Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Response to “Comment on ‘Twin symmetry texture of energetically condensed niobium thin films on sapphire substrate’ ” [J. Appl. Phys. 112, 016101 (2012)]

Welander is correct about the misidentified crystal-directions in the top-view sapphire lattice (Fig. 4 [Zhao et al., J. Appl. Phys. 110, 033523 (2011)]). He is also correct about the misorientation of the pole figures in Fig. 4. In Fig. 1 of this response, we have corrected these errors. Perhaps because of these errors, Welander misconstrued our discussion of the Nbcrystal growth as claiming a new 3D registry. That was not our intention. Rather, we wished to highlight the role of energetic condensation that drives low-defect crystal growth by a combination of non-equilibrium sub-plantation that disturbs the substrate lattice and thermal annealing that annihilates defects and promotes large-grain crystal growth.

Zhao, X.↗

Correcting hot-wire measurements of stream-wise turbulence intensity in boundary layers

The current experimental activity aimed at resolving the scaling of stream-wise turbulence intensity profiles uu{sup +}(y{sup +}) with Reynolds number in turbulent flat plate boundary layers has brought the largely unresolved issue of correcting systematic errors in hot-wire measurements of uu{sup +}(y{sup +}) into focus. Here, a heuristic scheme is proposed to generate unique uu{sup +}(y{sup +};Re{sub {delta}{sup *}}) profiles from data obtained with single hot wires of widely different length, aspect ratio and construction over a large Reynolds number range of 4000 < or approx. Re{sub {delta}{sup *}} < or approx. 50 000. A comparison with LDA data and other checks suggest that the present correction scheme produces uu{sup +}(y{sup +};Re{sub {delta}{sup *}}) profiles close to the (unknown) true profiles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical Note: Contrast solution density and cross section errors in inhomogeneity-corrected dose calculation for breast balloon brachytherapy

Purpose: Recent recommendations by the American Association of Physicists in Medicine Task Group 186 emphasize the importance of understanding material properties and their effect on inhomogeneity-corrected dose calculation for brachytherapy. Radiographic contrast is normally injected into breast brachytherapy balloons. In this study, the authors independently estimate properties of contrast solution that were expected to be incorrectly specified in a commercial brachytherapy dose calculation algorithm. Methods: The mass density and atomic weight fractions of a clinical formulation of radiographic contrast solution were determined using manufacturers' data. The mass density was verified through measurement and compared with the density obtained by the treatment planning system's CT calibration. The atomic weight fractions were used to determine the photon interaction cross section of the contrast solution for a commercial high-dose-rate (HDR) brachytherapy source and compared with that of muscle. Results: The density of contrast solution was 10% less than that obtained from the CT calibration. The cross section of the contrast solution for the HDR source was 1.2% greater than that of muscle. Both errors could be addressed by overriding the density of the contrast solution in the treatment planning system. Conclusions: The authors estimate the error in mass density and cross section parameters used by a commercial brachytherapy dose calculation algorithm for radiographic contrast used in a clinical breast brachytherapy practice. This approach is adaptable to other clinics seeking to evaluate dose calculation errors and determine appropriate density override values if desired.

60 APPLIED LIFE SCIENCES↗

Modeling forest site productivity using mapped geospatial attributes within a South Carolina Landscape, USA

Spatially explicit mapping of forest productivity is important to assess many forest management alternatives. We assessed the relationship between mapped variables and site index of forests ranging from southern pine plantations to natural hardwoods on a 74,000-ha landscape in South Carolina, USA. Mapped features used in the analysis were soil association, land use condition in 1951, depth to groundwater, slope and aspect. Basal area, species composition, age and height were the tree variables measured. Linear modelling identified that plot basal area, depth to groundwater, soils association and the interactions between depth to groundwater and forest group, and between land use in 1951 and forest group were related to site index (SI) (R 2 =0.37), but this model had regression attenuation. We then used structural equation modeling to incorporate error-in-measurement corrections for basal area and groundwater to remove bias in the model. We validated this model using 89 independent observations and found the 95% confidence intervals for the slope and intercept of an observed vs. predicted site index error-corrected regression included zero and one, respectively, indicating a good fit. With error in measurement incorporated, only basal area, soil association, and the interaction between forest groups and land use were important predictors (R2 =0.57). Thus, we were able to develop an unbiased model of SI that could be applied to create a spatially explicit map based primarily on soils as modified by past (land use and forest type) and recent forest management (basal area).

