Nickel/carbon core/shell nanotubes: Lanthanum nickel alloy catalyzed synthesis, characterization and studies on their ferromagnetic and lithium-ion storage properties

Highlights: • Ni/CNTs core/shell structure was synthesized using LaNi{sub 5} alloy catalyst by CVD. • The magnetic and lithium-ion storage properties of Ni/CNTs structure were studied. • The specific Ni/CNTs structure shows strong ferromagnetic property with large coercivity value of 446.42 Oe. • Ni/CNTs structure shows enhanced electrochemical performance in terms of stable capacity and better rate capability. - Abstract: A method was developed to synthesize ferromagnetic nickel core/carbon shell nanotubes (Ni/CNTs) by chemical vapor deposition using Pauli paramagnetic lanthanum nickel (LaNi{sub 5}) alloy both as a catalyst and as a source for the Ni-core. The Ni-core was obtained through oxidative dissociation followed by hydrogen reduction during the catalytic growth of the CNTs. Transmission electron microscopy (TEM), selected area electron diffraction (SAED) and X-ray diffraction (XRD) analyses reveal that the Ni-core exists as a face centered cubic single crystal. The magnetic hysteresis loop of Ni/CNTs particle shows increased coercivity (446.42 Oe) than bulk Ni at room temperature. Furthermore, the Ni/CNTs core/shell particles were investigated as anode materials in lithium-ion batteries. The Ni/CNTs electrode delivered a high discharge capacity of 309 mA h g{sup −1} at 0.2 C, and a stable cycle-life, which is attributed to high structural stability of Ni/CNTs electrode during electrochemical lithium-ion insertion and de-insertion redox reactions.

36 MATERIALS SCIENCE↗

A novel iron phosphate/oxygen hybrid cathode with high power output for the aprotic lithium-oxygen battery

Highlights: • This study affords a new strategy to improve the power output of Li-O{sub 2} cell. • FePO{sub 4}@C nanorods with exposed {010} facets are prepared and applied in O{sub 2} cathode. • Hybrid cathode retains high energy output via ORR. • Hybrid cathode attains 8-fold increased power output via Li{sup +}-insertion of FePO{sub 4}. - Abstract: The aprotic lithium-oxygen (Li-O{sub 2}) battery has recently attracted the worldwide attention by virtue of its super-large energy output. However, the extremely poor power output is one of the key issues which severely restrict the commercialization of the Li-O{sub 2} technology. In this work, we demonstrate a novel and simple strategy to address the power issue of the aprotic Li-O{sub 2} battery. An iron phosphate/oxygen (FePO{sub 4}/O{sub 2}) hybrid cathode is proposed for the first time by simply introducing the {010}-oriented FePO{sub 4} nanorods into a conventional O{sub 2} cathode. The as-built hybrid cathode not only retains a high-energy output via the O{sub 2} cathodic reaction, but also achieves an 8-fold increased power output via the Li{sup +}-insertion reaction of the {010}-oriented FePO{sub 4} nanorods.

36 MATERIALS SCIENCE↗

The GdF3 phosphors with enhanced multicolor luminescence via multi-channel excitation and energy migration procedure

Highlights: • Core-shell structured GdF{sub 3} phosphors were synthesized by hydrothermal method. • SiO{sub 2} coating layers prevent aggregation and sintering during thermal annealing. • The annealed CSS nanophosphors were highly dispersible. • The inserted PMA significantly enhances multicolor luminescence. • The annealed CSS phosphors exhibit enhanced multicolor luminescence properties. - Abstract: A collection of GdF{sub 3} core-shell structured (CSS) phosphors were synthesized by hydrothermal method. The as-prepared (AP) phosphors were coated with SiO{sub 2} layers to avoid aggregation and sintering during thermal annealing at 800 °C, after which the SiO{sub 2} layers were etched off and the annealed phosphors became highly dispersible. The annealed CSS phosphor aGdF{sub 3}:Eu{sup 3+}@GdF{sub 3}:Ce{sup 3+},Dy{sup 3+} shows excellent multicolor luminescence performance with the aid of dual-channel excitation and energy migration (EM) procedure of Gd{sup 3+} ions. By inserting pyromellitic acid (PMA) organic ligands into the interfaces between annealed core and AP shell layer regions, the so-called antenna effect of organic ligands of PMA forms a new excitation channel, which makes the CSS phosphor aGdF{sub 3}:Eu{sup 3+}@PMA@GdF{sub 3}:Ce{sup 3+},Dy{sup 3+} exhibit significantly enhanced multicolor luminescence via multi-channel excitation and EM process. The prepared CSS phosphors in this work are excellent candidates for applications in solid-state lighting.

