Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “editing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

The 2014 Sandia Verification and Validation Challenge: Problem statement

This paper presents a case study in utilizing information from experiments, models, and verification and validation (V&V) to support a decision. It consists of a simple system with data and models provided, plus a safety requirement to assess. The goal is to pose a problem that is flexible enough to allow challengers to demonstrate a variety of approaches, but constrained enough to focus attention on a theme. This was accomplished by providing a good deal of background information in addition to the data, models, and code, but directing the participants' activities with specific deliverables. In this challenge, the theme is how to gather and present evidence about the quality of model predictions, in order to support a decision. This case study formed the basis of the 2014 Sandia V&V Challenge Workshop and this resulting special edition of the ASME Journal of Verification, Validation, and Uncertainty Quantification.

42 ENGINEERING↗

Introduction: The 2014 Sandia Verification and Validation Challenge Workshop [The 2014 Sandia Verification and Validation Challenge Workshop]

The 2014 Sandia Verification & Validation Challenge Workshop was held at the 3rd ASME Verification & Validation Symposium in Las Vegas, on May 5-8, 2014. The workshop was built around a challenge problem, formulated as an engineering investigation that required integration of experimental data, modeling and simulation, and verification and validation. The challenge problem served as a common basis for the ASME Journal of Verification, Validation, and Uncertainty Quantification participants to both demonstrate methodology and explore a critical aspect of the field: the role of verification and validation in establishing credibility and supporting decision making. Ten groups presented responses to the challenge problem at the workshop, and the follow-on efforts are documented in this special edition of the ASME Journal of Verification, Validation, and Uncertainty Quantification.

97 MATHEMATICS AND COMPUTING↗

EVALUATION OF ULTRASONIC PHASED-ARRAY FOR DETECTION OF PLANAR FLAWS IN HIGH-DENSITY POLYETHYLENE (HDPE) BUTT-FUSION JOINTS

The desire to use high-density polyethylene (HDPE) piping in buried Class 3 service and cooling water systems in nuclear power plants is primarily motivated by the material’s high resistance to corrosion relative to that of steel and metal alloys. The rules for construction of Class 3 HDPE pressure piping systems were originally published in Code Case N-755 and were recently incorporated into the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME BPVC) Section III as Mandatory Appendix XXVI (2015 Edition). The requirements for HDPE examination are guided by criteria developed for metal pipe and are based on industry-led HDPE research or conservative calculations.

HDPE↗

Next generation of extreme-resolution electron beam lithography

In top down nanofabrication research facilities around the world, the direct-write high-resolution patterning tool of choice is overwhelmingly electron beam lithography. Remarkably small features can be written in a variety of polymeric resists [V. R. Manfrinato et al., Nano Lett. 14, 4406 (2014); V. R. Manfrinato, A. Stein, L. Zhang, Y. Nam, K. G. Yager, E. A. Stach, and C. T. Black, Nano Lett. 17, 4562 (2017)]. However, this technology, which in this article the authors will refer to as conventional electron beam lithography (CEBL), is reaching its practical resolution and precision limits [V. R. Manfrinato et al., Nano Lett. 14, 4406 (2014)]. Hydrogen depassivation lithography (HDL) [J. N. Randall, J. W. Lyding, S. Schmucker, J. R. Von Ehr, J. Ballard, R. Saini, and Y. Ding, J. Vac. Sci. Technol. B 27, 2764 (2009); J. N. Randall, J. B. Ballard, J. W. Lyding, S. Schmucker, J. R. Von Ehr, R. Saini, H. Xu, and Y. Ding, Microelectron. Eng. 87, 955 (2010)] is a different version of electron beam lithography that is not limited in resolution and precision in the way that CEBL is. It uses a cold field emitter, a scanning tunneling microscope (STM) tip, to deliver a small spot of electrons on a Si (100) 2 × 1 H-passivated surface to expose a self-developing resist that is a monolayer of H adsorbed to the Si surface. Subnanometer features [S. Chen, H. Xu, K. E. J. Goh, L. Liu, and J. N. Randall, Nanotechnology 23, 275301 (2012)], and even the removal of single H atoms can be routinely accomplished [M. A. Walsh and M. C. Hersam, Annu. Rev. Phys. Chem. 60, 193 (2009)]. It is known that the H desorption process at low biases is a multielectron process [E. Foley, A. Kam, J. Lyding, and P. Avouris, Phys. Rev. Lett. 80, 1336 (1998)], but the tunneling distribution of the electrons from the STM tip to the Si surface lattice is not known. The authors have developed a simple model that demonstrates that the combination of two highly nonlinear processes creates a much higher contrast exposure mechanism than CEBL. Currently, HDL has been used almost exclusively on the Si (100) surface and has a limited number of pattern transfer techniques including Si and Ge patterned epitaxy, selective atomic layer deposition of TiO2 followed by reactive ion etching [J. B. Ballard, T. W. Sisson, J. H. G. Owen, W. R. Owen, E. Fuchs, J. Alexander, J. N. Randall, and J. R. Von Ehr, J. Vac. Sci. Technol. B 31, 06FC01 (2013)], and selective deposition of dopant atoms for quantum devices and materials [Workshop on 2D Quantum MetaMaterials held at NIST, Gaithersburg, MD, April 25–26, 2018, edited by J. Owen and W. P. Kirk]. While the throughput of HDL is very low, going parallel in a big way appears promising [J. N. Randall, J. H. G. Owen, J. Lake, R. Saini, E. Fuchs, M. Mahdavi, S. O. R. Moheimani, and B. C. Schaefer, J. Vac. Sci. Technol. B 36, 6 (2018)]. However, the most exciting aspect of HDL is its atomic-scale resolution and precision, which is key to nanoscale research. The authors see HDL emerging as the ultimate high-resolution patterning tool in top down nanofabrication research facilities.

