Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “eclipse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

SU-E-T-215: Comparison of VMAT-SABR Treatment Plans with Flattened Filter (FF) Beam and Flattening Filter-Free (FFF) Beam for Localized Prostate Cancer

Purpose: The purpose of this study is to access VMAT-SABR plan using flattening filter (FF) and flattening filter-free (FFF) beam, and compare the verification results for all pretreatment plans. Methods: SABR plans for 20 prostate patients were optimized in the Eclipse treatment planning system. A prescription dose was 42.7 Gy/7 fractions. Four SABR plans for each patient were calculated using Acuros XB algorithm with both FF and FFF beams of 6- and 10-MV. The dose-volume histograms (DVH) and technical parameters were recorded and compared. A pretreatment verification was performed and the gamma analysis was used to quantify the agreement between calculations and measurements. Results: For each patient, the DVHs are closely similar for plans of four different beams. There are small differences showed in dose distributions and corresponding DVHs when comparing the each plan related to the same patient. Sparing on bladder and rectum was slightly better on plans with 10-MV FF and FFF than with 6-MV FF and FFF, but this difference was negligible. However, there was no significance in the other OARs. The mean agreement of 3%/3mm criteria was higher than 97% in all plans. The mean MUs and deliver time employed was 1701±101 and 3.02±0.17 min for 6-MV FF, 1870±116 and 1.69±0.08 min for 6-MV FFF, 1471±86 and 2.68±0.14 min for 10-MV FF, and 1619±101 and 0.98±0.04 min for 10-MV FFF, respectively. Conclusion: Dose distributions on prostate SABR plans using FFF beams were similar to those generated by FF beams. However, the use of FFF beam offers a clear benefit in delivery time when compared to FF beam. Verification of pretreatment also represented the acceptable and comparable results in all plans using FF beam as well as FFF beam. Therefore, this study suggests that the use of FFF beam is feasible and efficient technique for prostate SABR.

60 APPLIED LIFE SCIENCES↗

SU-E-T-217: Comprehensive Dosimetric Evaluation On 3D-CRT, IMRT and Non-Coplanar Arc Treatment for Prone Accelerated Partial Breast Irradiation (APBI)

Purpose: Accelerated partial breast irradiation (APBI) is an effective treatment for early stage breast-cancer. Irradiation in a prone position can mitigate breast motion and spare heart and lung. In this study, a comprehensive study is performed to evaluate various treatment techniques for prone APBI treatment including: 3D-CRT, IMRT, co-planar and non-coplanar partial arcs treatment. Methods: In this treatment planning study, a left breast patient treated in prone position in our clinic was imported into Varian Eclipse TPS. Six beams tangential to chest wall were used in both 3D-CRT and IMRT plans. These six beams were coplanar in a transactional plane achieved by both gantry and couch rotation. A 60-beam IMRT plan was also created to explore the maximum benefit of co-planar IMRT. Within deliverable couch rotation range (±30°), partial arc treatment plans with one and up to ten couch positions were generated for comparison. For each plan, 30Gy in 6 fractions was prescribed to 95% PTV volume. Critical dosimetric parameters, such as conformity index, mean, maximum, and volume dose of organ at risk, are evaluated. Results: The conformity indexes (CI) are 3.53, 3.17, 2.21 and 1.08 respectively to 3D-CRT, 6-beam IMRT, 60-beam IMRT, and two-partial-arcs coplanar plans. However, arc plans increase heart dose. CI for non-coplanar arc plans decreases from 1.19 to 1.10 when increases couch positions. Maximum dose in ipsilateral lung (1.98 to 1.13 Gy), and heart (0.62 to 0.43 Gy) are steadily decreased with the increased number of non-coplanar arcs. Conclusions: The dosimetric evaluation results show that partial arc plans have improved CIs compared to conventional 3D-CRT and IMRT plans. Increasing number of partial arcs decreases lung and heart dose. The dosimetric benefit obtained from non-coplanar arcs should be considered with treatment delivery time.

