Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “configurable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Visual Tool for Assessing Stability of DER Configurations on Three-Phase Radial Networks

Here, we present a method and tool for evaluating the placement of Distributed Energy Resources (DER) on distribution circuits in order to control voltages and power flows. Our previous work described Phasor-Based Control (PBC), a novel control framework where DERs inject real and reactive power to track voltage magnitude and phase angle targets. Here, we employ linearized power flow equations and integral controllers to develop a linear state space model for PBC acting on a three-phase unbalanced network. We use this model to evaluate whether a given inverter-based DER configuration admits a stable set of controller gains, which cannot be done by analyzing controllability nor by using the Lyapunov equation. Instead, we sample over a parameter space to identify a stable set of controller gains. Our stability analysis requires only a line impedance model and does not entail simulating the system or solving an optimization problem. We incorporate this assessment into a publicly available visualization tool and demonstrate three processes for evaluating many control configurations on the IEEE 123-node test feeder (123NF).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooling Configuration Design Considerations for Long-Length HTS Cables

Recent successes in demonstrating high temperature superconducting (HTS) cable systems hundreds of meters in length have inspired even longer length projects. A compact and energy efficient cooling configuration can be achieved using a counterflow-cooling arrangement. This is particularly attractive when all three phases are contained in a single cryostat because of the elimination of the space and thermal requirements of a separate liquid nitrogen return line. Future cable projects will utilize second generation (2G) wire which is expected to become lower in cost but may have different thermal requirements than first generation (1G) BSCCO wire due to the lower critical temperature and to a lesser extent, the lower thermal conductivity of the wire. HTS cable configurations will be studied with a numerical model to assess thermal hydraulic performance with AC and thermal losses; a summary of the results from the analysis will be presented. An analysis of the cable thermal- hydraulic response to over-current faults will be presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Assembly of a Large-Aperture Nb 3 Sn Cos-Theta Dipole Coil With Stress Management in Dipole Mirror Configuration

The stress-management cos-theta (SMCT) coil is a new concept which has been proposed and is being developed at Fermilab in the framework of US Magnet Development Program (US-MDP) for high-field and/or large-aperture accelerator magnets based on low-temperature and high-temperature superconductors. The SMCT structure is used to reduce large coil deformations under the Lorentz forces and, thus, the excessively large strains and stresses in the coil. A large-aperture Nb 3 Sn SMCT dipole coil has been developed and fabricated at Fermilab to demonstrate and test the SMCT concept including coil design, fabrication technology and performance. The first SMCT coil has been assembled with 60-mm aperture Nb 3 Sn coil inside a dipole mirror configuration and will be tested separately and in series with the insert coil. Here this paper summarizes the large-aperture SMCT coil design and parameters and reports the coil fabrication steps and its assembly in dipole mirror configuration.

43 PARTICLE ACCELERATORS↗

On the Configuration of the US Western Interconnection Voltage Stability Boundary

Abstract—Stability limits are considered in power system planning and operations to estimate the available stability margins and, if possible, to maximize the utilization of transmission facilities. These important tasks are influenced by configuration of the stability boundary. The paper introduces a new fast approach to explore the voltage stability boundary of a large system and reveal its detailed multidimensional structure. The 17939-bus U.S. Western Interconnection planning model was used to illustrate the method. Significant peculiarities of the boundary’s configuration were identified, including its nonconvexity, discontinuity, branching and internal singularities (“holes”) that were not known before and could not been found by traditional methods. Experiments using WECC system are performed to evaluate the computation time using different methods. Our results show that the proposed methods are very promising in reducing calculation time and complexity

Makarov, Yuri V.↗

OptZConfig: Efficient Parallel Optimization of Lossy Compression Configuration

Lossless compressors have very low compression ratios that do not meet the needs of today's large-scale scientific applications that produce vast volumes of data. Error-bounded lossy compression (EBLC) is considered a critical technique for the success of scientific research. Although EBLC allows users to set an error bound for the compression, users have been unable to specify the requirements on the compression quality, limiting practical use. Our contributions are: (1) We formulate the problem of configuring EBLC to preserve a user-defined metric as an optimization problem. This allows many classes of new metrics to be preserved, which improves over current practices. (2) We present a framework, OptZConfig, that can adapt to improvements in the search algorithm, compressor, and metrics with minimal changes, enabling future advancements in this area. (3) We demonstrate the advantages of our approach against the leading methods to configure compressors to preserve specific metrics. Here, our approach improves compression ratios against a specialized compressor by up to 3 x, has a 56x speedup over FRaZ, 1000x speedup over MGARD-QOI post tuning, and 110x speedup over systematic approaches which had not been bounded by compressors before.

