Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Multi-Sensor Optimal Motion Planning for Radiological Contamination Surveys by Using Prediction-Difference Maps

Distributed and networked mobile sensor platforms using unmanned aerial and/or ground vehicles to survey areas of interest offer a safer and more efficient method for radiological contamination mapping; however, most applications rely on uniformly sweeping of the area in a raster-type motion without utilizing the information available in a dynamic sense. We have developed a fully autonomous optimal motion planning procedure for networks with two or more mobile sensors. The procedure utilizes well-established concepts of Gaussian processes in combination with control laws based on centroidal Voronoi tessellations to achieve optimal next-iteration sensor movements. A new method of informing optimal motion planning is proposed, whereby the absolute difference between the prior and current full-map prediction, referred to as the prediction-difference map, is used as the spatial density function within each Voronoi cell, providing immediate and iterative feedback for dynamic use of available information. The Gaussian process regression model used to estimate the contamination in unvisited locations also provides prediction uncertainties, and can be used as a quantitative metric to assess the confidence in the calculated contamination map; these estimates and prediction uncertainties are unavailable for standard uniform survey routines as they can only produce maps in the vicinity of observed locations. We present through simulation the achievable performance gains from using this new method by directly comparing to a uniform survey method. Results show that using the prediction-difference maps to inform motion planning procedures offers a faster rate of producing an accurate and convergent map relative to a uniform survey route.

47 OTHER INSTRUMENTATION↗

Leak Detection and Sensor Importance Within a Solvent Extraction Process Abstract

In anticipation of the Special Nuclear Material test bed (Beartooth), Idaho National Laboratory has developed a smaller, multi-sensor system for analyzing the solvent extraction process. These systems will allow for research into nuclear fuel processing operations. The multi-sensor system consists of a row of centrifugal contactors and allows for measurement sources that are not traditionally used in the solvent extraction process to be explored including temperature, vibration, acoustics, pH, color, flow, and motor current. Currently, the solvent extraction process is very labor intensive and requires vigilant operators to identify the occurrence of leaks, which can be common during startup or after any change to the system. This study aims to locate leaks using non-traditional measurement sources then to identify which signals were of greatest importance in making this classification using Local Interpretable Model-agnostic Explanations. These results can be used to help solvent extraction process operators detect leaks and to inform future test beds designers to which sensors contain relevant, actionable information in this scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing a Spectroelectrochemical Sensor's Performance for Detecting [Ru(bpy)3]2+ in Natural and Treated Water

A spectroelectrochemical sensor that combines three modes of selectivity in a single device was evaluated in natural and treated water samples using tris-(2,2’-bipyridyl) ruthenium(II) dichloride hexahydrate, [Ru(bpy)3]2+, as a model analyte. The sensor was an optically transparent indium tin oxide (ITO) electrode coated with a thin film of partially sulfonated polystyrene-block-poly(ethylene-ran-butylene)-block-polystyrene (SSEBS). As the potential of the ITO electrode was cycled from +0.7 to +1.3 V, the analyte changed from the colored [Ru(bpy)3]2+ complex to colorless [Ru(bpy)3]3+ complex and the change in absorbance at 450 nm was used as the optical signal for quantification. Calibration curves were obtained for [Ru(bpy)3]2+ in natural well water, river water and treated tap water with detection limits of 108, 139 and 264 nM, respectively. A standard addition method was developed to determine an *unknown* spike addition concentration of [Ru(bpy)3]2+ in well water. The spectroelectrochemical sensor determined the concentration of [Ru(bpy)3]2+ spiked into a sample of Hanford well water to be 0.39*0.03 mM versus the actual concentration of 0.40 mM.