60 APPLIED LIFE SCIENCES↗

SU-E-T-224: Considerations for the Proper Treatment of Multiple Cranial Metastases with Single Isocenter Volumetric Modulated Arc Therapy

Purpose: To investigate some limitations of single isocenter VMAT for cranial multiple met cases. Methods: A single isocenter VMAT plan (Varian, Eclipse AAA10 commissioned down to 1 cm) was designed for two 7mm diameter spherical targets in a rectangular Solid Water (Gammex) phantom. The targets were separated by a distance of 6cm and the isocenter was centered in one of the targets. The plan was delivered (Varian, Truebeam STx) three separate times with different artificial couch angle errors of 0, 0.5 and 1 degree. The coronal dose distributions were measured with calibrated EBT3 film placed at mid-phantom. EBT3 film dosimetry was also performed on the delivery of separate multiple arc vmat plans to targets below 6mm in diameter. Results: Measurements of the sup/inf dose profiles through the high dose distributions show no movement of the central axis high dose region and shifts of the high dose region intended for the off-axis target. For the 1 degree rotation error, the high dose region was shifted 1.04mm from the target. This corresponds to the shift expected from triangulation (60mmxTan(1deg)=1.047mm). Furthermore, a streak of 10% interleaf leakage dose was observed and is likely a Result of the off axis target traveling a wide path such that a long length of MLC is exposed for the whole arc. The calculated dose was about 10% to 15% low compared to that measured on film for a 5mm diameter target. Conclusion: Judicious use of additional margin for off axis targets or limits on the span of multiple mets treated with one isocenter is recommended. The magnitude of the margin should be based on the rotational errors evaluated for the positioning system and the distance of the target from the isocenter. A lower limit of lesion size that can be accurately treated with VMAT should be determined.

60 APPLIED LIFE SCIENCES↗

SU-E-T-229: Craniospinal Radiotherapy Planning with VMAT, Two First Years Experience

Purpose: To describe how we moved to VMAT in the craniospinal radiotherapy planning process, the actual procedure details, and the results for the patients treated. Methods: Twelve patients underwent craniospinal irradiation with the new procedure, based on the paper by Lee et al. (IJROBP 82, 2012), with some additional modifications. Patients were treated in supine position in Varian Clinac iX linacs with 6 MV RapidArc; prescription doses ranged from 23.4 to 40 Gy (13 to 20 fractions); depending on the PTV length, 2 or 3 isocenters were used, all coordinates being equal except the longitudinal one, setting a few centimeter-long overlapping region; 2 arcs (RA) sharing isocentre for the cranial region, RA1 encompassing cranium and superior spinal region, and RA2 intended to improve conformity, only for cranium; for spine, 1 or 2 isocenters were employed; optimization was performed with Eclipse (V 13.0) using AAA algorithm, establishing sets of optimization parameters to give high conformity while sparing OAR. In pediatric patients, homogeneous irradiation of the vertebrae was also required.Conformity (CI) and heterogeneity (HI) indices (same as Lee et al.), and mean and maximum doses for OAR were calculated. Several pre-treatment verification methods were used: Octavius4D (PTW) for each isocentre, point dose at the junction region, Portal Dosimetry (when possible), and independent MU verification software (Diamond, PTW). Results: CI median value was 1.02 (0.99–1.07) and HI, 1.07 (1.06–1.09); a great reduction was observed for CI and OAR mean doses with respect to Lee et al. data; median maximum eye lens dose was 7.3 Gy (4.0–12.0); mean LungV20Gy was 1.9%; in children, vertebrae were homogeneously irradiated (D95%=20.8 Gy, Dmean= 23.2 Gy).All pre-treatment verifications were found within our action levels except for Portal Dosimetry. Conclusion: A RapidArc planning process for craniospinal axis irradiation has been implemented with significant advantages on conformity, homogeneity, feasibility and efficiency. and increase brain tissue sparing. Variations in volume decrease may be related to shape or location of the tumor.

