Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “life testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Application of the Life Safety Code to a Historic Test Stand

NASA has conducted a study to assess alternatives to refurbishing existing launch vehicle modal test facilities as opposed to developing new test facilities to meet the demands of a very fiscally constrained test and evaluation environment. The results of this study showed that Marshall Space Flight Center (MSFC) Test Stand (TS) 4550 could be made compliant, within reasonable cost and schedule impacts, if safety processes and operational limitations were put in place to meet the safety codes and concerns of the Fire Marshall. Trades were performed with key selection criteria to ensure that appropriate levels of occupant safety are incorporated into test facility design modifications. In preparation for the ground vibration tests that were to be performed on the Ares I launch vehicle, the Ares Flight and Integrated Test Office (FITO) organization evaluated the available test facility options, which included the existing mothballed structural dynamic TS4550 used by Apollo and Shuttle, alternative ground vibration test facilities at other locations, and construction of a new dynamic test stand. After an exhaustive assessment of the alternatives, the results favored modifying the TS4550 because it was the lowest cost option and presented the least schedule risk to the NASA Constellation Program for Ares Integrated Vehicle Ground Vibration Test (IVGVT). As the renovation design plans and drawings were being developed for TS4550, a safety concern was discovered the original design for the construction of the test stand, originally built for the Apollo Program and renovated for the Shuttle Program, was completed before NASA s adoption of the currently imposed safety and building codes per National Fire Protection Association Life Safety Code [NFPA 101] and International Building Codes. The initial FITO assessment of the design changes, required to make TS4550 compliant with current safety and building standards, identified a significant cost increase and schedule impact. An effort was launched to thoroughly evaluate the applicable life safety requirements, examine the context in which they were derived, and determine a means by which the TS4550 modifications could be made within budget and on schedule, while still providing the occupants with appropriate levels of safety.

Askins, Bruce↗

Rolling-element fatigue life of silicon nitride balls: Preliminary test results

Hot pressed silicon nitride was evaluated as a rolling element bearing material. The five-ball fatigue tester was used to test 12.7 mm (0.500 in.) diameter balls at a maximum Hertz stress of 800,000 psi at a race temperature of 130 F. The fatigue spalls in the silicon nitride resembled those in typical bearing steels. The ten-percent fatigue life of the silicon nitride balls was approximately one-eighth to one-fifth that of typical bearing steels (52100 and M-50). The load capacity of the silicon nitride was approximately one-third that of typical bearing steels. The load capacity of the silicon nitride was significantly higher than previously tested ceramic materials for rolling element bearings.

Parker, R. J.↗

Quantification and Characterization of Volatiles Evolved During Extrusion of Rice and Soy Flours

NASA Johnson Space Center is designing and building a habitat (Bioregenerative Planetary Life Support Systems Test Complex, BIO-Plex) intended for evaluating advanced life support systems developed for long duration missions to the Moon or Mars where all consumables will be recycled and reused. A food system based on raw products obtained from higher plants (such as soybeans, rice and wheat) may be a central feature of a biological ly-based Advanced Life Support System (ALSS). In order to convert raw crops to edible ingredients or food items, multipurpose processing equipment such as an extruder is ideal. Volatile compounds evolved during the manufacturing of these food products may accumulate reaching toxic levels. Additionally, off-odors often dissipated in open-air environments without consequence, may cause significant discomfort in the BIO-Plex. Rice and defatted soy flours were adjusted to 16% moisture and triplicate samples were extruded using a table top single-screw extruder. The extrudate was collected in specially designed Tedlar bags from which air samples could be extracted. The samples were analyzed by GC-MS with special emphasis on compounds with Spacecraft Maximum Allowable Concentrations (SMAC). Results showed a combination of alcohols, aldehydes, ketones and carbonyl compounds in the different flours. Each compound and its SMAC value as well as its impact on the air revitalization system was discussed.

