Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Experimental and FEM Study of Residual Stresses During Ultra-Precision Turning of Aluminum 2024-T3

Aluminum 2024-T3 is commonly used in ultra-precision turning. In this study, the residual stresses of aluminum 2024-T3 were investigated by the finite element method (FEM) and a series of cutting experiments. The effects of depth of cut, cutting speed, rake angle and tool edge radius on the residual stresses were discussed by FEM. Moreover, an orthogonal simulation experiment was also conducted. The order of the strong-to-weak sequence of factors on residual stresses in cutting direction is the rake angle, tool edge radius, depth of cut and cutting speed. The cutting experiments were conducted and the surface residual stresses in the cutting direction were measured by X-ray diffraction. The experimental results showed that increasing cutting speed and decreasing tool edge radius can reduce the surface residual stresses.

36 MATERIALS SCIENCE↗

Precise calculation of quasienergies of a driven two-level atom based on the Guo-Wu-Van Woerkom solution

The exact algebraic solution recently obtained by Guo, Wu, and Van Woerkom (Phys. Rev. A 73 (2006) 023419) made possible accurate calculations of quasienergies of a driven two-level atom with an arbitrary original energy spacing and laser intensity. Due to the complication of the analytic solutions that involves an infinite number of infinite determinants, many mathematical difficulties must be overcome to obtain precise values of quasienergies. In this paper, with a further developed algebraic method, we show how to solve the computational problem completely and results are presented in a data table. With this table, one can easily obtain all quasienergies of a driven two-level atom with an arbitrary original energy spacing and arbitrary intensity and frequency of the driving laser. The numerical solution technique developed here can be applied to the calculation of Freeman resonances in photoelectron energy spectra. As an example for applications, we show how to use the data table to calculate the peak laser intensity at which a Freeman resonance occurs in the transition between the ground Xe 5p P{sub 3/2} state and the Rydberg state Xe 8p P{sub 3/2}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local quantum uncertainty guarantees the measurement precision for two coupled two-level systems in non-Markovian environment

Quantum Fisher information (QFI) is an important feature for the precision of quantum parameter estimation based on the quantum Cramér–Rao inequality. When the quantum state satisfies the von Neumann–Landau equation, the local quantum uncertainty (LQU), as a kind of quantum correlation, present in a bipartite mixed state guarantees a lower bound on QFI in the optimal phase estimation protocol (Girolami et al., 2013). However, in the open quantum systems, there is not an explicit relation between LQU and QFI generally. In this paper, we study the relation between LQU and QFI in open systems which is composed of two interacting two-level systems coupled to independent non-Markovian environments with the entangled initial state embedded by a phase parameter θ. The analytical calculations show that the QFI does not depend on the phase parameter θ, and its decay can be restrained through enhancing the coupling strength or non-Markovianity. Meanwhile, the LQU is related to the phase parameter θ and shows plentiful phenomena. In particular, we find that the LQU can well bound the QFI when the coupling between the two systems is switched off or the initial state is Bell state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision measurement of relative γ-ray intensities from the decay of 61Cu

A discrepancy, well outside reported uncertainties, has been observed between the accepted and measured values of the intensity ratio of the two strongest γ-ray following 61 Cu β + decay. This discrepancy has significant impact since the nat Ni(d,x) 61 Cu reaction has historically been one of only a few IAEA recommendations for use as a deuteron flux monitor and a considerable number of published cross sections measured in ratio to that beam monitor cross section may depend on the choice of either the first or second strongest ray in those calculations. To determine the magnitude of this error most precisely, over a hundred separate measurements of the 283 keV to 656 keV γ-ray emission ratio were collected from seven experiments and a variety of detectors and detection geometries. A weighted average of all these measurements indicates an error in the value listed in the Nuclear Data Sheets of 11% in either the primary or second-highest intensity γ-ray of 61 Cu, potentially introducing an 11% error in 61 Cu production cross section measurements, cross sections using nickel activation as a deuteron beam current monitor, or in dose rates when 61 Cu is used in nuclear medicine. General agreement with the Data Sheets with ten other intensity ratios suggests the most probable error is in the secondary (656 keV) emission, which accordingly should be updated from 10.8% to 9.69%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of the cyanobacterial amino acid metabolism with a precise genome-scale metabolic reconstruction of Anabaena sp. UTEX 2576