60 APPLIED LIFE SCIENCES↗

SU-E-T-235: Data Mining for Evaluating Treatment Performances Over a Large Quantity of Data to Monitor and Improve SBRT Workflow

Purpose: To quality assure a large quantity of retrospective treatment cases for treatment performances by randomly sampling is inefficient. Here we provide a method to efficiently monitor and investigate the QA of SBRT workflow over Mosaiq. Methods: The code developed with Microsoft SQL Server Management Studio 2008R2 and VBA was used for retrieving and sorting data from Mosaiq (version 2.3–2.6 during 2012–2015). SBRT patients were filtered by fractional dose over 350cGy and total fraction number less than 6, which SBRT prescriptions were defined. The quality assurance on the SBRT workflow was focused on the treatment deliveries such as patient positioning setup, CBCT indicated offsets and couch shifted corrections. The treatment delivery were done by Varian Truebeam systems and the record/verify by Mosaiq. Results: Total 82 SBRT patients corresponding to 103 courses and 854 CBCT images were found by the retrieval query. Most centers record daily pre-treatment (Pre-Tx: before treatment shift) image-guided shifts along treatment course for inter-fraction motion record, and it is useful to also verify it with post-treatment imaging (Post-Tx: after treatment CBCT verification) to verify intra-fraction motion. Analyzing the details of daily recorded shifts can reveals the information of patient-setup and staff’s record/verify behaviors. 3 examples were provided as solid evidences and on-going rectification for preventing future mistakes. Conclusions: The report gave feasible examples for inspector to verify a large amount of data during site investigation. This program can also be extended to a scheduled data mining with software to periodical analyze the timely records in Mosaiq, for example, a various control charts for different QA purposes. As the current trend of automation in radiation therapy field, the data mining would be a necessary tool in the future, just as the automatic plan quality evaluation has been under development in Eclipse.

60 APPLIED LIFE SCIENCES↗

SU-E-T-308: Dosimetric Comparison of SBRT VMAT Treatment Plans Generated for 6 MV, 6 MV FFF, and 10 MV FFF Photon Beams

Purpose: To assess differences in treatment plan quality between VMAT stereotactic body plans generated using the 6 MV, 6 MV FFF, and 10 MV FFF modalities available in our clinic. Plans for lung, spine, and other sites were compared to see if there is any advantage of one modality over the other. Methods: Treatment plans done for actual SBRT patients were selected. Groups of ten lung plans, five spine plans, and five plans from other sites were selected. New treatment plans were generated for each plan using the Varian Eclipse AAA algorithm. The constraints were kept the same as used in the actual plans, but the same version of software was used to generate plans for the three modalities. In addition, because there are natural variations in plans re-done with the same dose constraints, one of the lung plans was repeated ten times to assess those differences. Volumes of the 100%, 90%, 50%, 20% and 10% isodose surfaces were compared. Maximum dose two centimeters from the PTV were compared, as well as the volume of the 105% isodose surface outside of the PTV. In addition, the 20 Gray lung volume was compared for the lung plans. The values of these parameters were divided by the values for the 6 MV plans for comparison. Average and standard deviations were obtained for quantities in each group. The Student t test was done to determine if differences were seen at the 95% confidence level. Results: Comparison of the treatment plans showed no significant differences when assessing these volumes and doses. There were not any trends seen when comparing modalities as a function of PTV volume either. Conclusion: There is no obvious dosimetric advantage in selection of one modality over another for these types of SBRT plans.

60 APPLIED LIFE SCIENCES↗

SU-E-T-311: Dosimetric Comparison of Volumetric Modulated Arc Therapy Plans for Preoperative Radiotherapy Rectal Cancer Using Flattening Filter-Free and Flattening Filter Modes

Purpose: To compare the dosimetric difference of volumetric modulated arc therapy(VMAT) for preoperative radiotherapy rectal cancer using 6MV X-ray flattening filter free(FFF) and flattening filter(FF) modes. Methods: FF-VMAT and FFF-VMAT plans were designed to 15 rectal cancer patients with preoperative radiotherapy by planning treatment system(Eclipse 10.0),respectively. Dose prescription was 50 Gy in 25 fractions. All plans were normalized to 50 Gy to 95% of PTV. The Dose Volume Histogram (DVH), target and risk organ doses, conformity indexes (CI), homogeneity indexes (HI), low dose volume of normal tissue(BP), monitor units(MU) and treatment time (TT) were compared between the two kinds of plans. Results: FF-VMAT provided the lower Dmean, V105, HI, and higher CI as compared with FFF-VMAT. The small intestine of D5, Bladder of D5, Dmean, V40, V50, L-femoral head of V40, R-femoral head of Dmean were lower in FF-VMAT than in FFF-VMAT. FF-VMAT had higher BP of V5, but no significantly different of V10, V15, V20, V30 as compared with FFF-VMAT. FF-VMAT reduceed the monitor units(MU) by 21%(P<0.05), as well as the treatment time(TT) was no significantly different(P>0.05), as compared with FFF-VMAT. Conclusion: The plan qualities of FF and FFF VMAT plans were comparable and both clinically acceptable. FF-VMAT as compared with FFF-VMAT, showing better target coverage, some of OARs sparing, the MUs of FFF-VMAT were higher than FF-VMAT, yet were delivered within the same time. This work was supported by the Medical Scientific Research Foundation of Guangdong Procvince (A2014455 to Changchun Ma)