36 MATERIALS SCIENCE↗

Effects of channel thickness on structure and transport properties of AlGaN/InGaN heterostructures grown by pulsed metal organic chemical vapor deposition

Highlights: • High quality AlGaN/InGaN heterostructures are grown and the effects of InGaN channel thickness on the structural and transport properties are investigated in detailed. • A high electron mobility of 1712 cm{sup 2}/Vis achieved for the heterostructures with an optimum channel thickness of 21 nm, indicating the huge potential of InGaN channel heterostructures in high frequency and high power applications. • The analyze method in this work can be generalized to both the studies of InGaN channel heterostructures with arbitrary component and all the heterostructures with inserted channel. - Abstract: High-quality AlGaN/InGaN heterostructures are grown and the effects of InGaN channel thickness on the structure and transport properties are investigated. With the increase of InGaN channel thickness from 7 nm to 28 nm, the two-dimensional electron gas density decreases continuously, while the mobility shows a trend of increasing at first, and then decreasing. The optimum thickness of 21 nm is obtained for the In{sub 0.05}Ga{sub 0.95}N channel, achieving a high electron mobility of 1712 cm{sup 2}/V, which indicates the huge potential for InGaN channel heterostructures in high-frequency and high-power applications. The variation in transport properties is studied by analyzing the structure formation, material quality, and interface characteristic in detail. The results are not only beneficial for the further study of the InGaN channel heterostructures, but also instructive for the other inserted channel system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Utility of Megavoltage Fan-Beam CT for Treatment Planning in a Head-And-Neck Cancer Patient with Extensive Dental Fillings Undergoing Helical Tomotherapy

The purpose of this study was to demonstrate the potential utility of megavoltage fan-beam computed tomography (MV-FBCT) for treatment planning in a patient undergoing helical tomotherapy for nasopharyngeal carcinoma in the presence of extensive dental artifact. A 28-year-old female with locally advanced nasopharyngeal carcinoma presented for radiation therapy. Due to the extensiveness of the dental artifact present in the oral cavity kV-CT scan acquired at simulation, which made treatment planning impossible on tomotherapy planning system, MV-FBCT imaging was obtained using the HI-ART tomotherapy treatment machine, with the patient in the treatment position, and this information was registered with her original kV-CT scan for the purposes of structure delineation, dose calculation, and treatment planning. To validate the feasibility of the MV-FBCT-generated treatment plan, an electron density CT phantom (model 465, Gammex Inc., Middleton, WI) was scanned using MV-FBCT to obtain CT number to density table. Additionally, both a 'cheese' phantom (which came with the tomotherapy treatment machine) with 2 inserted ion chambers and a generic phantom called Quasar phantom (Modus Medical Devices Inc., London, ON, Canada) with one inserted chamber were used to confirm dosimetric accuracy. The MV-FBCT could be used to clearly visualize anatomy in the region of the dental artifact and provide sufficient soft-tissue contrast to assist in the delineation of normal tissue structures and fat planes. With the elimination of the dental artifact, the MV-FBCT images allowed more accurate dose calculation by the tomotherapy system. It was confirmed that the phantom material density was determined correctly by the tomotherapy MV-FBCT number to density table. The ion chamber measurements agreed with the calculations from the MV-FBCT generated phantom plan within 2%. MV-FBCT may be useful in radiation treatment planning for nasopharyngeal cancer patients in the setting of extensive dental artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A rationally designed polysulfide-trapping interface on the polymeric separator for high-energy Li–S batteries