Filamentous cyanobacteria such as Anabaena sp. UTEX 2576 (a.k.a., Nostoc sp. PCC 7120) are a sustainable platform for commodity and specialty chemical production. Anabaena is a model cyanobacterium adopted to study production of nitrogen-containing metabolites useful for chemical, cosmetic, and pharmaceutical industries. Therefore, a precise description of the Anabaena metabolic network is desired to analyze their amino-acid metabolism and elucidate potential applications of these cyanobacteria as host organisms for biotechnological production. Secondary metabolite production depends on the metabolic availability of amino acids. We provide new insight on the biotechnological utilization of Anabaena after predicting phycocyanobilin and amino-acid production rates, using a genome-scale metabolic model (iDN1004). This metabolic reconstruction is a highly comprehensive representation of the global metabolism of Anabaena, which also contains experimental biomass equations and constraints under photoautotrophic and photodiazotrophic growth. Modelling results ranked proteinogenic amino acids based on predicted metabolic fluxes through amino-acid producing reactions. From these, l-aspartate, glycine, l-serine, l-valine, l-alanine, l-threonine, and l-leucine were selected as the best branching points to conduct metabolic engineering, where l-aspartate, l-serine, l-valine and glycine serve as potential precursors of the secondary metabolites Schizokinen (a siderophore), Sphingosine (a ceramide), Lyngbyatoxin A (an alkaloid), and Shinorine (a sunscreen).

59 BASIC BIOLOGICAL SCIENCES↗

The catalytic behavior of precisely synthesized Pt–Pd bimetallic catalysts for use as diesel oxidation catalysts

The demands of stricter diesel engine emission regulations have created challenges for current exhaust systems. With advances in low-temperature internal combustion engines and their operations, advances must also be made in vehicle exhaust catalysts. Most current diesel oxidation catalysts use heavy amounts of precious group metals (PGMs) for hydrocarbon (HC), CO, and NO oxidation. These catalysts are expensive and are most often synthesized with poor bimetallic interaction and dispersion. In this paper, the goal was to study the effect of aging on diesel emission abatement of Pt–Pd bimetallic nanoparticles precisely prepared with different morphologies: well dispersed core–shell vs. well dispersed homogeneously alloyed vs. poorly dispersed, poorly alloyed particles. Alumina and silica supports were studied. Particle morphology and dispersion were analyzed before and after hydrothermal treatments by XRD, EDX, and STEM. Reactivity as a function of aging was measured in simulated diesel engine exhaust. While carefully controlled bimetallic catalyst nanoparticle structure has a profound influence on initial or low temperature catalytic activity, the differences in behavior disappear with higher temperature aging as thermodynamic equilibrium is achieved. The metallic character of Pt-rich alumina-supported catalysts is such that behavior rather closely follows the Pt–Pd metal phase diagram. Nanoparticles disparately composed as well-dispersed core–shell (via seq-SEA), well-dispersed homogeneously alloyed (via co-SEA), and poorly dispersed, poorly alloyed (via co-DI) end up as well alloyed, large particles of almost the same size and activity. With Pd-rich systems, the oxidation of Pd also figures into the equilibrium, such that Pd-rich oxide phases appear in the high temperature forms along with alloyed metal cores. Finally, the small differences in activity after high temperature aging can be attributed to the synthesis methods, sequential SEA and co-DI which give rise, after aging, to a bimetallic surface enriched in Pd.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision measurement of relative permittivity of aluminum oxide for a high power resonant waveguide window with low return loss

An iterative method of estimating permittivity and window thickness with high precision is developed for half wavelength resonant waveguide windows for use in a lower hybrid launcher for DIII-D. The high Q factor of half-wavelength windows results in extreme sensitivity of return loss on small deviations in permittivity. Permittivity and loss tangent measurements of Morgan AL-995 99.5% aluminum oxide ceramic using a waveguide resonant cavity per ASTM D2520-13 determine variation of permittivity with frequency. Measurement of window resonant frequency in conjunction with the slope of permittivity from waveguide cavity measurements determine required thickness of a resonant window within 5 MHz of the desired resonant frequency. Methods to improve measurement accuracy of resonant peaks on a vector network analyzer are discussed. A sensitivity study to dimensional variations in window or sample rod geometry, and shift in resonant frequency due to RF heating of the window material is conducted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision masses for studies of the astrophysical r process

