Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rupture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Design and biocompatibility of endovascular aneurysm filling devices

We report that the rupture of an intracranial aneurysm, which can result in severe mental disabilities or death, affects approximately 30,000 people in the United States annually. The traditional surgical method of treating these arterial malformations involves a full craniotomy procedure, wherein a clip is placed around the aneurysm neck. In recent decades, research and device development have focused on new endovascular treatment methods to occlude the aneurysm void space. These methods, some of which are currently in clinical use, utilize metal, polymeric, or hybrid devices delivered via catheter to the aneurysm site. In this review, we present several such devices, including those that have been approved for clinical use, and some that are currently in development. We present several design requirements for a successful aneurysm filling device and discuss the success or failure of current and past technologies. Lastly, we also present novel polymeric based aneurysm filling methods that are currently being tested in animal models that could result in superior healing.

47 OTHER INSTRUMENTATION↗

Antibiotic Treatment Prior to Injury Abrogates the Detrimental Effects of LPS in STR/ort Mice Susceptible to Osteoarthritis Development

Post traumatic osteoarthritis (PTOA) is a form of secondary osteoarthritis (OA) that develops in ~50% of cases of severe articular joint injuries and leads to chronic and progressive degradation of articular cartilage and other joint tissues. PTOA progression can be exacerbated by repeated injury and systemic inflammation. Few studies have examined approaches for blunting or slowing down PTOA progression with emphasis on systemic inflammation; most arthritis studies focused on the immune system have been in the context of rheumatoid arthritis. To examine how the gut microbiome affects systemic inflammation during PTOA development, we used a chronic antibiotic treatment regimen starting at weaning for 6 weeks before anterior cruciate ligament (ACL) rupture in STR/ort mice combined with lipopolysaccharide (LPS)-induced systemic inflammation. STR/ort mice develop spontaneous OA as well as a more severe PTOA phenotype than C57Bl/6J mice. By 6 weeks post injury, histological examination showed a more robust cartilage staining in the antibiotic-treated (AB) STR/ort mice than in the untreated STR/ort controls. Furthermore, we also examined the effects of AB treatment on systemic inflammation and found that the effects of LPS administration before injury are also blunted by AB treatment in STR/ort mice. The AB- or AB+LPS-treated STR/ort injured joints more closely resembled the C57Bl/6J VEH OA phenotypes than the vehicle- or LPS-treated STR/ort, suggesting that antibiotic treatment has the potential to slow disease progression and should be further explored therapeutically as prophylactic post injury.

60 APPLIED LIFE SCIENCES↗

SOST/Sclerostin Improves Posttraumatic Osteoarthritis and Inhibits MMP2/3 Expression After Injury: SOST OVEREXPRESSION IMPROVES PTOA OUTCOMES

Patients with anterior cruciate ligament (ACL) rupture are two times as likely to develop posttraumatic osteoarthritis (PTOA). Annually, there are ~900,000 knee injuries in the United States, which account for ~12% of all osteoarthritis (OA) cases. PTOA leads to reduced physical activity, deconditioning of the musculoskeletal system, and in severe cases requires joint replacement to restore function. Therefore, treatments that would prevent cartilage degradation post-injury would provide attractive alternatives to surgery. Sclerostin (Sost), a Wnt antagonist and a potent negative regulator of bone formation, has recently been implicated in regulating chondrocyte function in OA. To determine whether elevated levels of Sost play a protective role in PTOA, we examined the progression of OA using a noninvasive tibial compression overload model in SOST transgenic (SOST TG ) and knockout (Sost -/- ) mice. Here we report that SOST TG mice develop moderate OA and display significantly less advanced PTOA phenotype at 16 weeks post-injury compared with wild-type (WT) controls and Sost -/- . In addition, SOST TG built ~50% and ~65% less osteophyte volume than WT and Sost -/- , respectively. Quantification of metalloproteinase (MMP) activity showed that SOSTTG had ~2-fold less MMP activation than WT or Sost-/-, and this was supported by a significant reduction in MMP2/3 protein levels, suggesting that elevated levels of SOST inhibit the activity of proteolytic enzymes known to degrade articular cartilage matrix. Furthermore, intra-articular administration of recombinant Sost protein, immediately post-injury, also significantly decreased MMP activity levels relative to PBS-treated controls, and Sost activation in response to injury was TNFα and NF-κB dependent. These results provide in vivo evidence that sclerostin functions as a protective molecule immediately after joint injury to prevent cartilage degradation.

