Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Crew Restraint Design for the International Space Station

With permanent human presence onboard the International Space Station (ISS), crews will be living and working in microgravity, dealing with the challenges of a weightless environment. In addition, the confined nature of the spacecraft environment results in ergonomic challenges such as limited visibility and access to the activity areas, as well as prolonged periods of unnatural postures. Without optimum restraints, crewmembers may be handicapped for performing some of the on-orbit tasks. Currently, many of the tasks on ISS are performed with the crew restrained merely by hooking their arms or toes around handrails to steady themselves. This is adequate for some tasks, but not all. There have been some reports of discomfort/calluses on the top of the toes. In addition, this type of restraint is simply insufficient for tasks that require a large degree of stability. Glovebox design is a good example of a confined workstation concept requiring stability for successful use. They are widely used in industry, university, and government laboratories, as well as in the space environment, and are known to cause postural limitations and visual restrictions. Although there are numerous guidelines pertaining to ventilation, seals, and glove attachment, most of the data have been gathered in a 1-g environment, or are from studies that were conducted prior to the early 1980 s. Little is known about how best to restrain a crewmember using a glovebox in microgravity. Another ISS task that requires special consideration with respect to restraints is robotic teleoperation. The Robot Systems Technology Branch at the NASA Johnson Space Center is developing a humanoid robot astronaut, or Robonaut. It is being designed to perform extravehicular activities (EVAs) in the hazardous environment of space. An astronaut located inside the ISS will remotely operate Robonaut through a telepresence control system. Essentially, the robot mimics every move the operator makes. This requires the operator to be stable enough to prevent inadvertent movements, while allowing the flexibility to accomplish the controlled movements of the robot. Some type of special purpose restraint will be required to operate Robonaut and similar devices.

Norris, Lena↗

Lunar Seismic Detector to Advance the Search for Strange Quark Matter

Detection of small seismic signals on the Moon are needed to study lunar internal structure and to detect possible signals from Strange Quark m&er transit events. The immediate objective is to create a prototype seismic detector using a tunnel diode oscillator with a variable capacitor attached to a proof mass. The device is designed to operate effectively on the Moon, which requires a low power consumption to operate through lunar night, while preserving sensitivity. The goal is capacitance resolution of better than 1 part in 10' and power consumption of less than 1 watt.

Galitzki, Nicholas B.↗

Blood Pressure Checker

An estimated 30 million people in the United States have high blood pressure, or hypertension. But a great many of them are unaware of it because hypertension, in its initial stages, displays no symptoms. Thus, the simply-operated blood pressure checking devices now widely located in public places are useful health aids. The one pictured above, called -Medimax 30, is a direct spinoff from NASA technology developed to monitor astronauts in space. For manned space flights, NASA wanted a compact, highly-reliable, extremely accurate method of checking astronauts' blood pressure without the need for a physician's interpretive skill. NASA's Johnson Space Center and Technology, Inc., a contractor, developed an electronic sound processor that automatically analyzes blood flow sounds to get both systolic (contracting arteries) and diastolic (expanding arteries) blood pressure measurements. NASA granted a patent license for this technology to Advanced Life Sciences, Inc., New York City, manufacturers of Medimax 30.

Source record↗

Technology and the Environment

Forest Service officials consulted NASA and found a solution in the application of laser technology originally developed for satellites. NASA/Goddard built a system called a "laser range pole," a portable battery operated back-packed device that allows direct sightings no matter how rough the intervening terrain or how thick the forest. The equipment consists of a laser transmitter and a receiver. From a given property marker, the transmitter pulses a laser beam vertically, several thousand feet in some cases. At a second surveying point about a mile away, the receiver detects the laser pulse high above the trees, and locks in on the exact direction. Thus provided a bearing between the two points, a ground crew can extend the border line back to the sending point by conventional surveying techniques.

Source record↗

High performance P-type thermoelectric materials and methods of preparation

The present invention is embodied in high performance p-type thermoelectric materials having enhanced thermoelectric properties and the methods of preparing such materials. In one aspect of the invention, p-type semiconductors of formula Zn.sub.4-x A.sub.x Sb.sub.3-y B.sub.y wherein 0.ltoreq.x.ltoreq.4, A is a transition metal, B is a pnicogen, and 0.ltoreq.y.ltoreq.3 are formed for use in manufacturing thermoelectric devices with substantially enhanced operating characteristics and improved efficiency. Two methods of preparing p-type Zn.sub.4 Sb.sub.3 and related alloys of the present invention include a crystal growth method and a powder metallurgy method.

