Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diameter distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Observations of the quiet sun at meter and decameter wavelengths

The new TeePee Tee array of the Clark Lake Radio Observatory has been used to observe the quiet sun at 121.5, 73.8 and 26.3 MHz. The equatorial brightness distributions at all three frequencies, and the polar brightness distributions at the two higher ones have been measured. From the observed total fluxes and half-power diameters we have derived the peak brightness temperatures of the solar disk as well as of some sources of the slowly varying component.

Kundu, M. R.↗

A 50 cm diameter annular ion engine

An ion engine design is presented which uses an annular geometry as a means of achieving large engine diameters and hence, high thrust levels. Preliminary results are discussed for discharge-only operation of a 50-cm-diameter annular ion engine. Measured operating parameters presented include discharge current and voltage characteristics, discharge chamber ion current distribution, engine body temperatures, plasma flatness parameter effects and total integrated grid ion current.

Aston, Graeme↗

The Solar System Beyond Neptune

The aim of this research is to study the objects in the Kuiper Belt, in order to understand the nature of its origin and the evolutionary processes which have affected the Kuiper Belt. Particular science objectives include: 1) the determination of the sky-plane surface density of Kuiper Belt Objects (KBOs); 2) the determination of the slope of the cumulative luminosity function (CLF); 3) the determination of the KBO size distribution; 4) the isolation of bright KBOs from which physical measurements can be secured using existing 10-meter diameter class telescopes; 5) physical measurements of bright KBOs designed to assess their composition. Major results obtained under the grant include: 1) The determination of the surface density of KBOs (objects per square degree of sky) as a function of apparent red magnitude in the range 21 less than MR less than 24.8. 2) The discovery of a new dynamical class in the Kuiper Belt, exemplified by 1996 TL66. 3) Physical observations of two bright KBOs were secured using the Keck 10-meter telescope and an infrared imager/spectrometer; 4) In support of public interest in the Kuiper Belt, we wrote a popular article for Scientific American magazine and we developed a "Kuiper Belt Home Page" on the world-wide web.

Jewitt, David↗

The Phanerozoic Impact Cratering Rate: Evidence from the Farside of the Moon

The relatively recent (< 1 b.y.) flux of asteroids and comets forming large craters on the Earth and Moon may be accurately recorded by craters with bright rays on the Moon's farside. Many previously unknown farside rayed craters are clearly distinguished in the low-phase-angle images returned by the Clementine spacecraft. Some large rayed craters on the lunar nearside are probably significantly older than 1 Ga; rays remain visible over the maria due to compositional contrasts long after soils have reached optical maturity. Most of the farside crust has a more homogeneous composition and only immature rays are visible. The size-frequency distribution of farside rayed craters is similar to that measured for Eratosthenian craters (up to 3.2 b.y.) at diameters larger than 15 km. The areal density of farside rayed craters matches that of a corrected tabulation of nearside Copernican craters. Hence the presence of bright rays due to immature soils around large craters provides a consistent time-stratigraphic basis for defining the base of the Copernican System. The density of large craters less than approximately 3.2 b.y. old is approximately 3.2 times higher than that of large farside rayed craters alone. This observation can be interpreted in two ways: (1) the average cratering rate has been constant over the past 3.2 b.y. and the base of the Copernican is approximately 1 Ga, or (2) the cratering rate has increased in recent geologic time and the base of the Copernican is less than 1 Ga. We favor the latter interpretation because the rays of Copernicus (800-850 m.y. old) appear to be very close to optical maturity, suggesting that the average Copernican cratering rate was approximately 35% higher than the average Eratosthenian rate. Other lines of evidence for an increase in the Phanerozoic (545 Ga) cratering rate are (1) the densities of small craters superimposed on Copernicus and Apollo landing sites, (2) the rates estimated from well-dated terrestrial craters (< 120 m.y.) and from present-day astronomical observations, and (3) the Proterozoic rate suggested by the crater record of Australia. The hypothesis most consistent with several key observations is that the cratering rate has increased by approximately 2x during the past approximately 300 m.y..