Endocrinology & Metabolism↗

Spark plasma sintering preparation of reference targets for field spectroscopy on Mars

We propose spark plasma sintering (SPS) as a technique to prepare reference targets for Raman and other spectroscopy instruments involved in future space missions and more generally in–field work. We have tested the effect of SPS on different international standards that are available in the form of minerals and rocks powders. Advantages and potential issues of SPS were considered by analyzing the Raman signal and mechanical properties of the sintered targets. The shape is well controlled; the rupture toughness is enhanced, and the homogeneous distribution of the mineral phases is verified. In conclusion, a suite of calibration targets has thus been implemented for the SuperCam instrument on the National Aeronautics and Space Administration Mars 2020 rover, and SPS may be preferred for future missions as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multiscale anisotropic polymer network model coupled with phase field fracture

The study of polymers has continued to gain substantial attention due to their expanding range of applications, spanning essential engineering fields to emerging domains like stretchable electronics, soft robotics, and implantable sensors. These materials exhibit remarkable properties, primarily stemming from their intricate polymer chain network, which, in turn, increases the complexity of precisely modeling their behavior. Especially for modeling elastomers and their fracture behavior, accurately accounting for the deformations of the polymer chains is vital for predicting the rupture in highly stretched chains. Despite the importance, many robust multiscale continuum frameworks for modeling elastomer fracture tend to simplify network deformations by assuming uniform behavior among chains in all directions. Recognizing this limitation, our study proposes a multiscale fracture model that accounts for the anisotropic nature of elastomer network responses. At the microscale, damage in the chains is assumed to be driven by both the chain's entropy and the internal energy due to molecular bond distortions. In order to bridge the stretching in the chains to the macroscale deformation, we employ the maximal advance path constraint network model, inherently accommodating anisotropic network responses. As a result, chains oriented differently can be predicted to exhibit varying stretch and, consequently, different damage levels. To drive macroscale fracture based on damages in these chains, we utilize the micromorphic regularization theory, which involves the introduction of dual local-global damage variables at the macroscale. The macroscale local damage variable is obtained through the homogenization of the chain damage values, resulting in the prediction of an isotropic material response. The macroscale global damage variable is subjected to nonlocal effects and boundary conditions in a thermodynamically consistent phase field continuum formulation. Moreover, the total dissipation in the system is considered to be mainly due to the breaking of the molecular bonds at the microscale. To validate our model, we employ the double-edge notched tensile test as a benchmark, comparing simulation predictions with existing experimental data. Additionally, to enhance our understanding of the fracturing process, we conduct uniaxial tensile experiments on a square film made up of polydimethylsiloxane (PDMS) rubber embedded with a hole and notches and then compare our simulation predictions with the experimental observations. Furthermore, we visualize the evolution of stretch and damage values in chains oriented along different directions to assess the predictive capacity of the model. In conclusion, the results are also compared with another existing model to evaluate the utility of our model in accurately simulating the fracture behavior of rubber-like materials.

42 ENGINEERING↗

Evaluating and predicting molecular mechanisms of adhesive degradation during field and accelerated aging of photovoltaic modules

Extending photovoltaic (PV) module lifetimes beyond 30 years is a goal of significant priority. A challenge that must first be addressed, however, is the development of a predictive reliability model that captures the synergy of terrestrial stressors on module degradation, particularly at encapsulant interfaces. Using a metrology designed specifically for PV modules, a comprehensive study of the widely used ethylene vinyl acetate encapsulant was performed in which encapsulant adhesion was evaluated as a function of environmental stressors (UV exposure, temperature, and humidity) for modules aged both under accelerated lab and internationally located field conditions for months to nearly 3 decades. Mechanical and chemical characterization methods are combined with fundamental polymer reaction engineering to unravel the degradation processes active at the molecular scale that lead to encapsulant delamination. An analytical and modular model framework is put forward enabling the prediction of long-term PV module durability, starting from fundamental principles at the molecular level and explicitly accounting for bond rupture events in the bulk encapsulant and at the encapsulant interfaces. Successful parameter tuning to adhesion data indicates a dominant occurrence of deacetylation, β-scission, and hydrolytic depolymerization, respectively. The model contributes to the longstanding challenge of predicting module lifetimes in any geographic location while minimizing time-consuming and costly aging studies.