ITO electrode↗

Machine Learning Discrimination and Ultrasensitive Detection of Fentanyl Using Gold Nanoparticle-Decorated Carbon Nanotube-Based Field-Effect Transistor Sensors

The opioid overdose crisis is a global health challenge. Fentanyl, an exceedingly potent synthetic opioid, has emerged as a leading contributor to the surge in opioid-related overdose deaths. The surge in overdose fatalities, particularly due to illicitly manufactured fentanyl and its contamination of street drugs, emphasizes the urgency for drug-testing technologies that can quickly and accurately identify fentanyl from other drugs and quantify trace amounts of fentanyl. In this paper, gold nanoparticle (AuNP)-decorated single-walled carbon nanotube (SWCNT)-based field-effect transistors (FETs) are utilized for machine learning-assisted identification of fentanyl from codeine, hydrocodone, and morphine. The unique sensing performance of fentanyl led to use machine learning approaches for accurate identification of fentanyl. Employing linear discriminant analysis (LDA) with a leave-one-out cross-validation approach, a validation accuracy of 91.2% is achieved. Meanwhile, density functional theory (DFT) calculations reveal the factors that contributed to the enhanced sensitivity of the Au-SWCNT FET sensor toward fentanyl as well as the underlying sensing mechanism. Finally, fentanyl antibodies are introduced to the Au-SWCNT FET sensor as specific receptors, expanding the linear range of the sensor in the lower concentration range, and enabling ultrasensitive detection of fentanyl with a limit of detection at 10.8 fg mL –1 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aneurysm Sac Pressure Measurement with Minimally Invasive Implantable Pressure Sensors: An Alternative to Current Surveillance Regimes after EVAR?

Current protocols for surveillance after endovascular repair (EVAR) of abdominal aortic aneurysms are mostly based on costly and time-consuming imaging procedures and aim to detect adverse events such as graft migration, endoleaks or aneurysm sac enlargement. These imaging procedures are either associated with radiation exposure to the patients or may be harmful to the patient due to the use of iodine- or gadolinium-containing contrast agents. Furthermore the advantages of EVAR in the short term might be negated by the necessity for endograft surveillance over years. Thus, alternative modalities for follow-up are being investigated. One of these technologies provides pressure information directly from the aneurysm sac. This noninvasive, telemetric pressure sensing was tested in vitro as well as in first clinical trials and was able to identify successful aneurysm exclusion after EVAR. The telemetric pressure sensors showed a promising efficacy and accuracy in detecting type I and type III endoleaks and will help to clarify the clinical relevance of type II endoleaks. This article provides an overview of the in vitro sensors investigated as well as the first clinical trials and the sensors' potential to change the current endograft surveillance regimes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In-situ sensor monitoring of multi-class gas porosity formation in laser powder bed fusion using convolutional neural network

In-situ monitoring of defect formation remains a significant challenge in the laser powder bed fusion (LPBF) process. Recent advances have enabled real-time defect detection with machine learning and in-situ sensing technologies; however, most studies focus on binary classification of keyhole pores, limiting nuanced multi-class pore differentiation and formation mechanisms. This work introduces a multi-class pore detection framework (no pore, small pores < 15 µm, and large pores > 15 µm) by leveraging photodiode sensor data alongside high-fidelity synchrotron X-ray imaging. The 15 µm threshold is selected to distinguish between two fundamentally different defect mechanisms, following the physical size-mechanism boundary established by prior high-resolution synchrotron X-ray characterization of Al6061 LPBF. Distinguishing these classes is critical because large keyhole pores are structurally detrimental, whereas small gas pores are often benign, requiring different process control strategies. Thermal emission monitoring data collected simultaneously with high-speed X-ray imaging at the Stanford Synchrotron Radiation Lightsource (SSRL), are correlated with subsurface melt pool dynamics to establish ground truth. Continuous Wavelet Transform (CWT) with optimized parameters converts the photodiode time-series signals into time–frequency images, facilitating feature extraction. Convolutional Neural Networks (CNN) are then applied for real-time multi-class pore classification in an average inference time of 1 ms per signal window. It achieves 79% accuracy and an Area Under the Receiver Operating Characteristic curve (AUC ROC) score of 0.89 with five-fold cross-validation. The results demonstrate that coupling CWT-based feature engineering with CNN architecture enables reliable multi-class pore detection in Al6061 builds using affordable in-situ sensors. This approach advances scalable and affordable quality assurance in additive manufacturing by moving beyond binary defect detection toward more nuanced classification of porosity mechanisms with in-situ sensors and machine learning.