McEwen, Alfred S.↗

Distribution of Large Visible and Buried Impact Basins on Mars: Comparison with Free-Air Gravity, Crustal Thickness and Magnetization Models

A comparison of the distribution of visible and buried impact basins (Quasi-Circular Depressions or QCDs) on Mars > 200 km in diameter with free air gravity, crustal thickness and magnetization models shows some QCDs have coincident gravity anomalies but most do not. Very few QCDs have closely coincident magnetization anomalies, and only the oldest of the very large impact basins have strong magnetic anomalies within their main rings. Crustal thickness data show a large number of Circular Thinned Areas (CTAs). Some of these correspond to known impact basins, while others may represent buried impact basins not always recognized as QCDs in topography data alone. If true, the buried lowlands may be even older than we have previously estimated.

Frey, H. V.↗

Nanolaminate Mirrors With "Piston" Figure-Control Actuators

Efforts are under way to develop a special class of thin-shell curved mirrors for high-resolution imaging in visible and infrared light in a variety of terrestrial or extraterrestrial applications. These mirrors can have diameters of the order of a meter and include metallic film reflectors on nanolaminate substrates supported by multiple distributed piezoceramic gpiston h-type actuators for micron-level figure control. Whereas conventional glass mirrors of equivalent size and precision have areal mass densities between 50 and 150 kg/sq m, the nanolaminate mirrors, including not only the reflector/ shell portions but also the actuators and the backing structures needed to react the actuation forces, would have areal mass densities that may approach .5 kg/m2. Moreover, whereas fabrication of a conventional glass mirror of equivalent precision takes several years, the reflector/shell portion of a nanolaminate mirror can be fabricated in less than a week, and its actuation system can be fabricated in 1 to 2 months. The engineering of these mirrors involves a fusion of the technological heritage of multisegmented adaptive optics and deformable mirrors with more recent advances in metallic nanolaminates and in mathematical modeling of the deflections of thin, curved shells in response to displacements by multiple, distributed actuators. Because a nanolaminate shell is of the order of 10 times as strong as an otherwise identical shell made of a single, high-strength, non-nanolaminate metal suitable for mirror use, a nanolaminate mirror can be made very thin (typically between 100 and 150 m from the back of the nanolaminate substrate to the front reflecting surface). The thinness and strength of the nanolaminate are what make it possible to use distributed gpiston h-type actuators for surface figure control with minimal local concentrated distortion (called print-through in the art) at the actuation points.

Lowman, Andrew↗

Estimating the Concentration of Large Raindrops from Polarimetric Radar and Disdrometer Observations

Estimation of rainfall integral parameters, including radar observables, and empirical relations between them are sensitive to the truncation of the drop size distribution (DSD), particularly at the large drop end. The sensitivity of rainfall integral parameters to the maximum drop diameter (D(sub max)) is exacerbated at C‐band since resonance effects are pronounced for large drops in excess of 5 mm diameter (D). Due to sampling limitations, it is often difficult to reliably estimate D(sub max) with disdrometers. The resulting uncertainties in D(sub max0 potentially increase errors in radar retrieval methods, particularly at C‐band, that rely on disdrometer observations for DSD input to radar models. In fact, D(sub max) is typically an assumed DSD parameter in the development of radar retrieval methods. Because of these very uncertainties, it is difficult to independently confirm disdrometer estimates of D(sub max) with polarimetric radar observations. A couple of approaches can be taken to reduce uncertainty in large drop measurement. Longer integration times can be used for the collection of larger disdrometer samples. However, integration periods must be consistent with a radar resolution volume (RRV) and the temporal and spatial scales of the physical processes affecting the DSD therein. Multiple co‐located disdrometers can be combined into a network to increase the sample size within a RRV. However, over a reasonable integration period, a single disdrometer sample volume is many orders of magnitudes less than a RRV so it is not practical to devise a network of disdrometers that has an equivalent volume to a typical RRV. Since knowledge of DSD heterogeneity and large drop occurrence in time and space is lacking, the specific accuracy or even general representativeness of disdrometer based D(sub max) and large drop concentration estimates within a RRV are currently unknown. To address this complex issue, we begin with a simpler question. Is the frequency of occurrence of large rain drops (D > 5 mm) in disdrometer observations, either stand alone or networked, generally representative and consistent with polarimetric radar observations? We first show from simulations that the concentration of large (D > 5 mm) rain drops (N(sub T5)) can be estimated from polarimetric observations of specific differential phase (K(sub dp)) and differential reflectivity (Z(sub dr)), N(sub T5)=F(K(sub dp),Z(sub dr)), or horizontal reflectivity (Z(sub h)) and Z(sub dr), N(sub T5)=(Z(sub h),Z(sub dr)). We assess the error associated with polarimetric retrieval of N(sub T5), including sensitivity to D(sub max) parameterization assumptions and measurement error in the radar simulations. Polarimetric measurements at S‐band and C‐band will then be used to retrieve estimates of N(sub T5) and compared to disdrometer estimates of N(sub T5). After careful consideration of retrieval error, we will check consistency between disdrometer and polarimetric radar estimates of N(sub T5) and the frequency of occurrence of large rain drops in a variety of precipitating regimes using data from NASA's Global Precipitation Measurement (GPM) Ground Validation (GV) program, including field campaigns such as MC3E (Oklahoma) and IFloodS (Iowa) and extended measurements over Huntsville, Alabama and NASA Wallops Flight Facility in coastal Virginia.

