Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Mechanical testing of large cryogenic structures

The mechanical testing performed on the Cryogenic Limb Array Etalon Spectrometer (CLAES) instrument installed on the Upper Atmosphere Research Satellite is discussed. The CLAES determines temperatures and concentrations of stratospheric minor species as a function of altitude by measuring the atmospheric infrared emission spectra. CLAES is based on a telescope optical system and infrared spectrometer which are cooled with cryogens.

Newkirk, Roger↗

Cryogenic fluid management investigations using the CONE flight experiment

The Cryogenic Orbital Nitrogen Experiment (CONE) is a liquid nitrogen cryogenic storage and supply system demonstration placed in orbit by the National Space Transportation System (NSTS) Orbiter and operated as an in-bay payload whose objective is to demonstrate needed critical components and technologies. A conceptual approach has been developed by Martin Marietta under contract with the NASA Lewis Research Center and an overview of the CONE program is described which includes a definition of the background and scope of the technology objectives being investigated, a description of the payload design and operation, major features and rationale for the experiments being conducted and the justification for CONE relating to potential near-term benefits and risk mitigation for future systems.

Bailey, W. J.↗

A PC-based collapse factor analysis for high pressure cryogenic systems

A collapse factor simulation computer program, suitable for use on personal computers, for supercritical cryogen system pressurization is examined. The available literature is previewed, individual component models are developed, and the overall simulation program logic is examined. Extensive use is made of existing thermodynamic and transport property evaluation packages. Heat transfer is estimated using natural convection correlations, and transient wall heat conduction is considered. Examples of the simulation are demonstrated for two facilities. Partial validation is achieved by comparing the simulation output with data from an existing test facility. Preliminary results indicate that the collapse factors will seldom exceed 1.15 during supercritical operation of high-pressure cryogenic systems. Recommendations for improvements in the component models and the simulation are made.

Hodge, B. K.↗

Lightweight Right-Angle Valve For Cryogenics

Lightweight right-angle valve isolates pressurized liquid or gas stream from vacuum over wide range of temperatures from ambient down to cryogenic. Sized to fit tubes of types ordinarily used in cryogenic equipment. Maintains isolation, without need for manual adjustment of packing gland as pressure and temperature vary. Mass of valve less than 60 grams. Made of off-the-shelf parts and few simple custom-machined parts.

Calhoun, Richard B.↗

Analysis Of Transfer Of Cryogens In Low Gravity

Report discusses calculations of thermodynamic aspects of refilling tanks with cryogenic liquids in low or zero gravity. Calculations required to design prototype system resupplying cryogenic propellant liquids to re-usable spacecraft not returning to Earth. Equations and computer programs developed for thermodynamic analysis used to extrapolate important design information from orbiting small-scale versions of system.

Defelice, David M.↗

Further buffeting tests in a cryogenic wind tunnel

Further measurements of buffeting, using wing-root strain gauges, were made in the NASA Langley 0.3 m Cryogenic Wind Tunnel to refine techniques which will be used in larger cryogenic facilities such as the United States National Transonic Facility (NTF) and European Transonic Wind Tunnel (ETW). The questions addressed included the relative importance of variations in frequency parameter and Reynolds number, the choice of model material (considering both stiffness and damping) and the effects of static aeroelastic distortion. The main series of tests was made on half models of slender 65 deg delta wings with a sharp leading edge. The three delta wings had the same planform but widely different bending stiffness and frequencies (obtained by varying both the material and the thickness of the wings). It was known that the flow on this configuration would be insensitive to variations in Reynold number. Additional tests were made on one unswept half-wing of aspect ratio 1.5 with an NPL 9510 aerofoil section, known to be sensitive to variations in Reynolds number at transonic speeds. For brevity the test Mach numbers were restricted to M = 0.21 and 0.35 for the delta wings and to M = 0.30 for the unswept wing.