Half of the elements heavier than iron (Z > 26) are thought to be created through the astrophysical r process, whereby nuclides are produced via a rapid series of nuclear reactions that are postulated to occur in high temperature and neutron density environments such as supernovae or merging neutron stars. The nucleosynthetic path that describes the sequence of reactions through the chart of nuclides strongly depends on the neutron-separation energies of the nuclei. Until recently, however, almost all of these neutron-rich nuclei were not within reach of accelerator facilities, and therefore simulations of the r process had to rely on mass models for input into the calculations. Now, with the advent of facilities such as CARIBU at Argonne National Laboratory, the masses of many nuclides along the r-process path can be determined precisely with Penning trap mass spectrometers coupled to these facilities. More than 70 nuclides have been measured with the Canadian Penning Trap mass spectrometer alone in the past year, which overlap and complement results from other Penning trap mass spectrometers, and first calculations with these new masses suggest the timescale of the r process through the tin isotopes is delayed much more strongly than mass models would suggest.

Clark, Jason↗

On-Line Use of Three-Dimensional Marker Trajectory Estimation From Cone-Beam Computed Tomography Projections for Precise Setup in Radiotherapy for Targets With Respiratory Motion

Purpose: To develop and evaluate accurate and objective on-line patient setup based on a novel semiautomatic technique in which three-dimensional marker trajectories were estimated from two-dimensional cone-beam computed tomography (CBCT) projections. Methods and Materials: Seven treatment courses of stereotactic body radiotherapy for liver tumors were delivered in 21 fractions in total to 6 patients by a linear accelerator. Each patient had two to three gold markers implanted close to the tumors. Before treatment, a CBCT scan with approximately 675 two-dimensional projections was acquired during a full gantry rotation. The marker positions were segmented in each projection. From this, the three-dimensional marker trajectories were estimated using a probability based method. The required couch shifts for patient setup were calculated from the mean marker positions along the trajectories. A motion phantom moving with known tumor trajectories was used to examine the accuracy of the method. Trajectory-based setup was retrospectively used off-line for the first five treatment courses (15 fractions) and on-line for the last two treatment courses (6 fractions). Automatic marker segmentation was compared with manual segmentation. The trajectory-based setup was compared with setup based on conventional CBCT guidance on the markers (first 15 fractions). Results: Phantom measurements showed that trajectory-based estimation of the mean marker position was accurate within 0.3 mm. The on-line trajectory-based patient setup was performed within approximately 5 minutes. The automatic marker segmentation agreed with manual segmentation within 0.36 {+-} 0.50 pixels (mean {+-} SD; pixel size, 0.26 mm in isocenter). The accuracy of conventional volumetric CBCT guidance was compromised by motion smearing ({<=}21 mm) that induced an absolute three-dimensional setup error of 1.6 {+-} 0.9 mm (maximum, 3.2) relative to trajectory-based setup. Conclusions: The first on-line clinical use of trajectory estimation from CBCT projections for precise setup in stereotactic body radiotherapy was demonstrated. Uncertainty in the conventional CBCT-based setup procedure was eliminated with the new method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision Hypofractionated Radiation Therapy in Poor Performing Patients With Non-Small Cell Lung Cancer: Phase 1 Dose Escalation Trial

Purpose: Treatment regimens for locally advanced non-small cell lung cancer (NSCLC) give suboptimal clinical outcomes. Technological advancements such as radiation therapy, the backbone of most treatment regimens, may enable more potent and effective therapies. The objective of this study was to escalate radiation therapy to a tumoricidal hypofractionated dose without exceeding the maximally tolerated dose (MTD) in patients with locally advanced NSCLC. Methods and Materials: Patients with stage II to IV or recurrent NSCLC and Eastern Cooperative Oncology Group performance status of 2 or greater and not candidates for surgical resection, stereotactic radiation, or concurrent chemoradiation were eligible. Highly conformal radiation therapy was given to treat intrathoracic disease in 15 fractions to a total of 50, 55, or 60 Gy. Results: Fifty-five patients were enrolled: 15 at the 50-Gy, 21 at the 55-Gy, and 19 at the 60-Gy dose levels. A 90-day follow-up was completed in each group without exceeding the MTD. With a median follow-up of 12.5 months, there were 93 grade ≥3 adverse events (AEs), including 39 deaths, although most AEs were considered related to factors other than radiation therapy. One patient from the 55- and 60-Gy dose groups developed grade ≥3 esophagitis, and 5, 4, and 4 patients in the respective dose groups experienced grade ≥3 dyspnea, but only 2 of these AEs were considered likely related to therapy. There was no association between fraction size and toxicity (P=.24). The median overall survival was 6 months with no significant differences between dose levels (P=.59). Conclusions: Precision hypofractionated radiation therapy consisting of 60 Gy in 15 fractions for locally advanced NSCLC is generally well tolerated. This treatment regimen could provide patients with poor performance status a potent alternative to chemoradiation. This study has implications for the cost effectiveness of lung cancer therapy. Additional studies of long-term safety and efficacy of this therapy are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Quest for Evidence for Proton Therapy: Model-Based Approach and Precision Medicine

