The Forensic Examination and Interpretation of Tool Marks
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Whiting events—the episodic precipitation of fine-grained suspended calcium carbonates in the water column—have been documented across a variety of marine and lacustrine environments. Whitings likely are a major source of carbonate muds, a constituent of limestones, and important archives for geochemical proxies of Earth history. While several biological and physical mechanisms have been proposed to explain the onset of these precipitation events, no consensus has been reached thus far. Fayetteville Green Lake (New York, USA) is a meromictic lake that experiences annual whitings. Materials suspended in the water column collected through the whiting season were characterized using scanning electron microscopy and scanning transmission X-ray microscopy. Whitings in Fayetteville Green Lake are initiated in the spring within the top few meters of the water column, by precipitation of fine amorphous calcium carbonate (ACC) phases nucleating on microbial cells, as well as on abundant extracellular polymeric substances (EPS) frequently associated with centric diatoms. Whiting particles found in the summer consist of 5–7 μm calcite grains forming aggregates with diatoms and EPS. Simple calculations demonstrate that calcite particles continuously grow over several days, then sink quickly through the water column. In the late summer, partial calcium carbonate dissolution is observed deeper in the water column. Settling whiting particles, however, reach the bottom of the lake, where they form a major constituent of the sediment, along with diatom frustules. The role of diatoms and associated EPS acting as nucleation surfaces for calcium carbonates is described for the first time here as a potential mechanism participating in whitings at Fayetteville Green Lake. This mechanism may have been largely overlooked in other whiting events in modern and ancient environments.
The chemical-structural properties of synthetic calcium silicate hydrate (C-S-H) with C/S (Ca/Si) ratios of 0.75, 1 and 1.33 were studied after gamma irradiation-absorbed doses ranging from 0.145 to 0.784 MGy and compared with those of control specimens. The results showed that the total water content given by thermogravimetric analysis and the dimension of the basal spacing given by x-ray diffraction were comparable for control and irradiated samples, which indicate that the interlayer water content did not change. The morphology, C/S ratios, and silicate mean chain length were also found to be unaltered by the absorbed gamma doses.
This study shows the effects of nuclear waste glass production on Monofrax K-3 refractory corrosion. A continuously fed research-scale melter containing an Fe- and Ni-rich simulated nuclear waste feed with borosilicate glass-forming chemicals was cyclically melted at 1150°C and idled at 1050°C for a total of 11 weeks. Chemical maps using scanning electron microscopy show the interactions between the quenched melt and the refractory. Nanoscale X-ray-computed tomography was used for a three-dimensional visualization of certain parts of the interface. Unreacted K-3 consists of primarily corundum (Al,Cr) 2 O 3 and spinel (Fe 2+ ,Mg)(Al,Cr) 2 O 4 interlocking crystalline phases. Some of the Cr from the refractory interacts with the Ni and Fe from the melt to form a reaction layer comprising (Ni,Fe 2+ )(Cr,Fe 3+ ) 2 O 4 spinel crystals. Simultaneously, melt components (Na,Si) infiltrate into the refractory. This interaction proceeds at the expense of the integrity of the refractory structure. Intact refractory grains (e.g., (Al,Cr) 2 O 3 ) as well as the reaction layer itself can lose mechanical integrity and spall off into the melt, especially near the top of the melter. As the reaction layer can be a protective boundary for the refractory against further melt infiltration, a reduction in the reaction layer thickness allows an increase in refractory corrosion.
Abstract not provided
Silver nanoparticles of many types are widely used in consumer and medical products. The surface chemistry of particles and the coatings that form during synthesis or use in many types of media can significantly impact the behaviors of particles including dissolution, transformation and biological or environmental impact. Consequently it is useful to be able to extract information about the thickness of surface coatings and other attributes of nanoparticles produced in a variety of ways. It has been demonstrated that X-ray Photoelectron Spectroscopy (XPS) can be reliably used to determine the thickness of organic and other nanoparticles coatings and shells. However, care is required to produce reliable and consistent information. Here we report the XPS spectra from gold/silver core-shell nanoparticles of nominal size 20 nm removed from a citrate saturated solution after one and two washing cycles. The Simulation of Electron Spectra for Surface Analysis (SESSA) program had been used to model peak amplitudes to obtain information on citrate coatings that remain after washing and demonstrate the presence of the gold core. This data is provided so that others can compare use of SESSA or other modeling approaches to quantify the nature of coatings to those already published and to explore the impacts particle non-uniformities on XPS signals from core-shell nanoparticles.