Zasypkin, D.↗

Quantification and characterization of volatiles evolved during extrusion of rice and soy flours

NASA-Johnson Space Center is designing and building a habitat (Bioregenerative Planetary Life Support Systems Test Complex, BIO-Plex) intended for evaluating advanced life support systems developed for long-duration missions to the Moon or Mars where all consumables will be recycled and reused. A food system based on raw products obtained from higher plants (such as soybeans, rice, and wheat) may be a central feature of a biologically based Advanced Life Support System. To convert raw crops to edible ingredients or food items, multipurpose processing equipment such as an extruder is ideal. Volatile compounds evolved during the manufacturing of these food products may accumulate and reach toxic levels. Additionally, off-odors often dissipated in open-air environments without consequence may cause significant discomfort in the BIO-Plex. Rice and defatted soy flours were adjusted to 16% moisture, and triplicate samples were extruded using a tabletop single-screw extruder. The extrudate was collected in specially designed Tedlar bags from which air samples could be extracted. The samples were analyzed by GC-MS with special emphasis on compounds with Spacecraft Maximum Allowable Concentrations (SMACs). Results showed a combination of alcohols, aldehydes, ketones, and carbonyl compounds in the different flours. Each compound and its SMAC value, as well as its impact on the air revitalization system, was discussed.

Non-NASA Center↗

Phytoremediation of Indoor Air: NASA, Bill Wolverton, and the Development of an Industry

It was during this period of the early 1970's and 1980's when the issues associated with Sick Building Syndrome were gaining attention that the United States National Aeronautics and Space Administration (NASA) became an unlikely leader in identifying biological solutions to the problem of poor indoor air quality. NASA had been supporting work using biological systems for atmospheric regeneration since the 1950's, with the emphasis on using photosynthetic systems for the removal of carbon dioxide and regeneration of oxygen as part of a life support system. The then Soviet Union was conducting tests using algae systems in the BIO-1 program (1964-1968) to regenerate the air at the Siberian Branch of the Soviet Academy of Sciences in Krasnoyarsk (Later renamed the Institute of Biophysics). These tests were expanded to include the use of higher plants in the BIOS-2 testing in the 1970's, and humans during BIO-3 in the 1980'SI3. Within NASA, large scale testing of bioregenerative life support systems was conducted in the Biomass Production Chamber (BPC) at Kennedy Space Center, Florida as part of the Controlled Ecological Life Support Systems (CELSS) Breadboard project.

Stutte, Gary W.↗

Space Suit Portable Life Support System (PLSS) 2.0 Pre-Installation Acceptance (PIA) Testing

Following successful completion of the space suit Portable Life Support System (PLSS) 1.0 development and testing in 2011, the second system-level prototype, PLSS 2.0, was developed in 2012 to continue the maturation of the advanced PLSS design which is intended to reduce consumables, improve reliability and robustness, and incorporate additional sensing and functional capabilities over the current Space Shuttle/International Space Station Extravehicular Mobility Unit (EMU) PLSS. PLSS 2.0 represents the first attempt at a packaged design comprising first generation or later component prototypes and medium fidelity interfaces within a flight-like representative volume. Pre-Installation Acceptance (PIA) is carryover terminology from the Space Shuttle Program referring to the series of test sequences used to verify functionality of the EMU PLSS prior to installation into the Space Shuttle airlock for launch. As applied to the PLSS 2.0 development and testing effort, PIA testing designated the series of 27 independent test sequences devised to verify component and subsystem functionality, perform in situ instrument calibrations, generate mapping data to define set-points for control algorithms, evaluate hardware performance against advanced PLSS design requirements, and provide quantitative and qualitative feedback on evolving design requirements and performance specifications. PLSS 2.0 PIA testing was carried out from 3/20/13 - 3/15/14 using a variety of test configurations to perform test sequences that ranged from stand-alone component testing to system-level testing, with evaluations becoming increasingly integrated as the test series progressed. Each of the 27 test sequences was vetted independently, with verification of basic functionality required before completion. Because PLSS 2.0 design requirements were evolving concurrently with PLSS 2.0 PIA testing, the requirements were used as guidelines to assess performance during the tests; after the completion of PIA testing, test data served to improve the fidelity and maturity of design requirements as well as plans for future advanced PLSS functional testing.

