Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

SU-F-E-19: A Novel Method for TrueBeam Jaw Calibration

Purpose: A simple jaw calibration method is proposed for Varian TrueBeam using an EPID-Encoder combination that gives accurate fields sizes and a homogeneous junction dose. This benefits clinical applications such as mono-isocentric half-beam block breast cancer or head and neck cancer treatment with junction/field matching. Methods: We use EPID imager with pixel size 0.392 mm × 0.392 mm to determine the radiation jaw position as measured from radio-opaque markers aligned with the crosshair. We acquire two images with different symmetric field sizes and record each individual jaw encoder values. A linear relationship between each jaw’s position and its encoder value is established, from which we predict the encoder values that produce the jaw positions required by TrueBeam’s calibration procedure. During TrueBeam’s jaw calibration procedure, we move the jaw with the pendant to set the jaw into position using the predicted encoder value. The overall accuracy is under 0.1 mm. Results: Our in-house software analyses images and provides sub-pixel accuracy to determine field centre and radiation edges (50% dose of the profile). We verified the TrueBeam encoder provides a reliable linear relationship for each individual jaw position (R{sup 2}>0.9999) from which the encoder values necessary to set jaw calibration points (1 cm and 19 cm) are predicted. Junction matching dose inhomogeneities were improved from >±20% to <±6% using this new calibration protocol. However, one technical challenge exists for junction matching, if the collimator walkout is large. Conclusion: Our new TrueBeam jaw calibration method can systematically calibrate the jaws to crosshair within sub-pixel accuracy and provides both good junction doses and field sizes. This method does not compensate for a larger collimator walkout, but can be used as the underlying foundation for addressing the walkout issue.

60 APPLIED LIFE SCIENCES↗

SU-F-I-08: CT Image Ring Artifact Reduction Based On Prior Image

Purpose: In computed tomography (CT) system, CT images with ring artifacts will be reconstructed when some adjacent bins of detector don’t work. The ring artifacts severely degrade CT image quality. We present a useful CT ring artifacts reduction based on projection data correction, aiming at estimating the missing data of projection data accurately, thus removing the ring artifacts of CT images. Methods: The method consists of ten steps: 1) Identification of abnormal pixel line in projection sinogram; 2) Linear interpolation within the pixel line of projection sinogram; 3) FBP reconstruction using interpolated projection data; 4) Filtering FBP image using mean filter; 5) Forwarding projection of filtered FBP image; 6) Subtraction forwarded projection from original projection; 7) Linear interpolation of abnormal pixel line area in the subtraction projection; 8) Adding the interpolated subtraction projection on the forwarded projection; 9) FBP reconstruction using corrected projection data; 10) Return to step 4 until the pre-set iteration number is reached. The method is validated on simulated and real data to restore missing projection data and reconstruct ring artifact-free CT images. Results: We have studied impact of amount of dead bins of CT detector on the accuracy of missing data estimation in projection sinogram. For the simulated case with a resolution of 256 by 256 Shepp-Logan phantom, three iterations are sufficient to restore projection data and reconstruct ring artifact-free images when the dead bins rating is under 30%. The dead-bin-induced artifacts are substantially reduced. More iteration number is needed to reconstruct satisfactory images while the rating of dead bins increases. Similar results were found for a real head phantom case. Conclusion: A practical CT image ring artifact correction scheme based on projection data is developed. This method can produce ring artifact-free CT images feasibly and effectively.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-07: An Innovative Fiducial-Less Tracking Method for Radiation Treatment of Abdominal Tumors by Diaphragm Disparity Analysis