14 SOLAR ENERGY↗

Tailoring the mechanical properties of nanoparticle networks that encompass biomimetic catch bonds

Biological “catch” bonds display the distinctive attribute that the bond lifetime can increase under an applied force. Insertion of biomimetic catch bonds into hybrid materials could lead to composites that exhibit remarkable mechanical properties. We model the tensile behavior of polymer-grafted nanoparticle (PGN) networks interconnected by a mixture of catch bonds and conventional “slip” bonds, whose lifetimes decrease with force. We formulate a kinetic master equation that provides the complete probabilistic description of a system of two PGNs. The master equation is used to analyze the parameter space that determines the rupture behavior of the catch bonds in the two-particle system. We then utilize two exemplary sets of catch bond parameters in three-dimensional computer simulations of larger PGN networks under strain-controlled tensile deformation. We demonstrate that the strain at break and toughness of the networks can be altered by “tuning” the attributes of the catch bonds and varying the fraction of catch bonds in the network. We show that networks encompassing the catch bonds could exhibit a several-fold increase in the strain-at-break and toughness relative to those interconnected solely by the slip bonds. Our studies can provide valuable guidelines for tailoring the mechanical properties of novel, bio-inspired nanocomposites.

36 MATERIALS SCIENCE↗

Using transparent fish to observe barotrauma associated with downstream passage through hydropower turbines

During downstream passage of hydroelectric facilities, fish can be injured by rapid decompression; this is especially noted during hydroturbine passage. The rapid decrease in pressure can cause barotrauma as undissolved gas expands according to Boyle’s law. However, it is difficult to see barotrauma occurring within the body of the fish in real time. In order to determine if transparent fish could provide greater insight into barotrauma, five species of transparent tropical fish were exposed to rapid decompressions so internal injuries could be viewed noninvasively. Before and after photos were taken to review the injuries and high speed video allowed observations of barotrauma pathways in vivo. High speed video recordings show the expansion of the swim bladder and subsequent release of gas through the mouth and gills, and into the body cavity when the swim bladder ruptured. Post-decompression photographs show that many internal injuries were visible and included hemorrhaging and the presence of emphysema within the body cavity and tissues. These observations provide new opportunities to understand the pathways and effects of barotrauma.

13 HYDRO ENERGY↗

Incipient and Progressive Damage in Polyethylene Under Extreme Tensile Conditions

The Dynamic-Tensile-Extrusion (Dyn-Ten-Ext) test was developed at LANL by Gray and coworkers to probe the tensile response of materials at large strains (>1) and high strain-rates (>1000/s) by firing projectiles through a conical die at 300-700 m/s. This technique has recently been applied to various polymers, such as the fluoropolymers PTFE (Teflon) and the chemically similar PCTFE, which respectively exhibited catastrophic fragmentation and distributed dynamic necking. This work details investigations of the Dyn-Ten-Ext response of high density polyethylene, both to failure and sub-critical conditions. At large extrusion ratios ({approx}7.4) and high velocities, such as those previously employed, HDPE catastrophically fragmented in a craze-like manner in the extruded jet. At more modest extrusion ratios and high velocities the specimen extruded a stable jet that ruptured cleanly, and at lower velocities was recovered intact after sustaining substantial internal damage. Thermomechanical finite element simulations showed that the damage corresponded to a locus of shear stress in the presence of hydrostatic tension. X-ray computed tomography corroborated the prediction of a shear damage mechanism by finding the region of partially damaged material to consist of macroscopic shear-mode cracks nearly aligned with the extrusion axis, originating from the location of damage inception.

36 MATERIALS SCIENCE↗

Cystic Echinococcal Liver Disease: New Insights into an Old Disease and an Algorithm for Therapy Planning

Human cystic echinococcosis (CE) continues to be a major health problem in developing countries. A review of current literature discloses four alternatives for the management of active CE, consisting of surgery, percutaneous treatment (PT), chemotherapy, and follow-up without intervention, but no clear guidelines for directing patients to the different management options. Palliation of symptoms or prevention of complications is the main rationale for the treatment of CE. Surgery has long been considered as the gold standard treatment. However, a meta-analysis comparing the clinical outcomes of patients treated with PT with those of a control group treated with surgery found PT to be more effective, safer, and cheaper. Medical therapy is considered to be ineffective when the criterion of success is defined as the disappearance of the lesion. However, medical therapy seems to be effective when the goal of therapy is defined as the prevention of complications in asymptomatic patients. We propose an algorithm for therapy planning in CE where the first line of therapy for patients with active lesions is PT. Patients with lesions unsuitable for PT are directed to surgery if they are symptomatic, have complicated lesions or have lesions that are prone to rupture. Asymptomatic patients with uncomplicated lesions are directed to medical therapy. Medical therapy failures are redirected to surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Therapy of Pseudoaneurysms of the Trunk: Application of Thrombin