Classical molecular dynamics (MD) simulations of plasma-surface interactions were performed of physical sputtering and reactive ion etching (RIE), with predictions based on several force fields. In this paper, we focus mainly on SiO 2 but include some results for Si substrates as well. Here, we compare predictions from these MD simulations to experimental studies of SiO 2 physical sputtering (by Ar + ions), RIE of Si, and RIE of SiO 2 (both using F atoms and Ar + ions). MD results using different published force fields are compared to reported yields from published vacuum beam experiments. The near-surface depth profiles predicted using different force fields are compared. One motivation for the present study is to document the nature and magnitude of differences in the predictions for selected systems and conditions of practical interest.
The optical transmittance of encapsulation materials is a key characteristic for their use in photovoltaic (PV) modules. Changes in transmittance with time in the field affect module performance, which may impact product warranties. Transmittance is important in product development, module manufacturing, and field power production (both immediate and long-term). Therefore, an international standard (IEC 62788-1-4) has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the optical performance of PV encapsulation materials. Existing standards, such as ASTM E903, are general and more appropriately applied to concentrated solar power than to PV. Starting from the optical transmittance measurement, the solar-weighted transmittance of photon irradiance, yellowness index (which may be used in aging studies to assess durability), and ultraviolet (UV) cut-off wavelength may all be determined using the proposed standard. The details of the proposed test are described. The results of a round-robin experiment (for five materials) conducted at seven laboratories to validate the test procedure using representative materials are also presented. For example, the Encapsulation Group actively explored the measurement requirements (wavelength range and resolution), the requirements for the spectrophotometer (including the integrating sphere and instrument accessories, such as a depolarizer), specimen requirements (choice of glass-superstrate and -substrate), and data analysis (relative to the light that may be used in the PV application). The round-robin experiment identified both intra- and inter-laboratory instrument precision and bias for five encapsulation materials (encompassing a range of transmittance and haze-formation characteristics).
Due to the complicated technical nature of gated radiation therapy, electronic and mechanical limitations may affect the precision of delivery. The purpose of this study is to investigate the geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation treatments (SS-IMRT). Unique segmental MLC plans are designed, which allow quantitative testing of the gating process. Both ungated and gated deliveries are investigated for different dose sizes, dose rates, and gating window times using a commercial treatment system (Varian Trilogy) together with a respiratory gating system [Varian Real-Time Position Management system]. Radiographic film measurements are used to study the geometric accuracy, where it is found that with both ungated and gated SS-IMRT deliveries the MLC leaf divergence away from planned is less than or equal to the MLC specified leaf tolerance value for all leafs (leaf tolerance being settable from 0.5-5 mm). Nevertheless, due to the MLC controller design, failure to define a specific leaf tolerance value suitable to the SS-IMRT plan can lead to undesired geometric effects, such as leaf motion of up to the maximum 5 mm leaf tolerance value occurring after the beam is turned on. In this case, gating may be advantageous over the ungated case, as it allows more time for the MLC to reach the intended leaf configuration. The dosimetric precision of gated SS-IMRT is investigated using ionization chamber methods. Compared with the ungated case, it is found that gating generally leads to increased dosimetric errors due to the interruption of the 'overshoot phenomena.' With gating the average timing deviation for intermediate segments is found to be 27 ms, compared to 18 ms for the ungated case. For a plan delivered at 600 MU/min this would correspond to an average segment dose error of {approx}0.27 MU and {approx}0.18 MU for gated and ungated deliveries, respectively. The maximum dosimetric errors for individual intermediate segments are found to deviate by up to {approx}0.64 MU from their planned value when delivered at 600 MU/min using gating, this compares to only {approx}0.32 MU for the ungated case.
Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a significant radiation detriment. Knowledge of the radiation dose is therefore necessary to justify the exposures. To calculate doses in the entire body and in specific organs, computational models of the human anatomy are needed. Using medical imaging techniques, voxel phantoms have been developed to achieve a representation as close as possible to the anatomical properties. In this study two voxel phantoms, representing prematurely born babies, were created from computed tomography- and magnetic resonance images: Phantom 1 (1910 g) and Phantom 2 (590 g). The two voxel phantoms were used in Monte Carlo calculations (MCNPX) to assess organ doses. The results were compared with the commercially available software package PCXMC in which the available mathematical phantoms can be downsized toward the prematurely born baby. The simple phantom-scaling method used in PCXMC seems to be sufficient to calculate doses for organs within the radiation field. However, one should be careful in specifying the irradiation geometry. Doses in organs that are wholly or partially outside the primary radiation field depend critically on the irradiation conditions and the phantom model.
The aim of this study was to assess the potential of a modern x,y,z modulation-based automatic exposure control system (AEC) for dose reduction in pediatric and adult multidetector CT (MDCT) imaging and evaluate the quality of the images obtained. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-, 5-, 10-year old child, and adult were scanned with a MDCT scanner, equipped with a modern AEC system. Dose reduction (%DR) was calculated as the percentage difference of the mean modulated and the preset tube current-time product that is prescribed for standard head and body scan protocols. The effect of the tube potential and the orientation of the topogram acquisition on dose reduction were assessed. Image quality was evaluated on the basis of image noise and signal to noise ratio (SNR). The dose reduction values achieved in pediatric phantoms were remarkably lower than those achieved for the adult. The efficiency of the AEC is decreased at 80 kVp compared to higher tube potentials and for helical scans following an anterior posterior (AP-AEC) compared to a lateral (LAT-AEC) topogram acquisition. In AP-AEC scans, the dose reduction ranged between 4.7 and 34.7% for neonate, 15.4 and 30.9% for 1 year old, 3.1 and 26.7% for 5 years old, 1.2 and 58.7% for 10 years old, and 15.5 and 57.4% for adult. In LAT-AEC scans, the corresponding dose reduction ranged between 11.0 and 36.5%, 27.2 and 35.7%, 11.3 and 35.6%, 0.3 and 67.0%, and 15.0 and 61.7%, respectively. AP-AEC scans resulted in a 17.1% and 19.7% dose increase in the thorax of neonate and the pelvis of the 10-year old phantom, respectively. The variation in the measured noise among images obtained along the scanning z axis was lower in AEC activated compared to fixed milliamperes scans. However, image noise was significantly increased (P<.001) and SNR significantly decreased (P<.001) in most AEC activated compared to fixed milliamperes scans. In conclusion, AEC resulted in a (i) substantial dose reduction, which is less pronounced in children compared to adult, (ii) higher dose reduction in scans following a lateral compared to scans following an anterior-posterior topogram acquisition, (iii) increase of image noise and degradation of SNR in the obtained images compared to the fixed milliamperes technique.