Purpose: To investigate the feasibility of tracking abdominal tumors without the use of gold fiducial markers Methods: In this simulation study, an abdominal 4DCT dataset, acquired previously and containing 8 phases of the breathing cycle, was used as the testing data. Two sets of DRR images (45 and 135 degrees) were generated for each phase. Three anatomical points along the lung-diaphragm interface on each of the Digital Reconstructed Radiograph(DRR) images were identified by cross-correlation. The gallbladder, which simulates the tumor, was contoured for each phase of the breathing cycle and the corresponding centroid values serve as the measured center of the tumor. A linear model was created to correlate the diaphragm’s disparity of the three identified anatomical points with the center of the tumor. To verify the established linear model, we sequentially removed one phase of the data (i.e., 3 anatomical points and the corresponding tumor center) and created new linear models with the remaining 7 phases. Then we substituted the eliminated phase data (disparities of the 3 anatomical points) into the corresponding model to compare model-generated tumor center and the measured tumor center. Results: The maximum difference between the modeled and the measured centroid values across the 8 phases were 0.72, 0.29 and 0.30 pixels in the x, y and z directions respectively, which yielded a maximum mean-squared-error value of 0.75 pixels. The outcomes of the verification process, by eliminating each phase, produced mean-squared-errors ranging from 0.41 to 1.28 pixels. Conclusion: Gold fiducial markers, requiring surgical procedures to be implanted, are conventionally used in radiation therapy. The present work shows the feasibility of a fiducial-less tracking method for localizing abdominal tumors. Through developed diaphragm disparity analysis, the established linear model was verified with clinically accepted errors. The tracking method in real time under different radiation therapy platforms will be further investigated.

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-09: Optimization of the Design of a Moving Blocker for Cone-Beam CT Scatter Correction: Experimental Evaluation

Purpose: A moving blocker based strategy has shown promising results for scatter correction in cone-beam computed tomography (CBCT). Different geometry designs and moving speeds of the blocker affect its performance in image reconstruction accuracy. The goal of this work is to optimize the geometric design and moving speed of the moving blocker system through experimental evaluations. Methods: An Elekta Synergy XVI system and an anthropomorphic pelvis phantom CIRS 801-P were used for our experiment. A blocker consisting of lead strips was inserted between the x-ray source and the phantom moving back and forth along rotation axis to measure the scatter signal. Accoriding to our Monte Carlo simulation results, three blockers were used, which have the same lead strip width 3.2mm and different gap between neighboring lead strips, 3.2, 6.4 and 9.6mm. For each blocker, three moving speeds were evaluated, 10, 20 and 30 pixels per projection (on the detector plane). Scatter signal in the unblocked region was estimated by cubic B-spline based interpolation from the blocked region. CBCT image was reconstructed by a total variation (TV) based algebraic iterative reconstruction (ART) algorithm from the partially blocked projection data. Reconstruction accuracy in each condition is quantified as CT number error of region of interest (ROI) by comparing to a CBCT reconstructed image from analytically simulated unblocked and scatter free projection data. Results: Highest reconstruction accuracy is achieved when the blocker width is 3.2 mm, the gap between neighboring lead strips is 9.6 mm and the moving speed is 20 pixels per projection. RMSE of the CT number of ROIs can be reduced from 436 to 27. Conclusions: Image reconstruction accuracy is greatly affected by the geometry design of the blocker. The moving speed does not have a very strong effect on reconstruction result if it is over 20 pixels per projection.

60 APPLIED LIFE SCIENCES↗

WE-FG-BRA-08: Potential Role of the Glycolytic Oscillator in Acute Hypoxia in Tumors