Thrombin injection has been proven to be successful in postcatheterization pseudoaneurysms. However, there are only a few reports on the treatment of pseudoaneurysms of the trunk. We report our first experiences using a percutaneous as well as an endovascular access. Eight iatrogenic pseudoaneurysms of the trunk (aorta, n = 4; pulmonary artery, n = 1; gastroduodenal artery, n = 1; left gastric artery, n = 1, renal artery, n = 1) were treated either percutaneously using CT guidance (n = 3) or via an endovascular access (n = 5). Noninvasive control angiograms were performed at day 1 and weeks 1 and 3 by either CT or MR angiography. The total volume of the pseudoaneurysms was 31.2 {+-} 23.1 ml on average, with a mean volume of the perfused aneurysmal lumen of 12.9 {+-} 7.2 ml. The maximum diameter was 4.1 {+-} 1.39 cm on average. In each case, the aneurysmal neck was not wider than 2 mm. One pseudoaneurysm occluded spontaneously following selective catheterization. The remaining pseudoaneurysms were successfully treated by injection of 765 {+-} 438.1 IU thrombin. In one individual, a nontarget embolization occurred, as well as an intervention-associated rupture of a pseudoaneurysm. High-grade stenoses of the donor artery were found in a different case. Only once was the endoluminal access converted to a percutaneous one. Thrombin injection might be a future first-line treatment of vascular lesions such as pseudoaneurysms of the trunk. In our experience both percutanous and endoluminal access are technically feasible and safe. However, further experiences are mandatory, especially concerning the question of dosage and long-term results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Interventional and Surgical Treatment for Acute Aortic Type A Dissection

Surgical repair and endovascular stent-graft placement are both therapies for thoracic aortic dissection. A combination of these two approaches may be effective in patients with type A dissection. In this study, we evaluated the prognosis of this combined technique. From December 2003 to December 2006, 15 patients with type A dissection were admitted to our institute; clinical data were retrospectively reviewed. Follow-up was performed at discharge and approximately 12 months after operation. Endovascular stent-graft placement by interventional radiology and surgical repair for reconstruction of aortic arch was performed in all patients. Total arch replacement for distal arch aneurysm was carried out under deep hypothermia with circulatory arrest; antegrade-selected cerebral perfusion was used for brain protection. Four patients concomitantly received a coronary artery bypass graft. Hospital mortality rate was 6.7%; the patient died of cerebral infarction. Neurological complications developed in two patients. Multi-detector-row computed tomography scans performed before discharge revealed complete thrombosis of the false lumen in six patients and partial thrombosis in eight patients. At the follow-up examination, complete thrombosis was found in another three patients, aortic rupture, endoleaks, or migration of the stent-graft was not observed and injuries of peripheral organs or anastomotic endoleaks did not occur. For patients with aortic type A dissection, combining intervention and surgical procedures is feasible, and complete or at least partial thrombosis of the false lumen in the descending aorta can be achieved. This combined approach simplified the surgical procedures and shortened the circulatory arrest time, minimizing the necessity for further aortic operation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Internal Iliac Artery: Cost-Effectiveness of Two Different Techniques

The purpose of this study was to compare the cost-effectiveness of coils versus the Amplatzer Vascular Plug (AVP) for occlusion of the internal iliac artery (IAA). Between 2002 and January 2006, 13 patients (mean age 73 {+-} 13 years) were referred for stent-grafting of abdominal aortic aneurysm (n = 6); type I distal endoleak (n = 3), isolated iliac aneurysm (n = 3), or rupture of a common iliac aneurysm (n = 1). In all patients, extension of the stent-graft was needed because the distal neck was absent. Two different techniques were used to occlude the IIA: AVP in seven patients (group A) and coil embolization in six patients (group C). Immediate results and direct material costs were assessed retrospectively. Immediate success was achieved in all patients, and simultaneous stent-grafting was successfully performed in two of six patients in group C versus five of seven patients in group A. In all group A patients, a single AVP was sufficient to achieve occlusion of the IIA, accounting for a mean cost of 485 Euro , whereas in group C patients, an average of 7 {+-} 3 coils were used, accounting for a mean cost of 1,745 Euro . Mean average cost savings using the AVP was 1,239 Euro . When IIA occlusion is needed, the AVP allows a single-step procedure at significant cost savings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Stent Grafting After Unsuccessful Surgical Repair of a Mycotic Common Femoral Artery Pseudoaneurysm in a Drug Abuser

