Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Exploring the Neutron Substructure with Advanced Polarized Helium-3 Targets (Or: How I Learned to Stop Worrying and Love Spectroscopy)

As we seek to understand the smallest, physical aspects of our universe, we cannot simply rely on our senses to probe the world around us as we did in the past. The smallest physical elements of our universe behave in strange, probabilistic ways and are completely invisible to the naked eye/ear/etc. So, we design clever experiments (such as scattering experiments) to probe these minute realms. Then, just as with the larger, observable world, we devise models and equations to describe what we think is happening. Due to the nature of the physical universe at the quantum scale and with the aid of symmetries such as Lorentz invariance, we can write down equations that describe the scattering, but the expressions contain functions, which we call ?form factors? and ?structure functions?, that we cannot compute from first principles. We can, however, formulate models that make predictions for these functions. By comparing our predictions with the observed data, we can gain insight into the validity of our models and thus a better physical understanding of what is happening at these minuscule scales. Studying the constituents inside of the nucleus of an atom adds another layer of difficulty if we can?t remove those components from the nucleus. This is the case with the neutron. When not bound in the nucleus with protons and other neutrons, the neutron will decay into a proton after about 15 minutes. So, we?re forced to study the neutron while it is still bound in the nucleus of an atom such as helium-3 (3He). For the last 1,000 years (rounding up), our group has developed high quality, polarized 3He targets made of an aluminosilicate glass. These targets are made in order to perform experiments at Jefferson Lab (JLab), experiments which let us determine the form factors and structure functions of the neutron by scattering polarized electrons from polarized neutrons (or rather polarized 3He). The specific experiments reported on in this thesis push the bounds of our understanding of the internal structure of the neutron. Good science is often about pushing experimental techniques to a new level. Toward that goal we study our polarized 3He targets both to advance the technology and to choose the best ones for our experiments. We do this using a process called nuclear magnetic resonance (NMR) to gauge the maximum polarization of a target and how fast the polarization decays with time. While these tests primarily provide us information that make analysis of our experimental scattering data possible, they also let us determine whether or not a target-cell is useful or even, dare I say, of spectacular quality. Our latest targets utilize a novel convection design allowing 3He to be polarized and quickly moved in front of the electron-beam, making it possible to use larger targets with higher electron-beam currents than ever before. This means more electrons scatter and we get more data. And by studying our targets in detail prior to using them in our experiments, we have found techniques to take effects which could have been detrimental to target quality and turn them to our advantage! It?s a real case of making lemonade out of lemons. We also use laser spectroscopy to study the absorption lines of alkali-metals in the target (potassium and rubidium, specifically). We add these alkali-metals to our target to facilitate polarizing the 3He. We can use the measurement of these pressure broadened absorption lines to determine the 3He density inside of the target with great precision. Historically, we understood the width of these lines would be dependent on the temperature of the target. Specifically, if I raise the temperature, the width should get bigger. I found that was not the case, which was very confusing at first, though very exciting now that I realize the data are self-consistent and suggestive of unexpected behavior. This thesis details the development of high quality, glass, polarized 3He targets for the 2020 An 1 /dn 2 and 2023 Gn E experiments, which utilized the first 3He convection targets and broke records in target quality. This thesis also covers the initial development of metal windows for the next-generation of 3He target-cells. Finally, this thesis documents the temperature dependence of the width of potassium (K) and rubidium (Rb) absorption lines as measured with laser spectroscopy.

Jantzi, Christopher↗

Double grating shearing interferometry for X-ray free-electron laser beams

The advancements in bright and coherent X-ray free-electron lasers (XFEL) have in the last decade revolutionized diverse fields of study, leading to an ever-increasing demand in more intense X-ray pulses. The accurate knowledge of the wavefront and the focal profile of such pulses ultimately dictates much of the experimental outcome.Herewe present a singleshot shearing interferometry method to measure the wavefront of a focused hardXFELpulse.Twoidentical transmission gratings are placed near the focus, and the interference pattern of overlapping diffraction orders is analyzed, resulting in a two-dimensional reconstruction of the X-ray wavefront. The spatial resolution and wavefront sensitivity can be tuned insitu during the measurement. The method is non-invasive (i.e., the zeroth order or transmitted pulse is not modified in intensity or profile), allowing for either a simultaneous intensity measurement at high resolution or a fully characterized transmitted pulse for general experimental use.

47 OTHER INSTRUMENTATION↗

Conceptual design report: a ring-based electron cooling system for the EIC

This report describes a concept of an EIC cooling system, based on a proven induction-linac technology with a DC electron beam. The system would operate in a full energy range of proton beams (100–270 GeV) and would provide 50–100 A electron beams, circulating in a cooler ring for 5 ms. Every 5 ms a new electron pulse would be injected into the cooler ring to provide continuous cooling at collisions. Operations with a 10-ms cycle is possible but it will reduce the cooling rates by ~30%. The system is capable of delivering the required performance in the entire EIC energy range with emittance cooling times of less than 1–2 hours.