Caillat, Thierry↗

High performance p-type thermoelectric materials and methods of preparation

The present invention is embodied in high performance p-type thermoelectric materials having enhanced thermoelectric properties and the methods of preparing such materials. In one aspect of the invention, p-type semiconductors of formula Zn4-xAxSb3-yBy wherein 0?x?4, A is a transition metal, B is a pnicogen, and 0?y?3 are formed for use in manufacturing thermoelectric devices with substantially enhanced operating characteristics and improved efficiency. Two methods of preparing p-type Zn4Sb3 and related alloys of the present invention include a crystal growth method and a powder metallurgy method.

Caillat, Thierry↗

Method and apparatus for detecting and determining event characteristics with reduced data collection

A method and apparatus for detecting and determining event characteristics such as, for example, the material failure of a component, in a manner which significantly reduces the amount of data collected. A sensor array, including a plurality of individual sensor elements, is coupled to a programmable logic device (PLD) configured to operate in a passive state and an active state. A triggering event is established such that the PLD records information only upon detection of the occurrence of the triggering event which causes a change in state within one or more of the plurality of sensor elements. Upon the occurrence of the triggering event, the change in state of the one or more sensor elements causes the PLD to record in memory which sensor element detected the event and at what time the event was detected. The PLD may be coupled with a computer for subsequent downloading and analysis of the acquired data.

Totman, Peter D.↗

Bubble domain circuit organization

An on-chip bubble domain circuit organization. One or more storage registers are connected to a propagation path whereby data in the form of magnetic bubble domains (bubbles) may be transferred into and out of the storage registers. The propagation path includes a generator for producing the initial bubbles which are expanded into any desired number of new bubbles by a unique multiple output replicator. A unique input decoder is utilized to determine to which storage register the bubbles from the replicator will be directed along the propagation path. Those bubbles not selected may be annihilated. An output decoder utilizing essentially the same decoding scheme as the input decoder, selectively receives bubbles from the storage register. A transfer and replicate switch is utilized between the storage register and output decoder to selectively transfer bubbles to the output decoder. The output decoder may collapse all of the bubbles from certain storage registers so that only the information from the selected storage register reaches the detector. The detectors in turn produce the chip output signal. External control electronics are utilized to control the selective operation of the various devices utilized in the propagation path.

Chen, Thomas T.↗

Advanced Embedded Active Assemblies for Extreme Space Applications

This work describes the development and evaluation of advanced technologies for the integration of electronic die within membrane polymers. Specifically, investigators thinned silicon die, electrically connecting them with circuits on flexible liquid crystal polymer (LCP), using gold thermo-compression flip chip bonding, and embedding them within the material. Daisy chain LCP assemblies were thermal cycled from -135 to +85degC (Mars surface conditions for motor control electronics). The LCP assembly method was further utilized to embed an operational amplifier designed for operation within the Mars surface ambient. The embedded op-amp assembly was evaluated with respect to the influence of temperature on the operational characteristics of the device. Applications for this technology range from multifunctional, large area, flexible membrane structures to small-scale, flexible circuits that can be fit into tight spaces for flex to fit applications.

lead bonding↗

Lunabotics Mining: Evolution of ARTEMIS PRIME

This slide presentation reviews the development of Amassing Regolith with Topper Engineers eMploying Innovative Solutions (ARTEMIS) in a competition to develop robotic lunar mining capabilities. The goal of the competition was to design, build and operate a remotely controlled device that is capable of excavating, transporting and discharging lunar regolith simulant in a lunar environment over a 13 minute period.

Bertke, Sarah↗

Simulation and Optimization of Vacuum Swing Adsorption Units for Spacesuit Carbon Dioxide and Humidity Control

Controlling carbon dioxide (CO2) and humidity levels in a spacesuit is critical to ensuring both the safety and comfort of an astronaut during extra-vehicular activity (EVA). Traditionally, this has been accomplished utilizing either non-regenerative lithium hydroxide (LiOH) or regenerative but heavy metal oxide (MetOx) canisters which pose a significant weight burden. Although such technology enables air revitalization, the volume requirements to store the waste canisters as well as the mass to transport multiple units become prohibitive as mission durations increase. Consequently, motivation exists toward developing a fully regenerative technology for spacesuit environmental control. The application of solid amine materials with vacuum swing adsorption technology has shown the capacity to control CO2 while concomitantly managing humidity levels through a fully regenerative cycle eliminating constraints imposed with the traditional technologies. Prototype air revitalization units employing this technology have been fabricated in both a rectangular and cylindrical geometry. Experimental results for these test articles have been collected and are described herein. In order to accelerate the developmental efforts, an axially-dispersed plug flow model with an accompanying energy balance has been established and correlated with the experimental data. The experimental and simulation results display good agreement for a variety of flow rates (110-170 ALM), replicated metabolic challenges (100-590 Watts), and atmosphere pressures under consideration for the spacesuit (248 and 760 mm Hg). The testing and model results lend insight into the operational capabilities of these devices as well as the influence the geometry of the device has on performance. In addition, variable metabolic profiles were imposed on the test articles in order to assess the ability of the technology to transition to new metabolic conditions. The advent of the model provides the capacity to apply computer-aided engineering practices to support the ongoing efforts to optimize and mature this technology for future application to space exploration.