Carey, Lawrence D.↗

Boulders on Ceres

Introduction: In December 2015 the Dawn spacecraft moved into the Low Altitude Mapping Orbit (LAMO) around Ceres, encircling the dwarf planet at a distance of 400 km to the surface below. At this altitude, images of the on-board framing camera have a resolution of 36 meters per pixel, high enough to distinguish large boulders on the surface. Indeed, LAMO images show a multitude of boulders around what seem to be fresh craters. The average life-time of boulders on Dawn's previous target, Vesta, was estimated to be similar to that of Lunar boulders, as may be expected from the basaltic surface composition. The bulk composition of Ceres may be carbonaceous chondrite-like with significant contributions of clays, salt, and water ice. As such, the abundance and distribution of boulders on Ceres may be different from that on Vesta. We mapped, counted, and measured the diameter of boulders over the entire surface of Ceres. Our analysis of the data in combination with crater age estimates may provide clues to the physical nature and composition of the surface.

Ceres↗

Measuring Shock Stage of ltokawa Regolith Grains by Electron Back-Scattered Diffraction and Synchrotron X-Ray Diffraction

We have been analyzing Itokawa samples in order to definitively establish the degree of shock experienced by the regolith of asteroid Itokawa, and to devise a bridge between shock determinations by standard light optical petrography, crystal structures as determined by electron and X-ray diffraction techniques. We are making measurements of olivine crystal structures and using these to elucidate critical regolith impact processes. We use electron back-scattered diffraction (EBSD) and synchrotron X-ray diffraction (SXRD). We are comparing the Itokawa samples to L and LL chondrite meteorites chosen to span the shock scale experienced by Itokawa, specifically Chainpur (LL3.4, Shock Stage 1), Semarkona (LL3.00, S2), Kilabo (LL6, S3), NWA100 (L6, S4) and Chelyabinsk (LL5, S4). In SXRD we measure the line broadening of olivine reflections as a measure of shock stage. In this presentation we concentrate on the EBSD work. We employed JSC's Supra 55 variable pressure FEG-SEM and Bruker EBSD system. We are not seeking actual strain values, but rather indirect strain-related measurements such as extent of intra-grain lattice rotation, and determining whether shock state "standards" (meteorite samples of accepted shock state, and appropriate small grain size) show strain measurements that may be statistically differentiated, using a sampling of particles (number and size range) typical of asteroid regoliths. Using our system we determined that a column pressure of 9 Pa and no C-coating on the sample was optimal. We varied camera exposure time and gain to optimize mapping performance, concluding that 320x240 pattern pixilation, frame averaging of 3, 15 kV, and low extractor voltage yielded an acceptable balance of hit rate (>90%), speed (11 fps) and map quality using an exposure time of 30 ms (gain 650). We found that there was no strong effect of step size on Grain Orientation Spread (GOS) and Grain Reference Orientation Deviation angle (GROD-a) distribution; there was some effect on grain average Kernel Average Misorientation (KAM) (reduced with smaller step size for the same grain), as expected. We monitored GOS, Maximum Orientation Spread (MOS) and GROD-a differences between whole olivine grains and sub-sampled areas, and found that there were significant differences between the whole grain dataset and subsets, as well as between subsets, likely due to sampling-related "noise". Also, in general (and logically) whole grains exhibit greater degrees of cumulative lattice rotation. Sampling size affects the apparent strain character of the grain, at least as measured by GOS, MOS and GROD-a. There were differences in the distribution frequencies of GOS and MOS between shock stages, and in plots of MOS and GOS vs. grain diameter. These results are generally consistent with those reported this year. However, it is unknown whether the differences between samples of different shock states exceeds the clustering of these values to the extent that shock stage determinations can still be made with confidence. We are investigating this by examination of meteorites with higher shock stage 4 to 5. Our research will improve our understanding of how small, primitive solar system bodies formed and evolved, and improve understanding of the processes that determine the history and future of habitability of environments on other solar system bodies. The results will directly enrich the ongoing asteroid and comet exploration missions by NASA and JAXA, and broaden our understanding of the origin and evolution of small bodies in the early solar system, and elucidate the nature of asteroid and comet regolith.