60 APPLIED LIFE SCIENCES↗

SU-E-T-314: Dosimetric Effect of Smooth Drilling On Proton Compensators in Prostate Patients

Purpose: To evaluate the dosimetric effect of smooth drilling of proton compensators in proton prostate plans when compared to typical plunge drilling settings. Methods: Twelve prostate patients were planned in Eclipse treatment planning system using three different drill settings Smooth, Plunge drill A, and Plunge drill B. The differences between A and B were: spacing X[cm]: 0.4(A), 0.1(B), spacing Y[cm]: 0.35(A), 0.1(B), row offset [cm]: 0.2(A), 0(B). Planning parameters were kept consistent between the different plans, which utilized two opposed lateral beams arrangement. Mean differences absolute dosimetry in OAR constraints are presented. Results: The smooth drilled compensator based plans yielded equivalent target coverage to the plans generated with drill settings A and B. Overall, the smooth compensators reduced dose to the majority of organs at risk compared to settings A and B. Constraints were reduced for the following OAR: Rectal V75 by 2.12 and 2.48%, V70 by 2.45 and 2.91%, V65 by 2.85 and 3.37%, V50 by 2.3 and 5.1%, Bladder V65 by 4.49 and 3.67%, Penial Bulb mean by 3.7 and 4.2Gy, and the maximum plan dose 5.3 and 7.4Gy for option A vs smooth and option B vs smooth respectively. The femoral head constraint (V50<5%) was met by all plans, but it was not consistently lower for the smooth drilling plan. Conclusion: Smooth drilled compensators provide equivalent target coverage and overall slightly cooler plans to the majority of organs at risk; it also minimizes the potential dosimetric impacts caused by patient positioning uncertainty.

60 APPLIED LIFE SCIENCES↗

SU-E-T-315: Dosimetric Effects of Couch Top Shift On VMAT Delivery in Absence of Indexing

Purpose: To investigate dosimetric effects of couch top shift for volumetric-modulated arc therapy (VMAT) in absence of indexing of immobilization devices. Methods: A total of twelve VMAT treatment plans were selected from three regions (lung, abdomen, and pelvis) to account for the variation of the patient position relative to the couch top. The treatment plans were generated using the Varian Eclipse system. A pinpoint ionization chamber (PTW TN31014) was placed at the center of 16-cm solid water phantom and the dose was delivered using the Varian TrueBeam STx with BrainLAB ExacTrac couch top. To simulate the day-to-day variation of the patient position relative to couch top, the couch top was laterally shifted up to 50 mm, with an increment of 5 mm from 0 to 20 mm; and of 10 mm afterwards, and the phantom was moved back to 0 cm shift for measurement. The dose was also delivered using a Varian tennis racket grid insert at 0 cm shift to simulate the absence of couch top. The treatment plans were delivered with 6, 10, and 15 MV photons using the same leaf sequencing to investigate the energy dependence of couch top shift. The dose difference was normalized to 0 cm shift for the regular couch top for comparison. Results: The percent difference of dose was found to increase with lateral shift for all energies; however, the average differences were close to 0% and the maximum difference was within 1% along the lateral shifts. The differences with the absence of couch top were 2.2±0.5% (6MV), 1.7±0.3% (10MV), and 1.6±0.2% (15MV), respectively. Conclusion: The inclusion of couch top is recommended in treatment planning to minimize the dosimetric uncertainty between calculated and delivered dose even in absence of indexing of immobilization devices in VMAT delivery.