Purpose: Reducing dose to normal tissues is the advantage of protons versus photons. We aimed to describe a method for translating this reduction into a clinically relevant benefit. Methods and Materials: Dutch scientific and health care governance bodies have recently issued landmark reports regarding generation of relevant evidence for new technologies in health care including proton therapy. An approach based on normal tissue complication probability (NTCP) models has been adopted to select patients who are most likely to experience fewer (serious) adverse events achievable by state-of-the-art proton treatment. Results: By analogy with biologically targeted therapies, the technology needs to be tested in enriched cohorts of patients exhibiting the decisive predictive marker: difference in normal tissue dosimetric signatures between proton and photon treatment plans. Expected clinical benefit is then estimated by virtue of multifactorial NTCP models. In this sense, high-tech radiation therapy falls under precision medicine. As a consequence, randomizing nonenriched populations between photons and protons is predictably inefficient and likely to produce confusing results. Conclusions: Validating NTCP models in appropriately composed cohorts treated with protons should be the primary research agenda leading to urgently needed evidence for proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1/2 Study of the Addition of Cisplatin to Adjuvant Chemotherapy With Image Guided High-Precision Radiation Therapy for Completely Resected Gastric Cancer

Purpose: Locoregional recurrence is common after surgery for gastric cancer. Adjuvant therapy improves outcomes but with toxicity. This phase 1/2 study investigated infusional 5-fluorouracil (5-FU) in combination with biweekly cisplatin delivered concurrently with image guided high-precision radiation therapy. Methods and Materials: Eligible patients had completely resected stage IB to IV (Union for International Cancer Control TNM 6th edition) nonmetastatic gastric adenocarcinoma. Treatment constituted 12 weeks of infusional 5-FU (200 mg/m{sup 2}/day) with cisplatin added in a standard 3 + 3 dose escalation protocol (0, 20, 30, and 40 mg/m{sup 2}) during weeks 1, 3, 5, and 7, and an additional week 9 dose in the final cohort. Radiation therapy (45 Gy in 25 fractions) was delivered during weeks 3 to 7. Maximum tolerated dose (MTD) was determined in phase 1 and confirmed in phase 2. Results: Among the 55 patients (median age, 54 years; range 28-77 years; 55% male), the median follow-up time was 3.0 years (range, 0.3-5.3 years). Five patients in phase 1 experienced dose-limiting toxicity, and MTD was determined as 4 cycles of 40 mg/m{sup 2} cisplatin. Twenty-seven patients were treated at MTD. Acute grade 3 to 4 toxicity rate was 37.0% at MTD and 29.1% across all dose levels. No treatment-related deaths occurred. Fourteen patients experienced recurrent disease. The 2-year overall survival (OS) and relapse-free survival were 85% and 74%, respectively. Median OS has not been reached. Quality of life (QOL) was impaired during treatment, but most scores recovered by 4 weeks. Conclusion: Cisplatin can be safely delivered with 5-FU–based chemoradiation therapy. Acute toxicity was acceptable, and patient-reported QOL showed the regimen was tolerable. Outcomes are encouraging and justify further study of this regimen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Personalising Prostate Radiotherapy in the Era of Precision Medicine: A Review

Prostate cancer continues to be the most commonly diagnosed cancer among Canadian men. The introduction of routine screening and advanced treatment options have allowed for a decrease in prostate cancer-related mortality, but outcomes following treatment continue to vary widely. In addition, the overtreatment of indolent prostate cancers causes unnecessary treatment toxicities and burdens health care systems. Accurate identification of patients who should undergo aggressive treatment, and those which should be managed more conservatively, needs to be implemented. More tumour and patient information is needed to stratify patients into low-, intermediate-, and high-risk groups to guide treatment options. This paper reviews the current literature on personalised prostate cancer management, including targeting tumour hypoxia, genomic and radiomic prognosticators, and radiobiological tumour targeting. A review of the current applications and future directions for the use of big data in radiation therapy is also presented. Prostate cancer management has a lot to gain from the implementation of personalised medicine into practice. Using specific tumour and patient characteristics to personalise prostate radiotherapy in the era of precision medicine will improve survival, decrease unnecessary toxicities, and minimise the heterogeneity of outcomes following treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision current regulator for NMR electromagnets

When using electromagnets or non-persistent superconducting magnets, the field stability can be directly proportional to the current stability. We present in this report a simple design for a current regulator based upon a high-precision, dc-dc fluxgate transformer. The output current and NMR frequency are stabilized by about a factor of 50, over times of order one hour. The method can be applied to essentially any current supply.