Purpose: Oscillatory dynamics in acute hypoxia have been observed, but poorly understood. They have mostly been attributed to vascular perturbations, but no link has yet been made to metabolic causes. We set out to determine the fundamental frequencies and test for coherence in tumor oxygen dynamics and spatial properties. Methods: Severe combined immunodeficient (SCID) mice were inoculated onto bilateral flanks with human derived head and neck carcinoma (UW-SCC22) cell line xenografts. Oxygen dynamics were monitored in the tumor every minute for an hour using three modalities: blood oxygen level dependent - magnetic resonance imaging (BOLD-MRI), hemoglobin oxygen saturation photoacoustic, and locally manufactured optical probes for spectral fitting. A statistical test was used to separate fluctuating from non-fluctuating voxels and pixels in BOLD-MRI and photoacoustic data respectively. The power spectrum density (PSD) and the autocorrelation functions were calculated for the time series of each voxel, pixel and region, of the BOLD-MRI, photoacoustic or fiber optic data respectively. Results: Using all three techniques, intermittent oxygen dynamics with both coherent and incoherent signatures was observed in the tumors. Upon averaging the PSDs of fluctuating voxels and pixels, it was found that these oscillations occurred with periods of minutes to tens of minutes from all three approaches. Observations from the BOLD-MRI and photoacoustic data showed that clusters of voxels oscillated in a synchronized manner. Conclusion: We were able to use three different modalities to show that fluctuation in tumor oxygen is both coherent and incoherent, with periods of minutes to tens of minutes. These periods are very similar to those from the well-established metabolic, non-linear biomechanical phenomenon called the glycolytic oscillator. This may provide an additional explanation to the cause of cyclic hypoxia. Such dynamics could have profound implications in hypofractionated radiotherapy regiments and could help guide treatment and make it more patient specific. The authors would like to thank the University of Wisconsin Carbone Cancer Center (UWCCC) for the funds to complete this project. This work is also supported in part by NIH/NCI P30 CA014520- UW Comprehensive Cancer Center Support”.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-04: Noise Suppression for Energy-Resolved CT Via Variance Weighted Non-Local Filtration

Purpose: The photon starvation problem is exacerbated in energy-resolved CT, since the detected photons are shared by multiple energy channels. Using pixel similarity-based non-local filtration, we aim to produce accurate and high-resolution energy-resolved CT images with significantly reduced noise. Methods: Averaging CT images reconstructed from different energy channels reduces noise at the price of losing spectral information, while conventional denoising techniques inevitably degrade image resolution. Inspired by the fact that CT images of the same object at different energies share the same structures, we aim to reduce noise of energy-resolved CT by averaging only pixels of similar materials - a non-local filtration technique. For each CT image, an empirical exponential model is used to calculate the material similarity between two pixels based on their CT values and the similarity values are organized in a matrix form. A final similarity matrix is generated by averaging these similarity matrices, with weights inversely proportional to the estimated total noise variance in the sinogram of different energy channels. Noise suppression is achieved for each energy channel via multiplying the image vector by the similarity matrix. Results: Multiple scans on a tabletop CT system are used to simulate 6-channel energy-resolved CT, with energies ranging from 75 to 125 kVp. On a low-dose acquisition at 15 mA of the Catphan©600 phantom, our method achieves the same image spatial resolution as a high-dose scan at 80 mA with a noise standard deviation (STD) lower by a factor of >2. Compared with another non-local noise suppression algorithm (ndiNLM), the proposed algorithms obtains images with substantially improved resolution at the same level of noise reduction. Conclusion: We propose a noise-suppression method for energy-resolved CT. Our method takes full advantage of the additional structural information provided by energy-resolved CT and preserves image values at each energy level. Research reported in this publication was supported by the National Institute Of Biomedical Imaging And Bioengineering of the National Institutes of Health under Award Number R21EB019597. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

Femtojoule optical nonlinearity for deep learning with incoherent illumination

Optical neural networks (ONNs) are a promising computational alternative for deep learning due to their inherent massive parallelism for linear operations. However, the development of energy-efficient and highly parallel optical nonlinearities, a critical component in ONNs, remains an outstanding challenge. Here, we introduce a nonlinear optical microdevice array (NOMA) compatible with incoherent illumination by integrating the liquid crystal cell with silicon photodiodes at the single-pixel level. We fabricate NOMA with more than half a million pixels, each functioning as an optical analog of the rectified linear unit at ultralow switching energy down to 100 femtojoules per pixel. With NOMA, we demonstrate an optical multilayer neural network. Our work holds promise for large-scale and low-power deep ONNs, computer vision, and real-time optical image processing.