42 ENGINEERING↗

Development and transferability of neural-network models for plasma-surface interactions

Plasma-surface interactions are increasingly critical to modern technologies; yet, accurate molecular dynamics simulations remain limited by the capabilities of interatomic potentials. Deep Potentials (DPs) promise to revolutionize the field by providing a systematic method for producing accurate interatomic potentials. The primary challenge of DP development is selecting a dataset, which efficiently spans the set of atomic environments one expects to encounter in the subsequent molecular dynamics simulations. The computational cost of density functional theory calculations, which are the typical basis for DP development, makes it impossible to directly verify the quality of a given DP. To address this challenge, we explore the development of a deep-learned interatomic potential, “DeepREBO,” trained to reproduce the behavior of the REBO2 empirical potential, enabling direct validation of training methodology and transferability. Using an active learning framework, we begin with a minimal dataset and iteratively expand it to train a Deep Potential-Smooth Edition model that faithfully reproduces REBO2 results for 25 eV hydrogen bombardment of diamond (001), a particularly challenging case. We show that small, carefully curated datasets can outperform large, unguided ones, with effective models requiring fewer than 15 000 snapshots. Subsequent transferability tests demonstrate that while DeepREBO generalizes well to diamond (111) surfaces, performance degrades for amorphous carbon or higher-energy impacts, highlighting the need for use-case-specific training data. We also evaluate methods to improve short-range repulsion. This study outlines best practices for training robust deep potentials and underscores the importance of dataset design for predictive plasma simulations.

Ab-initio molecular dynamics↗

Special Section Guest Editorial: Active Spectroscopy

A special edition of the journal Optical Engineering invited several scientists to participate in the editorial board of this special issue. The eleven papers in this special section cover recent developments in active spectroscopy, including new phenomenology and applications, advances in systems and components, and new methods for data processing and exploitation.