Swickrath, Michael J.↗

Implications of Weak-Link Behavior on the Performance of Mo/Au Bilayer Transition-Edge Sensors

Understanding the physical properties of the superconducting-to-normal transition is fundamental for optimizing the design and performance of transition-edge sensors (TESs). Recent critical current measurements of Mol Au bilayer test structures show that they act as weak superconducting links, exhibiting oscillatory, Fraunhofer-like behavior with applied magnetic field. In this paper we investigate the implications of this behavior for TES X-ray detectors, under operational bias conditions. These devices include normal metal features used for absorber attachment and unexplained noise suppression, which result in modifications to the previously reported critical current behavior. We present measurements of the logarithmic resistance sensitivity with temperature, a, and current, b, as a function of applied magnetic field and bias point within the resistive transition. Results show that these important device parameters exhibit similar oscillatory behavior with applied magnetic field, which in turn affects the signal responsivity and noise, and hence the energy resolution. These results show the significance of the critical current in determining the performance of TESs and hold promise to improve future.

Smith, Stephen J.↗

Orbital Fitness: An Overview of Space Shuttle Cardiopulmonary Exercise Physiology Findings

Limited observations regarding the cardiopulmonary responses to aerobic exercise had been conducted during short-duration spaceflight before the Space Shuttle program. This presentation focuses on the findings regarding changes observed in the cardiopulmonary exercise responses during and following Shuttle flights. During flight, maximum oxygen uptake (VO2max) remained unchanged as did the maximum work rate achievable during cycle exercise testing conducted during the last full flight day. Immediately following flight, the ubiquitous finding, confirmed by investigations conducted during the Spacelab Life Sciences missions 1 and 2 and by NASA Detailed Supplemental Objective studies, indicated that VO2max was reduced; however, the reduction in VO2max was transient and returned to preflight levels within 7 days following return. Studies regarding the influence of aerobic exercise countermeasures performed during flight on postflight performance were mostly limited to the examination of the heart rate (HR) response to submaximal exercise testing on landing day. These studies revealed that exercise HR was elevated in individuals who performed little to no exercise during their missions as compared to individuals who performed regular exercise. In addition, astronauts who performed little to no aerobic exercise during flight demonstrated an increased HR and lowered pulse pressure response to the standard stand test on landing day, indicating a decrease in orthostatic function in these individuals. With regard to exercise modality, four devices were examined during the Shuttle era: two treadmills, a cycle ergometer, and a rowing device. Although there were limited investigations regarding the use of these devices for exercise training aboard the Shuttle, there was no clear consensus reached regarding which proved to be a "superior" device. Each device had a unique operational or physiologic limitation associated with its use. In conclusion, exercise research conducted during the Shuttle Program demonstrated that attenuation of postflight deconditioning was possible through use of exercise countermeasures and the Shuttle served as a test bed for equipment destined for use on the International Space Station. Learning Objective: Overview of the Space Shuttle Program research results related to aerobic capacity and performance, including what was learned from research and effectiveness of exercise countermeasures.