Purpose: It is challenging to reproducibly measure and compare cancer lesions on numerous follow-up studies; the process is time-consuming and error-prone. In this paper, we show a method to automatically and reproducibly identify and segment abnormal lymph nodes in serial computed tomography (CT) exams. Methods: Our method leverages initial identification of enlarged (abnormal) lymph nodes in the baseline scan. We then identify an approximate region for the node in the follow-up scans using nonrigid image registration. The baseline scan is also used to locate regions of normal, non-nodal tissue surrounding the lymph node and to map them onto the follow-up scans, in order to reduce the search space to locate the lymph node on the follow-up scans. Adaptive region-growing and clustering algorithms are then used to obtain the final contours for segmentation. We applied our method to 24 distinct enlarged lymph nodes at multiple time points from 14 patients. The scan at the earlier time point was used as the baseline scan to be used in evaluating the follow-up scan, resulting in 70 total test cases (e.g., a series of scans obtained at 4 time points results in 3 test cases). For each of the 70 cases, a ''reference standard'' was obtained by manual segmentation by a radiologist. Assessment according to response evaluation criteria in solid tumors (RECIST) using our method agreed with RECIST assessments made using the reference standard segmentations in all test cases, and by calculating node overlap ratio and Hausdorff distance between the computer and radiologist-generated contours. Results: Compared to the reference standard, our method made the correct RECIST assessment for all 70 cases. The average overlap ratio was 80.7 {+-} 9.7% s.d., and the average Hausdorff distance was 3.2 {+-} 1.8 mm s.d. The concordance correlation between automated and manual segmentations was 0.978 (95% confidence interval 0.962, 0.984). The 100% agreement in our sample between our method and the standard with regard to RECIST classification suggests that the true disagreement rate is no more than 6%. Conclusions: Our automated lymph node segmentation method achieves excellent overall segmentation performance and provides equivalent RECIST assessment. It potentially will be useful to streamline and improve cancer lesion measurement and tracking and to improve assessment of cancer treatment response.
Purpose: This study was undertaken to optimize the measurement techniques with radiochromic EBT3 films to offer accurate surface dose measurements and at the same time high resolution depth dose curves of the backscattering from high Z materials. Methods: Radiochromic EBT3 films (Ashland ISP, Wayne, USA) were wrapped around a PET hollow cylinder with a diameter of 41.5 mm and fixed upon the surface of a lead block. The setup was immersed in water and exposed to a dose of 2 Gy at 6MV acceleration voltage using a Siemens Primus linear accelerator. Water reference measurements were undertaken under equal conditions. An Epson Expression 10000 XL flatbed scanner (Epson, Suwa, Japan) with a preset resolution of 72 dpi was used for digitization. Results: The dose enhancement could be measured with a high resolution of measurement points along the axis normal to the lead surface. A dose enhancement of 70 % was measured at a distance of 134 μm from the lead surface. The data has been compared with results presented by Das et al (Med. Phys. 16(3) (1989)) and is consistent within the uncertainty of the measurements. The results are in consistence with the results from time-tested EBT3 setups, i.e. normal-to-beam EBT3 film stacks and parallel to beam EBT3-films. Conclusion: The cylindrical film setup offers a powerful tool for surface measurements. The advantages of a stacked film setup and a parallel to beam setup could be combined.
Purpose: There are unique obstacles to implementing the MatriXX ionchamber array as a QA tool in Brachytherapy given that the device is designed for use in the MV energy range. One of the challenges we investigate is the affect of acquisition rates on dose measurement accuracy for HDR treatment plans. Methods: A treatment plan was optimized in Oncentra Brachy TPS to deliver a planar dose to a 5×5cm region at 10mm depth. The applicator was affixed to the surface of the MatriXX array. The plan was delivered multiple times using a Nucleatron HDR afterloader with a 2.9Ci Ir192 source. For each measurement the sampling rate of the MatriXX movie mode was varied (30ms and 500ms). This experiment was repeated with identical parameters, following a source exchange, with an 11.2Ci Ir192 source. Finally, a single snap measurement was acquired. Analysis was preformed to evaluate the fidelity of the dose delivery for each iteration of the experiment. Evaluation was based on the comparison between the measured and TPS predicted dose. Results: Higher sample rates induce a greater discrepancy between the predicted and measured dose. Delivering the plan using a lower activity source also produced greater discrepancy in the measurement due to the increased delivery time. Analyzing the single snap measurement showed little difference from the 500ms integral dose measurement. Conclusion: The advantage of using movie mode for HDR treatment delivery QA is the ability for real time source tracking in addition to dose measurement. Our analysis indicates that 500ms is an optimal frame rate.