A coating layer consisting of a layer of graphene oxide (GO) inserted in between two layers of multi-walled carbon nanotubes (MWCNT) forms a multifunctional polysulfide-trapping triple-interface on the polymeric separator for lithium–sulfur (Li–S) batteries. The top and bottom highly conductive MWCNT interfaces are able to physically inhibit polysulfide diffusion and effectively reutilize the trapped active material during cycling. The inserted ultrathin GO layer with negatively charged carboxyl groups, on the other hand, electrostatically repels the migrating polysulfide anions. The stacked GO sheets also extensively prolong the migration routes of the polysulfides. Additionally, the “buffer zones” interspersed within the triple-interface accommodate the migrating polysulfides. Thus, the sandwiched separators enable Li–S cells with a high-sulfur-loading (10 mg cm -2 ), high areal capacity (10.9 mA h cm -2 ), and stable cycling ability even though the coating layer is ultra-thin (~17 μm) and light-weight (~0.23 mg cm -2 ).

25 ENERGY STORAGE↗

NASICON-type Na 3 Fe 2 (PO 4 ) 3 as a low-cost and high-rate anode material for aqueous sodium-ion batteries

Aqueous sodium-ion batteries are attractive battery alternatives for stationary energy storage due to their inherently low cost and high safety. The development of advanced electrode materials with excellent performance and low cost is crucial for the success of aqueous Na-ion batteries. Albeit the high capacity and stable cycling of the leading anode of NaTi 2 (PO 4 ) 3 , the high price of titanium element and the low Na-insertion potential close to the hydrogen evolution reaction may plague its application. Here we introduced a NASICON-type Na 3 Fe 2 (PO 4 ) 3 as a promising anode alternative for aqueous Na-ion batteries. Synchrotron X-ray diffraction and spectroscopy confirm its phase and atomic structure. Electrochemical characterization and X-ray photoelectron spectroscopy reveal the reversible Na+ insertion in Na 3 Fe 2 (PO 4 ) 3 due to the Fe 3+ /Fe 2+ redox couple, which renders a specific capacity of ~60 mAh g -1 and excellent cycling of 1000 cycles at 10C rate. A Super high rate of 100C was also achieved for this anode with a capacity retention of 61% after 1000 cycles. In addition, the Na 3 Fe 2 (PO 4 ) 3 anode is paired with a Prussian white analogue of Na 2 Mn[Fe(CN) 6 ] into a full cell, exhibiting promising cell performance and material sustainability. Furthermore, our work underlines the importance of fabricating aqueous batteries on the basis of the Earth-abundant, cost-effective, and non-toxic elements.

25 ENERGY STORAGE↗

Probing local electrochemistry via mechanical cyclic voltammetry curves

Understanding the mechanical response of an electrode during electrochemical cycling and its correlation to the device electrochemical performance is crucial to improving the performance of insertion-type energy storage devices, electrochemical actuators, water purification, ion separation and neuromorphic computing applications. Here, we visualized the electro-chemo-mechanical coupling behaviors during charge storage of anhydrous and hydrated WO 3 electrodes via in situ atomic force microscopy (AFM) and developed the concept of mechanical cyclic voltammetry (mCV) curves. The relationship between electrochemical current and strain was investigated with simplified models and the results revealed that the proton insertion/deinsertion process could be described through potential-dependent electro-chemo-mechanical coupling coefficients which might indicate changes in insertion processes during electrode cycling. The mCV mapping results highlight the local heterogeneity and show that the charging processes varied across the electrode. These local variations could be further correlated to local morphology, crystal orientations or chemical compositions with proper electrode designs.

