Pu'u Poli'ahu, Mauna Kea: A Possible Analog for the Hematite Bearing Layer Located in Gale Crater, Mars.

Hyperspectral data detected by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) on board Mars Reconnaissance Orbiter (MRO) indicated the presence of a hematite bearing ridge on Mount Sharp situated in the Gale Crater, Mars. [Fraeman]. The presence of this mineral in high concentrations is indicative of possible aqueous origins. [Fraeman] In 2012, Curiosity Rover landed in Gale Crater on Mars. Curiosity's mission is to determine Mars' habitability and is equipped with an advanced suite of scientific instruments that are capable of conducting analyses on rocks and soil. The hematite bearing ridge on Mount Sharp is thought to be a good candidate of study for Curiosity. To better understand this type of terrain, the study of analog sites similar in geologic setting is of great importance. One site thought to be a comparable analog is a cinder cone called Pu'u Poli'ahu located on the summit of Mauna Kea, Hawaiʻi. Poli'ahu is unique among the tephra cones of Mauna Kea because it is thought to have formed in subaqueous conditions approximately 170,000 to 175,000 years ago. [Porter] Consequently located on the inner flanks of Poli'ahu is a rock outcrop that contains hematite. Samples were collected from the outcrop and characterized using the following instruments: Digital Microscope, Panalytical X‐ray diffraction (XRD), and scanning electron microscope (SEM). The initial preparation of the rocks involved documenting each sample by creating powdered samples, thick sections, and photo documentation.

Adams, M. E.↗

Microstructure characterization of electric field assisted sintering (EFAS) sintered metallic and ceramic materials using local thermal diffusivity measurement

Electric Field Assisted Sintering (EFAS, also referred to as spark plasma sintering) is a powerful technology for the consolidation of powder materials. The high heating rate during the sintering process is critical for minimizing energy consumption, but it can also cause microstructure heterogeneities in sintered parts, such as spatially varied porosity. The examination of localized porosity usually requires the use of a scanning electron microscope with a carefully prepared surface. In this paper, photothermal radiometry is used to measure local thermal diffusivity and extract localized porosity of EFAS-sintered parts by using a percolation-threshold model. Applying this approach, we identified the radial position-dependent porosity variation in EFAS parts, which is likely formed due to the large temperature gradient during the sintering process. This approach has a unique advantage because it can measure samples with minimal or no surface preparation, enabling the possibility of in situ characterization in EFAS with proper system modification. Necessary modifications on the measurement approach for EFAS deployment and in situ characterization are also discussed.

36 MATERIALS SCIENCE↗

Building 438 Drainage Channel Soil Sampling and Analysis Plan (February 2023)

This Soil Sampling and Analysis Plan (SAP) was prepared by the Environmental Function Area (EFA)/Technical Services Department (TSD) of the Environment, Safety & Health (ES&H) Directorate for the Project Management Office (PMO) for the proposed Building 438 Drainage Channel Project (project) located near Building 438 (B438) in the southern portion, Building 433 (B433) in the middle portion, and Building 543 (B543) in the northern portion (project area as shown on Figure 1). The purpose of the SAP was to describe the procedures for collection and analysis of environmental samples and evaluation of analytical data (chemical and radiological) to determine management options of excavated soil during project construction in accordance with Lawrence Livermore National Laboratory’s (LLNL) Soils Screening and Management Plan (SSMP) (LLNL 2022), which is consistent with U.S. Environmental Protection Agency (EPA) guidance for developing Data Quality Objectives for environmental data (EPA 2006). The SAP was developed in accordance with the SSMP and based on preliminary design information provided to EFA by PMO.

54 ENVIRONMENTAL SCIENCES↗

Preparation and Thermoelectric Properties of Semiconcucting Zn(sub 4) Sb(sub 3)

Hot-pressed samples fothe semiconducting compound Beta - Zn(sub 4) Sb(sub 3) were prepared and characterized by x-ray and microprobe analysis. Some physical properties of Beta - Zn(sub 4) Sb(sub 3) were determined and its thermoelectric properties measured between room temperature and 650K.

Beta Zn4Sb3 semiconductors semiconductor compounds↗

Chemical vapor deposition for silicon cladding on advanced ceramics

Polycrystalline Si was used to clad several advanced ceramic materials such as SiC, Si3N4, sapphire Al2O3, pyrolytic BN, and Si by a CVD process. The thickness of Si cladding ranged from 0.025 to 3.0 mm. CVD Si adhered quite well to all the above materials except Al3O, where the Si cladding was highly stressed and cracked or delaminated. A detailed material characterization of Si-clad SiC samples showed that Si adherence to SiC does not depend much on the substrate surface preparation; that the thermal cycling and polishing of the samples do not cause delamination; and that, in four-point bend tests, the Si-SiC bond remains intact, with the failure occurring in the Si.