Moore, Alan D.↗

Whispering-Gallery-Mode Tunable Narrow-Band-Pass Filter

An experimental tunable, narrow-band-pass electro-optical filter is based on a whispering-gallery resonator. This device is a prototype of tunable filters needed for the further development of reconfigurable networking wavelength-division multiplexers and communication systems that utilize radio-frequency (more specifically, microwave) subcarrier signals on optical carrier signals. The characteristics of whispering-gallery resonators that make them attractive for such applications include high tuning speed, compactness, wide tuning range, low power consumption, and compatibility with single-mode optical fibers. In addition, relative to Fabry-Perot resonators, these devices offer advantages of greater robustness and lower cost. As described in several prior NASA Tech Briefs articles, a whispering-gallery resonator is a spheroidal, disk-like, or toroidal body made of a highly transparent material. It is so named because it is designed to exploit whispering-gallery electromagnetic modes, which are waveguide modes that propagate circumferentially and are concentrated in a narrow toroidal region centered on the equatorial plane and located near the outermost edge. The experimental whispering-gallery tunable filter (see figure) is made from a disk of Z-cut LiNbO3 of 4.8-mm diameter and 0.17-mm thickness. The perimeter of the disk is rounded to a radius of curvature of 100 m. Metal coats on the flat faces of the disk serve as electrodes for exploiting the electro-optical effect in LiNbO3 for tuning. There is no metal coat on the rounded perimeter region, where the whispering-gallery modes propagate. Light is coupled from an input optical fiber into the whispering-gallery modes by means of a diamond prism. Another diamond prism is used to couple light from the whispering-gallery modes to an output optical fiber. This device is designed and operated to exploit transverse magnetic (TM) whispering- gallery modes, rather than transverse electric (TE) modes because the resonance quality factors (Q values) of the TM modes are higher. If Q values were not of major concern, it would be better to use the TE modes because the electro-optical shifts of the TE modes are 3 times those of the TM modes.

Savchenkov, Anatoliy↗

Piezoelectric Diffraction-Based Optical Switches

Piezoelectric diffraction-based optoelectronic devices have been invented to satisfy requirements for switching signals quickly among alternative optical paths in optical communication networks. These devices are capable of operating with switching times as short as microseconds or even nanoseconds in some cases.

Spremo, Stevan↗

Apparatus and Method for Assessing Vestibulo-Ocular Function

A system for assessing vestibulo-ocular function includes a motion sensor system adapted to be coupled to a user's head; a data processing system configured to communicate with the motion sensor system to receive the head-motion signals; a visual display system configured to communicate with the data processing system to receive image signals from the data processing system; and a gain control device arranged to be operated by the user and to communicate gain adjustment signals to the data processing system.

Shelhamer, Mark J.↗

On-Orbit, Immuno-Based, Label-Free White Blood Cell Counting System with Microelectromechanical Sensor Technology (OILWBCS-MEMS)

Aurora Flight Sciences, in partnership with Draper Laboratory, has developed a miniaturized system to count white blood cells in microgravity environments. The system uses MEMS technology to simultaneously count total white blood cells, the five white blood cell differential subgroups, and various lymphocyte subtypes. The OILWBCS-MEMS detection technology works by immobilizing an array of white blood cell-specific antibodies on small, gold-coated membranes. When blood flows across the membranes, specific cells' surface protein antigens bind to their corresponding antibodies. This binding can be measured and correlated to cell counts. In Phase I, the partners demonstrated surface chemistry sensitivity and specificity for total white blood cells and two lymphocyte subtypes. In Phase II, a functional prototype demonstrated end-to-end operation. This rugged, miniaturized device requires minimal blood sample preparation and will be useful for both space flight and terrestrial applications.

Edmonds, Jessica↗

Multifunctional Electroactive Nanocomposites Based on Piezoelectric Boron Nitride Nanotubes

Space exploration missions require sensors and devices capable of stable operation in harsh environments such as those that include high thermal fluctuation, atomic oxygen, and high-energy ionizing radiation. However, conventional or state-of-the-art electroactive materials like lead zirconate titanate, poly(vinylidene fluoride), and carbon nanotube (CNT)-doped polyimides have limitations on use in those extreme applications. Theoretical studies have shown that boron nitride nanotubes (BNNTs) have strength-to-weight ratios comparable to those of CNTs, excellent high-temperature stability (to 800 C in air), large electroactive characteristics, and excellent neutron radiation shielding capability. In this study, we demonstrated the experimental electroactive characteristics of BNNTs in novel multifunctional electroactive nanocomposites. Upon application of an external electric field, the 2 wt % BNNT/polyimide composite was found to exhibit electroactive strain composed of a superposition of linear piezoelectric and nonlinear electrostrictive components. When the BNNTs were aligned by stretching the 2 wt % BNNT/polyimide composite, electroactive characteristics increased by about 460% compared to the nonstretched sample. An all-nanotube actuator consisting of a BNNT buckypaper layer between two single-walled carbon nanotube buck-paper electrode layers was found to have much larger electroactive properties. The additional neutron radiation shielding properties and ultraviolet/visible/near-infrared optical properties of the BNNT composites make them excellent candidates for use in the extreme environments of space missions. utilizing the unique characteristics of BNNTs.

Kang, Jin Ho↗