42 ENGINEERING↗

Photonic ring resonator notch filters for astronomical OH line suppression

Photonic ring resonator arrays used as notch filters are a promising novel solution to improve the signal-to-noise ratio of ground-based astronomical observations by suppressing OH emission lines in the near-infrared (NIR) wavelength range (0.9-2.5 μm). We aim to fabricate a series of ring resonators connected by a waveguide, each with its resonance wavelength and full-width-half-maximum (FWHM) matched with one of the OH emission lines. The fundamental structure of ring resonator-based notch filters is a ring resonator evanescently coupled to a waveguide. Due to the optical loss of the ring resonator, the transmission of light through the waveguide will be suppressed at the resonance wavelength of the ring resonator. The degree of suppression can be controlled by varying the coupling strength between the waveguide and the ring resonator, while the resonance wavelength can be controlled by the geometry and size of the ring. However, since a single ring resonator has multiple modes each with a different wavelength separated by its free spectral range (FSR), the additional suppression at other wavelengths may undermine the signal. Therefore, the ideal FSR off the ring resonators needs to be larger than the measurement window. For this application, we aim the FSR to be 1 larger than 30 nm . Our initial measurement results revealed two major challenges for this application. First, the FSR of the ring resonators is limited by the bending loss of ring resonators. In a standard 220 nm silicon-on-insulator material platform, the FSR of ring resonators cannot exceed 30 nm; Second, due to the wafer thickness variation and fabrication inaccuracy, the achievable accuracy in the resonance wavelength of a fabricated single ring resonator is only ~1.5 nm. In this work, we report our novel solutions to the above two challenges. For the first one, we have developed a novel structure based on the Vernier effect to greatly raise the FSR of ring resonators. Serially coupled Vernier ring structures is a typical approach to increase the FSR without encountering bending loss, but it requires restrictive matching of the coupling and optical loss of the rings and any imperfect matching can result in even noisier signals. On the contrary, our structure, as shown in shown in Fig. 1, does not require the restrictive matching. The signals of two output ports in our structure marked in Fig. 1 will be added together to form the final output signal, and Fig. 2 shows the finite-difference time-domain (FDTD) simulation results of the final output signal. As can be seen, the FSR of the entire structure is well-beyond 60 nm with little noise at other wavelengths. For the second one, we have developed an easy-to-implement method to permanently tune the resonance wavelengths of ring resonators within 0.1 nm accuracy. The tuning mechanism is based on the property of hydrogen silsesquioxane (HSQ) resist. As a negative tone electron beam resist, HSQ upon exposure will cross-link and eventually form SiO2. The refractive 2 index of HSQ resist and formed SiO2 are slightly different , enabling the tuning. By having a thin layer of HSQ resist on top of ring resonator structures followed by SiO2 cladding, the resonance wavelengths of ring resonators can be post-tuned Advances in Optical Astronomical Instrumentation 2019, edited by Simon Ellis, Céline d'Orgeville, Downloaded From: https://www.spiedigitallibrary.org/conference-proceedings-of-spie on 23 Sep 2020 Terms of Use: https://www.spiedigitallibrary.org/terms-of-use through electron beam exposure. We have found that, within 5 nm tuning range, the resonance wavelength shift and dosage applied obeys a linear relationship. So a simple calibration beforehand can result in resonance wavelength tuning within 0.1 nm accuracy. The transmission spectra of a 3-ring device before and after tuning is shown in Fig. 3.

Astronomical optics↗

3D reconstruction and neural rendering for adversarial machine learning

While evasion attacks on computer vision systems have been widely studied, creating attacks that remain effective under significant changes in viewpoint continues to be challenging. Traditional approaches often rely on affine transformations of images, but these approaches degrade at larger perspective shifts and often produce unrealistic or ineffective perturbations. Recent methods use differentiable renderers to improve viewpoint robustness, but they typically depend on manually constructed 3D models. We introduce a semi-automated pipeline that generates physically printable and perspective-invariant adversarial patches using only a small set of 2D images. Our method integrates 3D reconstruction, neural rendering, adversarial patch optimization, and an object detection victim model into a unified workflow. We use 2D Gaussian Splatting for high fidelity mesh reconstruction and FlexPara for surface parameterization that produces texture maps suitable for patch editing. Together, these components form a fully differentiable pipeline in PyTorch3D that links texture modification to model outputs, enabling efficient optimization of patches that remain effective across many viewpoints. The complete process, from image capture to patch printing and physical evaluation, can be completed within a few hours. We demonstrate the effectiveness of the resulting patches through attacks on the YOLOv8 object detection model and discuss remaining challenges and opportunities for improving robustness and scalability.

Singhvi, Vivaan [ORNL] (ORCID:0009000586288221)↗

Objective assessment of deformable image registration in radiotherapy: A multi-institution study