Mycotic false aneurysm caused by local arterial injury from attempted intravenous injections in drug addicts remains a challenging clinical problem. The continued increase in drug abuse has resulted in an increased incidence of this problem, particularly in high-volume urban centres. In the drug-abusing population, mycotic arterial pseudoaneurysms most often occur because of missed venous injection and are typically seen in the groin, axilla, and antecubital fossa. Mycotic aneurysms may lead to life-threatening haemorrhage, limb loss, sepsis, and even death. Any soft-tissue swelling in the vicinity of a major artery in an intravenous drug abuser should be suspected of being a false aneurysm until proven otherwise and should prompt immediate referral to a vascular surgeon for investigation and management. We report a case of rupturing mycotic pseudoaneurysm of the left common femoral artery treated by surgical resection followed by vessel reconstruction with autologous material. Unfortunately, at the time of discharge a sudden leakage from the vein graft anastomosis occurred, with subsequent massive bleeding, and required emergent endovascular covered stenting. To the best of our knowledge, this is the first reported case of femoral artery bleeding in a drug abuser treated by stent graft placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stent-Graft Repair of a Large Cervical Internal Carotid Artery Pseudoaneurysm Causing Dysphagia

Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment Strategies in Aortoiliac Occlusion

The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Interventions Via a Transradial Approach for Dysfunctional Brescia-Cimino Fistulas

The transradial artery approach to angioplasty has rarely been reported as a method for treating dysfunctional Brescia-Cimino fistulas. This study evaluated the feasibility, safety, and 1-year efficacy of this method for treating dysfunctional Brescia-Cimino fistulas. We retrospectively evaluated 154 consecutive procedures in 131 patients (age, 58.3 {+-} 11.6 years; male, 48.1%) who underwent the transradial approach in dysfunctional Brescia-Cimino fistulas in the 1-year period after the procedure. The operator determined the use of a regular or a cutting balloon (two cases) in combination with urokinase injection (one case) or catheter thromboaspiration. Radial artery puncture was successful in all cases. Fifty-two cases (33.8%) had totally occluded fibrotic lesions. The overall anatomic success rate and clinical success rate were 61% (94/154) and 81.1% (125/154), respectively. In cases with a totally occluded fibrotic lesion, the clinical success rate was 46%. Successful intervention was associated with a significant reduction in the radial arterial systolic and diastolic pressures. There were no complications of symptomatic arterial embolization or pulmonary embolism, and one complication of venous rupture was successfully treated by compression. The primary patency rates based on intention-to-treat were 75.3% at 30 days and 39.0% at 1 year after the procedure. Excluding the cases with a totally occluded lesion, the clinical success rate was 99% (101/102) and the primary patency rates were 84.3% (86/102) and 52.0% (53/102) at 3 months and 1 year after the procedure, respectively. In conclusion, the transradial approach is a feasible, safe, and effective alternative for catheter intervention for dysfunctional Brescia-Cimino fistulas. Its success rate in cases with a totally occluded fibrotic lesion is unsatisfactory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recanalization of Splenic Artery Aneurysm After Transcatheter Arterial Embolization Using N-Butyl Cyanoacrylate

A 65-year-old woman who had been diagnosed as having microscopic polyangiitis developed sudden abdominal pain and entered a state of shock. Abdominal CT showed massive hemoperitoneum, and emergent angiography revealed a ruptured splenic artery aneurysm. After direct catheterization attempts failed due to tortuous vessels and angiospasm, transcatheter arterial embolization using an n-butyl cyanoacrylate (NBCA)-lipiodol mixture was successfully performed. Fifty days later, the patient developed sudden abdominal pain again. Repeated angiography demonstrated recanalization of the splenic artery and splenic artery aneurysm. This time, the recanalized aneurysm was embolized using metallic coils with the isolation method. Physicians should keep in mind that recanalization can occur after transcatheter arterial embolization using N-butyl cyanoacrylate, which has been used as a permanent embolic agent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