Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Optical and x-ray characterization of the Daedalus ultrafast x-ray imager

The Daedalus ultrafast x-ray imager is the latest generation in Sandia’s hybrid CMOS detector family. With three frames along an identical line of sight, 1 ns minimum integration time, a higher full well than Icarus, and added features, Daedalus brings exciting new capabilities to diagnostic applications in inertial confinement fusion and high energy density science. In this work, we present measurements of time response, dynamic range, spatial uniformity, pixel cross-talk, and absolute x-ray sensitivity using pulsed optical and x-ray sources. Here, we report a measured 1.5 Me — full well, pixel sensitivity at 9.58 × 10 —7 V/e — , and an estimate of spatial uniformity at ~5% across the sensor array.

47 OTHER INSTRUMENTATION↗

X-ray imaging methods for high-energy density physics applications

Large scale high-energy density science facilities continue to grow in scale and complexity worldwide. The increase in driver capabilities, including pulsed-power and lasers, continue to push the boundaries of temperature, pressure, and densities, opening up new physics regimes. X-ray imaging is one of the many diagnostic techniques that are used to probe states of matter in these extreme conditions. Improved fabrication and polishing methods have provided improved x-ray microscope performance, while improving detector and x-ray sources now enable pico-second imaging with few micron resolutions. Here this Review will cover x-ray imaging methods, primarily absorption imaging, and their improvements over the last few decades.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of radiometric properties of LANDSAT-4 MSS

Two full frames of radiometrically corrected (Type A) LANDSAT-4 MSS data were analyzed digitally and visually for evidence of residual calibration differences between detectors, quantization effects, and other sensor-related artifacts. Both standard statistical and Fourier analysis techniques were employed. Opportunities for coincident coverage by LANDSATS 3 and 4 were identified in the contiguous 48 states. Paired acquisitions for two scenes were obtained and analyzed to establish relationships between signal values from common areas imaged by the two MSS Systems. Initial findings on detector-to-detector differences, coherent noise, and LANDSAT 4 to LANDSAT 3 calibration are summarized. Results show that LANDSAT 4 MSS produces data of generally good quality with dynamic ranges and target responses similar to those of previous sensors.

Rice, D. P.↗

Nancy Grace Roman Space Telescope Observatory Implementation and Challenges

NASA’s Nancy Grace Roman Space Telescope (Roman), previously referred to as Wide Field Infrared Survey Telescope (WFIRST), was named after Dr. Nancy Grace Roman, an astronomer and NASA pioneer of modern space-based astronomy who is known as the “mother of the Hubble Space Telescope”. Roman is a deep space infrared observatory with a Hubble-sized telescope and wide field of view instrument (greater than 100 times that of Hubble’s) that will conduct a high latitude time-domain survey, a high latitude imaging and spectroscopic survey, and a galactic bulge time-domain survey to characterize dark energy and expand the census of exoplanets in our galaxy while allowing a broad range of astrophysics research. Roman will also demonstrate exoplanet coronagraphy with active wave front control technology and provide general investigator programs for the science community. Roman is finishing the critical design phase and is planning for launch in 2026. It will operate in a quasi-halo orbit about Sun-Earth L2, 1.5 million kilometers from Earth, for a five-year primary mission life. The Observatory features an Optical Telescope Assembly with an existing, repurposed 2.4m primary mirror, a Wide Field Instrument with a focal plane array comprised of 18 HgCdTe near-infrared detectors and a grism, prism and filter elements for imaging and spectroscopy in support of the primary surveys, as well as a Coronagraph instrument technology demonstration with starlight suppression technology for direct imaging and spectroscopy of exoplanets. The telescope is mounted to the Instrument Carrier composite truss structure which also optically meters each instrument, includes a Launch Load and Vibration Isolation System to provide passive isolation of spacecraft jitter sources while also supporting the payload during launch and is attached to the Spacecraft Bus. The Spacecraft also includes a Solar Array Sunshield ,Deployable Aperture Cover, Lower Instrument Sunshade, High Gain Antenna System, and Outer Barrel Assembly. Figure 1 shows an overview of the Roman Observatory. When fully integrated, Roman will be the largest Observatory assembled and tested at NASA’s Goddard Space Flight Center. Figure 1. Roman Observatory Overview Development of scientific satellites is challenging by nature, as the pursuit to broaden scientific knowledge always pushes the boundary of what has come before. The implementation of the Roman mission is a prime example and expected challenges have been augmented by the foundational decision to use the existing telescope components, developed in the early 2000s by another Government agency for a different application. Other unique aspects of the Roman mission, such as its survey nature, the vast amount of data required to meet science objectives, and packaging of the Observatory elements around the existing telescope components, create constrained design spaces that drive competing requirements across Observatory subsystems. Given these challenges, systems engineering has been a critical discipline in balancing implementation decisions for the Roman mission and will continue to play a key role going forward. This paper will discuss details of the Roman Observatory configuration, as well as some of the systems engineering challenges and the decision-making process used to mature the Roman Space Telescope preliminary design to implementation.