Purpose: To analyze the most recent results of IROC Houston’s anthropomorphic H&N phantom to determine the nature of failing irradiations and the feasibility of altering pass/fail credentialing criteria. Methods: IROC Houston’s H&N phantom, used for IMRT credentialing for NCI-sponsored clinical trials, requires that an institution’s treatment plan must agree with measurement within 7% (TLD doses) and ≥85% pixels must pass 7%/4 mm gamma analysis. 156 phantom irradiations (November 2014 – October 2015) were re-evaluated using tighter criteria: 1) 5% TLD and 5%/4 mm, 2) 5% TLD and 5%/3 mm, 3) 4% TLD and 4%/4 mm, and 4) 3% TLD and 3%/3 mm. Failure/poor performance rates were evaluated with respect to individual film and TLD performance by location in the phantom. Overall poor phantom results were characterized qualitatively as systematic (dosimetric) errors, setup errors/positional shifts, global but non-systematic errors, and errors affecting only a local region. Results: The pass rate for these phantoms using current criteria is 90%. Substituting criteria 1-4 reduces the overall pass rate to 77%, 70%, 63%, and 37%, respectively. Statistical analyses indicated the probability of noise-induced TLD failure at the 5% criterion was <0.5%. Using criteria 1, TLD results were most often the cause of failure (86% failed TLD while 61% failed film), with most failures identified in the primary PTV (77% cases). Other criteria posed similar results. Irradiations that failed from film only were overwhelmingly associated with phantom shifts/setup errors (≥80% cases). Results failing criteria 1 were primarily diagnosed as systematic: 58% of cases. 11% were setup/positioning errors, 8% were global non-systematic errors, and 22% were local errors. Conclusion: This study demonstrates that 5% TLD and 5%/4 mm gamma criteria may be both practically and theoretically achievable. Further work is necessary to diagnose and resolve dosimetric inaccuracy in these trials, particularly for systematic dose errors. This work is funded by NCI Grant CA180803.
Understanding the dynamics of circulating tumor cell (CTC) behavior within the vasculature has remained an elusive goal in cancer biology. To elucidate the contribution of hydrodynamics in determining sites of CTC vascular colonization, the physical forces affecting these cells must be evaluated in a highly controlled manner. To this end, we have bioprinted endothelialized vascular beds and perfused these constructs with metastatic mammary gland cells under physiological flow rates. By pairing these in vitro devices with an advanced computational flow model, we found that the bioprinted analog was readily capable of evaluating the accuracy and integrated complexity of a computational flow model, while also highlighting the discrete contribution of hydrodynamics in vascular colonization. This intersection of these two technologies, bioprinting and computational simulation, is a key demonstration in the establishment of an experimentation pipeline for the understanding of complex biophysical events.
CRISPR-based systems are emerging as the premier method to manipulate many cellular processes. In this study, a simple and efficient CRISPR interference (CRISPRi) system for targeted gene repression in archaea was developed. The Methanosarcina acetivorans CRISPR-Cas9 system was repurposed by replacing Cas9 with the catalytically dead Cas9 (dCas9) to generate a CRISPRi-dCas9 system for targeted gene repression. To test the utility of the system, genes involved in nitrogen (N2) fixation were targeted for dCas9-mediated repression. First, the nif operon (nifHI 1 I 2 DKEN) that encodes molybdenum nitrogenase was targeted by separate guide RNAs (gRNAs), one targeting the promoter and the other targeting nifD. Remarkably, growth of M. acetivorans with N 2 was abolished by dCas9-mediated repression of the nif operon with each gRNA. The abundance of nif transcripts was >90% reduced in both strains expressing the gRNAs, and NifD was not detected in cell lysate. Next, we targeted NifB, which is required for nitrogenase cofactor biogenesis. Expression of a gRNA targeting the coding sequence of NifB decreased nifB transcript abundance >85% and impaired but did not abolish growth of M. acetivorans with N2. Finally, to ascertain the ability to study gene regulation using CRISPRi-dCas9, nrpR1, encoding a subunit of the repressor of the nif operon, was targeted. The nrpR1 repression strain grew normally with N2 but had increased nif operon transcript abundance, consistent with NrpR1 acting as a repressor. Furthermore, these results highlight the utility of the system, whereby a single gRNA when expressed with dCas9 can block transcription of targeted genes and operons in M. acetivorans.