Laser powder bed fusion, Multi-class pores, In-sit↗

Enhanced sensitivity of hemoglobin sensor using dual-core photonic crystal fiber

A Hemoglobin (Hb) biosensor based on dual-core photonic crystal fiber is proposed and analyzed. In this paper, the effective refractive index dependency on the Hb concentration within a blood sample is utilized in obtaining the transmission spectrum variation. The results are calculated using full vectorial finite element method. Through this study, the effect of the structure geometrical parameters on the sensor performance is optimized to maximize the sensor sensitivity. The numerical results show a sensitivity of 8.013 nm/g/dL for the X-polarized mode at 3.7 cm fiber length and 7.68 nm/g/dL for the Y-polarized mode at 3.2 cm fiber length of the proposed sensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity enhancement of surface plasmon resonance sensor with 2D material covered noble and magnetic material (Ni)

In this paper, surface plasmon resonance (SPR) sensor on 2D materials such as MoS{sub 2} and graphene on Au and magnetic material Ni in Kretschmann configuration is analyzed using transfer matrix method. Here we noted that by sandwiching the MoS{sub 2} layer between the Au and Ni film and adding graphene over Ni film improved the sensitivity as high as 229°/RIU. We also noted that the sensitivity of the proposed sensor changes with the addition of no. of layers of graphene and MoS{sub 2}. We expect that such a high sensitivity SPR sensor could find optional application in chemical examination, medical diagnostic and biological detections.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A method for the characterization of intra-pixel response of infrared sensor

Due to the response variations within a pixel, response of sensor varies with the positions of the point target. The accurate measurement of intra-pixel response of the sensor is the key to high-precision centroid estimation and radiometric calibration. In this paper, we establish an intra-pixel response model based on the pixel structure and use Gauss function to describe the beam spot profile. We further calculate the full width at half maximum (FWHM) of the Gauss function and the fill factor of the infrared sensor using the grid search algorithm. Experimental results show that the Gauss function FWHM differences among different pixels using the same radius could be less than 6%. The fill factors are not constant in different pixels because of errors in the process of manufacture and assembly, and the error between model and measured values is less than 3.6%. This work could be useful for stellar calibration and centroid estimation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of in situ high temperature sensor based on the direct absorption spectroscopy signal of ammonia gas for coal-fired power plant

The selective catalytic reduction and non-selective catalytic reduction (SCR/SNCR) are the most popular de-NOx processes for coal-fired power plant, where the real-time temperature is a significant parameter. A new developed tunable diode laser spectroscopy used for measuring the temperature of ammonia (NH{sub 3}) in the process of SCR/SNCR influenced by strong exhaust gas matrices CO{sub 2} and H{sub 2}O was presented in this paper. Two lines near 6605 cm{sup −1} were selected, with rather weak temperature dependency and minimal interface from CO{sub 2} and H{sub 2}O according to HITRAN12 database. A homemade heating equipment for high temperature laser spectroscopy measurement was developed based on an ARM microcontroller. The temperature calibration experiments of absorption lines were carried out at variable concentrations under different temperatures. The spectral signals of 2.5%, 3.5% and 4.5% NH{sub 3} were observed for validation of the generalization and robustness of the sensor. The calibration and validation experimental results show that the maximum measurement error and global average error of the temperature sensor with the temperature ranging from 453 to 653 K are less than 2% and 1.38%, respectively. It demonstrates that our proposed sensor with high accuracy and linearity, and can be utilized to measure the temperature in SNCR/SCR process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel refractive index sensor based on fiber bragg grating in nano-bore optical fiber