54 ENVIRONMENTAL SCIENCES↗

NOR Flash Memory Scrubbing Application for Boot File Preservation of NASA’s Descent and Landing Computer (DLC)

Progress on NASA’s Safe and Precise Landing Integrated Capabilities Evolution (SPLICE) project continues, specifically with this development of the Descent and Landing Computer (DLC). One of the DLC’s primary contributions as a SPLICE technology is its implementation of algorithms and operation of sensors to autonomously guide a spacecraft in performing more precise and safer landings on celestial bodies such as the Moon and Mars [1]. The second iteration of the DLC is known as the Engineering Test Unit (ETU) and one of its desired functionalities is the ability to preserve the fidelity of the system’s boot file through the use of memory scrubbing [2]. The ETU has two primary boards, one for housing a Multi-Processor System on a Chip (MPSoC) and the other for housing a Xilinx Kintex Ultrascale FPGA*. To emulate a memory scrubbing function implemented on the ETU’s FPGA board, the design and testing of a software application was performed on a Xilinx KCU105 FPGA evaluation board. The memory scrubbing application had to meet certain key criteria such as (1) properly utilize with the flash memory’s Serial Peripheral Interface (SPI) to read, write, and erase flash memory properly, (2) be able to detect arbitrarily large or small amounts of bit-errors, (3) be able to correct all detected errors, and (4) perform memory scrubbing indefinitely and autonomously. A prototype implementation was constructed and tested, demonstrating successful detection and correction of bit errors in multiple configurations. In the form of burst errors or singular bit flips, and in amounts of errors ranging from one to fifteen (per 256 Bytes), the application was successful in preserving memory fidelity.

Flash memory↗

Corrected Article: 'An error-controlled fast multipole method' [J. Chem. Phys. 131, 244102 (2009)]

We present a two-stage error estimation scheme for the fast multipole method (FMM). This scheme can be applied to any particle system. It incorporates homogeneous as well as inhomogeneous distributions. The FMM error as a consequence of the finite representation of the multipole expansions and the operator error is correlated with an absolute or relative user-requested energy threshold. Such a reliable error control is the basis for making reliable simulations in computational physics. Our FMM program on the basis of the two-stage error estimation scheme is available on request.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PM4Stell: A prototype permanent magnet stellarator structure

Permanent magnets provide a possible solution to simplify complicated stellarator coils. Here, a prototype permanent magnet stellarator structure, PM4Stell, has been funded to demonstrate the technical feasibility of using permanent magnets to create the shaping field of a stellarator. Permanent magnets in uniform cubes with three polarization directions will be carefully placed to generate the required magnetic field for a National Compact Stellarator eXperiment-like equilibrium together with planar toroidal field coils. Discrete magnets will be glued together and inserted into a “post-office-box-like” supporting structure. Electromagnetic and structural analyses have been done to validate the design. Error field correction magnets will be used to shim possible error fields. The design efforts of the prototype permanent magnet stellarator structure are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements and correction of the 1/1 error field in Wendelstein 7-X

In this paper, vacuum flux surface mapping is used to measure the error field in Wendelstein 7-X. Two methods for discriminating the perturbation from other co-resonant modes are applied: measurements of the helical axis shift in a magnetic configuration with the rotational transform barely above one on the axis; and measurements of the edge island structure with cancellation of intrinsic islands by divertor control coils. The normalized radial amplitude in Boozer coordinates is found to be about in the first case and about in the second one, with the discrepancy being attributable to different currents in the planar coils. The error field can be reliably compensated by using error field trim coils with currents about 100 A. Here, this compensation also helps to identify the error field of about . During plasma operation in divertor configurations, it is confirmed that the present field leads to asymmetries in the power distribution and that the compensation improves this symmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels

Purpose: This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detailing these case studies is to explore different, more sensitive methods and metrics that could be used more effectively for evaluating accuracy of dose algorithms, delivery systems, and QA devices.Methods: The authors present seven real-world case studies representing a variety of combinations of the treatment planning system (TPS), linac, delivery modality, and systematic error type. These case studies are typical to what might be used as part of an IMRT or VMAT commissioning test suite, varying in complexity. Each case study is analyzed according to TG-119 instructions for gamma passing rates and action levels for per-beam and/or composite plan dosimetric QA. Then, each case study is analyzed in-depth with advanced diagnostic methods (dose profile examination, EPID-based measurements, dose difference pattern analysis, 3D measurement-guided dose reconstruction, and dose grid inspection) and more sensitive metrics (2% local normalization/2 mm DTA and estimated DVH comparisons).Results: For these case studies, the conventional 3%/3 mm gamma passing rates exceeded 99% for IMRT per-beam analyses and ranged from 93.9% to 100% for composite plan dose analysis, well above the TG-119 action levels of 90% and 88%, respectively. However, all cases had systematic errors that were detected only by using advanced diagnostic techniques and more sensitive metrics. The systematic errors caused variable but noteworthy impact, including estimated target dose coverage loss of up to 5.5% and local dose deviations up to 31.5%. Types of errors included TPS model settings, algorithm limitations, and modeling and alignment of QA phantoms in the TPS. Most of the errors were correctable after detection and diagnosis, and the uncorrectable errors provided useful information about system limitations, which is another key element of system commissioning.Conclusions: Many forms of relevant systematic errors can go undetected when the currently prevalent metrics for IMRT/VMAT commissioning are used. If alternative methods and metrics are used instead of (or in addition to) the conventional metrics, these errors are more likely to be detected, and only once they are detected can they be properly diagnosed and rooted out of the system. Removing systematic errors should be a goal not only of commissioning by the end users but also product validation by the manufacturers. For any systematic errors that cannot be removed, detecting and quantifying them is important as it will help the physicist understand the limits of the system and work with the manufacturer on improvements. In summary, IMRT and VMAT commissioning, along with product validation, would benefit from the retirement of the 3%/3 mm passing rates as a primary metric of performance, and the adoption instead of tighter tolerances, more diligent diagnostics, and more thorough analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

The application of VLB interferometry to earth measurements

Results of a four-phase development of capability in very long-baseline interferometry (VLBI) at the Smithsonian Astrophysical Observatory (SAO) are summarized. The objectives of the VLBI program at SAO are to: (1) develop the capability to collect, process, and analyze VLBI data; (2) determine experimentally the accuracy now attainable with VLBI and, within the constraints imposed by this accuracy, initiate a program of VLBI observations for geophysical applications; (3) identify all significant error sources and devise means for eliminating or correcting these errors; and (4) develop a long range plan for applying VLBI techniques to a program of earth physics measurements.

Michelini, R. D.↗

Analysis and quantification of errors in the geometric correction of satellite images

The quantitative use of remote sensing satellite images in many applications requires that the geometric distortion inherent in these images be corrected, or rectified, to a desired map projection. The most widely used technique relies on ground control points to empirically determine a mathematical coordinate transformation to correct the geometry. In this paper, using the method of least squares, expressions for the accuracy of the geometric transformation and of the rectification of the satellite image to a map projection are derived. Explicit relations between the global accuracy of the transformation and the number, location, and local accuracy of the ground control points are obtained. The results are applied to the correction of a Landsat MSS image.

Ford, G. E.↗

A verification regime for the spatial discretization of the SN transport equations

The order-of-accuracy test in conjunction with the method of manufactured solutions is the current state of the art in computer code verification. In this work we investigate the application of a verification procedure including the order-of-accuracy test on a generic SN transport solver that implements the AHOTN spatial discretization. Different types of semantic errors, e.g. removal of a line of code or changing a single character, are introduced randomly into the previously verified S{sub N} code and the proposed verification procedure is used to identify the coding mistakes (if possible) and classify them. Itemized by error type we record the stage of the verification procedure where the error is detected and report the frequency with which the errors are correctly identified at various stages of the verification. Errors that remain undetected by the verification procedure are further scrutinized to determine the reason why the introduced coding mistake eluded the verification procedure. The result of this work is that the verification procedure based on an order-of-accuracy test finds almost all detectable coding mistakes but rarely, 1.44% of the time, and under certain circumstances can fail. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Updating finite element dynamic models using an element-by-element sensitivity methodology

A sensitivity-based methodology for improving the finite element model of a given structure using test modal data and a few sensors is presented. The proposed method searches for both the location and sources of the mass and stiffness errors and does not interfere with the theory behind the finite element model while correcting these errors. The updating algorithm is derived from the unconstrained minimization of the squared L sub 2 norms of the modal dynamic residuals via an iterative two-step staggered procedure. At each iteration, the measured mode shapes are first expanded assuming that the model is error free, then the model parameters are corrected assuming that the expanded mode shapes are exact. The numerical algorithm is implemented in an element-by-element fashion and is capable of 'zooming' on the detected error locations. Several simulation examples which demonstate the potential of the proposed methodology are discussed.

Farhat, Charbel↗