Goela, Jitendra S.↗

Lens Model Accuracy in the Expected LSST Lensed AGN Sample

Strong gravitational lensing of active galactic nuclei (AGN) enables measurements of cosmological parameters through time-delay cosmography (TDC). With data from the upcoming LSST survey, we anticipate using a sample of O(1000) lensed AGN for TDC. To prepare for this dataset and enable this measurement, we construct and analyze a realistic mock sample of 1300 systems drawn from the OM10 (Oguri & Marshall 2010) catalog of simulated lenses with AGN sources at $z<3.1$ in order to test a key aspect of the analysis pipeline, that of the lens modeling. We realize the lenses as power law elliptical mass distributions and simulate 5-year LSST i-band coadd images. From every image, we infer the lens mass model parameters using neural posterior estimation (NPE). Focusing on the key model parameters, $θ_E$ (the Einstein Radius) and $γ_{lens}$ (the projected mass density profile slope), with consistent mass-light ellipticity correlations in test and training data, we recover $θ_E$ with less than 1% bias per lens, 6.5% precision per lens and $γ_{lens}$ with less than 3% bias per lens, 8% precision per lens. We find that lens light subtraction prior to modeling is only useful when applied to data sampled from the training prior. If emulated deconvolution is applied to the data prior to modeling, precision improves across all parameters by a factor of 2. Finally, we combine the inferred lens mass models using Bayesian Hierarchical Inference to recover the global properties of the lens sample with less than 1% bias.

Venkatraman, Padmavathi [Illinois U., Urbana; KIPA↗

Spectral reflectance properties of black chrome for use as a solar selective coating

The NASA-Lewis Research Center has determined that a widely available commercially electroplated decorative finish known as black chrome has desirable solar selective properties. The spectral reflectance properties of a commercially prepared black chrome on steel were measured. Values are presented for reflectance of the black chrome, and compared with the reflectance of black paint (Nextel) and with two available samples of black nickel which had been prepared for solar selective properties. The reflectance of black chrome, of the two black nickels, and of black paint integrated over the solar spectrum for air mass 2 were 0.132, 0.123, 0.133, and 0.033, respectively. The reflectance of the black chrome, two black nickels, and of the black paint integrated over the blackbody spectrum for 250 F from 3 to 15 microns are 0.912, 0.934, 0.891, and 0.033, respectively. These reflectance measurements indicate absorptivity-to-emissivity values of 9.8, 13.8, 8.0, and 1.00, respectively.

Mcdonald, G. E.↗

Spectral reflectance properties of black chrome for use as a solar selective coating

The NASA-Lewis Research Center has determined that a widely available commercially electroplated decorative finish known as black chrome has desirable solar selective properties. Black chrome electroplated coating has high absorbtance in the solar spectrum and low emissivity in the 250 F blackbody thermal spectrum. The spectral reflectance properties of a commercially prepared black chrome on steel have been measured. Values are presented for reflectance of the black chrome, and compared with the reflectance of black paint and with two available samples of black nickel which had been prepared for solar selective properties. The reflectance of black chrome, of the two black nickels, and of black paint integrated over the solar spectrum for air mass 2 were 0.132, 0.123, 0.133, and 0.033, respectively. The reflectance of the black chrome, two black nickels, and of the black paint integrated over the blackbody spectrum for 250 F from 3 to 15 microns are 0.912, 0.934, 0.891, and 0.033, respectively. These reflectance measurements indicate absorptivity-to-emissivity values of 9.8, 13.8, 8.0, and 1.00, respectively.

Mcdonald, G. E.↗

Lawrence Livermore National Laboratory Experimental Test Site, Site 300: Soil Study Institutional Review Board #1081 Soil Sampling and Analysis Plan

This Soil Sampling and Analysis Plan (SAP) was prepared by the Environmental Functional Area/Technical Services Department (TSD) of the Environment, Safety & Health (ES&H) Directorate for the Project Management Office (PMO) to collect soil quality data at an area located at Lawrence Livermore National Laboratory’s (LLNL’s) Experimental Test Site, Site 300 (Site 300) (project) (Figures 1 and 2). The purpose of the project is to determine the chemical and radiological quality of soil in the project area to support feasibility and design of future improvements. This SAP identifies chemicals of concern and describes the procedures for collection and analysis of environmental samples, and evaluation of analytical data (chemical and radiological) to determine the reuse potential of shallow soil at the project area. This SAP follows the criteria established in LLNL’s Soils Screening and Management Plan (SSMP) (LLNL 2022), which is consistent with U.S. Environmental Protection Agency (EPA) guidance for developing Data Quality Objectives for environmental data (EPA 2006) and the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) guidance (U.S. NRC, U.S. EPA, U.S. DOE, U.S. DOD 2000). The scope of this SAP is based on preliminary design information provided by PMO.