36 MATERIALS SCIENCE↗

New SRC APPLE ll Variable Polarization Beamline

SRC has recently commissioned a new Varied Line-Spacing Plane Grating Monochromator (VLS-PGM) utilizing as its source a 1 m long APPLE II insertion device in short-straight-section 9 of the Aladdin storage ring. The insertion device reliably delivers horizontal, vertical, and right and left circularly polarized light to the beamline. Measurements from an in situ polarimeter can be used for undulator corrections to compensate for depolarizing effects of the beamline. The beamline has only three optical elements and covers the energy range from 11.1 to 270 eV using two varied line-spacing gratings. A plane mirror rotates to illuminate the gratings at the correct angle to cancel the defocus term at all photon energies. An exit slit and elliptical-toroid refocusing mirror complete the beamline. Using a 50 {mu}m exit slit, the beamline provides moderate to high resolution, with measured flux in the mid 10{sup 12} (photons/s/200 mA) range, and a spot size of 400 {mu}m horizontal by 30 {mu}m vertical.

43 PARTICLE ACCELERATORS↗

Off-axis viewing of radiation emission by long wiggler sources

When high-brilliance radiation is needed for experiments, insertion device sources are generally viewed on-axis. Off-axis emission of flux can be prodigious especially from wiggler sources having large emission fans. The on-axis and off-axis radiation emission characteristics from insertion device sources have been calculated extensively and are well known, but experimental verifications of some characteristics, particularly those associated with off-axis emission, are relatively few. Here measurements of the flux spectrum and apparent source size are described, as a function of horizontal emission angle, from the former X25 hybrid wiggler at the National Synchrotron Light Source (NSLS).

36 MATERIALS SCIENCE↗

Validation and uncertainty quantification of detector response functions for a $1"×2"$ NaI collimated detector intended for inverse radioisotope source mapping applications

Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Failure investigation and mitigation after experimental research reactor fuel plate deformation in an irradiation device

Experimental research reactor fuel testing is conducted in the Belgian Reactor 2 (BR2) of the Belgian Nuclear Research Centre (SCK CEN) in dedicated irradiation vehicles or rigs. One such vehicle allows flat full-size fuel plates to be irradiated by inserting them into slotted baskets that captures a narrow portion of the longitudinal edges of the plates. The motion of the fuel plates within the baskets is possible within the narrow slots and thus, the plate is considered to be unattached. The design intentionally omits fixing mechanisms of the fuel plates to the baskets to facilitate the inspection and repositioning of the plates between the irradiation cycles and the accommodation of thermal expansion of the plates in the lateral direction. However, loosely inserted fuel plates have weak structural boundary conditions allowing for larger out-of-plane deflections caused by hydrodynamic loads exerted by the flowing coolant, as compared to those of fixed plates. Unexpected large deformations of plates occurred in several irradiation cycles that further resulted in a loss of cladding integrity. These deformations could not be attributed to a single source. This triggered a series of thermal hydraulic, structural, and fluid-structure interaction analyses aiming at understanding the observed phenomenon. The analyses revealed that, for a certain combination of unfavorable manufacturing and assembly tolerances, fuel plate edges could escape out of the slots in the irradiation basket due to the hydrodynamic load. Subsequently, the plate could become wedged inside the basket coolant channel opening. This resulted in reduced coolant flow and accelerated temperature increase and thermal expansion of the plate while under irradiation. This unfavorable feedback loop could then lead to excessive plate surface temperatures, deformed plates and cladding failure, as was observed in the experiments. These analyses not only provided a probable cause of the fuel plate failures, but also resulted in a new and improved design of the irradiation basket to avoid these issues in the future. In conclusion, a series of recent successful irradiations confirm that the sources of failures were identified correctly, and the implemented mitigations were adequate.

BR2↗

Inverted, Organic WORM Device Based on PEDOT:PSS with Very Low Turn-On Voltage

An organic Write-Once-Read-Many (WORM) device based on poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) as the active layer was fabricated with an inverted architecture. Insertion of an ultrathin layer of poly(methylmethacrylate) (PMMA) between the bottom electrode and the PEDOT:PSS resulted in a systematic and substantial decrease in turn-on voltage, from 7.0 V to less than 1.0 V. An optimal thickness of the PMMA layer was found to yield the lowest consistent turn-on voltage of ~0.8 V, with 0.5 V being the lowest value of all fabricated devices. The switching mechanism was attributed to filamentary doping of the PEDOT:PSS. Insertion of the PMMA acted to protect the underlying ZnO from being etched by the acidic PEDOT:PSS as well as to improve its wetting properties. Moreover, devices were demonstrated on both ITO and aluminum bottom electrodes, with aluminum yielding the highest ON/OFF ratios in the study. Owing to their inverted architecture, the devices demonstrated good stability, and the retention time of the ON-state was determined to be greater than twenty months while stored in air for devices with ITO bottom electrodes. Blade-coating was demonstrated as a viable processing technique for applications requiring rapid or large-area manufacturing in addition to deposition via spin-coating.