Zolensky, Michael↗

500+ Million Years of Volcanism in Australe

The roughly circular collection of mare deposits in the "Mare Australe" region (38.9°S, 93°E) is ~900 km in diameter. The maria erupted into post-basin impact craters but are generally disconnected from each other. The distribution of maria could reflect what might have been the early stages of other basin filling mare eruptions, but which are preserved in Australe and some farside locations [1-3]. Topographic data fail to indicate a 900-km basin, but gravity and topographic data suggest a 600-km basin in the northern part of Australe [6]. The relationship between the basin and the wider-spread mare deposits is unclear, particularly outside the basin. We utilized images, gravity, topography, and composition to investigate the timing of volcanism in "Mare Australe" to interpret the evolution of magmatism in Australe and how it might relate to other mare sources. Humboldt crater (~3.6 Ga) makes an excellent stratigraphic marker that can be traced across much of the deposits and serves as a stratigraphic calibration for absolute model ages (AMAs) derived from crater size-frequency distributions (CSFDs). We found a range of AMAs from ~3.3 to 3.8 Ga in north Australe, similar to previous studies [4], and there is also evidence for multiple deposits of older cryptomaria. The age range, however, is narrower than for maria in other basins (e.g., Imbrium and South Pole-Aitken [4-5]), suggesting different magmatism in Australe. Most of the mare deposits are >3.5 Ga; younger deposits are co-located in the north basin. The basin may have provided additional pathways for rising magma to the surface over time. We also found evidence of a several interconnected deposits within the north basin. Other, smaller deposits, however, clearly show distinct age differences between units within a single topographic depression (e.g., Lyot crater) and likely represent discrete eruptions. Additionally, there are no floor fractured craters other than Humboldt [6], suggesting that magma generally did not stall out near the surface, also consistent with gravity and (lack of) magnetic anomalies (in contrast to Marius Hills and South Pole-Aitken basin [7-8]).

Julie Dawn Stopar↗

JWST Sighting of Decameter Main-Belt Asteroids and View on Meteorite Sources

Asteroid discoveries are essential for planetary-defense efforts aiming to prevent impacts with Earth, including the more frequent megaton explosions from decameter impactors. While large asteroids (≥100 km) have remained in the main belt since their formation, small asteroids are commonly transported to the near-Earth object (NEO) population. However, due to the lack of direct observational constraints, their size-frequency distribution — which informs our understanding of the NEOs and the delivery of meteorite samples to Earth —varies significantly among models. Here, we report 138 detections of the smallest asteroids (⪆10 m) ever observed in the main belt, which were enabled by JWST’s infrared capabilities covering the asteroids’ emission peaks and synthetic tracking techniques. Despite small orbital arcs, we constrain the objects’ distances and phase angles using known asteroids as proxies, allowing us to derive sizes via radiometric techniques. Their size-frequency distribution exhibits a break at∼100 m (debiased cumulative slopes of q=−2.66±0.60 and−0.97±0.14 for diameters smaller and larger than∼100 m, respectively), suggestive of a population driven by collisional cascade. These asteroids were sampled from multiple asteroid families —most likely Nysa, Polana and Massalia — according to the geometry of pointings considered here. Through additional long-stare infrared observations, JWST is poised to serendipitously detect thousands of decameter-scale asteroids across the sky, probing individual asteroid families and the source regions of meteorites “in-situ”.

asteroid families↗

Large scale synthesis of resorcinol-formaldehyde aerogel

A product includes an aerogel having a single bulk structure, the single bulk structure having at least one dimension greater than 10 millimeters. The single bulk structure includes a plurality of pores, where each pore has a largest diameter defined as a greatest distance between pore walls of the respective pore. In addition, an average of the largest diameters of a majority of the pores is within a specified range, and the plurality of pores are distributed substantially homogenously throughout the single bulk structure.