Watts, Carly↗

Space Suit Portable Life Support System (PLSS) 2.0 Pre-Installation Acceptance (PIA) Testing

Following successful completion of the space suit Portable Life Support System (PLSS) 1.0 development and testing in 2011, the second system-level prototype, PLSS 2.0, was developed in 2012 to continue the maturation of the advanced PLSS design. This advanced PLSS is intended to reduce consumables, improve reliability and robustness, and incorporate additional sensing and functional capabilities over the current Space Shuttle/International Space Station Extravehicular Mobility Unit (EMU) PLSS. PLSS 2.0 represents the first attempt at a packaged design comprising first generation or later component prototypes and medium fidelity interfaces within a flight-like representative volume. Pre-Installation Acceptance (PIA) is carryover terminology from the Space Shuttle Program referring to the series of test sequences used to verify functionality of the EMU PLSS prior to installation into the Space Shuttle airlock for launch. As applied to the PLSS 2.0 development and testing effort, PIA testing designated the series of 27 independent test sequences devised to verify component and subsystem functionality, perform in situ instrument calibrations, generate mapping data, define set-points, evaluate control algorithms, evaluate hardware performance against advanced PLSS design requirements, and provide quantitative and qualitative feedback on evolving design requirements and performance specifications. PLSS 2.0 PIA testing was carried out in 2013 and 2014 using a variety of test configurations to perform test sequences that ranged from stand-alone component testing to system-level testing, with evaluations becoming increasingly integrated as the test series progressed. Each of the 27 test sequences was vetted independently, with verification of basic functionality required before completion. Because PLSS 2.0 design requirements were evolving concurrently with PLSS 2.0 PIA testing, the requirements were used as guidelines to assess performance during the tests; after the completion of PIA testing, test data served to improve the fidelity and maturity of design requirements as well as plans for future advanced PLSS functional testing.

Anchondo, Ian↗

Report on FY19 Testing in Support of Integrated EPP-SMT Design Methods Development

Experiments in support of the development of the integrated Elastic–Perfectly Plastic (EPP) analysis and Simplified Model Test (SMT) design methodology continued in FY 2019. Major progress was made in the verification of the newly developed two-bar SMT and single-bar SMT (SBSMT) methods by performing tests on Alloy 617 and SS 316H at high temperatures. Comparable results were achieved when the materials were tested under same conditions using both techniques. Because of its simple test configuration, SBSMT was the preferred testing technique used to evaluate elastic follow-up effect and generate data in support of SMT-based design curves. Evaluation of elastic follow-up was started with testing SS 316H at 815°C using SBSMT in this reporting period. As a result of this effort, the basic procedure and test protocol to provide data in support of the development of SMT-based design curves were established. This report also summarizes recent test results for the pressurization SMT using test articles with key features on Alloy 617 at intermediate strain ranges and at a low temperature of 850°C. Although more test results are needed in order to fully understand the effect of primary load on SMT creep-fatigue (CF) life, the limited test data indicate that the primary load reduced the SMT life at intermediate strain ranges and high temperatures. Recognizing the advantages of the newly developed SBSMT method, a new test geometry was designed to allow the elevation of the primary load effect on SMT CF life with the SBSMT technique. Additionally, selected tests were performed on SS 316H (heat 101076) to provide basic information about the heat of material. The tests performed included high-temperature tensile, fatigue, creep fatigue, and thermomechanical experiments. The results will be used to support the verification of the material constitutive model developed at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

Integrated Human Test Facilities at NASA and the Role of Human Engineering

Integrated human test facilities are a key component of NASA's Advanced Life Support Program (ALSP). Over the past several years, the ALSP has been developing such facilities to serve as a large-scale advanced life support and habitability test bed capable of supporting long-duration evaluations of integrated bioregenerative life support systems with human test crews. These facilities-targeted for evaluation of hypogravity compatible life support and habitability systems to be developed for use on planetary surfaces-are currently in the development stage at the Johnson Space Center. These major test facilities are comprised of a set of interconnected chambers with a sealed internal environment, which will be outfitted with systems capable of supporting test crews of four individuals for periods exceeding one year. The advanced technology systems to be tested will consist of both biological and physicochemical components and will perform all required crew life support and habitability functions. This presentation provides a description of the proposed test "missions" to be supported by these integrated human test facilities, the overall system architecture of the facilities, the current development status of the facilities, and the role that human design has played in the development of the facilities.