14 SOLAR ENERGY↗

A data analytical approach for assessing the efficacy of Operational Technology active defenses against insider threats

In recent years, the need for Operational Technology (OT) defenses has been recognized, serving as an additional line of defense when Information Technology (IT) defenses are bypassed. This is no longer considered an uncommon possibility when dealing with advanced persistent threat (APT) actors expected to be state-sponsored and receiving insider assistance. In these extreme adversarial situations, OT defenses aim to provide another layer of defense for the system, introduced directly at the physical process level, as described by the sensors data, the system model, and control actions. Just like IT defenses, two schools of thought, i.e., passive and active defenses, have emerged to address this challenge. In active defenses, representing the focus of this paper, known signatures, synthesized based on the system's unique characteristics, are inserted into the system. In contradistinction, passive methods rely solely on observing system behavior in search of patterns of normal behavior with deviations thereof representing abnormal behavior. In their most sophisticated implementations, both passive and active defenses rely on the use of data analytics to identify the patterns and synthesize the observed and/or inserted signatures. Past research has shown that passive defenses may be bypassed by APT actors relying on data analytics and their intimate knowledge of the system to evade detection by respecting the patterns identified by the defenders. Here this manuscript explores the use of active defenses under the assumption that the attacker has privileged access to the system, including access to the system's model and sensors data. Specifically, this manuscript assesses the ability of active defenses to remain invisible to the attackers, and discusses the associated challenges that must be addressed to ensure their resiliency against APT actors.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A GPU-based Approach for Path Planning Optimization via Travel Length Reduction

Typically, before constructing an object with an additive manufacturing system, the 3D object must be sent through a process called slicing. Slicing converts a 3D object commonly in the form of an STL file into a set of layers by horizontally intersecting a plane with the object at various heights. At each height, called a layer, multiple 2D polygons can be generated. Each polygon represents a boundary for solid geometry and is called an island. Each island is then comprised of multiple path types in an attempt to optimally fill the polygon. To move between each island and each islands’ paths, travels are inserted. Travels are simply motion by the system to move from one area of construction to another. Travels do not contribute to the construction of the object, and so, are considered wasted motion. In large-scale additive manufacturing, objects can be quite large and the distance between islands can be large as well. As a result, these travels can waste a significant amount of time. Ideally, travels would be as short as possible, however, computing global minimal travel paths is computationally expensive. To combat this problem, researchers at Oak Ridge National Lab developed a GPU-based approach to travel insertion based on a unique factoradic representation. This representation was then utilized by the GPU to solve the Traveling Salesman Problem (TSP). This algorithm was able to compute global minimal travel paths quickly resulting in faster object construction. A general investigation was also carried out to determine when a GPU vs CPU implementation would be beneficial.

Borish, Michael↗

Investigating the effect of aluminum oxide fixed charge on Schottky barrier height in molybdenum oxide-based selective contacts

A tunneling atomic layer deposited (ALD) AlO x layer was inserted in a Si|SiO x |AlO x |MoO x |metal tunnel diode structure to investigate the impact of fixed interface charge on Schottky barrier height. ALD AlO x provides a synthesis-tunable fixed charge and can provide excellent field effect passivation at the SiO x |AlO x interface. A large (>1 × 10 12 q.cm –2 ) negative fixed charge density was expected to decrease Schottky barrier height on p-type silicon and increase Schottky barrier height on n-type silicon by up to 0.4 eV based on an electrostatic model. Fixed charge density and interface trap state density were measured using a thick layer of AlO x in metal oxide semiconductor capacitor structures (MOSCAPs); Schottky barrier height and specific contact resistivity were measured using a tunneling-active layer of AlO x in contacted structures with MoO x . In some samples, HfO x interface layers were inserted between AlO x and silicon to quench the fixed negative charge. The Schottky barrier height was found to vary with processing conditions but did not have a strong correlation with expected fixed charge density. Here, while fixed charge may play a role in determining the Schottky barrier height, other parameters also have significant affect. Further work is needed to minimize contact resistivity and elucidate other factors impacting the Schottky barrier height.