Mabey, D. G.↗

Developing a safe on-orbit cryogenic depot

New U.S. space initiatives will require technology to realize planned programs such as piloted lunar and Mars missions. Key to the optimal execution of such missions are high performance orbit transfer vehicles and propellant storage facilities. Large amounts of liquid hydrogen and oxygen demand a uniquely designed on-orbit cryogenic propellant depot. Because of the inherent dangers in propellant storage and handling, a comprehensive system safety program must be established. This paper shows how the myriad and complex hazards demonstrate the need for an integrated safety effort to be applied from program conception through operational use. Even though the cryogenic depot is still in the conceptual stage, many of the hazards have been identified, including fatigue due to heavy thermal loading from environmental and operating temperature extremes, micrometeoroid and/or depot ancillary equipment impact (this is an important problem due to the large surface area needed to house the large quantities of propellant), docking and maintenance hazards, and hazards associated with extended extravehicular activity. Various safety analysis techniques were presented for each program phase. Specific system safety implementation steps were also listed. Enhanced risk assessment was demonstrated through the incorporation of these methods.

Bahr, Nicholas J.↗

Low cost, SPF aluminum cryogenic tank structure for ALS

Past production work has shown that cryogenic tank structure for the Shuttle Booster Rockets and the Titan system have very high life cycle costs for the fuel tank structure. The tanks are machined stiffener-skin combination that are subsequently formed into the required contour after machining. The material scrap rate for these configurations are usually high, and the loss of a tank panel due to forming or heat treatment problems is very costly. The idea of reducing the amount of scrap material and scrapped structural members has prompted the introduction of built-up structure for cryogenic tanks to be explored on the ALS program. A build-up structure approach that has shown improvements in life cycle cost over the conventional built-up approach is the use of superplastically formed (SPF) stiffened panels (reducing the overall part count and weight for the tank) resistance spot welded (RSW) to outer tank skin material. The stiffeners provide for general stability of the tank, while the skin material provides hoop direction continuity for the loads.

Anton, Claire E.↗

Cryogenic radiometers and intensity-stabilized lasers for Eos radiometric calibrations

Liquid helium-cooled electrical substitution radiometers (ESRs) provide irradiance standards with demonstrated absolute accuracy at the 0.01 percent level, spectrally flat response between the UV and IR, and sensitivity down to 0.1 nW/sq cm. We describe an automated system developed for NASA - Goddard Space Flight Center, consisting of a cryogenic ESR illuminated by servocontrolled laser beams. This system is designed to provide calibration of single-element and array detectors over the spectral range between 257nm in the UV to 10.6 microns in the IR. We also describe a cryogenic ESR optimized for black body calibrations that has been installed at NIST, and another that is under construction for calibrations of the CERES scanners planned for Eos.

Foukal, P.↗

Space Infrared Telescope Facility cryogenic and optical technology

SIRTF will require new liquid helium cryogenics and optical technology at liquid helium temperatures to meet the scientific requirements. In particular, it will require a helium cryogenic system operating at 1.25 K with a lifetime of five years. The optical system will require a 1-m mirror operating at 2 K, which is diffraction limited at 3 microns. This paper describes the advances which will be needed and the approaches to be taken.

Mason, P.↗

Performance of the Cryogenic Heat Pipe Experiment

The Cryogenic Heat Pipe (CRYOHP) Experiment has been designed to test two cryogenic heat pipes independently in a micro-gravity environment. The CRYOHP experiment is manifested for flight aboard the shuttle (STS-53) which is scheduled for launch in November, 1992. This paper presents the design of this experiment and the thermal vacuum verification test results. A correlation of the test data and the planned mission operations are also provided.

Brennan, Patrick J.↗

Cryogenic wind tunnels

Some of the major problems in wind tunnel research and testing are reviewed and solutions are suggested. Support interference, wall interference, flow unsteadiness, and low Reynolds number are all discussed. The evolution of cryogenic wind tunnels, principles of operation, and testing capabilities are reviewed. Several test facilities are described and the use of cryogenic wind tunnels to increase test Reynolds number is suggested.