60 APPLIED LIFE SCIENCES↗

SU-E-T-318: Dosimetric Evaluation of ArcCHECK and 3DVH System Using Customized Polymer Gel Dosimeter

Purpose: ArcCHECK and 3DVH system (Sun Nuclear) can reconstruct the three-dimensional (3D) dose distribution and provide the DVH analysis in a patient. The aim of this study was to evaluate dosimetric accuracy of this system using customized polymer gel dosimeter, and also Gafchromic EBT3 films. Methods: Polyacrylamide-based gel contained magnesium chloride as a sensitizer (iPAGAT) was used in this study. Volumetric-modulated arc therapy (VMAT) plan was performed for the C-shape structure by the Eclipse treatment planning system (Varian) and used to irradiate the ArcCHECK by the Novalis Tx linear accelerator (Varian/BrainLAB). The cubic phantom filled with iPAGAT and EBT3 films placed in three orthogonal planes (axial, sagittal, and coronal) inserted into the I’mRT Phantom (IBA Dosimetry) simulated a patient were irradiated with the same VMAT plan. The measurement-guided 3D dose distribution was reconstructed using 3DVH software from the measured data of the ArcCHECK. The 3D dose distribution in iPAGAT was read out by Signa 1.5 T MRI system (GE), and 2D dose distribution on EBT3 was read out by color scanner (Epson). The comparison of all the dose distributions was performed with dose profiles and gamma index analysis in orthogonal planes using in-house developed software. Results: A good agreement was observed by overlaying the dose profiles of 3DVH, EBT3, and iPAGAT. The mean pass rates by gamma index analysis with 3%/3 mm criteria in orthogonal planes were 94.3% (3DVH vs EBT3), 91.1% (3DVH vs iPAGAT), and 96.4% (iPAGAT vs EBT3), respectively. Conclusion: 3D dose distribution reconstructed by ArcCHECK and 3DVH system was estimated accurately in a patient. However, slightly differences were observed between 3DVH and iPAGAT because of MRI noise, therefore further study is required to improve the accuracy of MRI based polymer gel dosimetry for the DVH analysis.

60 APPLIED LIFE SCIENCES↗

SU-E-T-319: Dosimetric Evaluation of IMRT with Mix-Energy Beam for Deep Seated Targets

Purpose: IMRT is preferred in the range of 6–10MV X-rays. Partially adding high energy (>10MV) treatment fields, may provide advantage of both higher and lower energies. To study IMRT dose distribution obtained from treatment plans with single (6MV) and mixed-energy (6MV and 15MV) for deep seated targets (separation more than 30cm). Methods: Five patients of carcinoma of cervix were studied using eclipse planning system. Two different dynamic IMRT plans were generated for Varian CL2300C/D linear accelerator; one is by using 6MV X-ray with seven equally spaced coplanar beams. In second plan, 2 lateral oblique fields (gantry angle 102°, 255°) beam energy was modified to 15MV by keeping all other parameters and dose volume constraints constant. Dose prescription for the planning target volume (PTV) was (5040cGy/28f). For plan comparison, dose volume histogram (DVH) was used and PTV coverage index (CI=Target volume covered by prescription dose/Target volume), heterogeneity index (D5/D95), mean dose to organ at risk (OAR) and normal tissue integral dose (NTID, liter-Gray) was also noted. Total monitor unit (MU) required to deliver a plan was also noted. Results: Mixed-energy plan showed a better conformity and CI values were 0.942±0.032 and 0.960±0.040 for single-energy and mixed-energy plan, respectively. In addition, HI value of mixed energy beam is comparable to that of single energy and the values were within 1.084±0.034 and 1.082±0.032 for single energy and mixed-energy plan, respectively. Variation in mean dose to bladder, rectum and bowel were within 1.05%, 0.87% and 0.90%. NTID was lesser for mixed-energy beam due to use of two high-energy fields. NTID were 1573.40±214.60 and 1510.20±249.80 litre-Gray for single energy and mixed-energy plan. MU needed to deliver a plan was similar in both plans and MUs were 238±45 and 237±47. Conclusion: Partial use of 15MV treatment fields in IMRT plan for deep seated targets showed dosimetric advantage over 6MV plan.

