Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Ultrasonic imaging of materials under unconventional circumstances

This paper reflects the contents of the plenary talk given by Nico Felicien Declercq. “Ultrasonic Imaging of materials” covers a wide technological area with main purpose to look at and to peek inside materials. In an ideal world one would manage to examine materials like a clairvoyant. Fortunately this is impossible hence nature has offered sufficient challenges to mankind to provoke curiosity and to develop science and technology. Here we focus on the appearance of certain undesired physical effects that prohibit direct imaging of materials in ultrasonic C-scans. Furthermore we try to make use of these effects to obtain indirect images of materials and therefore make a virtue of necessity. First we return to one of the oldest quests in the progress of mankind: how thick is ice? Our ancestors must have faced this question early on during migration to Northern Europe and to the America’s and Asia. If a physicist or engineer is not provided with helpful tools such as a drill or a device based on ultrasound, it is difficult to determine the ice thickness. Guided waves, similar to those used for nondestructive testing of thin plates in structural health monitoring can be used in combination with the human ear to determine the thickness of ice. To continue with plates, if an image of its interior is desired high frequency ultrasonic pulses can be applied. It is known by the physicist that the resolution depends on the wavelength and that high frequencies usually result in undesirably high damping effects inhibiting deep penetration into the material. To the more practical oriented engineer it is known that it is advantageous to polish surfaces before examination because scattering and diffraction of sound lowers the image resolution. Random scatterers cause some blurriness but cooperating scatters, causing coherent diffraction effects similar to the effects that cause DVD’s to show rainbow patterns under sunlight, can cause spooky images and erroneous measurements of material properties. However when properly understood, diffraction effects, for instance if one has no other options but to work with frequencies that are fortuitously very effectively diffracted by the surface structure of a material under investigation, can be used to obtain high contract images or to obtain information that would normally be hidden from standard C-scan techniques. Similar contrast enhancement is also obtained for oblique C-scans of composites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Angle sensitive single photon avalanche diode

An ideal light sensor would provide exact information on intensity, timing, location, and angle of incoming photons. Single photon avalanche diodes (SPADs) provide such desired high (single photon) sensitivity with precise time information and can be implemented at a pixel-scale to form an array to extract spatial information. Furthermore, recent work has demonstrated photodiode-based structures (combined with micro-lenses or diffraction gratings) that are capable of encoding both spatial and angular information of incident light. In this letter, we describe the implementation of such a grating structure on SPADs to realize a pixel-scale angle-sensitive single photon avalanche diode (A-SPAD) built in a standard CMOS process. While the underlying SPAD structure provides high sensitivity, the time information of the two layers of diffraction gratings above offers angle-sensitivity. Such a unique combination of SPAD and diffraction gratings expands the sensing dimensions to pave a path towards lens-less 3-D imaging and light-field time-of-flight imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanical detection of electron spin resonance beyond 1 THz

We report the cantilever detection of electron spin resonance (ESR) in the terahertz (THz) region. This technique mechanically detects ESR as a change in magnetic torque that acts on the cantilever. The ESR absorption of a tiny single crystal of Co Tutton salt, Co(NH{sub 4}){sub 2}(SO{sub 4}){sub 2}⋅6H{sub 2}O, was observed in frequencies of up to 1.1 THz using a backward travelling wave oscillator as a THz-wave source. This is the highest frequency of mechanical detection of ESR till date. The spectral resolution was evaluated with the ratio of the peak separation to the sum of the half-width at half maximum of two absorption peaks. The highest resolution value of 8.59 ± 0.53 was achieved at 685 GHz, while 2.47 ± 0.01 at 80 GHz. This technique will not only broaden the scope of ESR spectroscopy application but also lead to high-spectral-resolution ESR imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strong diameter-dependence of nanowire emission coupled to waveguide modes

The emission from nanowires can couple to waveguide modes supported by the nanowire geometry, thus governing the far-field angular pattern. To investigate the geometry-induced coupling of the emission to waveguide modes, we acquire Fourier microscopy images of the photoluminescence of nanowires with diameters ranging from 143 to 208 nm. From the investigated diameter range, we conclude that a few nanometers difference in diameter can abruptly change the coupling of the emission to a specific mode. Moreover, we observe a diameter-dependent width of the Gaussian-shaped angular pattern in the far-field emission. This dependence is understood in terms of interference of the guided modes, which emit at the end facets of the nanowire. Our results are important for the design of quantum emitters, solid state lighting, and photovoltaic devices based on nanowires.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultracold Plasma Expansion in a Magnetic Field

We measure the expansion of an ultracold plasma across the field lines of a uniform magnetic field. We image the ion distribution by extracting the ions with a high-voltage pulse onto a position-sensitive detector. Early in the lifetime of the plasma (<20 {mu}s), the size of the image is dominated by the time-of-flight Coulomb explosion of the dense ion cloud. For later times, we measure the 2D Gaussian width of the ion image, obtaining the transverse expansion velocity as a function of the magnetic field (up to 70 G). We observe that the expansion velocity scales as B{sup -1/2}, explained by a nonlinear ambipolar diffusion model with anisotropic diffusion in two different directions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First flight performance of the Micro-X microcalorimeter X-ray sounding rocket