Kilgore, Robert A.↗

Flight data for the Cryogenic Heat Pipe (CRYOHP) Experiment

This paper presents the flight test results and data correlation for the Cryogenic Heat Pipe Flight Experiment (CRYOHP). CRYOHP is a Hitchhiker Canister experiment that was flown aboard the shuttle Discovery (STS-53) in December of 1992. Two different axially grooved oxygen heat pipes were tested to determine their startup behavior and transport capability in micro-gravity. Three startup cycles were conducted with each heat pipe and transport data was obtained over the range of 60 K to 140 K. Startup in flight was repeatable but slower than observed in ground tests. The transport data shows good agreement with the theoretical model. The CRYOHP test bed, which incorporates five Stifling cycle refrigerators to provide the cryo-cooling, performed as predicted and offers a good micro-gravity test bed for cryogenic thermal devices.

Brennan, Patrick J.↗

Magnetic bearings for cryogenic turbomachines

Magnetic bearings offer a number of advantages over gas bearings for the support of rotors in cryogenic turboexpanders and compressors. Their performance is relatively independent of the temperature or pressure of the process gas for a large range of conditions. Active magnetic bearing systems that use capacitive sensors have been developed for high speed compressors for use in cryogenic refrigerators. Here, the development of a magnetic bearing system for a miniature ultra high speed compressor is discussed. The magnetic bearing has demonstrated stability at rotational speeds exceeding 250,000 rpm. This paper describes the important features of the magnetic bearing and presents test results demonstrating its performance characteristics.

Iannello, Victor↗

Gravity jitter excited cryogenic liquid slosh waves in microgravity environment

The dynamical behavior of fluids, in particular the effect of surface tension on partially-filled rotating fluids (cryogenic liquid helium and helium vapor) in a full-scale Gravity Probe-B Spacecraft liquid helium container tank without probe imposed by various frequencies of gravity jitter have been investigated. Results disclose the conditions for the excitation of large amplitude slosh waves which should be avoided in the design of cryogenic liquid propellant system.

Hung, R. J.↗

Acoustic composition sensor for cryogenic gas mixtures

An acoustic sensor useful for the determination of the composition of a gaseous binary mixture in cryogenic liquid spills has been characterized. One version of the instrument traps a known mixture of helium and nitrogen at ambient temperature in a tube which is interrogated by sonic pulses to determine the speed of sound and hence the composition. Experimental data shows that this sensor is quite accurate. The second version uses two unconfined microphones which sense sound pulses. Experimental data acquired during mixing when liquid nitrogen is poured into a vessel of gaseous helium is presented. Data during transient cooling of the tubular sensor containing nitrogen when the sensor is dipped into liquid nitrogen and during transient warm-up when the sensor is withdrawn are also presented. This sensor is being developed for use in the mixing of liquid cryogens with gas evolution in the simulation of liquid hydrogen/liquid oxygen explosion hazards.

Shakkottai, P.↗

Cryogenic propellant thermal control system design considerations, analyses, and concepts applied to a Mars human exploration mission

This paper analyzes, defines, and sizes cryogenic storage thermal control systems that meet the requirements of future NASA Mars human exploration missions. The design issues of this system include the projection of the existing Multilayer Insulation data base for cryogenic storage to much thicker (10 cm or more) insulation systems, the unknown heat leak from mechanical interfaces, and the thermal and structural performance effects of the large tank sizes required for a Mars mission. Acknowledging these unknown effects, heat loss projections are made based on extrapolation of the existing data base. The results indicate that hydrogen, methane, and oxygen are feasible propellants, and that the best suited thermal control sytems are 'thick' MLI, thermodynamic vent sytems, cryocoolers, and vacuum jackets.

Plachta, David W.↗

Evaluation of GaAs FETs for cryogenic readout

Low-frequency, low-noise, low-power cryogenic electronics to read out photodetectors is being investigated for the star-tracking telescope of the Gravity Probe B spacecraft. We report our initial findings from evaluating more than 20 types of GaAs FETs, both commercial and non-commercial, for this application. Most exhibit useable dc characteristics at cryogenic temperatures, although gate leakage and hysteretic effects (presumably due to charge trapping) could be troublesome. Low-frequency noise (based primarily on grounded-gate measurements) at 4 K is '1/f-like' and for the quietest GaAs FETs appears to be at least as low as the lowest noise values reported for Si MOSFETs at 4 K. Further investigation is needed in several areas.

Kirschman, Randall K.↗