59 BASIC BIOLOGICAL SCIENCES↗

Classification and regression models of audio and vibration signals for machine state monitoring in precision machining systems

Here we present a data-driven method for monitoring machine status in manufacturing processes. Audio and vibration data from precision machining are used for inference in two operating scenarios: (a) variable machine health states (anomaly detection); and (b) settings of machine operation (state estimation). Audio and vibration signals are first processed through Fast Fourier Transform and Principal Component Analysis to extract transformed and informative features. These features are then used in the training of classification and regression models for machine state monitoring. Specifically, three classifiers (K-nearest neighbors, convolutional neural networks and support vector machines) and two regressors (support vector regression and neural network regression) were explored, in terms of their accuracy in machine state prediction. It is shown that the audio and vibration signals are sufficiently rich in information about the machine that 100% state classification accuracy could be accomplished. Data fusion was also explored, showing overall superior accuracy of data-driven regression models.

42 ENGINEERING↗

Robust natural nanocomposites realizing unprecedented ultrafast precise molecular separations

Synthetic polymer membranes can potentially reduce the large energy and carbon footprints that are typically associated with traditional chemical separation technologies. Unfortunately, current production protocols negate the green benefits of membrane separation. To address this bottleneck, here we report the use of natural materials monosaccharide – glucose and polydopamine and Zr-based metal organic frameworks (MOFs) to fabricate ultrathin nanocomposite membranes via interfacial polymerization reaction. The synergistic effect of these three materials on angstrom-scale molecular transport both in organic solvent and aqueous environment was elucidated using a series of complementary techniques. We demonstrate such nature-inspired nanocomposite membranes enable structural stability even in polar aprotic solvents, and unparalleled ultra-fast, low-pressure, precise separations in both nanofiltration modes, which easily surpass state-of-the-art membranes relying on unsustainable materials. Finally, the multi-functionality of saccharide nanocomposites was elegantly harnessed to impact separation applications that contribute towards a better living environment.

36 MATERIALS SCIENCE↗

Precision measurement of 65 Zn electron-capture decays with the KDK coincidence setup

65 Zn is a common calibration source, moreover used as a radioactive tracer in medical and biological studies. In many cases, γ-spectroscopy is a preferred method of 65 Zn standardization, which relies directly on the branching ratio of Jπ( 65 Zn) = 5/2- → Jπ( 65 Cu) = 5/2 - via electron capture (EC*). We measure the relative intensity of this branch to that proceeding directly to the ground state (EC 0 ) using a novel coincidence technique, finding I EC 0/IEC* = 0.9684 ± 0.0018. Re-evaluating the decay scheme of 65 Zn by adopting the commonly evaluated branching ratio of I β+ = 1.4271(7)% we obtain IEC* = (50.08 ± 0.06)%, and I EC 0 = (48.50 ± 0.06)%. The associated 1115 keV gamma intensity agrees with the previously reported NNDC value, and is now accessible with a factor of ~2 increase in precision. Our re-evaluation removes reliance on the deduction of this gamma intensity from numerous measurements, some of which disagree and depend directly on total activity determination. The KDK experimental technique provides a new avenue for verification or updates to the decay scheme of 65 Zn, and is applicable to other isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AdjointBackMapV2: Precise reconstruction of arbitrary CNN unit’s activation via adjoint operators

Adjoint operators have been found to be effective in the exploration of CNN’s inner workings (Wan and Choe, 2022). However, the previous no-bias assumption restricted its generalization. We overcome the restriction via embedding input images into an extended normed space that includes bias in all CNN layers as part of the extended space and propose an adjoint-operator-based algorithm that maps high-level weights back to the extended input space for reconstructing an effective hypersurface. Such hypersurface can be computed for an arbitrary unit in the CNN, and here we prove that this reconstructed hypersurface, when multiplied by the original input (through an inner product), will precisely replicate the output value of each unit. We show experimental results based on the CIFAR-10 and CIFAR-100 data sets where the proposed approach achieves near 0 activation value reconstruction error.

97 MATHEMATICS AND COMPUTING↗