The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area are based on the ability of alignment to reproduce analytically generated deformations applied to sample image data, or use of contours or bifurcations as ground truth for evaluation of alignment accuracy. In this study, a deformable phantom was embedded with 48 small plastic markers, placed in regions varying from high contrast to roughly uniform regional intensity, and small to large regional discontinuities in movement. CT volumes of this phantom were acquired at different deformation states. After manual localization of marker coordinates, images were edited to remove the markers. The resulting image volumes were sent to five collaborating institutions, each of which has developed previously published deformable alignment tools routinely in use. Alignments were done, and applied to the list of reference coordinates at the inhale state. The transformed coordinates were compared to the actual marker locations at exhale. A total of eight alignment techniques were tested from the six institutions. All algorithms performed generally well, as compared to previous publications. Average errors in predicted location ranged from 1.5 to 3.9 mm, depending on technique. No algorithm was uniformly accurate across all regions of the phantom, with maximum errors ranging from 5.1 to 15.4 mm. Larger errors were seen in regions near significant shape changes, as well as areas with uniform contrast but large local motion discontinuity. Although reasonable accuracy was achieved overall, the variation of error in different regions suggests caution in globally accepting the results from deformable alignment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment and management of interfractional variations in daily diagnostic-quality-CT guided prostate-bed irradiation after prostatectomy

Purpose: To quantify interfractional anatomic variations and limitations of the current practice of image-guided radiation therapy (IGRT) for prostate-bed patients and to study dosimetric benefits of an online adaptive replanning scheme that addresses the interfractional variations. Methods: Contours for the targets and organs at risk (OARs) from daily diagnostic-quality CTs acquired with in-room CT (CTVision, Siemens) were generated by populating the planning contours using an autosegmentation tool based on deformable registration (ABAS, Elekta) with manual editing for ten prostate-bed patients treated with postoperative daily CT-guided IMRT. Dice similarity coefficient (DSC) obtained by maximizing the overlap of contours for a structure between the daily and plan contours was used to quantify the organ deformation between the plan and daily CTs. Three interfractional-variation-correction schemes, the current standard practice of IGRT repositioning, a previously developed online adaptive RT (ART), and the full reoptimization, were applied to these daily CTs and a number of dose-volume quantities for the targets and organs at risk were compared for their effectiveness to account for the interfractional variations. Results: Large interfractional organ deformations in prostate-bed irradiation were seen. The mean DSCs for CTV, rectum, and bladder were 86.6 ± 5.1% (range from 61% to 97%), 77.3% ± 7.4% (range from 55% to 90%), and 75.4% ± 11.2% (range from 46% to 96%), respectively. The fractional and cumulative dose-volume quantities for CTV and PTV: V100 (volume received at least 100% prescription dose), and rectum and bladder: V{sub 45Gy} and V{sub 60Gy} (volume received at least 45 or 60 Gy), were compared for the repositioning, adaptive, reoptimization, and original plans. The fractional and cumulative dosimetric results were nearly the same. The average cumulative CTV V100 were 88.0%, 98.4%, 99.2%, and 99.3% for the IGRT, ART, reoptimization, and original plans, respectively. The corresponding rectal V{sub 45Gy} (V{sub 60Gy}) were 58.7% (27.3%), 48.1% (20.7%), 43.8% (16.1%), and 44.9% (16.8%). The results for bladder were comparable among three schemes. Paired two-tailed Wilcoxon signed-rank tests were performed and it was found that ART and reoptimization provide better target coverage and better OAR sparing, especially rectum sparing. Conclusions: The interfractional organ motions and deformations during prostate-bed irradiation are significant. The online adaptive replanning scheme is capable of effectively addressing the large organ deformation, resulting in cumulative doses equivalent to those originally planned.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-16A-02: A Novel Methodology for Accurate, Semi-Automated Delineation of Oral Mucosa for Radiation Therapy Dose-Response Studies

Purpose: The significant morbidity caused by radiation-induced acute oral mucositis means that studies aiming to elucidate dose-response relationships in this tissue are a high priority. However, there is currently no standardized method for delineating the mucosal structures within the oral cavity. This report describes the development of a methodology to delineate the oral mucosa accurately on CT scans in a semi-automated manner. Methods: An oral mucosa atlas for automated segmentation was constructed using the RayStation Atlas-Based Segmentation (ABS) module. A radiation oncologist manually delineated the full surface of the oral mucosa on a planning CT scan of a patient receiving radiotherapy (RT) to the head and neck region. A 3mm fixed annulus was added to incorporate the mucosal wall thickness. This structure was saved as an atlas template. ABS followed by model-based segmentation was performed on four further patients sequentially, adding each patient to the atlas. Manual editing of the automatically segmented structure was performed. A dose comparison between these contours and previously used oral cavity volume contours was performed. Results: The new approach was successful in delineating the mucosa, as assessed by an experienced radiation oncologist, when applied to a new series of patients receiving head and neck RT. Reductions in the mean doses obtained when using the new delineation approach, compared with the previously used technique, were demonstrated for all patients (median: 36.0%, range: 25.6% – 39.6%) and were of a magnitude that might be expected to be clinically significant. Differences in the maximum dose that might reasonably be expected to be clinically significant were observed for two patients. Conclusion: The method developed provides a means of obtaining the dose distribution delivered to the oral mucosa more accurately than has previously been achieved. This will enable the acquisition of high quality dosimetric data for use in dose-response studies. We would like to thank the Engineering and Physical Sciences Research Council for funding. We acknowledge support from the NIHR RM/ICR Biomedical Research Centre. RayStatation was used under an evaluation agreement with RaySearch Laboratories AB.