In this paper, we propose a novel refractive index sensor with large dynamic range based on fiber Bragg grating in the nano-bore optical fiber. The spectral responses of grating on the filling index in the bore with different bore diameters and index ranges are numerically studied by the finite element method and coupled mode theory based transmission matrix method. It is found that the Bragg wavelength of grating is sensitive to the filling index in the bore. The influences of bore diameter on the wavelength sensitivity, resolution and dynamic range of the index sensor are analyzed. There exists a trade off between the linear dynamic range and sensitivity of index when the bore diameter varies. The optimized wavelength sensitivity and resolution of filling index are 53.6923 nm/index unit and 9.3123 × 10{sup −6} index under a linear index range of 1.0–1.4 using 2 µm bore diameter. The optimized linear dynamic range of index is 1.0–1.48 with wavelength sensitivity of 13.3056 nm/index unit and resolution of 3.7578 × 10{sup −5} index using 1 µm bore diameter. Our proposed index sensor has the technical advantages of simple all-fiber structure, large index range, and potential capability to synchronously detect index, temperature and strain.

36 MATERIALS SCIENCE↗

Indium tin oxide and silver based fiber optic SPR sensor: an experimental study

Fabrication and characterization of SPR based fiber optic sensor utilizing bi-layers of ITO-Ag is presented. Effects of thicknesses of ITO and Ag layers on the sensitivity of sensor are studied experimentally. Sensitivity ascends as the thickness of Ag layer is enhanced till 30 nm and it starts decreasing as the thickness of Ag layers is further increased beyond 30 nm. SPR sensor based on 40 nm thick ITO layer-30 nm thick Ag layer demonstrates highest sensitivity.

36 MATERIALS SCIENCE↗

Brain sensor and communication model using plasmonic microring antenna network

In this paper, the feasibility of using multi-plasmonic sensing probes embedded nanoring resonators within a microring resonator system for brain signal probing and the investigation proposed. The plasmonic sensor probes made of gold grating placed within the center nanorings, from which the sensor network of the coupling light from the multi-plasmonic probes to the main ring established. The coupling between light (photon) power and nano-gold grating generate the plasmonic polariton dipoles and propagate within the system. The whispering gallery mode generates at the center rings, which will couple into the sensor probes and the induced change in optical signals that can detect via the system ports. The coupling between the generated polaritons and external stimuli from the sub-brain cells will change the optical output signals, where the electro-optic signal conversion can be applied. In manipulation, the changes in the grating periods of the sensing probes will affect the changes in the output signals, which can distinguish by the sensing probe signal Bragg wavelengths. The optical filter applied at each of the device port to attenuate the output signal that can be applied for brain investigation. The simulation results have shown that the low output power can detect for sub-level investigation.

42 ENGINEERING↗

Electrochemical DNA sensors on the basis of electropolymerized thionine and Azure B with addition of pillar[5]arene as an electron transfer mediator

A DNA sensor was developed on the basis of glassy carbon electrode coated with polymeric forms of thionine and Azure B. Introduction of carbon black and pillar[5]arene into the electrode composition increases the efficiency of polymerization and the oxidation peak currents of dyes due to the mediating effect of the macrocycle. The addition of DNA onto the sensor surface and into the reaction mixture differently influences the electrochemical activity of poly(Azure B) and polythionine. The control of changes in current-voltage characteristics allowed us to identify the heat denaturation of DNA and its oxidation by reactive oxygen species generated upon the reaction of hydrogen peroxide and copper(II) salt. The DNA sensors can find application in the diagnosis of DNA damage on exposure to carcinogens and in screening of cytotoxic anticancer drugs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Properties of Resistive Hydrogen Sensors as a Function of Additives of 3D-Metals Introduced in the Volume of Thin Nanocrystalline SnO{sub 2} Films