97 MATHEMATICS AND COMPUTING↗

Numerical Simulation Comparison of Two Reactor Configurations for Chemical Looping Combustion and Chemical Looping With Oxygen Uncoupling

Chemical looping with oxygen uncoupling (CLOU) is a carbon capture technology that utilizes a metal oxide as an oxygen carrier to selectively separate oxygen from air and release gaseous O 2 into a reactor where fuel, such as coal, is combusted. Previous research has addressed reactor design for CLOU systems, but little direct comparison between different reactor designs has been performed. This study utilizes Barracuda-VR® for comparison of two system configurations, one uses circulating fluidized beds (CFB) for both the air reactor (AR) and fuel reactor (FR) and another uses bubbling fluidized beds for both reactors. Initial validation of experimental and computational fluid dynamic (CFD) simulations was performed to show that basic trends are captured with the CFD code. The CFD simulations were then used to perform comparison of key performance parameters such as solids circulation rate and reactor residence time, pressure profiles in the reactors and loopseals, and particle velocities in different locations of the reactor as functions of total solids inventory and reactor gas flows. Here, using these simulation results, it was determined that the dual CFB system had larger range for solids circulation rate before choked flow was obtained. Both systems had similar particle velocities for the bottom 80% of particle mass, but the bubbling bed (BB) obtained higher particle velocities as compared to the circulating fluidized-bed FR, due to the transport riser. As a system, the results showed that the dual CFB configuration allowed better control over the range of parameters tested.

30 DIRECT ENERGY CONVERSION↗

Evaluation of an a-Si EPID in direct detection configuration as a water-equivalent dosimeter for transit dosimetry

Purpose: A major problem associated with amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) for transit dosimetry is the presence of a phosphor layer, which can introduce large deviations from water-equivalent behavior due to energy-dependent response and visible light scattering. In this study, an amorphous silicon EPID was modified to a direct detection configuration by removing the phosphor layer, and the accuracy of using it for transit dosimetry measurements was investigated for 6 and 18 MV treatment beams by comparison to ion-chamber in water measurements. Methods: Solid water and copper were both evaluated as buildup materials. Using the optimum buildup thickness in each case, effects of changes in radiation field size, source to detector distance, and patient/phantom thickness were investigated by comparison to reference measurements made by an ionization chamber on the central axis. The off-axis response of the imager was also investigated by comparison of EPID image profiles to dose profiles obtained by a scanning ionization chamber in a water tank with various thicknesses of slab phantoms, and an anthropomorphic phantom in the beam using Gamma evaluation (3%, 3 mm criteria). The imaging characteristics of the direct EPID were investigated by comparison to a commercial EPID using QC3V phantom, and by taking images of an anthropomorphic pelvic phantom containing fiducial gold markers. Results: Either 30 mm of solid water or 3.3 mm of copper were found to be the most suitable buildup thicknesses with solid water providing more accurate results. Using solid water buildup, the EPID response compared to the reference dosimeter within 2% for all conditions except phantom thicknesses larger than 25 cm in 6 MV beams, which was up to 6.5%. Gamma evaluation results comparing EPID profiles and reference ionization chamber profiles showed that for 6 and 18 MV beams, at least 91.8% and 90.9% of points had a Gamma<1 for all phantoms, respectively. But using copper buildup, the EPID response had more discrepancies from the ionization chamber reference measurements, including: More than 2% difference for small air gaps using 6 MV beams, up to 8% difference for phantom thicknesses larger than 25 cm in 6 MV beams, and large differences (up to 9.3%) for increasing phantom thicknesses in 18 MV beams. The percentage of points with Gamma<1 with copper buildup were at least 96.6% and 99.8% in 6 and 18 MV beams, respectively. Conclusions: The direct EPID performs as an ion-chamber detector for transit dosimetry applications in all geometries studied except for small discrepancies at 6 MV for thick phantoms. This can be ameliorated by the calibration of the EPID to dose at an intermediate phantom thickness. The major current limitation of the direct EPID is poor quality of images compared with the clinical configuration, which could be overcome by a method to interchange between imaging and dosimetry setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-258: Parallel Optimization of Beam Configurations for CyberKnife Treatments