Lisa Ml Bartusek↗

Prelaunch Spectral Characterization of the Operational Land Imager-2

The Landsat-9 satellite, launched in September 2021, carries the Operational Land Imager-2 (OLI-2) as one of its payloads. This instrument is a clone of the Landsat-8 OLI and its mission is to continue the operational land imaging of the Landsat program. The OLI-2 instrument is not significantly different from OLI though the instrument-level pre-launch spectral characterization process was much improved. The focal plane modules used on OLI-2 were manufactured as spares for OLI and much of the spectral characterization of the components was performed for OLI. However, while the spectral response of the fully assembled OLI was characterized by a double monochromator system, the OLI-2 spectral characterization made use of the Goddard Laser for Absolute Measurement of Radiance (GLAMR). GLAMR is a system of tunable lasers that cover 350–2500 nm which are fiber-coupled to a 30 in integrating sphere permanently monitored by NIST-traceable radiometers. GLAMR allowed the spectral characterization of every detector of the OLI-2 focal plane in nominal imaging conditions. The spectral performance of the OLI-2 was, in general, much better than requirements. The final relative spectral responses (RSRs) represent the best characterization any Landsat instrument spectral response. This paper will cover the results of the spectral characterization from the component-level to the instrument-level of the Landsat-9 OLI-2.

Landsat-9↗

Progress towards high-performance thermopile imaging arrays

The purpose of this present work is to improve thermopile 2-D arrays substantially by combining Bi-Te and Bi-Sb-Te thermoelectric materials with a unique pixel structure and low-noise readout circuitry.

detector thermopile infrared uncooled array imagin↗

Gallium arsenide quantum well-based far infrared array radiometric imager

We have built an array-based camera (FIRARI) for thermal imaging (lambda = 8 to 12 microns). FIRARI uses a square format 128 by 128 element array of aluminum gallium arsenide quantum well detectors that are indium bump bonded to a high capacity silicon multiplexer. The quantum well detectors offer good responsivity along with high response and noise uniformity, resulting in excellent thermal images without compensation for variation in pixel response. A noise equivalent temperature difference of 0.02 K at a scene temperature of 290 K was achieved with the array operating at 60 K. FIRARI demonstrated that AlGaAS quantum well detector technology can provide large format arrays with performance superior to mercury cadmium telluride at far less cost.

Forrest, Kathrine A.↗

Advances in CdZnTeSe for Radiation Detector Applications

Detection of X- and gamma-rays is essential to a wide range of applications from medical imaging to high energy physics, astronomy, and homeland security. Cadmium zinc telluride (CZT) is the most widely used material for room-temperature detector applications and has been fulfilling the requirements for growing detection demands over the last three decades. However, CZT still suffers from the presence of a high density of performance-limiting defects, such as sub-grain boundary networks and Te inclusions. Cadmium zinc telluride selenide (CZTS) is an emerging material with compelling properties that mitigate some of the long-standing issues seen in CZT. This new quaternary is free from sub-grain boundary networks and possesses very few Te inclusions. In addition, the material offers a high degree of compositional homogeneity. The advancement of CZTS has accelerated through investigations of the material properties and virtual Frisch-grid (VFG) detector performance. The excellent material quality with highly reduced performance-limiting defects elevates the importance of CZTS as a potential replacement to CZT at a substantially lower cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A motion detection system for AXAF X-ray ground testing

The concept, implementation, and performance of the motion detection system (MDS) designed as a diagnostic for X-ray ground testing for AXAF are described. The purpose of the MDS is to measure the magnitude of a relative rigid body motion among the AXAF test optic, the X-ray source, and X-ray focal plane detector. The MDS consists of a point source, lens, centroid detector, transimpedance amplifier, and computer system. Measurement of the centroid position of the image of the optical point source provides a direct measure of the motions of the X-ray optical system. The outputs from the detector and filter/amplifier are digitized and processed using the calibration with a 50 Hz bandwidth to give the centroid's location on the detector. Resolution of 0.008 arcsec has been achieved by this system. Data illustrating the performance of the motion detection system are also presented.