43 PARTICLE ACCELERATORS↗

Vehicle charging and potential on the STS-3 mission

An electron gun with fast pulse capability was used in the vehicle charging and potential experiment carried on the OSS-1 pallet to study dielectric charging, return current mechanisms, and the techniques required to manage the electrical charging of the orbiter. Return currents and charging of the dielectrics were measured during electron beam emission and plasma characteristics in the payload bay were determined in the absence of electron beam emission. The fast pulse electron generator, charge current probes, spherical retarding potential analyzer, and the digital control interface unit which comprise the experiment are described. Results show that the thrusters produce disturbances which are variable in character and magnitude. Strong ram/wake effects were seen in the ion densities in the bay. Vehicle potentials are variable with respect to the plasma and depend upon location on the vehicle relative to the main engine nozzles, the vehicle attitude, and the direction of the geomagnetic field.

Williamson, R.↗

Fast variations in high-energy X-rays from solar flares and their constraints on nonthermal models

The results of a quantitatve analysis of quantitative the temporal properties of over 7000 hard X-ray solar flares are presented. The data were obtained with the Hard X-ray Burst Spectrometer of the SMM satellite. The data reveal examples of hundreds of fast spikes with durations of less than 1 s. The spectra of a well-observed fast spike were compared with the predicted spectra of a detailed nonthermal electron beam model, in order to determine upper limits for electron beam parameters and path lengths. The theoretical spectra were found to be consistent with the observed spectra when the separation of between the accretion site and the thick target was greater than 10 to the 8th cm. It is shown that if the separation is much greater than 3 x 10 to the 9th cm, the electrons with high pitch angles (greater than 60 deg) are either not emitted or are mirrored before they reach the footpoints.

Kiplinger, A. L.↗

Radial radio frequency (RF) electron guns

Radial radio frequency (RF) electron guns and radial RF electron gun systems are provided that are capable of generating an electron beam that can propagate either radially inward, towards the axis of a cylinder, or radially outward from the axis. A beam source capable of generating a radially inwardly propagating electron beam, while perhaps not particularly useful as a source for a higher-energy accelerator, offers potential advantages for materials processing, as the geometry allows irradiation from all sides of an enclosed material flow with a single structure. Other potential applications include, but are not limited to, atmospheric plasma generation, radiation damage testing, and possibly, novel electron lens-type devices for hadron accelerators.

Lewellen, John↗

Impulsive solar X-ray bursts. III - Polarization, directivity, and spectrum of the reflected and total bremsstrahlung radiation from a beam of electrons directed toward the photosphere

The paper presents the spectrum, directivity, and state of polarization of the bremsstrahlung radiation expected from a beam of high-energy electrons spiraling along radial magnetic field lines toward the photosphere. A Monte Carlo method is then described for evaluation of the spectrum, directivity, and polarization of X-rays diffusely reflected from stellar photospheres. The accuracy of the technique is evaluated through comparison with analytic results. The calculated characteristics of the incident X-rays are used to evaluate the spectrum, directivity, and polarization of the reflected and total X-ray fluxes. The results are compared with observations.

Langer, S. H.↗

Laser and electron deflection from transverse asymmetries in laser-plasma accelerators

Here, we report on the deflection of laser pulses and accelerated electrons in a laser-plasma accelerator (LPA) by the effects of laser pulse front tilt and transverse density gradients. Asymmetry in the plasma index of refraction leads to laser steering, which can be due to a density gradient or spatiotemporal coupling of the laser pulse. The transverse forces from the skewed plasma wave can also lead to electron deflection relative to the laser. Quantitative models are proposed for both the laser and electron steering, which are confirmed by particle-in-cell simulations. Experiments with the BELLA Petawatt Laser are presented which show controllable 0.1-1 mrad laser and electron beam deflection from laser pulse front tilt. This has potential applications for electron beam pointing control, which is of paramount importance for LPA applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A High Intensity Spin-Polarized Electron Photogun to Drive a Polarized Positron Source

A photogun to generate a high-intensity, highly spin-polarized electron beam >90% with unprecedented charge lifetime in the kilocoulomb range is envisioned at JLab for a proposed Ce+BAF polarized positron beam source. The electron photogun is expected to provide a CW beam of >1 mA for a month without intervention. A limiting factor is ion-back bom-bardment on the strained-superlattice GaAs-photocathode which can be reduced by improving the photogun vacuum or biasing the anode. Additionally, increasing the laser spot size can help mitigate ion-induced damage. However, eventually the laser size becomes too large for the photogun electrode. An envisioned photogun design will incorporate larger electrodes to accommodate larger and off-center laser spot sizes. Compatible larger conical insulators which operate >300 kV for beam injection into a Beta~1 SRF booster are also necessary.