60 APPLIED LIFE SCIENCES↗

SU-E-J-241: Creation of Ventilation CT From Daily 4D CTs Or 4D Conebeam CTs Acquired During IGRT for Thoracic Cancers

Purpose: To develop a method to create ventilation CTs from daily 4D CTs or 4D KV conebeam CTs (4DCBCT) acquired during image-guided radiation therapy (IGRT) for thoracic tumors, and to explore the potential for using the ventilation CTs as a means for early detection of lung injury during radiation treatment. Methods: 4DCT acquired using an in-room CT (CTVision, Siemens) and 4DCBCT acquired using the X-ray Volume Imaging (XVI) system (Infinity, Elekta) for representative lung cancer patients were analyzed. These 4D data sets were sorted into 10 phase images. A newly-available deformable image registration tool (ADMIRE, Elekta) is used to deform the phase images at the end of exhale (EE) to the phase images at the end of inhale (EI). The lung volumes at EI and EE were carefully contoured using an intensity-based auto-contour tool and then manually edited. The ventilation images were calculated from the variations of CT numbers of those voxels masked by the lung contour at EI between the registered phase images. The deformable image registration is also performed between the daily 4D images and planning 4DCT, and the resulting deformable field vector (DFV) is used to deform the planning doses to the daily images by an in-house Matlab program. Results: The ventilation images were successfully created. The tide volumes calculated using the ventilation images agree with those measured through volume difference of contours at EE and EI, indicating the accuracy of ventilation images. The association between the delivered doses and the change of lung ventilation from the daily ventilation CTs is identified. Conclusions: A method to create the ventilation CT using daily 4DCTs or 4D KV conebeam CTs was developed and demonstrated.

60 APPLIED LIFE SCIENCES↗

SU-E-T-488: An Iso-Dose Curve Based Interactive IMRT Optimization System for Physician-Driven Plan Tuning

Purpose: In treatment plan optimization for Intensity Modulated Radiation Therapy (IMRT), after a plan is initially developed by a dosimetrist, the attending physician evaluates its quality and often would like to improve it. As opposed to having the dosimetrist implement the improvements, it is desirable to have the physician directly and efficiently modify the plan for a more streamlined and effective workflow. In this project, we developed an interactive optimization system for physicians to conveniently and efficiently fine-tune iso-dose curves. Methods: An interactive interface is developed under C++/Qt. The physician first examines iso-dose lines. S/he then picks an iso-dose curve to be improved and drags it to a more desired configuration using a computer mouse or touchpad. Once the mouse is released, a voxel-based optimization engine is launched. The weighting factors corresponding to voxels between the iso-dose lines before and after the dragging are modified. The underlying algorithm then takes these factors as input to re-optimize the plan in near real-time on a GPU platform, yielding a new plan best matching the physician's desire. The re-optimized DVHs and iso-dose curves are then updated for the next iteration of modifications. This process is repeated until a physician satisfactory plan is achieved. Results: We have tested this system for a series of IMRT plans. Results indicate that our system provides the physicians an intuitive and efficient tool to edit the iso-dose curves according to their preference. The input information is used to guide plan re-optimization, which is achieved in near real-time using our GPU-based optimization engine. Typically, a satisfactory plan can be developed by a physician in a few minutes using this tool. Conclusion: With our system, physicians are able to manipulate iso-dose curves according to their preferences. Preliminary results demonstrate the feasibility and effectiveness of this tool.