54 ENVIRONMENTAL SCIENCES↗

Description of the containerless melting of glass in low gravity

A brief description is given of a single-axis, acoustic levitator/furnace apparatus used to position, heat, melt, and quench multicomponent oxide, glass-forming compositions in low gravity. This apparatus is capable of processing eight approximately spherical samples (about 6 mm diameter) at temperatures up to 1550 C in a dry air atmosphere. Results are also presented for a containerless melting experiment conducted on SPAR VI where a ternary CaO-Ga2O3-SiO2 composition was levitated and quenched to a glass. Selected properties of the glass prepared on SPAR VI are compared with the properties of glass samples of identical composition prepared on earth.

Ray, C. S.↗

An Innovative High Throughput Genome Releaser for Rapid and Efficient PCR Screening

High-throughput PCR screening is vital in synthetic biology and metabolic engineering as it allows researchers to rapidly analyze and detect numerous targeted genetic mutation in the genome. Current challenges for high-throughput PCR screening in synthetic biology include efficiently preparing genomic DNA, optimizing protocols for diverse sample types, managing contamination risks, and effectively analyzing the large volumes of data generated while ensuring consistent and accurate results. In this study, we present the development of a High Throughput Genome Releaser (HTGR), an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed based on a squash method for rapid, cost-effective, and efficient DNA release, optimized for subsequent PCR reactions. After experimenting with various synthetic materials, we selected a plastic that closely replicates the smooth surface and compression properties of microscope slides, ensuring reliable performance. We engineered a device featuring a 96-Well Plate and a shear applicator, operable both manually and automatically, and compatible with standard liquid-handling robot platform. This compatibility enhances ease of use in high-throughput PCR workflows. Additionally, we developed software to support its automatic functions. Our results demonstrated that the specially engineered 96-Well Plate and HTGR can effectively squash fungal spores , which release enough genome DNA for PCR screening. The genome releaser facilitates the preparation of PCR-amplifiable genomic DNA substrate from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells, which could significantly advance biomanufacturing processes.

Yuan, Guoliang [BATTELLE (PACIFIC NW LAB)]↗

Restricted and Uncontained: Health Care and Public Health Considerations in the Event of Loss of Containment During the Restricted Earth Return of Extraterrestrial Samples

The normal scope of an adequate public health response to released biological material is framed by working with biological vectors with known pathogenicity and virulence. Defining the scope of a response to the release of biological material with unknown pathogenicity and virulence enters into a novel and yet to be framed domain. A current case, the case of returning samples from a location other than Earth, extraterrestrial samples from a location such as Mars, which may harbor life as we know it, requires framing a public health response. An unintentional release of biological material with unknown pathogenicity and virulence may occur when biological containment mechanisms in the Earth-returning transport method are lost. This paper raises initial public health and healthcare response questions during a return of extraterrestrial samples to Earth, in the event of its release from biological containment mechanisms: How does the public health community prepare for a response when there is release of samples that may contain potential extraterrestrial organisms from a planetary body or hardy terrestrial organisms surviving a round trip? If a mishap occurs during the return of these samples, what considerations need to be made to confine, decontaminate, and collect material in regions around the mishap? How will the public health community work with relevant government organizations to prepare the general public? The unknowns of exposure, potential extraterrestrial pathogenicity, and decontamination approaches, underscore gaps in biopreparedness for this novel case from the federal to local levels.

Betsy Pugel↗

Reactive control and reasoning assistance for scientific laboratory instruments

Scientific laboratory instruments that are involved in chemical or physical sample identification frequently require substantial human preparation, attention, and interactive control during their operation. Successful real-time analysis of incoming data that supports such interactive control requires: (1) a clear recognition of variance of the data from expected results; and (2) rapid diagnosis of possible alternative hypotheses which might explain the variance. Such analysis then aids in decisions about modifying the experiment protocol, as well as being a goal itself. This paper reports on a collaborative project at the NASA Ames Research Center between artificial intelligence researchers and planetary microbial ecologists. Our team is currently engaged in developing software that autonomously controls science laboratory instruments and that provides data analysis of the real-time data in support of dynamic refinement of the experiment control. the first two instruments to which this technology has been applied are a differential thermal analyzer (DTA) and a gas chromatograph (GC). coupled together, they form a new geochemicstry and microbial analysis tool that is capable of rapid identification of the organiz and mineralogical constituents in soils. The thermal decomposition of the minerals and organics, and the attendance release of evolved gases, provides data about the structural and molecular chemistry of the soil samples.