Tri, Terry O.↗

Space Suit Portable Life Support System Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure control for the crew member during prebreathe, Extra-Vehicular Activity (EVA), post EVA airlock operations, and Decompression Sickness (DCS) treatment. It has been over four decades since a new spacesuit oxygen regulator has been designed. The regulator and EMU that is presently used on the International Space Station (ISS) was developed for the space shuttle program without any significant changes made throughout its service life. The xEMU spacesuit oxygen regulator is based on the previous EMU Secondary Oxygen Pack (SOP). The new design integrates numerous improvements and changes including an innovative approach to regulator architecture, a more robust first stage pressure sensing mechanism, digital actuation control, and electronic pressure sensing. These upgrades replace manual control linkages, physical gauges, and enable infinitely variable pressure set points. The new setpoints can decrease prebreathe time and make in suit DCS treatment possible. Throughout its four iterations design concerns have been addressed, safety features have been added, and the envelope of the regulator designed to fit inside the xEMU PLSS package. This paper will review the history, design, testing, and lessons learned during the development of the xEMU PLSS Oxygen Regulator.

Ryan Eric Ogilvie↗

Development of an Accelerated Test Design for Predicting the Service Life of the Solar Array at Mead, Nebraska

Potential long-term degradation modes for the two types of modules in the Mead array were determined and judgments were made as to those environmental stresses and combinations of stresses which accelerate the degradation of the power output. Hierarchical trees representing the severity of effects of stresses (test conditions) on eleven individual degradation modes were constructed and were pruned of tests judged to be nonessential. Composites of those trees were developed so that there is now one pruned tree covering eight degradation modes, another covering two degradation modes, and a third covering one degradation mode. These three composite trees form the basis for selection of test conditions in the final test plan which is now being prepared.

Gaines, G. B.↗

Metallurgical aspects influencing the resistance to steam oxidation and fracture toughness of select advanced replacement alloys for LWR core internals

Life extension of the existing nuclear reactors imposes accumulated damages, such as higher fluences and longer period of corrosion, to structural materials, which would result in significant challenges to the traditional reactor materials such as type 304 and 316 stainless steels. Advanced alloys with superior radiation resistance will increase safety margins, design flexibility, and economics for not only the life extension of the existing fleet but also new builds with advanced reactor designs. The Electric Power Research Institute (EPRI) teamed up with Department of Energy (DOE) to initiate the Advanced Radiation Resistant Materials (ARRM) program, aiming to develop and test degradation resistant alloys from current commercial alloy specifications by 2021 to a new advanced alloy with superior degradation resistance in light water reactor (LWR)-relevant environments by 2024. Corrosion resistance in water environment is one of the fundamental properties required for LWR core internal materials. High-temperature steam oxidation tests are not only an accelerated life testing method to uncover potential failure modes in a short period of time, but also an approach to evaluate materials’ resistance to accidental scenarios. Coupons, prepared from fourteen candidate alloys that were selected under the ARRM program, were exposed to 1 bar full steam with ~10 part-per-billion oxygen content at 600 and 650°C for up to 5,000 h, which were weighed at 500-h intervals. Ni-base superalloys are an important class of alloys for reactor applications. Alloys 690, 725, and X- 750 were three of the selected Ni-base superalloys exposed to the steam tests. This report summarizes the metallurgical aspects, such as alloy thermodynamics and the nature of the oxides and the diffusivities of primary elements, and their effects on oxidation behavior of the three alloys. In addition to monitoring mass change, microstructures of the 5000h-exposed samples of alloys 690, 725, and X-750 were characterized using scanning and transmission electron microscopy and energy dispersive x-ray spectroscopy. Together with thermodynamic calculations, the scale constitution and its exfoliation behavior were discussed. Based on experimental and theoretical values, a new model was proposed to quantitatively estimate the metal thickness loss of the alloys. Alloy X-750 was found to have the best resistance to steam oxidation with the least metal thickness loss (<1 μm), which were slightly superior to alloy 690. Alloy 725 exhibited the worst resistance to steam oxidation with the greatest metal thickness loss, e.g., ~2.5 μm at 650°C, which is nearly three times of the metal thickness losses of alloys 690 and X-750 at 650°C. The greatest metal thickness loss of alloy 725 might be attributable to its high Mo content. Photos of the fracture toughness tested samples of eight alloys are presented, which will be correlated with their fracture toughness results and planned tensile test results to select representative alloy samples for detailed microstructural characterization to reveal their microstructure and properties relationships.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Control Rod Life Time Considerations for the Versatile Test Reactor