Loeb, Colin↗

Synthesis and luminescence of CePO4:Tb/LaPO4 core/sheath nanowires

CePO4:Tb/LaPO4 core/sheath architectured nanowires have been successful synthesized by a facile aqueous chemical method mediated by original CePO4:Tb aggregation seeds. The seed crystals serve as both a luminescence center and nucleation site for epitaxial growth. The seed nanocrystals have irregular sphere-like shape with an average size of around 6.8 nm and a narrow size distribution. When the seed crystals are coated with LaPO4, the resulting CePO4:Tb/LaPO4 core/sheath architectured nanowires have mean diameters of about 7.6 nm and lengths up to 331 nm. Both the photo- and X-ray luminescence demonstrate that the LaPO4 coating increases the luminescence efficiency. These core-sheath structured nanowires may find potential applications in solid state lighting, medical imaging and radiation detection.

Li, Yuebin↗

Development of a facility for high-precision irradiation of cells with carbon ions

Purpose: Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed {+-}1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. Methods: A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. Results: The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing the irradiation of cell samples with the specified accuracy. Measurements of the transverse and longitudinal dose distribution showed that the dose variation over the sample volume was {+-}0.8% and {+-}0.7% in the lateral and longitudinal directions, respectively. The track-averaged LET of 132{+-}10 keV/{mu}m and dose-averaged LET of 189{+-}15 keV/{mu}m at the position of the sample were obtained from a GEANT4 simulation, which was validated experimentally. Three separately measured cell-survival curves yielded nearly identical results. Conclusions: With the new facility, high-precision carbon-ion irradiations of biological samples can be performed with highly reproducible results.

60 APPLIED LIFE SCIENCES↗

Ultrasound-assisted facile synthesis of a new tantalum(V) metal-organic framework nanostructure: Design, characterization, systematic study, and CO{sub 2} adsorption performance

This work presents a fast route for the preparation of a new Ta(V) metal-organic framework nanostructure with high surface area, significant porosity, and small size distribution. X-ray diffraction (XRD), scanning electron microscopy (SEM), Transition electron microscopy (TEM), energy dispersive spectrometer (EDS), thermo-gravimetric analysis (TGA), differential scanning calorimetry (DSC), fourier transform infrared spectroscopy (FTIR), CHNS/O elemental analyser, and Brunauer-Emmett-Teller (BET) surface area analysis were applied to characterize the synthesized product. Moreover, the influences of ultrasonic irradiation including temperature, time, and power on different features of the final products were systematically studied using 2{sup k-1} factorial design experiments, and the response surface optimization was used for determining the best welding parameter combination. The results obtained from analyses of variances showed that ultrasonic parameters affected the size distribution, thermal behaviour, and surface area of Ta-MOF samples. Based on response surface methodology, Ta-MOF could be obtained with mean diameter of 55 nm, thermal stability of 228 °C, and high surface area of 2100 m{sup 2}/g. The results revealed that the synthesized products could be utilized in various applications such as a novel candidate for CO{sub 2} adsorption. - Graphical abstract: A facile route was used for fabrication of a new metal -organic framework based on tantalum nanostructures that have high surface area, considerable porosity, homogenous morphology, and small size distribution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

VLA mapping of 1.35 cm water emission from the Mars atmospheric limb

We report preliminary results of 1.35 cm spectral line observations, in which we employed the NRAO Very Large Array (VLA) interferometer to map the horizontal and vertical distributions of water vapor around the Mars atmospheric limb in early Dec. of 1990. The increased atmospheric pathlengths presented near the limb of Mars and the high angular resolution afforded by the VLA at centimeter wavelengths lead to a remarkably sensitive, remote measurement of water in the atmosphere of Mars. We achieve approximately 300 km horizontal resolution on Mars, operating in the C configuration of the VLA, when Mars was 17.3 inches in diameter. This allows us to resolve the latitudinal and diurnal variations in atmospheric water emission around the limb of Mars. We derive the vertical distribution of atmospheric water from observed pressure broadening in the spectrally resolved lineshapes. These observations, which consist of two eight-hour integrations obtained on Dec. 3-4 and Dec. 6-7, correspond to late winter in the Northern Hemisphere of Mars (L sub s = 344 degrees).