The flight of the Micro-X sounding rocket on July 22, 2018, marked the first operation of transition-edge sensors and their superconducting quantum interference device readouts in space. Here, the instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia A supernova remnant. Although a rocket pointing malfunction led to no time on-target, data from the flight were used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared with ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum Transfer Learning to Boost Dementia Detection

Dementia is a devastating condition with profound implications for individuals, families, and healthcare systems. Early and accurate detection of dementia is critical for timely intervention and improved patient outcomes. While classical machine learning and deep learning approaches have been explored extensively for dementia prediction, these solutions often struggle with high-dimensional biomedical data and large-scale datasets, quickly reaching computational and performance limitations. To address this challenge, quantum machine learning (QML) has emerged as a promising paradigm, offering faster training and advanced pattern recognition capabilities. This work aims to demonstrate the potential of quantum transfer learning (QTL) to enhance the performance of a weak classical deep learning model applied to a binary classification task for dementia detection. Besides, we show the effect of noise on the QTL-based approach, investigating the reliability and robustness of this method. Using the OASIS 2 dataset, we show how quantum techniques can transform a suboptimal classical model into a more effective solution for biomedical image classification, highlighting their potential impact on advancing healthcare technology.

Bhowmik, Sounak [University of Tennessee, Knoxvill↗

Spatiotemporal imaging and manipulation of surface plasmons

Abstract Surface plasmon polaritons (SPPs) are travelling surface waves that have shown promise for applications in nanophotonics as they provide a direct route toward photon-mediated electrical signal generation – a central paradigm for speeding up and scaling down photonic elements. SPP waves have also generated fundamental interest due to their high-field strength and sub-wavelength confinement, properties that have enabled the surface-enhanced Raman effect. Over the last decade, photoemission electron microscopy (PEEM) has emerged as a pioneering technique for imaging surface electric fields through ultrashort laser pulse mediated electron emission and has therefore become an indispensable tool for characterizing plasmonic phenomena at interfaces in a variety of materials. PEEM offers nanometer spatial resolution and femtosecond temporal resolution, allowing SPPs to be prepared, monitored, and manipulated on the nanometer-femtosecond scale. Through a brief review of recent reports, we aim to introduce PEEM-based SPP imaging and manipulation modalities and highlight their utility in the context of emerging nanoscale and quantum materials science advancements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Infrared Camera

A sensitive infrared camera that observes the blazing plumes from the Space Shuttle or expendable rocket lift-offs is capable of scanning for fires, monitoring the environment and providing medical imaging. The hand-held camera uses highly sensitive arrays in infrared photodetectors known as quantum well infrared photo detectors (QWIPS). QWIPS were developed by the Jet Propulsion Laboratory's Center for Space Microelectronics Technology in partnership with Amber, a Raytheon company. In October 1996, QWIP detectors pointed out hot spots of the destructive fires speeding through Malibu, California. Night vision, early warning systems, navigation, flight control systems, weather monitoring, security and surveillance are among the duties for which the camera is suited. Medical applications are also expected.

Source record↗

Routes to fractality and entropy in Liesegang systems

Liesegang bands are formed when solutions of co-precipitate ions interdiffuse in a 1D gel matrix. In a recent study [R. F. Sultan, Acta. Mech. Sin. 27, 119 (2011)], Liesegang patterns have been characterized as fractal structures. In addition to experimentally obtained patterns, geometric Liesegang patterns were constructed in conformity with the well-known empirical laws. Both mathematical fractal dimensions and box count dimensions for images of PbF{sub 2} and PbI{sub 2} Liesegang patterns have been calculated. Liesegang patterns can also be described by the entropy state function, and categorized as more or less ordered structures. We revisit the relation between entropy and fractal dimension, and apply it to simulated geometrical Liesegang patterns. We have resort to three different routes for the estimation of the entropy of a Liesegang pattern. The HarFA software enabled the calculation of the Hausdorff dimension and the topological entropy, then the information dimension and the Shannon entropy. In a third pathway, analytical calculations were carried out by estimating the probability of occurrence of a fractal element or coverage. The product of Shannon entropy and Boltzmann constant yields the thermodynamic entropy. The values for PbF{sub 2} and PbI{sub 2} Liesegang patterns attained the order of magnitude of the reported Third Law entropies, but yet remained lower, in conformity with the more ordered Liesegang structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography

To maximize sensitivity, it is desirable that ring Positron Emission Tomography (PET) systems dedicated for imaging the breast have a small bore. Unfortunately, due to parallax error this causes substantial degradation in spatial resolution for objects near the periphery of the breast. In this work, a framework for computing and incorporating an accurate system matrix into iterative reconstruction is presented in an effort to reduce spatial resolution degradation towards the periphery of the breast. The GATE Monte Carlo Simulation software was utilized to accurately model the system matrix for a breast PET system. A strategy for increasing the count statistics in the system matrix computation and for reducing the system element storage space was used by calculating only a subset of matrix elements and then estimating the rest of the elements by using the geometric symmetry of the cylindrical scanner. To implement this strategy, polar voxel basis functions were used to represent the object, resulting in a block-circulant system matrix. Simulation studies using a breast PET scanner model with ring geometry demonstrated improved contrast at 45% reduced noise level and 1.5 to 3 times resolution performance improvement when compared to MLEM reconstruction using a simple line-integral model. The GATE based system matrix reconstruction technique promises to improve resolution and noise performance and reduce image distortion at FOV periphery compared to line-integral based system matrix reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transducer selection and application in magnetoacoustic tomography with magnetic induction