The Versatile Test Reactor (VTR) is a fast spectrum test reactor currently being developed under the direction of the US Department of Energy, Office of Nuclear Energy. VTR will use two independent reactivity control systems: a primary and a secondary reactivity control system. Boron carbide (B 4 C) is the favored absorber material due to the extensive domestic and international experience. The life limit of control rod is analyzed in this report, based on the depletion of B-10, diametral swelling of B 4 C pellet and pressure buildup in the gas plenum. Depletion analysis of the absorber material was performed using MCNP6. It is was shown that both the concentration of B-10 and the CR reactivity worth are about linear with the irradiation time. In the preliminary VTR design, natural boron is considered as absorber material and was determined to provide just enough reactivity worth. Several alternate design options were also analyzed to improve the control rods worth (i.e. increase the shutdown reactivity margin). Using enriched boron as absorber material could increase the control rods worth, while having several drawbacks, such as reduced core excess reactivity, shorter lifetime, and larger peak centerline temperatures. A mitigation strategy to using enriched boron is to use both natural and enriched boron in the control rod, with the natural boron in the lower region of the pins and the enriched boron in the upper region. This design option still allows increasing the CR reactivity worth significantly, while maintaining all the advantages of natural boron.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lubricant and additive effects on spur gear fatigue life

Spur gear endurance tests were conducted with six lubricants using a single lot of consumable-electrode vacuum melted (CVM) AISI 9310 spur gears. The sixth lubricant was divided into four batches each of which had a different additive content. Lubricants tested with a phosphorus-type load carrying additive showed a statistically significant improvement in life over lubricants without this type of additive. The presence of sulfur type antiwear additives in the lubricant did not appear to affect the surface fatigue life of the gears. No statistical difference in life was produced with those lubricants of different base stocks but with similar viscosity, pressure-viscosity coefficients and antiwear additives. Gears tested with a 0.1 wt % sulfur and 0.1 wt % phosphorus EP additives in the lubricant had reactive films that were 200 to 400 (0.8 to 1.6 microns) thick.

Townsend, D. P.↗

Lubricant and additive effects on spur gear fatigue life

Spur gear endurance tests were conducted with six lubricants using a single lot of consumable-electrode vacuum melted (CVM) AISI 9310 spur gears. The sixth lubricants was divided into four batches each of which had a different additive content. Lubricant tested with a phosphorus-type load carrying additive showed a statistically significant improvement in life over lubricants without this type of additive. The presence of sulfur type antiwear additives in the lubricant did not appear to affect the surface fatigue life of the gears. No statistical difference in life was produced with those lubricants of different base stocks but with similar viscosity, pressure-viscosity coefficients and antiwar additives. Gears tested with a 0.1 wt pct sulfur and 0.1 wt pct phosphorus EP additives in the lubricant had reactive films that were 200 to 400 (0.8 to 1.6 microns) thick.