Thompson, David E.↗

Sample Curation in Support of the OSIRIS-REx Asteroid Sample Return Mission

The OSIRIS-REx asteroid sample return mission launched to asteroid Bennu Sept. 8, 2016. The spacecraft will arrive at Bennu in late 2019, orbit and map the asteroid, and perform a touch and go (TAG) sampling maneuver in July 2020. After sample is stowed and confirmed the spacecraft will return to Earth, and the sample return capsule (SRC) will land in Utah in September 2023. Samples will be recovered from Utah [2] and then transported and stored in a new sample cleanroom at NASA Johnson Space Center in Houston [3]. The materials curated for the mission are described here. a) Materials Archive and Witness Plate Collection: The SRC and TAGSAM were built between March 2014 and Summer of 2015, and instruments (OTES,OVIRS, OLA, OCAMS, REXIS) were integrated from Summer 2015 until May 2016. A total of 395 items were received for the materials archive at NASA-JSC, with archiving finishing ~30 days after launch (with the final archived items being related to launch operations)[4]. The materials fall into several general categories including metals (stainless steel, aluminum, titanium alloys, brass and BeCu alloy), epoxies, paints, polymers, lubricants, non-volatile-residue samples (NVR), sapphire, and various miscellaneous materials. All through the ATLO process (from March 2015 until late August 2016) contamination knowledge witness plates (Si wafer and Al foil) were deployed in the various cleanrooms in Denver and KSC to provide an additional record of particle counts and volatiles that is archived for current and future scientific studies. These plates were deployed in roughly monthly increments with each unit containing 4 Si wafers and 4 Al foils. We archived 128 individual witness plates (64 Si wafers and 64 Al foils); one of each witness plate (Si and Al) was analyzed immediately by the science team after archiving, while the remaining 3 of each are archived indefinitely. Information about each material archived is stored in an extensive database at NASA-JSC, and key summary information for each will be presented in an online catalog. b) Bulk Asteroid sample: The Touch and Go Sampling Mechanism (TAGSAM) head will contain up to 1.5 kg of asteroid material. Upon return to Earth, the TAGSAM head with the sample canister will be subjected to a nitrogen purge and then opened in a nitrogen cabinet in Houston. Once the TAGSAM head is removed from the canister, it will be dis-assembled slowly and carefully under nitrogen until the sample can be removed for processing in a dedicated nitrogen glovebox. Bennu surface samples are expected to be sub-cm sized, based on thermal infrared and radar polarization ratio measurements [1]. The upper limit on material collected by the TAGSAM head is ~2 cm. Therefore, we will be prepared to handle, subdivide, and characterize materials of a wide grain size (from ~10 m to 2 cm), and for both organic (UV fluorescence) and inorganic (SEM, FTIR, optical) properties. Representative portions of the bulk sample will be prepared for JAXA (0.5 %; see also [5]) and Canadian Space Agency (4%), with the remaining divided between the science team (<25%) and archived for future studies (NASA) (>75%). c) Contact Pad samples: The base of the TAGSAM head contains 24 contact pads that are designed to trap the upper surface layer of material and thus offer an opportunity to study asteroid samples that have resided at the very top surface of the regolith. Asteroid material is trapped on the pads in spring steel Velcro hooks, and material will have to be removed from these pads by curation specialists in the lab. d) Hardware: Some canister and SRC hardware items will contain information that will be important to understanding the collected samples, including the canister gas filter, temperature strips, flight witness plates, and the TAGSAM and canister parts that might have adhering dust grains. Some challenges remaining for both bulk sample and contact pad samples include: i) working with intermediate size range (200 to 500 micron) samples - a size range NASA has not previously worked in such detail; ii) techniques for removal of contact pad material from the spring steel hooks, iii) static electrical effects of dust sized particles during sample handling and curation is likely to be significant, and iv) the TAGSAM head and associated canister hardware will undoubtedly be coated with fine adhering dust grains from Bennu. In the case of collection of a large bulk sample mass, the adhering dust grains may be of lower priority. If a small sample mass is returned, the adhering dust may attain a higher priority, so recovery of adhering dust grains is an additional challenge to consider. In the year leading up to sample return we plan a variety of sample handling rehearsals that will enables the curation team to be prepared for many new aspects posed by this sample suite.