As an acoustic receiver, transducer plays a vital role in signal acquisition and image reconstruction for magnetoacoustic tomography with magnetic induction (MAT-MI). In order to optimize signal acquisition, the expressions of acoustic pressure detection and waveform collection are theoretically studied based on the radiation theory of acoustic dipole and the reception pattern of transducer. Pressure distributions are simulated for a cylindrical phantom model using a planar piston transducer with different radii and bandwidths. The proposed theory is also verified by the experimental measurements of acoustic waveform detection for an aluminum foil cylinder. It is proved that acoustic pressure with sharp and clear boundary peaks can be detected by the large-radius transducer with wide bandwidth, reflecting the differential of the induced Lorentz force accurately, which is helpful for precise conductivity reconstruction. To detect acoustic pressure with acceptable pressure amplitude, peak pressure ratio, amplitude ratio, and improved signal to noise ratio, the scanning radius of 5–10 times the radius of the object should be selected to improve the accuracy of image reconstruction. This study provides a theoretical and experimental basis for transducer selection and application in MAT-MI to obtain reconstructed images with improved resolution and definition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bound State of an Electron in a MOS Structure Due to the Spin–Orbit Interaction

It is shown that two electrons situated in a quantum well near a metallic electrode are attracted to each other due to the Bychkov–Rashba spin–orbit interaction (SOI) and electrostatic image forces. For quite accessible values of the characteristic parameters of the system, the effective attraction due to the SOI dominates over the Coulomb repulsion, and the formation of a bielectron becomes possible. The theory of the effect is especially simple and clear in the case of a quantum wire. The binding energy of the electron pair significantly increases under the application of a gate voltage of appropriate polarity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NASA Tech Briefs, April 2006

The topics covered include: 1) Replaceable Sensor System for Bioreactor Monitoring; 2) Unitary Shaft-Angle and Shaft-Speed Sensor Assemblies; 3) Arrays of Nano Tunnel Junctions as Infrared Image Sensors; 4) Catalytic-Metal/PdO(sub x)/SiC Schottky-Diode Gas Sensors; 5) Compact, Precise Inertial Rotation Sensors for Spacecraft; 6) Universal Controller for Spacecraft Mechanisms; 7) The Flostation - an Immersive Cyberspace System; 8) Algorithm for Aligning an Array of Receiving Radio Antennas; 9) Single-Chip T/R Module for 1.2 GHz; 10) Quantum Entanglement Molecular Absorption Spectrum Simulator; 11) FuzzObserver; 12) Internet Distribution of Spacecraft Telemetry Data; 13) Semi-Automated Identification of Rocks in Images; 14) Pattern-Recognition Algorithm for Locking Laser Frequency; 15) Designing Cure Cycles for Matrix/Fiber Composite Parts; 16) Controlling Herds of Cooperative Robots; 17) Modification of a Limbed Robot to Favor Climbing; 18) Vacuum-Assisted, Constant-Force Exercise Device; 19) Production of Tuber-Inducing Factor; 20) Quantum-Dot Laser for Wavelengths of 1.8 to 2.3 micron; 21) Tunable Filter Made From Three Coupled WGM Resonators; and 22) Dynamic Pupil Masking for Phasing Telescope Mirror Segments.

Source record↗

X-Ray Digital Radiography and Computed Tomography Characterization of Targets

The summary of this report is: (1) The Xradia Micro XCT and LLNL CCAT x-ray systems are used to nondestructively characterize a variety of materials, assemblies, and reference standard components; (2) The digital radiograph (DR) and computed tomography (CT) image data may be used for metrology, quality control, and defect detection; and (3) The ability to detect and characterize imperfections leads to improvements in the manufacturing processes for assemblies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Topological Phononic Crystals with One-Way Elastic Edge Waves

We report here a new type of phononic crystals with topologically nontrivial band gaps for both longitudinal and transverse polarizations, resulting in protected one-way elastic edge waves. In our design, gyroscopic inertial effects are used to break the time-reversal symmetry and realize the phononic analogue of the electronic quantum (anomalous) Hall effect. We investigate the response of both hexagonal and square gyroscopic lattices and observe bulk Chern numbers of 1 and 2, indicating that these structures support single and multimode edge elastic waves immune to backscattering. These robust one-way phononic waveguides could potentially lead to the design of a novel class of surface wave devices that are widely used in electronics, telecommunication, and acoustic imaging.

36 MATERIALS SCIENCE↗

Assessing operating characteristics of CAD algorithms in the absence of a gold standard

Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range of operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