Townsend, D. P.↗

Space Suit Portable Life Support System Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the space suit Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure for the crew member during pre-breathe, extra-vehicular activity (EVA), post EVA airlock operations, and decompression sickness treatment. The last time a spacesuit oxygen regulator was designed was for the Space Shuttle Program EMU. The regulator & EMU were then used on the International Space Station (ISS) with no significant changes to the regulator throughout its life. This xEMU PLSS spacesuit oxygen regulator implements many elements of the previous EMU Secondary Oxygen Pack (SOP) design while integrating numerous new improvements and changes. There are changes both to the high-level regulator architecture approach in the suit itself, in addition to modernizations with electrical motor control & sensing. For architecture, there are two oxygen regulators for each space suit, a primary and secondary that are nearly identical to each other and have the same maximum design pressure of 3750 Pounds per Square Inch Absolute (PSIA). The primary regulator provides nominal pressure during EVA, while the secondary provides a backup pressure only in case of primary regulator failure or if an emergency purge of the suit oxygen is required. The design was based originally off of the secondary oxygen regulator on the EMU which utilizes a two-stage regulator to improve safety and controllability. The xEMU PLSS Oxygen Regulator development started with a modification to add a linear actuator to the design to control the downstream pressure electronically instead of a manual control with a wire linkage system used with the EMU. The design was iterated to include a Monel body for oxygen fire safety, and sensors for pressure verification at each stage. Then the regulator design was packaged to fit into the xEMU PLSS envelope. Development included extensive testing which brought to light some issues with the design which were addressed at each stage of development. This paper will review the design history, development, testing results, and lessons learned designing the xEMU PLSS Oxygen Regulator.

Ryan Ogilvie↗

Test Analysis Guidelines

Development of analysis guidelines for Exploration Life Support (ELS) technology tests was completed. The guidelines were developed based on analysis experiences gained from supporting Environmental Control and Life Support System (ECLSS) technology development in air revitalization systems and water recovery systems. Analyses are vital during all three phases of the ELS technology test: pre-test, during test and post test. Pre-test analyses of a test system help define hardware components, predict system and component performances, required test duration, sampling frequencies of operation parameters, etc. Analyses conducted during tests could verify the consistency of all the measurements and the performance of the test system. Post test analyses are an essential part of the test task. Results of post test analyses are an important factor in judging whether the technology development is a successful one. In addition, development of a rigorous model for a test system is an important objective of any new technology development. Test data analyses, especially post test data analyses, serve to verify the model. Test analyses have supported development of many ECLSS technologies. Some test analysis tasks in ECLSS technology development are listed in the Appendix. To have effective analysis support for ECLSS technology tests, analysis guidelines would be a useful tool. These test guidelines were developed based on experiences gained through previous analysis support of various ECLSS technology tests. A comment on analysis from an experienced NASA ECLSS manager (1) follows: "Bad analysis was one that bent the test to prove that the analysis was right to begin with. Good analysis was one that directed where the testing should go and also bridged the gap between the reality of the test facility and what was expected on orbit."

Jeng, Frank F.↗

Continuing the biological exploration of Mars

Mars has been an object of interest for the better part of this century. To a biologist, Mars assumes special importance because many aspects of the theory of chemical evolution for the origin of life can be tested there. The central idea of this theory is that life on a suitable planet arises through a process in which the so-called biogenic elements combine to form increasingly more complex molecules under the influence of naturally-occurring energy sources ultimately resulting in the formation of replicating organic molecules. The biogenic elements are present on Mars today. Furthermore, the available evidence also strongly suggests that Mars may have had an early history similar to that of the Earth, including a period in which large amounts of liquid water once flowed on its surface and a denser atmosphere and higher global temperatures prevailed. This is important since many lines of evidence indicate that living organisms were already present on the Earth within the first billion years after its formation at a time when the environment on Mars may have closely resembled that of Earth. Our current knowledge of the state of chemical evolution on Mars can best be described as paradoxical. Most of what we have learned has come from experiments performed on the Viking landers. The combination of planned investigations covered a broad range of techniques to detect signs of chemical evolution. The most surprising data from all of these was the absence of any detectable quantities of organic compounds at the two landing sites. On the other hand, the Viking experiments did indicate that the Martian surface samples contained unidentified strong oxidant(s) that could account for their absence.

Klein, Harold P.↗