Righter, Kevin↗

High-resolution analysis of clay minerals and amorphous materials in martian analog environments

Mudrocks and mud-sized sediments (i.e., silt to clay) dominate the surface of Earth and Mars. These fine-grained sediments preserve a rich history of sedimentary processes from source to sink and shed light on ancient climates. However, both the physical and chemical nature of these materials make them difficult to fully characterize with traditional laboratory techniques. Here, we explore a cross-disciplinary and high-resolution approach using synchrotron radiation for X-ray diffraction, pair distribution function analysis, and submicrometer-scale X-ray fluorescence, combined with transmission electron microscopy, to better understand the nanostructure and composition of mud-sized sediments from a glacio-fluvial watershed in southwest Iceland. Our results demonstrate that sediments in the cold and wet climate of Iceland are more altered than previously thought, as evidenced by the identification of kaolinite and mixed-layer kaolinite-smectite. Additionally, sediments are enriched in amorphous materials and nanocrystalline phases, as determined from grain morphologies and compositions consistent with allophane, hisingerite, ferrihydrite, and halloysite. These alteration products are present as intimate mixtures that vary across depositional sites, demonstrating the dynamic nature of the secondary assemblage from source to sink. This work has implications for Mars, where, for example, basalt-sourced sedimentary rocks from Gale crater are abundant in clay minerals and amorphous materials. Finally, this work underpins the importance of using high-resolution techniques, a coordinated methodology, and developing innovative approaches for future planetary sample return missions (e.g., Mars sample return).

36 MATERIALS SCIENCE↗

Safeguards Technolgy Development Program FY2023 Mid-Year Report

We will develop specific aspects of ultra-high-resolution microcalorimetry that support IAEA NML needs in preparation for transfer of the technology. Two techniques will be considered: gamma spectroscopy for nondestructive isotopic analysis of milligram- to gram-scale uranium and plutonium samples, and decay energy spectroscopy (DES) for isotopic analysis of specially prepared nanogram- to microgram-scale samples of alpha decaying actinides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

OSIRIS-REx Orbit Trim Strategy

One of the more challenging aspects of the trajectory design for the OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer) mission at asteroid Bennu was maneuvering while in orbit. The orbital dynamics were highly perturbed by various sources, most notably solar radiation pressure, which degraded accuracy of long term predictions of the spacecraft’s location in orbit. Generally, the Navigation team had to solve three separate issues: correcting a perturbed orbit, changing to a different orbit, or phasing the or bitto place the spacecraft at a specific location at a specific time. The team composed a common framework using up to two maneuvers that could solve all of these problems using an identical schedule that allowed for consistent planning long before the final trajectory could be designed. This orbit trim strategy was successfully used for the first time in the Orbital B phase of the mission to maximize the duration of usable observing geometry in a time-variable orbit with strict operational limits. It was used an additional 3 times throughout the mission to adjust and/or change the orbit, most notably altering the orbit in the weeks prior to the successful Touch-And-Go (TAG)sample collection attempt. This same strategy was used to phase the orbit a total 10 times in preparation for each of the science sorties over potential sample sites, the TAG Rehearsals, and TAG. The trim strategy was demonstrated to be robust and performed exceptionally well in all aspects, which proved critical to a successful sample collection.

Daniel R. Wibben↗

High-throughput single-cell transcriptomics of bacteria using combinatorial barcoding

Microbial split-pool ligation transcriptomics (microSPLiT) is a high-throughput single-cell RNA sequencing method for bacteria. With four combinatorial barcoding rounds, microSPLiT can profile transcriptional states in hundreds of thousands of Gram-negative and Gram-positive bacteria in a single experiment without specialized equipment. As bacterial samples are fixed and permeabilized before barcoding, they can be collected and stored ahead of time. During the first barcoding round, the fixed and permeabilized bacteria are distributed into a 96-well plate, where their transcripts are reverse transcribed into cDNA and labeled with the first well-specific barcode inside the cells. The cells are mixed and redistributed two more times into new 96-well plates, where the second and third barcodes are appended to the cDNA via in-cell ligation reactions. Finally, the cells are mixed and divided into aliquot sub-libraries, which can be stored until future use or prepared for sequencing with the addition of a fourth barcode. It takes 4 days to generate sequencing-ready libraries, including 1 day for collection and overnight fixation of samples. Here, the standard plate setup enables single-cell transcriptional profiling of up to 1 million bacterial cells and up to 96 samples in a single barcoding experiment, with the possibility of expansion by adding barcoding rounds. The protocol requires experience in basic molecular biology techniques, handling of bacterial samples and preparation of DNA libraries for next-generation sequencing. It can be performed by experienced undergraduate or graduate students. Data analysis requires access to computing resources, familiarity with Unix command line and basic experience with Python or R.