Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Online Static Load Model Estimation in Distribution Systems

This paper focuses on parameter identification for time-varying voltage-dependent polynomial load models in distribution systems—namely, the constant impedance (Z), constant current (I), and constant power (P). The paper assumes the presence of measurements at the distribution nodes from various sources, each at varying temporal resolutions. The least- squares estimation method with bounded variables is used to convert the measurements into ZIP parameter estimations for loads at various locations on the feeder. The results and discussions focus on some of the estimation issues faced in a distribution system caused by varying voltage sensitivities of loads along a feeder, measurement resolution, impact of window size and sampling rate of measurement data. Finally, the paper uses dynamic simulations data (synthetic high-resolution measurements) to further improve the estimation results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of WEC Design Loads: A Comparison of Numerical and Experimental Approaches: Preprint

The development of accurate design loads is a critical part of the design of a wave energy converter (WEC). In this paper, we evaluate the impact of different approaches to determining extreme wave loading on the Triton WEC using a combination of mid-fidelity and high-fidelity numerical modeling tools, complemented by scaled physical model tests. The mid-fidelity approach used is a time-domain model based on linearized potential flow hydrodynamics while the high-fidelity modeling tool is an unsteady RANS CFD model. A 1:30 scale physical model of the Triton WEC was tested at the Oregon State University Large Wave Flume. A comparison will be presented between the design loads predicted by the mid-fidelity model, the CFD model, and the physical model tests, and suggestions for best practices will be offered.

16 TIDAL AND WAVE POWER↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings: Preprint

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of High Levels of Distributed PV and Load Dynamics on Bulk Power Transient Stability: Preprint

The addition of large amounts of wind and solar generation to bulk power systems that are traditionally subject to operating constraints set by transient stability and frequency response limitations is the subject of considerable concern in the industry in all North American grids. The U.S. Western Interconnection is expected to experience substantial additional growth in both wind and solar generation. This generation will, to some extent, displace large central station thermal generation, both coal and gas-fired, which have traditionally helped maintain stability. A substantial fraction of the new photovoltaic (PV) solar generation will be deeply embedded in the distribution system and will be electrically in close proximity to customer loads. Several aspects of this renewable generation on transient stability and frequency response have been investigated and reported elsewhere in summaries of a study that included an investigation of the dynamic performance of the Western Interconnection with high penetrations of wind and solar generation. In this paper, modeling and the impact of distributed PV generation and dynamic loads are reported. The key finding is that the transient performance, particularly the fault ride-through behavior of embedded PV, is critical to system stability. Poor ride-through characteristics on distributed generation are shown in the study to collapse the entire grid. The dynamic behavior of the loads, aside from the embedded PV is also shown to be a critical element. The investigation reinforces the need for valid models and for thorough system planning studies.

14 SOLAR ENERGY↗

Restoring Critical Loads in Resilient Distribution Systems Using a Curriculum Learned Controller: Preprint

In this paper, we propose a curriculum learned reinforcement learning (RL) controller to facilitate distribution system critical load restoration (CLR), leveraging RL's fast online response and its outstanding optimal sequential control capability. Like many grid control problems, CLR is complicated due to the large control action space and renewable uncertainty in a heavily constrained non-linear environment with strong intertemporal dependency. The nature of the problem oftentimes causes the RL policy to converge to a poor-performing local optimum if learned directly. To overcome this, we design a two-stage curriculum in which the RL agent will learn generation control and load restoration decision under different scenarios progressively. Via curriculum learning, the trained RL controller is expected to achieve a better control performance, with critical loads restored as rapidly and reliably as possible. Using the IEEE 13-bus test system, we illustrate the performance of the RL controller trained by the proposed curriculum-based method.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy: Preprint

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Integrated High-performance Computing and Digital Real-time Simulation Testbed to Benchmark Closed-loop Load Shedding Algorithms in Power Systems