Hernandez Garcia, Carlos↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

Multiple reflection high-energy electron diffraction beam intensity measurement system

A video-based analysis system for reflection high-energy electron diffraction (RHEED) is described which simultaneously measures the intensities and profiles of multiple diffraction beams. This system is used to record real-time RHEED intensity oscillations for layer-by-layer epitaxial growth. Fast Fourier transform analysis of the oscillation data is used to directly determine the growth rate and to accurately obtain phase information about the oscillations. This system is demonstrated and compared to other methods of recording RHEED oscillation data.

Resh, J. S.↗

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

K-Modules: Capacitive Energy Modules for Pulsed Power Applications [Slides]

K-Modules are modules containing an assembly of capacitors. The modules are meant to be daisy-chained to form a Marx bank (bank of capacitors). Discharging the bank produces a high voltage, high current pulse, that when coupled to an X-ray or electron beam tube, generates X-rays or an intense electron beam. Number of modules in the stack can be varied to meet different pulsed power applications. The technology addresses the need for an alternate provider with a new, robust design. The technology has the potential to extend the life of the X-ray radiography program in the country.

43 PARTICLE ACCELERATORS↗

High efficiency klystron for the SPS application

The enhancement of klystron efficiency through the use of collector depression, that is by recovering energy from the spent electron beam after microwave amplification, was investigated. Design considerations included noise, harmonics, cooling, and service life. The mod anode, to be employed for beam control, and the depressed collector, used in spent electron beam energy recovery, are described.

Larue, A. D.↗

A New Kind of Curing

A new curing method using automated tape placement (ATP) with electron beam (EB), or e-beam, produces a combination known as in situ e-beam curing. Through a Small Business Innovation Research (SBIR) contract from NASA's Marshall Space Flight Center, Science Research Laboratory, Inc., created the in situ e-beam curing technique, which uses a low-energy electron beam gun to cure various composite materials. One important benefit is the technique's utilization of room temperature curing, which lessens the chance of mismatching the thermal expansion coefficients of different materials. For instance, metals and composites will expand at different rates when heated, but the low-energy e-beam gun reduces the expansion differential. Using a low-energy gun also results in less x-ray shielding, significantly reduced capital costs, reduced facility space, and increased processing capabilities for larger parts. However, using a low-energy gun also means that each tape layer is treated individually because the gun can penetrate only one layer at a time. The e-beam gun emits lower energy x-rays, which are more easily shielded than those emitted by previous guns. The low-energy system is relatively portable due to its light weight and small size. The gun weighs about 70 pounds and can be easily mounted on a robotic arm or an ATP head.

Source record↗

Concept of a polarized positron source for CEBAF

This thesis focuses on the development of polarized and unpolarized positron beams for the future experimental pro- gram of hadronic physics at the Thomas Jefferson National Accelerator Facility (JLab). The primary challenge is to produce high-duty-cycle and high-intensity polarized positron beams. The JLab positron source, which is based on the PEPPo (Polarized Electrons for Polarized Positrons) technique, aims to use a high intensity (1 mA) and highly polarized (90%) continuous electron beam of moderate energy (120 MeV) to produce either a low intensity (>50 nA), highly polarized (60%) positron beam or a high intensity (>1 ?A), unpolarized positron beam. The optimization of the layout and performance of the positron source is examined in this thesis. The source is designed with a specialized second injector to generate, transport, accelerate, and shape positron beams. It is compatible with acceleration at the Continuous Electron Beam Accelerator Facility (CEBAF), and the investigation results are presented in this document.

Habet, Sami↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Verification of computer-aided designs of traveling-wave tubes utilizing novel dynamic refocusers and graphite electrodes for the multistage depressed collector

A computational procedure for the design of TWT-refocuser-MDC systems was used to design a short dynamic refocusing system and highly efficient four-stage depressed collector for a 200-W, 8- to 18-GHz, TWT. The computations were carried out with advanced, multidimensional computer programs which model the electron beam as a series of disks of charge and follow their trajectories from the RF input of the TWT, through the slow-wave structure and refocusing section, to their points of impact in the depressed collector. Secondary emission losses in the MDC were treated semi-quantitatively by injecting a representative beam of secondary electrons into the MDC analysis at the point of impact of each primary beam. A comparison of computed and measured TWT and MDC performance showed very good agreement. The electrodes of the MDC were fabricated from a particular form of isotropic graphite that was selected for its low secondary electron yield, ease of machinability, and vacuum properties. This MDC was tested (at CW) for more than 1000 hr with negligible degradation in TWT and MDC performances.

Ramins, P.↗