Purpose: The CyberKnife delivers a large number of beams originating at different non-planar positions and with different orientation. We study how much the quality of treatment plans depends on the beams considered during plan optimization. Particularly, we evaluate a new approach to search for optimal treatment plans in parallel by running optimization steps concurrently. Methods: So far, no deterministic, complete and efficient method to select the optimal beam configuration for robotic SRS/SBRT is known. Considering a large candidate beam set increases the likelihood to achieve a good plan, but the optimization problem becomes large and impractical to solve. We have implemented an approach that parallelizes the search by solving multiple linear programming problems concurrently while iteratively resampling zero weighted beams. Each optimization problem contains the same set of constraints but different variables representing candidate beams. The search is synchronized by sharing the resulting basis variables among the parallel optimizations. We demonstrate the utility of the approach based on an actual spinal case with the objective to improve the coverage. Results: The objective function is falling and reaches a value of 5000 after 49, 31, 25 and 15 iterations for 1, 2, 4, and 8 parallel processes. This corresponds to approximately 97% coverage in 77%, 59%, and 36% of the mean number of iterations with one process for 2, 4, and 8 parallel processes, respectively. Overall, coverage increases from approximately 91.5% to approximately 98.5%. Conclusion: While on our current computer with uniform memory access the reduced number of iterations does not translate into a similar speedup, the approach illustrates how to effectively parallelize the search for the optimal beam configuration. The experimental results also indicate that for complex geometries the beam selection is critical for further plan optimization.

07 ISOTOPE AND RADIATION SOURCES↗

WE-G-17A-08: Electron Gun Operation for in Line MRI-Linac Configurations: An Assessment of Beam Fidelity and Recovery Techniques for Different SIDs and Magnetic Field Strengths

Purpose: To test the functionality of medical electron guns within the fringe field of a purpose built superconducting MRI magnet, and to test different recovery techniques for a variety of imaging field strengths and SIDs. Methods: Three different electron guns were simulated using Finite Element Modelling; a standard diode gun, a standard triode gun, and a novel diode gun designed to operate within parallel magnetic fields. The approximate working regime of each gun was established by assessing exit current in constant magnetic fields of varying strength and defining ‘working’ as less than 10% change in injection current. Next, the 1.0T MRI magnet was simulated within Comsol Multiphysics. The coil currents in this model were also scaled to produce field strengths of .5, 1, 1.5 and 3T. Various magnetic shield configurations were simulated, varying the SID from 800 to 1300mm. The average magnetic field within the gun region was assessed together with the distortion in the imaging volume - greater than 150uT distortion was considered unacceptable. Results: The conventional guns functioned in fields of less than 7.5mT. Conversely, the redesigned diode required fields greater than .1T to function correctly. Magnetic shielding was feasible for SIDS of greater than 1000mm for field strengths of .5T and 1T, and 1100mm for 1.5 and 3.0T. Beyond these limits shielding resulted in unacceptable MRI distortion. In contrast, the redesigned diode could perform acceptably for SIDs of less than 812, 896, 931, and 974mm for imaging strengths of 0.5, 1.0, 1.5, 3.0T. Conclusions: For in-line MRIlinac configurations where the electron gun is operating in low field regions, shielding is a straight forward option. However, as magnetic field strength increases and the SID is reduced, shielding results in too great a distortion in the MRI and redesigning the electron optics is the preferable solution. The authors would like to acknowledge funding from the National Health and Research Council (AUS), National Institute of Health (NIH), and Cancer Institute NSW.