An integrated testbed using digital real-time simulator (DRTS) and a high-performance computing (HPC) cluster is presented here to compare speed and performance of computational schemes to mitigate time-critical issues in electric power systems. The first approach in this testbed validation is taken by running a set of closed-loop load shedding algorithms to compare and contrast two paradigms of arresting cascading failure propagation. Two algorithms involve solving DC and AC power flow model-based optimization problems to compute load shedding at different buses, while a model-based stochastic search using parallel computing provides a viable alternative. The algorithms are implemented in the DRTS-HPC testbed for the IEEE 14-bus benchmark transmission system. As a proof of the concept, simulation results are presented for implementation of closed-loop load-shedding algorithms for cascading failures in the DRTS-HPC testbed

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Individual Blade Pitch Control of an Ocean Current Turbine for Load Reduction

A Direct Adaptive Disturbance Rejection (DADR) control algorithm is evaluated using a numer-ical simulation of an Ocean Current Turbine (OCT) for its ability to minimize the cyclic loadings on the rotor blades caused by current shear. This control algorithm reduces these cyclic loadings by individually altering the pitch angles of the rotor blades as a function of rotor rotation angle. The OCT numerical model represents a system with a single 3 bladed 20 meter diameter rotor operated in the Gulf Stream off the coast of Ft. Lauderdale, Florida for mean and maximum measured current shear values of 0.004 and 0.03 (m/s)/m. The results indicate that the adaptive controller reduced the amplitude of the cyclic axial blade loads on a rigidly mounted and moored turbine by 91.18% and 92.3% in the mean current shear and by 94.12% and 81.88% in maximum current shear demonstrating the value of this controls approach.

adaptive control↗

Design and Licensing of Irradiated Uranyl Nitrate Liquid Containers and Applicable Loading and Packaging System - 18481

Irradiated highly enriched uranyl nitrate liquid (HEUNL) solutions are typically residual materials resulting from the processing of uranium target materials in the production of radioisotopes. Traditionally, these residual materials have been processed and stored at the site of origin, due to the lack of an option for packaging, transportation and disposition. Modern alternatives to process, stabilize, package and dispose of these materials have been developed, but until recently there has not been a viable Type B package solution that could be used to ship these materials in sufficient quantities to justify the cost of an off-site disposition strategy. For this reason, most facilities that generate irradiated HEUNL materials have implemented on-site storage tanks or containers, resulting in the significant accumulation of HEUNL inventories worldwide. This paper provides an overview of the design and licensing activities for the development of sealed irradiated HEUNL transport containers to permit safe transportation of this material in the NAC Legal Weight Truck (NAC-LWT) cask. A description of the robust HEUNL container, licensing and fabrication is also presented. In addition, NAC has developed a specialized loading system to optimize the process to load, package and un-package HEUNL materials to minimize worker exposure during loading, and execute the packaging process efficiently for safe transport and retrieval. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pressure Loading with In-Situ Permeability Measurement of SiC Ceramic Matrix Composite Tube

Silicon carbide fiber in a silicon carbide matrix composite (SiC-SiC) has been actively researched as a potential structural material to be used in advanced high temperature gas reactors (HTGR) and as an accident tolerant cladding material for light water reactors (LWR). This ceramic composite material demonstrates desirable properties for use in nuclear reactor core that include retention of strength from ambient to LWR and HTGR operating and accident temperatures and stability under neutron radiation. However, the ceramic composite material must be designed to meet all the necessary, application driven requirements before it could be implemented in a reactor design. As one of the requirements for a fuel cladding material, the composite has to maintain high level of impermeability as to retain fission gases throughout the fuel cycle. General Atomics (GA) had previously reported results on permeability levels obtained by CVI produced SiC-SiC composites. It has been determined that for LWR size cladding tube that is 51 mm long the permeability allocation equivalent to currently used claddings is 7.3 E-10 atm*cc/sec. With high level of attention to possible sources of leaks in a test setup, it has been demonstrated that a CVI SiC-SiC composites produced by GA can achieve a leak rate of 1 E-12 atm*cc/sec, and therefore it meets the permeability allocation for a fuel cladding. Further study showed that a particular SiC-SiC composite tube can remain impermeable after being pressure loaded well above LWR normal operating conditions. In the study done by Deck et al., hoop stress was applied to a composite tube using pressure load on the inside surface in a load-unload stepwise sequence with increasing maximum applied stress at each step and measuring permeability between steps. The tested composite comprised of 70% thickness of SiC-SiC composite which provides fracture toughness and bears a majority of the applied stress and a 30% thickness of monolithic SiC layer on the outside surface to provide an impermeable barrier. The composite remained impermeable up to internal pressure of 56 MPa which is more than 2.5 times greater than a typical pressure at the end of life in a fuel rod.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Distributed Wind for Commercial Loads