60 APPLIED LIFE SCIENCES↗

SU-E-T-328: Dosimetric Impact of Cobalt-Chrome Stabilization Hardware in Paraspinal Radiation Therapy

Purpose: Due to saturation, high density materials Result in an apparent density of 3.2 g/cm{sup 3} in CT images. The true density of traditional titanium stabilization rods (∼4.4 g/cm{sup 3}) is typically ignored in treatment planning. This may not be acceptable for new cobalt-chrome rods with a density of 8.5 g/cm{sup 3}. This study reports the dosimetric impact of cobalt-chrome rods in paraspinal radiotherapy. Methods: For titanium and cobalt-chrome rods, two planning studies were done for both IMRT and VMAT in Varian Eclipse using AAA. 1) The effect of planning without assigning the true rod density was assessed by comparing plans generated with the apparent density and recalculated with the true density for titanium and cobalt-chrome. 2) To test if TPS can compensate for high density rods during optimization. Furthermore, TPS calculation accuracy was verified using MapCheck for a single 20 x 10 cm{sup 2} field. The MapCheck was incrementally shifted to achieve measurement resolution of 1 mm. Results: PTV coverage was ∼0.3% and ∼4.7% lower in plans that were recalculated with the true rod density of titanium and cobalt-chrome, respectively. PTV coverage can be maintained if the correct density is used in optimization. Measurements showed that TPS overestimated the dose locally by up to 11% for cobalt-chrome rods and up to 4% for titanium rods if the density is incorrect. With density corrected, maximum local differences of 6% and 3% were seen for cobalt-chrome and titanium rods, respectively. At 2 cm beneath a rod, electrons scattered from the side of the rod increased the lateral dose and diminished as depth increases. TPS was not able to account for this effect properly even with the true rod density assigned. Conclusion: Neglecting the true density of cobalt-chrome rods can cause under coverage to the PTV. Assigning the correct density during treatment planning can minimize unexpected decrease in PTV dose.

60 APPLIED LIFE SCIENCES↗

SU-E-T-332: Dosimetric Impact of Photon Energy and Treatment Technique When Knowledge Based Auto-Planning Is Implemented in Radiotherapy of Localized Prostate Cancer

Purpose: The aim of this study was to investigate the dosimetric impact of the combination of photon energy and treatment technique on radiotherapy of localized prostate cancer when knowledge based planning was used. Methods: A total of 16 patients with localized prostate cancer were retrospectively retrieved from database and used for this study. For each patient, four types of treatment plans with different combinations of photon energy (6X and 10X) and treatment techniques (7-field IMRT and 2-arc VMAT) were created using a prostate DVH estimation model in RapidPlan™ and Eclipse treatment planning system (Varian Medical System). For any beam arrangement, DVH objectives and weighting priorities were generated based on the geometric relationship between the OAR and PTV. Photon optimization algorithm was used for plan optimization and AAA algorithm was used for final dose calculation. Plans were evaluated in terms of the pre-defined dosimetric endpoints for PTV, rectum, bladder, penile bulb, and femur heads. A Student’s paired t-test was used for statistical analysis and p > 0.05 was considered statistically significant. Results: For PTV, V95 was statistically similar among all four types of plans, though the mean dose of 10X plans was higher than that of 6X plans. VMAT plans showed higher heterogeneity index than IMRT plans. No statistically significant difference in dosimetry metrics was observed for rectum, bladder, and penile bulb among plan types. For left and right femur, VMAT plans had a higher mean dose than IMRT plans regardless of photon energy, whereas the maximum dose was similar. Conclusion: Overall, the dosimetric endpoints were similar regardless of photon energy and treatment techniques when knowledge based auto planning was used. Given the similarity in dosimetry metrics of rectum, bladder, and penile bulb, the genitourinary and gastrointestinal toxicities should be comparable among the selections of photon energy and treatment techniques.