36 MATERIALS SCIENCE↗

Design optimization of MAPS-based detectors using a data-driven fast simulation approach

A parametric simulation tool for pixel sensors is presented. A realistic pixel response is simulated purely based on measurement input, without requiring detailed knowledge of the underlying manufacturing process. As such, it provides an efficient alternative to the use of Technology Computer-Aided Design simulations, which typically depend on proprietary process information. Due to its parametric approach, the package is fast and thus particularly useful for larger detector systems and high hit rate environments. This work presents measurements, simulation and its validation for the MALTA2 sensor. It is a small collection electrode monolithic active pixel sensor produced in the Tower 180 nm complementary metal-oxide-semiconductor imaging process. Modifications to the sensor’s periphery, mainly in the hit merger, are studied in order to optimize the performance for tracking and calorimetry. This optimization is of special interest as part of the MALTA3 sensor redesign in the 65 nm Tower Partners Semiconductor Co. process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scaling Resolution of Gigapixel Whole Slide Images Using Spatial Decomposition on Convolutional Neural Networks

Gigapixel images are prevalent in scientific domains ranging from remote sensing, and satellite imagery to microscopy, etc. However, training a deep learning model at the natural resolution of those images has been a challenge in terms of both, overcoming the resource limit (e.g. HBM memory constraints), as well as scaling up to a large number of GPUs. In this paper, we trained Residual neural Networks (ResNet) on 22,528 x 22,528-pixel size images using a distributed spatial decomposition method on 2,304 GPUs on the Summit Supercomputer. We applied our method on a Whole Slide Imaging (WSI) dataset from The Cancer Genome Atlas (TCGA) database. WSI images can be in the size of 100,000 x 100,000 pixels or even larger, and in this work we studied the effect of image resolution on a classification task, while achieving state-of-the-art AUC scores. Moreover, our approach doesn't need pixel-level labels, since we're avoiding patching from the WSI images completely, while adding the capability of training arbitrary large-size images. This is achieved through a distributed spatial decomposition method, by leveraging the non-block fat-tree interconnect network of the Summit architecture, which enabled GPU-to-GPU direct communication. Finally, detailed performance analysis results are shown, as well as a comparison with a data-parallel approach when possible.

Tsaris, Aristeidis (aris)↗

Research on a Pulmonary Nodule Segmentation Method Combining Fast Self-Adaptive FCM and Classification

The key problem of computer-aided diagnosis (CAD) of lung cancer is to segment pathologically changed tissues fast and accurately. As pulmonary nodules are potential manifestation of lung cancer, we propose a fast and self-adaptive pulmonary nodules segmentation method based on a combination of FCM clustering and classification learning. The enhanced spatial function considers contributions to fuzzy membership from both the grayscale similarity between central pixels and single neighboring pixels and the spatial similarity between central pixels and neighborhood and improves effectively the convergence rate and self-adaptivity of the algorithm. Experimental results show that the proposed method can achieve more accurate segmentation of vascular adhesion, pleural adhesion, and ground glass opacity (GGO) pulmonary nodules than other typical algorithms.

59 BASIC BIOLOGICAL SCIENCES↗

Plant density and enhanced plant vigor estimation for high-resolution images v1

The package contains algorithms for the estimation of sprout/plant density and the corresponding enhanced plant vigor from remotely sensed (RS) images. These algorithms aim to improve the plant characterization and monitoring in the early season when the soil component is significant compared to the plant spatial coverage. In such a scenario, the identification of sprouts (or plants) and the estimation of plant vegetation indexes can be performed only using UAV-acquired images. Additionally, because of the extremely high resolution, gridding becomes necessary to improve visualization and provide more informative maps. However, to capture the real range of values of the VIs, it is important to avoid the inclusion of those pixels belonging to the soil component. The sprout/plant density estimation algorithm takes in input a classification map and uses the vegetation class to estimates the plant density within a user-defined grid using a floating window. Similarly, the enhanced plant vigor algorithm takes in input the vegetation index and the classification map. The enhanced vegetation index is computed for each pixel as the average value among those pixels that belong to the vegetation class within a floating window. The software is developed for the MATLAB environment.