Clancy, R. T.↗

SU-F-T-477: Investigation of DEFGEL Dosimetry Using MRI

Purpose: The DEFGEL dosimeter/phantom allows for the measurement of 3D dose distributions while maintaining tissue equivalence and deformability. Although DEFGEL is traditionally read out with optical CT, the use of MRI would permit the measurement of 3D dose distributions in optically interfering configurations, like while embedded in a phantom. To the knowledge of the authors, this work is the first investigation that uses MRI to measure dose distributions in DEFGEL dosimeters. Methods: The DEFGEL (6%T) formula was used to create 1 cm thick, 4.5 cm diameter cylindrical dosimeters. The dosimeters were irradiated using a Varian Clinac 21EX linac. The MRI based transverse relaxation rate (R2) of the gel was measured in a central slice of the dosimeter with a Spin-Echo (SE) pulse sequence on a 3T GE SIGNA PET/MR scanner. The R2 values were fit to a monoexponential dose response equation using in-house software (MATLAB). Results: The data was well fit using a monoexponential fit for R2 as a function of absorbed dose (R{sup 2} = 0.9997). The fitting parameters of the monoexponential fit resulted in a 0.1229 Gy{sub −1}s{sub −1} slope. The data also resulted in an average standard deviation of 1.8% for the R2 values within the evaluated ROI. Conclusion: The close fit for the dose response curve shows that a DEFGEL based dosimeter can be paired with a SE MRI acquisition. The Type A uncertainty of the MRI method shows adequate precision, while the slope of the fit curve is large enough that R2 differences between different gel doses are distinguishable. These results suggest that the gel could potentially be used in configurations where an optical readout is not viable, such as measurements with the gel dosimeter positioned inside larger or optically opaque phantoms. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

SU-C-16A-04: Dosimetric Validation of a Partially-Shielded Gd-153 Brachytherapy Concept

Purpose: To demonstrate by measurement that using partially shielded Gd-153 sources for rotating-shield brachytherapy (RSBT) is feasible. RSBT is a potentially superior alternative to conventional high-dose-rate brachytherapy and provides the opportunity to dramatically improve tumor dose conformity for the treatment of, for example, prostate cancer. Methods: A custom-built, stainless steel encapsulated 150 mCi Gd-153 capsule with an outer length of 12.8 mm, outer diameter of 2.10 mm, active length of 9.98 mm, and active diameter of 1.53 mm was used. A partially shielded catheter was constructed with a 500 μm platinum shield and a 500 μm aluminum emission window, both with 180° azimuthal coverage. An acrylic phantom was constructed to measure the dose distributions from the shielded catheter in the transverse plane using Gafchromic EBT3 films. Film calibration curves were generated from 50, 70, and 100 kVp x-ray beams with NIST-traceable air kerma values to account for energy variation. Results: The transmission ratios of platinum to aluminum shielding at 1 cm off-axis are 7.5% and 7.6% for Monte Carlo (MCNP5) predicted and experimental results, respectively. The predicted/measured relative dose rates at 1 cm, 2 cm and 3 cm off-axis through the Al window were 100%/92.9%, 28.6%/27.0% and 13.8%/12.7%, respectively. Through the Pt shield, the predicted/measured relative dose rates were 7.5%/7.1%, 3.8%/3.0% and 2.4%/1.7%, respectively. Conclusion: Using partially-shielded Gd-153 sources for RSBT is a promising approach to improving brachytherapy dose distributions. The next step in making Gd-153 based RSBT a reality is developing a Gd-153 source that is small enough such that the source, shield, and catheter all fit within a 16 gauge needle, which has a 1.65 mm diameter. University of Iowa Research Foundation.

07 ISOTOPE AND RADIATION SOURCES↗