Distributed wind can help meet on site energy and resilience needs for a wide variety of commercial loads .While it is a variable resource, it has predictable daily and annual production trends. The presence of on-site renewable generation can enhance resilience, supplying power for long periods of time without worrying about conserving fuel supply. The addition of properly sized storage or complementary solar resources can further reduce the challenges of intermittency and reduce the need for fuel-limited backup power during outage situations. This fact sheet explores further the energy and resilience requirements of commercial loads and how distributed wind may be a good match to meet their load needs.

20 FOSSIL-FUELED POWER PLANTS↗

Distributed Wind for Commercial Loads

Distributed wind can help meet on site energy and resilience needs for a wide variety of commercial loads .While it is a variable resource, it has predictable daily and annual production trends. The presence of on-site renewable generation can enhance resilience, supplying power for long periods of time without worrying about conserving fuel supply. The addition of properly sized storage or complementary solar resources can further reduce the challenges of intermittency and reduce the need for fuel-limited backup power during outage situations. This fact sheet explores further the energy and resilience requirements of commercial loads and how distributed wind may be a good match to meet their load needs.

20 FOSSIL-FUELED POWER PLANTS↗

LAF-Net: A Deep Residual and Cross-Attention Framework for Day-Ahead Load Forecasting: Preprint

Accurate day-ahead load forecasting is essential for reliable power system operations and market efficiency. System operators such as the Midcontinent Independent System Operator (MISO) rely on forecasts from multiple vendors, yet combining them effectively remains a persistent challenge due to vendor-specific biases. This paper presents a novel LSTM-Attention Fusion Network with Error Representation (LAF-Net) that enhances day-ahead hourly load forecasting through deep residual learning and multi-modal cross-attention. The proposed model builds a historical error memory from past vendor performance and dynamically queries it with future hour context to generate adaptive, hour-specific trust weights for each vendor. A bounded residual correction further refines forecasts by mitigating systematic and temporally localized errors. Tested on real MISO LBA data with multi-vendor forecasts, LAF-Net consistently outperforms the best vendor baseline across all 38 LBAs, achieving more than a 40% reduction in system-level mean absolute error (MAE) during peak load hours relative to the best vendor baseline.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parasitic load control system for exhaust temperature control

A parasitic load control system is provided. The system may include an exhaust producing engine and a fuel pumping mechanism configured to pressurize fuel in a pressure chamber. The system may also include an injection valve configured to cause fuel pressure to build within the pressure chamber when in a first position and allow injection of fuel from the pressure chamber into one or more combustion chambers of the engine when in a second position. The system may further include a controller configured to independently regulate the pressure in the pressure chamber and the injection of fuel into the one or more combustion chambers, to increase a load on the fuel pumping mechanism, increasing parasitic load on the engine, thereby increasing a temperature of the exhaust produced by the engine.

42 ENGINEERING↗

Monitoring and Characterization of Miscellaneous Electrical Loads in a Large Retail Environment

Buildings account for 40% of primary energy consumption in the United States (residential 22%; commercial 18%). Most (70% residential and 79% commercial) is used as electricity. Thus, almost 30% of U.S. primary energy is used to provide electricity to buildings. Plug loads play an increasingly critical role in reducing energy use in new buildings (because of their increased efficiency requirements), and in existing buildings (as a significant energy savings opportunity). If all installed commercial building miscellaneous electrical loads (CMELs) were replaced with energy-efficient equipment, a potential annual energy saving of 175 TWh, or 35% of the 504 TWh annual energy use devoted to MELs, could be achieved. This energy saving is equivalent to the annual energy production of 14 average-sized nuclear power plants. To meet DOE's long-term goals of reducing commercial building energy use and carbon emissions, the energy efficiency community must better understand the components and drivers of CMEL energy use, and develop effective reduction strategies. These goals can be facilitated through improved data collection and monitoring methodologies, and evaluation of CMELs energy-saving techniques.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