Falco, Nicola↗

hdsullivan/ResSR

This is the official implementation of ResSR [1]. ResSR is a computationally efficient MSI-SR method that achieves high-quality reconstructions by using a closed-form spectral decomposition along with a spatial residual correction. ResSR applies singular value decomposition to identify correlations across spectral bands, uses pixel-wise computation to upsample the MSI, and then applies a residual correction process to correct the high-spatial frequency components of the upsampled bands. While ResSR is formulated as the solution to a spatially-coupled optimization problem, we use pixel-wise regularization and derive an approximate closed-form solution, resulting in a pixel-wise algorithm with a dramatic reduction in computation that achieves state-of-the-art reconstructions. [1] Duba-Sullivan, H., Reid, E. J., Voisin, S., Bouman, C. A., & Buzzard, G. T. (2024). ResSR: A Computationally Efficient Residual Approach to Super-Resolving Multispectral Images. arXiv preprint arXiv:2408.13225.

Duba-Sullivan, Haley [Oak Ridge National Laborator↗

Photon noise correlations in millimeter-wave telescopes

Many modern millimeter and submillimeter (“mm-wave”) telescopes for astronomy are deploying more detectors by increasing the detector pixel density and, with the rise of lithographed detector architectures and high-throughput readout techniques, it is becoming increasingly practical to overfill the focal plane. However, when the pixel pitch p pix is small compared to the product of the wavelength λ and the focal ratio F , or p pix ≲1.2 F λ , the Bose term of the photon noise correlates between neighboring detector pixels due to the Hanbury Brown and Twiss (HBT) effect. When this HBT effect is non-negligible, the array-averaged sensitivity scales with the detector count N det less favorably than the uncorrelated limit of N det −1/2 . In this paper, we present a general prescription to calculate this HBT correlation based on a quantum optics formalism and extend it to polarization-sensitive detectors. We then estimate the impact of HBT correlations on the sensitivity of a model mm-wave telescope and discuss the implications for a focal plane design.

Hill, Charles A. (ORCID:0000000226416878)↗

Pan-arctic river bank erosion and accretion, and planform metrics measured over intervals ranging from 1973 to 2016

This dataset provides the tabular summary of analysis of 17 reaches of 15 Arctic rivers for river bank erosion and accretion rates, as well as, river channel properties such as channel width, bank curvature, and the aspect/orientation of the river banks. These rivers include the: Chandalar River, Alaska, Colville River, Alaska; Indigirka River, Russia; Kolyma River, Russia; Koyukuk River, Alaska; Lena River, Alaska; Noatak River, Alaska; Ob River, Russia; Pechora River, Russia; Tanana River, Alaska, Selawik River, Alaska; Taz River, Russia; Yana River, Russia; Yenisei River, Russia; and the Yukon River, Alaska. The dataset was generated from a total of 129 images including: Landsat, higher resolution satellite imagery, and aerial photography over time periods ranging from the 1970s and 2016. A full list of the image dates, row and path (for Landsat), and pixel resolutions is provided in the dataset. Masks for the Chandalar River, Tanana River, and Yukon at Holy Cross were obtained from Brown et al. (2020). The masks were analyzed using the Spatially Continuous Riverbank Erosion and Accretion Measurements (SCREAM) software detailed in Rowland et al. 2016. The masks used in this analysis can be found an accompanying dataset (doi:10.15485/1571527).In files with “summary” in the name, the data is provided at a pixel level, where each mapped bank pixel has an associated erosion or accretion value, a channel width, a curvature value, and an aspect each river and time period will have an individual file. Files with “Segments” in name provide data that is averaged along segments of the rivers. These data are consolidated into a single file each for the erosion and accretion measurements. These segments are approximately 10 channel widths in length. In addition to erosion and accretion rates, the segment-based results include area measurements of erosion and accretion, islands, and channels. Revisions 2023:-Data added for the Koyukuk River for time periods of 1978-2012, 1978-2018, and 2012-2018. ---Data added from the Chandalar River, Tanana River, and Yukon River at Holy Cross based on masks obtained from Brown et al. (2020).-Updated the values for Drainage area and river slope, see methods below-Added values for meant topographic slope for upstream contributing area, long term averaged annual maximum monthly flow, average annual maximum monthly flow for the time period of erosion record, and added the river slope extracted from the Lin et al. (2020) data product.-Add field for River Planform Multi threaded (M) or Single threaded-Added ‘ConsolidatedErosionSegments.csv’ which provides the same data as AllRiversErosionSegments.csv rebinned with averages along river segments based on upstream drainage area instead of channel segments based on lengths set to approximately 10 channel widths.

