Study of factors determining the radiation sensitivity of quartz crystal oscillators (AO189)
Quartz resonators fabricated from two different grades of quartz material and selected for their susceptibility to radiation damage as determined by transmission electron microscopy (TEM), were tested prior to the LDEF flight. These resonators were then flown on the LDEF mission where they were exposed to the radiation environment of low Earth orbit. Post-flight tests were then conducted to determine any differences in resonator performance caused by the space exposure. Results of the TEM analysis of the quartz material and preflight and postflight measurements of the flight resonators and of the space and ground based control resonators are presented. Further planned work on the TEM analysis of the quartz materials will also be outlined.