60 APPLIED LIFE SCIENCES↗

SU-E-T-341: DVH-Based Comparison of True 3D Measurements to a Delta4 System

Purpose: Delta4 dosimetric software can be used to calculate DVH-based metrics for patient-specific quality assurance from measurements made by a Delta4 QA device. This study investigates the effectiveness of a novel transform method that transposes measurements made with a full-density 3D dosimeter onto patient anatomy, enabling the calculation of DVHs. This allows for DVH comparisons from the transformed dose distribution, which are based on true 3D measurements, to those from the Delta4 system, which are based on semi-3D measurements and interpolation. Methods: A double-arc VMAT treatment for a head-and-neck case was delivered to a 1kg PRESAGE 3D dosimeter inserted into a polyurethane head phantom. The dosimeter was readout using an in-house optical-CT scanner to gather full-density 3D dosimetric data. The transform method is achieved by multiplication of the measured doses with a “transformation matrix” which accounts for heterogeneities and differences in geometry between the patient and the phantom. The transformation matrix is a voxel-by-voxel division of the patient planned dose by the phantom planned dose, both calculated in the treatment planning system (Eclipse). The transformed distribution was then overlaid on the patient CT data, enabling the calculation of DVHs. The same VMAT treatment was delivered to the Delta4 phantom and DVH data was calculated using its associated software. Results: The transformed dose distribution showed good agreement with calculated patient values, determined by similarity in dose profiles between the two distributions and a 3D gamma index passing rate of 94.87% for 3%/3mm criteria. For every structure contained within the dosimeter volume, the transformed DVHs demonstrated better agreement than the Delta4 DVHs, when compared to the values calculated in the treatment planning system. Conclusion: The coupled technique of full-density 3D dose measurements and the presented transform method enables clinical patient-specific quality assurance data that is more accurate than the semi-3D Delta4 system. This work was supported by NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

SU-E-T-346: Effect of Jaw Position On Dose to Critical Structures in 3-D Conformal Radiotherapy Treatment of Pancreatic Cancer

Purpose: Three-dimensional conformal therapy remains a valid and widely used modality for pancreatic radiotherapy treatment. It usually meets dose constraints on critical structures. However, careful positioning of collimation jaws can reduce dose to the critical structures. Here we investigate the dosimetric effect of jaw position in MLC-based 3-D conformal treatment planning on critical structures. Methods: We retrospectively selected seven pancreatic cancer patients treated with 3-D conformal radiotherapy. We started with treatment plans (Varian Truebeam LINAC, Eclipse TPS, AAA, 18MV) having both x and y jaws aligned with the farthest extent of the block outline (8mm around PTV). Then we subsequently moved either both x-jaws or all x and y jaws outwards upto 3 cm in 1 cm increments and investigated their effect on average and maximum dose to neighboring critical structures keeping the same coverage to treatment volume. Results: Lateral displacement of both x-jaws by 1cm each increased kidney and spleen mean dose by as much as 1.7% and 1.3% respectively and superior inferior displacement increased liver, right kidney, stomach and spleen dose by as much as 2.1%, 2%, 5.2% and 1.6% respectively. Displacement of all x and y-jaws away by 1cm increased the mean dose to liver, right kidney, left kidney, bowels, cord, stomach and spleen by as much as 4.9%, 5.9%, 2.1%, 2.8%, 7.4%, 10.4% and 4.2% respectively. Percentage increase in mean dose due to 2 and 3cm jaw displacement increased almost linearly with the displaced distance. Changes in maximum dose were much smaller (mostly negligible) than the changes in mean dose. Conclusion: Collimation jaw position affects dose mostly to critical structures adjacent to it. Though treatment plans with MLCs conforming the block margin usually meet dose constraints to critical structures, keeping jaws all the way in, to the edge of the block reduces dose to the critical structures during radiation treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-356: Efficient Segmentation of Flattening Filter Free Photon Beamsfor 3D-Conformal SBRT Treatment Planning