54 ENVIRONMENTAL SCIENCES↗

Aspen ploidy level and cover maps from NEON Airborne Observation Platform, 2018, Crested Butte, Colorado

Maps of aspen ploidy (diploid or triploid) developed using National Ecological Observatory Network (NEON) Airborne Observation Platform visible to shortwave infrared imaging spectroscopy data that were acquired over the Upper East River, Colorado in 2018. Maps of aspen distribution, as well as other land cover types that were used to screen for aspen dominated pixels are also provided. Each image file is provided as a GeoTiff with internal tiling and LZW compression. For use of ploidy maps, it is necessary to mask out non-aspen and shaded pixels. Shaded pixels are provided in an associated data package. For full details, please see associated publication and methods description. This dataset is associated with the publication in Ecological Applications.

54 ENVIRONMENTAL SCIENCES↗

Deployment of ADTimePix3 areaDetector Driver at Neutron and X-ray User Facilities

TimePix3 is a 65k hybrid pixel readout chip with simultaneous Time-of-Arrival (ToA) and Time-over-Threshold (ToT) recording in each pixel*. The chip operates without a trigger signal with a sparse readout where only pixels containing events are read out. The flexible architecture allows 40 MHits/s/cm² readout throughput, using simultaneous readout and acquisition by sharing readout logic with transport logic of superpixel matrix formed using 2x4 structure. The chip ToA records 1.5625 ns time resolution. The X-ray and charged particle events are counted directly. However, indirect neutron counts use 6Li fission in a scintillator matrix, such as ZnS(Ag). The fission space-charge region is limited to 5-9 um. A photon from scintillator material excites a photocathode electron, which is further multiplied in dual-stack MCP. The neutron count event is a cluster of electron events at the chip. We report on the EPICS areaDetector** ADTimePix3 driver that controls Serval*** using json commands. The driver directs data to storage and to a real-time processing pipeline and configures the chip. The time-stamped data are stored in raw .tpx3 file format and passed through a socket where the clustering software identifies individual neutron events. The conventional 2D images are available as images for each exposure frame, and a preview is useful for sample alignment. The areaDetector driver allows integration of time-enhanced capabilities of this detector into SNS beamlines controls and unprecedented time resolution.

Gofron, Kaz↗

3D, Flash, Induced Current Readout for Silicon Sensors

A new method for silicon microstrip and pixel detector readout using (1) 65 nm-technology current amplifers which can, for the first time with silicon microstrop and pixel detectors, have response times far shorter than the charge collection time (2) 3D trench electrodes large enough to subtend a reasonable solid angle at most track locations and so have adequate sensitivity over a substantial volume of pixel, (3) induced signals in addition to, or in place of, collected charge

47 OTHER INSTRUMENTATION↗

Focal Plane Array Low Background Testing (Focal Plane Array Characterization under a Low Background)

Most infra-red (IR) imagers for tactical applications use a direct injection (DI) input amplifier design. Fewer transistors in the unit cell allow the read-out electronic circuit (ROIC) to be minimized. This allows either more room for charge integration capacitors or finer pixel pitches. These ROICs work well at high background irradiance levels. However, at low background irradiance levels photocurrent inject efficiency for a DI unit cell amplifier is reduced. Some models have shown that this efficiency can drastically affect performance under low background conditions. The main benefit for Sandia National Laboratories (SNL) and L-3 Communications Cincinnati Electronics (L-3) was a better understanding of these types of sensors under low background conditions. It also provided the opportunity for an independent analysis of these sensors. The purpose of this project was to measure DI for low light levels under different operating temperatures of the L-3 CE103 a 1280 x 1024 indium antimonide 15 micron pitch detector. Results showed DI efficiency approaches 75% under extremely low light levels. Additionally, measured data didn't conform well to traditional circuit based models indicated that other effects are contributing to DI efficiency. A "spot scanning" PSF measurement was also conducted to measure pixel-to-pixel crosstalk for this array. Spot scanning data showed near ideal performance.

47 OTHER INSTRUMENTATION↗