogenic technologies for future X-ray astronomy missions. We use a finite-element model (FEM) to numerically calculate the signal and noise response at the detector outputs and investigate the correlations between the noise measured at each MMC coupled by the absorber. We then calculate, using the optimal filter concept, the theoretical energy and position resolution across the detector and discuss the trade-offs involved in optimizing the detector design for energy resolution, position resolution and count rate. The results show, theoretically, the position-sensitive MMC concept offers impressive spectral and spatial resolving capabilities compared to pixel arrays and similar position-sensitive cryogenic technologies using Transition Edge Sensor (TES) read-out.

Smith, Stephen J.↗

Cytometer on a chip

An assay technique for label-free, highly parallel, qualitative and quantitative detection of specific cell populations in a sample and for assessing cell functional status, cell-cell interactions and cellular responses to drugs, environmental toxins, bacteria, viruses and other factors that may affect cell function. The technique includes a) creating a first array of binding regions in a predetermined spatial pattern on a sensor surface capable of specifically binding the cells to be assayed; b) creating a second set of binding regions in specific spatial patterns relative to the first set designed to efficiently capture potential secreted or released products from cells captured on the first set of binding regions; c) contacting the sensor surface with the sample, and d) simultaneously monitoring the optical properties of all the binding regions of the sensor surface to determine the presence and concentration of specific cell populations in the sample and their functional status by detecting released or secreted bioproducts.

Lynes, Michael A.↗

GaAs QWIP Array Containing More Than a Million Pixels

A 1,024 x 1,024-pixel array of quantum-well infrared photodetectors (QWIPs) has been built on a 1.8 x 1.8- cm GaAs chip. In tests, the array was found to perform well in detecting images at wavelengths from 8 to 9 m in operation at temperatures between 60 and 70 K. The largest-format QWIP prior array that performed successfully in tests contained 512 x 640 pixels. There is continuing development effort directed toward satisfying actual and anticipated demands to increase numbers of pixels and pixel sizes in order to increase the imaging resolution of infrared photodetector arrays. A 1,024 x 1,024-pixel and even larger formats have been achieved in the InSb and HgCdTe material systems, but photodetector arrays in these material systems are very expensive and manufactured by fewer than half a dozen large companies. In contrast, GaAs-photodetector-array technology is very mature, and photodetectors in the GaAs material system can be readily manufactured by a wide range of industrial technologists, by universities, and government laboratories. There is much similarity between processing in the GaAs industry and processing in the pervasive silicon industry. With respect to yield and cost, the performance of GaAs technology substantially exceeds that of InSb and HgCdTe technologies. In addition, GaAs detectors can be designed to respond to any portion of the wavelength range from 3 to about 16 micrometers - a feature that is very desirable for infrared imaging. GaAs QWIP arrays, like the present one, have potential for use as imaging sensors in infrared measuring instruments, infrared medical imaging systems, and infrared cameras.

Jhabvala, Murzy↗