43 PARTICLE ACCELERATORS↗

Poster — Thur Eve — 64: Preliminary investigation of arc configurations for optimal sparing of normal tissue in hypofractionated stereotactic radiotherapy (HF-SRT) of multiple brain metastases using a 5mm interdigitating micro-multileaf collimator

Purpose: To evaluate normal tissue sparing in intra-cranial HF-SRT, comparing various arc configurations with the Synergy Beam Modulator (SynBM) and Agility linacs, the latter incorporating leaf interdigitation and backup jaws. Methods: Five patients with multiple brain metastases (BMs), (5 BMs (n=2), 3 BMs (n=3)) treated with HF-SRT using 25 Gy (n=2) or 30 Gy (n=3) in 5 fractions, were investigated. Clinical treatment plans used the SynBM. Each patient was retrospectively re-planned on Agility, employing three planning strategies: (A) one isocenter and dedicated arc for each BM; (B) a single isocenter, centrally placed with respect to BMs; (C) the isocenter and arc configuration used in the SynBM plan, where closely spaced (<5cm) BMs used a dedicated isocenter and arcs. Agility plans were normalized for PTV coverage and heterogeneity. Results and Conclusion: Strategy A obtained the greatest improvements over the SynBM plan, where the maximum OAR dose, and mean dose to normal brain (averaged for all patients) were reduced by 55cGy and 25cGy, respectively. Strategy B was limited by having a single isocenter, hence less jaw shielding and increased MLC leakage. The maximum OAR dose was reduced by 13cGy, however mean dose to normal brain increased by 84cGy. Strategy C reduced the maximum OAR dose and mean dose to normal brain by 32cGy and 9cGy, respectively. The results from this study indicate that, for intra-cranial HF-SRT of multiple BMs, Agility plans are equal or better than SynBM plans. Further planning is needed to investigate dose sparing using Strategy A and the SynBM.

60 APPLIED LIFE SCIENCES↗

SU-E-P-59: A Graphical Interface for XCAT Phantom Configuration, Generation and Processing

Purpose: To design a comprehensive open-source, publicly available, graphical user interface (GUI) to facilitate the configuration, generation, processing and use of the 4D Extended Cardiac-Torso (XCAT) phantom. Methods: The XCAT phantom includes over 9000 anatomical objects as well as respiratory, cardiac and tumor motion. It is widely used for research studies in medical imaging and radiotherapy. The phantom generation process involves the configuration of a text script to parameterize the geometry, motion, and composition of the whole body and objects within it, and to generate simulated PET or CT images. To avoid the need for manual editing or script writing, our MATLAB-based GUI uses slider controls, drop-down lists, buttons and graphical text input to parameterize and process the phantom. Results: Our GUI can be used to: a) generate parameter files; b) generate the voxelized phantom; c) combine the phantom with a lesion; d) display the phantom; e) produce average and maximum intensity images from the phantom output files; f) incorporate irregular patient breathing patterns; and f) generate DICOM files containing phantom images. The GUI provides local help information using tool-tip strings on the currently selected phantom, minimizing the need for external documentation. The DICOM generation feature is intended to simplify the process of importing the phantom images into radiotherapy treatment planning systems or other clinical software. Conclusion: The GUI simplifies and automates the use of the XCAT phantom for imaging-based research projects in medical imaging or radiotherapy. This has the potential to accelerate research conducted with the XCAT phantom, or to ease the learning curve for new users. This tool does not include the XCAT phantom software itself. We would like to acknowledge funding from MRA, Varian Medical Systems Inc.

60 APPLIED LIFE SCIENCES↗

Constructive molecular configurations for surface-defect passivation of perovskite photovoltaics

Surface trap-mediated nonradiative charge recombination is a major limit to achieving high-efficiency metal-halide perovskite photovoltaics. The ionic character of perovskite lattice has enabled molecular defect passivation approaches through interaction between functional groups and defects. However, a lack of in-depth understanding of how the molecular configuration influences the passivation effectiveness is a challenge to rational molecule design. In this work, the chemical environment of a functional group that is activated for defect passivation was systematically investigated with theophylline, caffeine, and theobromine. When N-H and C=O were in an optimal configuration in the molecule, hydrogen-bond formation between N-H and I (iodine) assisted the primary C=O binding with the antisite Pb (lead) defect to maximize surface-defect binding. A stabilized power conversion efficiency of 22.6% of photovoltaic device was demonstrated with theophylline treatment.