Purpose: It has been argued that a 3D-conformal technique (3DCRT) is suitable for SBRT due to its simplicity for non-coplanar planning and delivery. It has also been hypothesized that a high dose delivered in a short time can enhance indirect cell death due to vascular damage as well as limiting intrafraction motion. Flattening Filter Free (FFF) photon beams are ideal for high dose rate treatment but their conical profiles are not ideal for 3DCRT. The purpose of our work is to present a method to efficiently segment an FFF beam for standard 3DCRT planning. Methods: A 10×10 cm Varian True Beam 6X FFF beam profile was analyzed using segmentation theory to determine the optimum segmentation intensity required to create an 8 cm uniform dose profile. Two segments were automatically created in sequence with a Varian Eclipse treatment planning system by converting isodoses corresponding to the calculated segmentation intensity to contours and applying the “fit and shield” tool. All segments were then added to the FFF beam to create a single merged field. Field blocking can be incorporated but was not used for clarity. Results: Calculation of the segmentation intensity using an algorithm originally proposed by Xia and Verhey indicated that each segment should extend to the 92% isodose. The original FFF beam with 100% at the isocenter at a depth of 10 cm was reduced to 80% at 4cm from the isocenter; the segmented beam had +/−2.5 % uniformity up to 4.4cm from the isocenter. An additional benefit of our method is a 50% decrease in the 80%-20% penumbra of 0.6cm compared to 1.2cm in the original FFF beam. Conclusion: Creation of two optimum segments can flatten a FFF beam and also reduce its penumbra for clinical 3DCRT SBRT treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-358: Empirical Beam Angle Optimization for Lung Cancer Intensity Modulated Radiation Therapy

Purpose: Creating an improved BAO can decrease the amount of time a dosimetrist spends on making a treatment plan, improve the treatment quality and enhance the tools an inexperienced dosimetrist can use to develop planning techniques. Methods: Using empirical data created by experienced dosimetrists from 69 patients treated for lung cancer, the most frequently used gantry angles were applied to four different regions in each lung to gather an optimal set of fields that could be used to treat future lung cancer patients. This method, given the moniker FAU BAO, is compared in 7 plans created with the Eclipse BAO choosing 5 fields and 9 fields. Results: The results show that the conformality index improved by 30% or 3% when using the 5 and 9 fields. The conformation number was better by 12% from the 5 fields and 9% from the 9 fields. The organs at risk (OAR) were overall more protected to produce fewer nonstochastic effects from the radiation treatment with the FAU BAO. Conclusion: Empirical methods for beam angle optimization is a viable method for IMRT treatment planning techniques.

60 APPLIED LIFE SCIENCES↗

SU-E-T-367: Evaluate the Dosimetric Impacts On Patient Specific Treatment Plans Due to Set Up Uncertainties During LINAC Annual QA and Commission

Purpose: To quantify the dosimetric impact on patient’s specific treatment plans due to set up uncertainties during LINAC commission and annual QA and to determine the maximum set up uncertainty allowance range. Methods: A 60×60×60 cm{sup 3} solid water cube was created in Varian Eclipse TPS. Beam data profiles (crossline and diagonal) and PDDs for field sizes ranging from 2×2 cm{sup 2} to 40×40 cm{sup 2} were simulated. Three main uncertainty scenarios were purposely introduced for gantry position tilts (0–5°), source axis distance changes (100–105 cm), and iso-center position shifts (0–5 mm) during the simulation. A gamma analysis was used to compare the correct simulated profiles with the profiles for each scenario. Two static IMRT treatment plans (H&N and GYN) with tumors at 5 cm and 15 cm depths were compared using similar set up uncertainties. Results: A gamma analysis using ±3%/±3mm with 90% passing rate criteria is included to show the passing rate for each scenario. Crossline and diagonal profiles showed a gamma passing rating of ≥ 90% at depth ≤10 cm for these scenarios: gantry tilted from 0–5°, SAD changed from 100–105 cm, and iso-center shifted ≤ 4 mm. From 10 to 20 cm depths, all three scenarios failed with gamma passing ≤ 90% excepted for diagonal profiles at Gantry =2°, SAD =1 cm, and iso-center =1 mm off center. Diagonal profiles showed a higher gamma passing rating compared to crossline profiles for all three scenarios. PDD differences also increased as depth increased. For patient’s specific treatment plans, maximum uncertainties allowed to obtain a ≥90% gamma passing rating are: gantry tilts ±1 degree, SAD shifts ±2 cm, and iso-center moves ±3 mm. Conclusion: This study validated AAPM TG 142 recommendations on the mechanical and dosimetry uncertainties and provided proofs on maximum acceptance tolerances for LINAC annual QA and commission.

60 APPLIED LIFE SCIENCES↗