14 SOLAR ENERGY↗

Association of lipoarabinomannan with high density lipoprotein in blood: Implications for diagnostics

Understanding the pathophysiology of tuberculosis, and the bio-distribution of pathogen-associated molecules in the host is essential for the development of efficient methods of intervention. One of the key virulence factors in the pathology of tuberculosis infection is Lipoarabinomannan (LAM). Previously, we have demonstrated the reliable detection of LAM in urine from tuberculosis patients in a sandwich immunoassay format. We also applied an ultra-sensitive detection strategy developed for amphiphilic biomarkers, membrane insertion, to the detection of LAM with a limit of detection of 10 fM. Herein, we evaluate the application of membrane insertion to the detection of LAM in patient serum, and demonstrate that the circulating concentrations of ‘monomeric’ LAM in serum are very low, despite significantly higher concentrations in the urine. Using spiked samples, we demonstrate that this discrepancy is due to the association of LAM with high-density lipoprotein (HDL) nanodiscs in human serum. Indeed, pull-down of HDL nanodiscs from human serum allows for the recovery of HDL-associated LAM. These studies suggest that LAM is likely associated with carrier molecules such as HDL in the blood of patients infected with tuberculosis. Furthermore, this phenomenon may not be limited to LAM in that many pathogen-associated molecular patterns like LAM are amphiphilic in nature and may also be associated with host lipid carriers. Such interactions are likely to affect host–pathogen interactions, pathogen bio-distribution and clearance in the host, and must be thoroughly understood for the effective design of vaccines and diagnostics.

59 BASIC BIOLOGICAL SCIENCES↗

Versatility of the adenovirus-vectored foot-and-mouth disease vaccine platform across multiple foot-and-mouth disease virus serotypes and topotypes using a vaccine dose representative of the AdtA24 conditionally licensed vaccine

We investigated the serotype- and topotype versatility of a replication-deficient human adenovirus serotype 5 vectored foot-and-mouth disease (FMD) vaccine platform (AdtFMD). Sixteen AdtFMD recombinant subunit monovalent vaccines targeting twelve distinct FMD virus (FMDV) serotype/topotypes in FMD Regional Pools I-VII were constructed. The AdtA24 serotype conditionally licensed vaccine served as the basis for vaccine design and target dose for cattle clinical trials. Several vaccines contained an additional RGD motif genetic insertion in the adenovector fiber knob, and/or a full-length 2B gene insertion in the FMDV P1 gene cassette. In 13 of the 22 efficacy studies conducted, naïve control and AdtFMD vaccinated cattle were challenged intradermolingually at 2 weeks post-vaccination using a FMDV strain homologous to the AdtFMD vaccine strain. Each of the 16 AdtFMD vaccines were immunogenic based on the presence of homologous neutralizing antibodies in the serum of approximately 90% of total vaccinates (n = 375) on the day of challenge. Importantly, for 75% of vaccines tested, the effective dose that conferred 100% protection against clinical FMD was identical to or in some cases lower than, the minimum protective dose for the conditionally licensed AdtA24 vaccine formulated with ENABL® adjuvant. Results also confirmed the capability of the AdtFMD vaccine platform to differentiate infected from vaccinated animals (DIVA) across the five FMDV serotypes evaluated. Collectively, this comprehensive set of FMD cattle vaccine dose ranging studies highlights the serotype- and topotype versatility of the AdtFMD vaccine platform for further development, licensure, and application in FMD outbreak control and disease eradication efforts.

59 BASIC BIOLOGICAL SCIENCES↗