14 SOLAR ENERGY↗

Configuration splitting and gamma-decay transition rates in the two-group shell model

Expressions for reduced gamma-decay transition rates were obtained on the basis of the twogroup configuration model for the case of transitions between particles belonging to identical groups of nucleons. In practical applications, the present treatment is the most appropriate for describing decays for odd–odd nuclei in the vicinity of magic nuclei or for nuclei where the corresponding subshells stand out in energy. Also, a simple approximation is applicable to describing configuration splitting in those cases. The present calculations were performed for nuclei whose mass numbers are close to A ∼ 90, including N = 51 odd—odd isotones.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of 2 particle–2 hole configurations on dipole states in neutron-rich N = 80–84 isotones

Starting from the Skyrme interaction SLy4 we study the effects of 2 particle–2 hole configurations on the low-energy electric dipole response in {sup 130–134}Sn. It is shown that the pygmy dipole resonance properties are correlated with the neutron skin thickness. The two-phonon configurations give a considerable contribution to the low-lying E1 strength.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A field-reversed magnetic configuration and applications of high-temperature FRC plasma

As applied to a tokomak, a magnetic trap for confinement of a plasma with an inverted field or a magnetic field reversed configuration (FRC) is one of the most promising alternatives of the systems with high {beta}. A brief review of the latest data on FRC and potential directions of using such configurations in addition to energy generation in thermonuclear reactors (TNRs) is proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of charged particle motion in fields of different configurations for developing the concept of plasma separation of spent nuclear fuel

The concept of plasma separation of spent nuclear fuel in a plane perpendicular to the magnetic field in an electric potential of special configuration is developed. A specific feature of the proposed approach consists in using an accelerating potential for reducing energy and angular spread of plasma ions at the entrance to the separator chamber and a potential well for the spatial separation of ions with different masses. The trajectories of ions of the substance imitating spent nuclear fuel are calculated. The calculations are performed for azimuthal and axial magnetic fields and model electric field configurations corresponding to different geometries of the separator chamber. It is shown that, using magnetic fields with a characteristic strength of 1 kG and electric potentials of up to 1 kV inside a region with a linear size less than 100 cm, it is possible to separate ions of spent nuclear fuel with energies from 0.2 to 3 eV. The calculations were performed for a collisionless mode in the single-particle approximation. Possible variants of the experimental facility for plasma separation of spent nuclear fuel are proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parallel implementation and performance optimization of the configuration-interaction method

The configuration-interaction (CI) method, long a popular approach to describe quantum many-body systems, is cast as a very large sparse matrix eigenpair problem with matrices whose dimension can exceed one billion. Such formulations place high demands on memory capacity and memory bandwidth - - two quantities at a premium today. In this paper, we describe an efficient, scalable implementation, BIGSTICK, which, by factorizing both the basis and the interaction into two levels, can reconstruct the nonzero matrix elements on the fly, reduce the memory requirements by one or two orders of magnitude, and enable researchers to trade reduced resources for increased computational time. We optimize BIGSTICK on two leading HPC platforms - - the Cray XC30 and the IBM Blue Gene/Q. Specifically, we not only develop an empirically-driven load balancing strategy that can evenly distribute the matrix-vector multiplication across 256K threads, we also developed techniques that improve the performance of the Lanczos reorthogonalization. Combined, these optimizations improved performance by 1.3-8× depending on platform and configuration.

97 MATHEMATICS AND COMPUTING↗

Precautions of Using Three-Electrode Configuration to Measure Electrode Overpotential in Solid Oxide Electrochemical Cells: Insights from Finite Element Modeling

Accurate determination of electrode overpotentials is essential to assess the performance of the electrode and understand the rate-limiting steps involved. Three-electrode configuration with the use of a reference electrode at a fixed potential is a standard way to measure overpotential of a specific electrode in liquid electrochemical systems. However, application of such three-electrode configuration to solid electrochemical cells for overpotential determination is not straightforward and requires extra caution. Here we report a theoretical Finite Element Analysis on the geometrical requirements for which the reference electrode can be applied to anode- or electrolyte-supported solid oxide button cells. The modeling results suggest that the symmetry of the working and counter electrodes is the key factor determining if a reference electrode is suitable to use. For anode-supported fuel cells with asymmetrical working and counter electrodes, reference electrode cannot be used under all circumstances. To use reference electrode for overpotential measurements, electrolyte-supported cells with symmetrical semicircular-shaped electrodes are preferred. A data processing procedure has also been presented to obtain the electrode overpotential from the measured potential using the three-electrode scheme in solid oxide electrochemical cells.

25 ENERGY STORAGE↗