60 APPLIED LIFE SCIENCES↗

SU-E-T-556: Dosimetric Comparison of the Bladder and Rectum Based On Daily CBCT for Prostate IMRT

Purpose: With the use of CBCT, delivered dose can be calculated by transferring the planned beams onto the CBCT. Bladder and rectum volumetric doses were calculated and correlated to the daily bladder and rectum fullness. Methods: Patients for this study underwent hypofractionated prostate IMRT to 70 Gy in 28 fractions. Daily CBCT was utilized for image guidance. A clinically acceptable plan was created using a CTV to PTV margin of 5mm. Image fusion was performed to transfer the bladder and rectum contours onto each CBCT. Contours were then edited to match the anatomy of each CBCT. Using the daily treatment isocenter, the planned beams were transferred onto the CBCT and daily and cumulative DVHs calculated. Results: At the time of planning the bladder volume was 470.66cc. The mean, minimum and maximum bladder volume from the 28 CBCTs was 230.57cc, 76.16 cc and 380.8 cc, respectively. Planned bladder V70Gy was 0.98%. Actual bladder V70Gy, as calculated from the CBCTs was 2.46±1.36%. Similarly, planned V60Gy, V50Gy and V40Gy were 2.55%, 4.15% and 6.35% of the total bladder volume. The observed volumes receiving 60Gy, 50Gy and 40Gy were 5.18±2.53%, 4 to 8.21±3.76% and 6 to 12.93±5.60%, respectively. On the planning CT the rectum volume was 41.5cc. The observed mean, minimum and maximum rectum volumes were 58.09cc, 93.52 and 47.50cc. The planned rectum V70Gy was 6.02% while the observed cumulative rectum V70Gy was 13.68±3.39%. Rectum V60Gy, V50Gy and V40Gy changed from 13.61% to 22.5±3.86%, 19.15% to 28.68±4.45 and 25.56% to 34.75±5.15%. Conclusion: Bladder and rectum volumes changes during treatment have an affect on the cumulative dose received by these organs. It was observed that volumetric dose received by bladder decreases as volume of the bladder increases. There is no particular trend observed between volumetric dose and rectal volume.

60 APPLIED LIFE SCIENCES↗

MO-C-17A-06: Online Adaptive Re-Planning to Account for Independent Motions Between Multiple Targets During Radiotherapy of Lung Cancer

Purpose: To quantify interfractional independent motions between multiple targets in radiotherapy (RT) of lung cancer, and to study the dosimetric benefits of an online adaptive replanning method to account for these variations. Methods: Ninety five diagnostic-quality daily CTs acquired for 9 lung cancer patients treated with IGRT using an in-room CT (CTVision, Siemens) were analyzed. On each daily CT set, contours of the targets (GTV, CTV, or involved nodes) and organs at risk were generated by populating the planning contours using an auto-segmentation tool (ABAS, Elekta) with manual editing. For each patient, an IMRT plan was generated based on the planning CT with a prescription dose of 60 Gy in 2Gy fractions. Three plans were generated and compared for each daily CT set: an IGRT (repositioning) plan by copying the original plan with the required shifts, an online adaptive plan by rapidly modifying the aperture shapes and segment weights of the original plan to conform to the daily anatomy, and a new fully re-optimized plan based on the daily CT using a planning system (Panther, Prowess). Results: The daily deviations of the distance between centers of masses of the targets from the plans varied daily from -10 to 8 mm with an average −0.9±4.1 mm (one standard deviation). The average CTV V100 are 99.0±0.7%, 97.9±2.8%, 99.0±0.6%, and 99.1±0.6%, and the lung V20 Gy 928±332 cc, 944±315 cc, 917±300 cc, and 891±295 cc for the original, repositioning, adaptive, and re-optimized plans, respectively. Wilcoxon signed-rank tests show that the adaptive plans are statistically significantly better than the repositioning plans and comparable with the reoptimized plans. Conclusion: There exist unpredictable, interfractional, relative volume changes and independent motions between multiple targets during lung cancer RT which cannot be accounted for by the current IGRT repositioning but can be corrected by the online adaptive replanning method.