Analysis of the results of studying electrical and gas sensitive characteristics of the molecular hydrogen sensors based on thin nanocrystalline SnO{sub 2} films coated with dispersed Au layers and containing Au+Ni and Au+Co impurities in the bulk showed that the characteristics of these sensors are more stable under the prolonged exposure to hydrogen in comparison with Au/SnO{sub 2}:Sb, Au films modified only with gold. It has been found that introduction of the nickel and cobalt additives increases the band bending at the grain boundaries of tin dioxide already in freshly prepared samples, which indicates an increase in the density N{sub i} of the chemisorbed oxygen. It is important that during testing, the band bending eφ{sub s} at the grain boundaries of tin dioxide additionally slightly increases. It can be assumed that during crystallization of films under thermal annealing, the 3d-metal atoms in the SnO{sub 2} volume partially segregate on the surface of microcrystals and form bonds with lattice oxygen, the superstoichiometric tin atoms are formed, and the density N{sub i} increases. If the bonds of oxygen with nickel and cobalt are stronger than those with tin, then, under the prolonged tests, atomic hydrogen will be oxidized not by lattice oxygen, but mainly by the chemisorbed one. In this case, stability of the sensors’ characteristics increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-Criteria Sensor Placement for Emergency Response

This paper describes an approach to locating a set of sensors to provide early warning of a dangerous chemical or biological agent release. The objective of the warning system is to minimize potential fatalities and any other health-related problems resulting from either an accidental release (such as a chemical spill) or from of a deliberate act of terrorism. The sensor placement solution is described as part of a broader simulation approach that considers the number of sensors available for deployment, the effect of weather conditions on the spread and concentration of the agent released, the speed at which appropriate emergency response actions can be taken to evacuate or shelter-in-place, and factors that make some release points more likely than others, such as the relative ease of site access or the presence of high priority or high impact targets within the at-risk area. Aerial photography and GIS also play important roles in the decision support environment described.

54 ENVIRONMENTAL SCIENCES↗

Multimodal sensor fusion for real-time standoff estimation in directed energy deposition

In Laser Powder-based Direct Energy Deposition (LP-DED) systems, achieving consistency, precision and quality of produced parts requires tight control over printing parameters. One of the critical parameters is the standoff distance. Maintaining an optimal standoff height is crucial for achieving correct laser power density and powder catchment efficiency, as both laser and powder streams are focused at this distance. Here, this study introduces a novel approach using multimodal sensor fusion to predict standoff height in real-time. The proposed system integrates two low-profile, cost-effective sensors: an RGB coaxial camera and a high frequency and high dynamic range microphone. By utilizing a simple fully connected neural network, trained on a limited dataset, data fusion of these sensors allowed for the real-time prediction of the standoff height. The results demonstrate high resolution and accuracy of the predictions across multiple geometries and a wide range of standoff heights. This approach offers a simple, and cost-effective solution for real-time standoff height monitoring and lays the groundwork for future integration into commercial LP-DED systems.

42 ENGINEERING↗

Intracellular delivery of poly(I:C) induces apoptosis of fibroblast-like synoviocytes via an unknown dsRNA sensor

Fibroblast-like synoviocytes (FLS) express functional membranous and cytoplasmic sensors for double-stranded (ds)RNA. Notably, FLS undergo apoptosis upon transfection with the synthetic dsRNA analog poly(I:C). We here studied the mechanism of intracellular poly(I:C) recognition and subsequent cell death in FLS. FLS responded similarly to poly(I:C) or 3pRNA transfection; however, only intracellular delivery of poly(I:C) induced significant cell death, accompanied by upregulation of pro-apoptotic proteins Puma and Noxa, caspase 3 cleavage, and nuclear segregation. Knockdown of the DExD/H-box helicase MDA5 did not affect the response to intracellular poly(I:C); in contrast, knockdown of RIG-I abrogated the response to 3pRNA. Knockdown of the downstream adaptor proteins IPS, STING, and TRIF or inhibition of TBK1 did not affect the response to intracellular poly(I:C), while knockdown of IFNAR blocked intracellular poly(I:C)-mediated signaling and cell death. We conclude that a so far unknown intracellular sensor recognizes linear dsRNA and induces apoptosis in FLS. - Highlights: • Intracellular poly(I:C) and 3pRNA evoke immune responses in FLS. • Only intracellular delivery of poly(I:C) induces FLS apoptosis. • FLS do not require MDA5 for their response to intracellular poly(I:C). • FLS respond to intracellular poly(I:C) independent of IPS and STING. • An unknown intracellular sensor recognizes linear dsRNA in FLS.

60 APPLIED LIFE SCIENCES↗