Arenberg, Jonathan W.↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

Very-large-format pulse-counting UV detectors

Multi-anode microchannel array (MAMA) detector systems with formats of 2048 x 2048 pixels and pixel dimensions of 25 x 25 microns are being developed for use in the NASA Goddard Hubble Space Telescope Imaging Spectrograph. This paper describes the current state of development of these detector systems.

Timothy, J. Gethyn↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimodal characterization of Te inclusions in Cd 1−x Zn x Te and Cd 1−x Zn x Te 1−y Se y for gamma and X-ray detectors

While CdZnTe (CZT) and CdZnTeSe (CZTS) semiconductors have emerged as compounds for room-temperature gamma and X-ray detection materials, they continue to be constrained by the formation of Te-inclusion defects generated during the growth and post-growth phases of the material, which adversely affect the detector performance. We demonstrate the utility of multimodal microscopic imaging and analysis for the characterization of the optical and electronic properties of Te inclusions in CZT and CZTS crystals at both micron and nanometer length scales. Having first identified regions with micron-scale Te inclusions using confocal Raman microscopy techniques, optically coupled infrared scattering near-field optical microscopic mapping was performed to map the distribution of these inclusions with nanometer spatial resolution and correlate the presence of Te inclusions in the matrix with other properties. Kelvin probe force microscopy was then utilized to characterize the variations of the work function associated with the presence of Te inclusions. Here, we observe an increase of ~ 240 mV in the work function associated with Te inclusions compared to the bulk CZT/CZTS crystals. Additionally, we observe that individual bulk grains in CZT can exhibit slight potential variations. Our findings develop a portrait of the charge trapping mechanisms in CZT and CZTS that act to degrade detector performance, while the demonstration of these combined microscopy techniques provides a new analytical tool that can be utilized for further optimization of the detector performance for these semiconducting compounds.

36 MATERIALS SCIENCE↗

In-flight Performance of the Detectors on HST/Wide Field Camera 3

Wide Field Camera 3 (WFC3) is a powerful new imager recently installed on the Hubble Space Telescope during Servicing Mission 4. WFC3 covers wavelengths from the near UV (200nm) to the near infrared (out to 1.7microns), in two channels. The UV/visible (UVIS) channel utilizes two low-noise, UV-enhanced 2Kx4K CCD detectors from e2v, while the IR channel incorporates a 1Kx1K 1.7micron cutoff HgCdTe array, custom-developed for the WFC3 program by Teledyne. We report here on the performance of the detectors in-flight as observed in this summer's Servicing Mission Orbital Verification program.

Kimble, Randy↗

3D Source Reconstruction Using Coded Aperture Gamma-Ray Imaging

Recent measurements with coded-aperture imagers demonstrate material mass determination in a holdup setting to an accuracy within a few percent. This capability is of particular interest to the Surplus Plutonium Disposition (SPD) project, which aims to dilute and dispose of surplus plutonium oxide. Gamma-ray imagers can be used to determine holdup without interrupting normal operations. In this work, we examine techniques for 3D source localization and mass determination using gamma-ray imagers. Coded-aperture imagers provide excellent source localization within the 2D image plane; however, multiple imagers operating in tandem are necessary to identify source location in 3D space. A Maximum Likelihood Expectation-Maximization (MLEM) method for fitting detector mappings is a powerful tool for accomplishing this task. MLEM allows 3D source localization to be simultaneously constrained using multiple gamma-ray imagers by constructing the basis for the MLEM fit using detector mappings from different detector locations stitched together. Each of these basis points represents a singular response from a source in 3D space and is generated using Monte Carlo simulations of sources placed individually at different locations throughout the imager’s field of view. Additionally, implementing knowledge of the physical equipment in the simulations of the glovebox used for the SPD project incorporates attenuation effects that are needed to calculate material holdup.

Laminack, Alex↗

A new AM Her-like X-ray source

The discovery of a new X ray source associated with a binary and classifiable as a member of the AM Her class of objects is reported. The object was located with a detector on the HEAO A-2 spacecraft and by the imaging proportional counter on the Einstein Observatory. Detection occurred in the 0.15-0.4 keV band, and intensity variations of a factor of 2 were observed to happen on a time scale of around 2 hr. A location error box 0.9 deg on a side was constructed from the 2.95 deg overlapping FWHM field of view of the HEAO detector. The object, designated HO139-68, was reexamined using photometric and spectroscopic scans of it and the companion, which has been observed to be an ordinary late type star. Evidence for the presence of a magnetic white dwarf in the binary is discussed, noting indications of cyclotron emission. The X ray source flux is estimated to be 2.3/10 billion erg per sq cm per sec.

Agrawal, P. C.↗