60 APPLIED LIFE SCIENCES↗

TU-C-17A-03: An Integrated Contour Evaluation Software Tool Using Supervised Pattern Recognition for Radiotherapy

Purpose: Radiotherapy (RT) contours delineated either manually or semiautomatically require verification before clinical usage. Manual evaluation is very time consuming. A new integrated software tool using supervised pattern contour recognition was thus developed to facilitate this process. Methods: The contouring tool was developed using an object-oriented programming language C# and application programming interfaces, e.g. visualization toolkit (VTK). The C# language served as the tool design basis. The Accord.Net scientific computing libraries were utilized for the required statistical data processing and pattern recognition, while the VTK was used to build and render 3-D mesh models from critical RT structures in real-time and 360° visualization. Principal component analysis (PCA) was used for system self-updating geometry variations of normal structures based on physician-approved RT contours as a training dataset. The inhouse design of supervised PCA-based contour recognition method was used for automatically evaluating contour normality/abnormality. The function for reporting the contour evaluation results was implemented by using C# and Windows Form Designer. Results: The software input was RT simulation images and RT structures from commercial clinical treatment planning systems. Several abilities were demonstrated: automatic assessment of RT contours, file loading/saving of various modality medical images and RT contours, and generation/visualization of 3-D images and anatomical models. Moreover, it supported the 360° rendering of the RT structures in a multi-slice view, which allows physicians to visually check and edit abnormally contoured structures. Conclusion: This new software integrates the supervised learning framework with image processing and graphical visualization modules for RT contour verification. This tool has great potential for facilitating treatment planning with the assistance of an automatic contour evaluation module in avoiding unnecessary manual verification for physicians/dosimetrists. In addition, its nature as a compact and stand-alone tool allows for future extensibility to include additional functions for physicians’ clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 52: A Web-based Platform for Collaborative Document Management in Radiotherapy

We describe DepDocs, a web-based platform that we have developed to manage the committee meetings, policies, procedures and other documents within our otherwise paperless radiotherapy clinic. DepDocs is essentially a document management system based on the popular Drupal content management software. For security and confidentiality, it is hosted on a linux server internal to our hospital network such that documents are never sent to the cloud or outside of the hospital firewall. We used Drupal's in-built role-based user rights management system to assign a role, and associated document editing rights, to each user. Documents are accessed for viewing using either a simple Google-like search or by generating a list of related documents from a taxonomy of categorization terms. Our system provides document revision tracking and an document review and approval mechanism for all official policies and procedures. Committee meeting schedules, agendas and minutes are maintained by committee chairs and are restricted to committee members. DepDocs has been operational within our department for over six months and has already 45 unique users and an archive of over 1000 documents, mostly policies and procedures. Documents are easily retrievable from the system using any web browser within our hospital's network.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-201-06: Random Walk Algorithm Seed Localization Parameters in Lung Positron Emission Tomography (PET) Images

Purpose: The objective of this study was to find the best seed localization parameters in random walk algorithm application to lung tumor delineation in Positron Emission Tomography (PET) images. Methods: PET images suffer from statistical noise and therefore tumor delineation in these images is a challenging task. Random walk algorithm, a graph based image segmentation technique, has reliable image noise robustness. Also its fast computation and fast editing characteristics make it powerful for clinical purposes. We implemented the random walk algorithm using MATLAB codes. The validation and verification of the algorithm have been done by 4D-NCAT phantom with spherical lung lesions in different diameters from 20 to 90 mm (with incremental steps of 10 mm) and different tumor to background ratios of 4:1 and 8:1. STIR (Software for Tomographic Image Reconstruction) has been applied to reconstruct the phantom PET images with different pixel sizes of 2×2×2 and 4×4×4 mm{sup 3}. For seed localization, we selected pixels with different maximum Standardized Uptake Value (SUVmax) percentages, at least (70%, 80%, 90% and 100%) SUVmax for foreground seeds and up to (20% to 55%, 5% increment) SUVmax for background seeds. Also, for investigation of algorithm performance on clinical data, 19 patients with lung tumor were studied. The resulted contours from algorithm have been compared with nuclear medicine expert manual contouring as ground truth. Results: Phantom and clinical lesion segmentation have shown that the best segmentation results obtained by selecting the pixels with at least 70% SUVmax as foreground seeds and pixels up to 30% SUVmax as background seeds respectively. The mean Dice Similarity Coefficient of 94% ± 5% (83% ± 6%) and mean Hausdorff Distance of 1 (2) pixels have been obtained for phantom (clinical) study. Conclusion: The accurate results of random walk algorithm in PET image segmentation assure its application for radiation treatment planning and diagnosis.

60 APPLIED LIFE SCIENCES↗