Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computer Codes Computer Programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

SU-E-T-32: A Feasibility Study of Independent Dose Verification for IMAT

Purpose: To assess the feasibility of the independent dose verification (Indp) for intensity modulated arc therapy (IMAT). Methods: An independent dose calculation software program (Simple MU Analysis, Triangle Products, JP) was used in this study, which can compute the radiological path length from the surface to the reference point for each control point using patient’s CT image dataset and the MLC aperture shape was simultaneously modeled in reference to the information of MLC from DICOM-RT plan. Dose calculation was performed using a modified Clarkson method considering MLC transmission and dosimetric leaf gap. In this study, a retrospective analysis was conducted in which IMAT plans from 120 patients of the two sites (prostate / head and neck) from four institutes were retrospectively analyzed to compare the Indp to the TPS using patient CT images. In addition, an ion-chamber measurement was performed to verify the accuracy of the TPS and the Indp in water-equivalent phantom. Results: The agreements between the Indp and the TPS (mean±1SD) were −0.8±2.4% and −1.3±3.8% for the regions of prostate and head and neck, respectively. The measurement comparison showed similar results (−0.8±1.6% and 0.1±4.6% for prostate and head and neck). The variation was larger in the head and neck because the number of the segments was increased that the reference point was under the MLC and the modified Clarkson method cannot consider the smooth falloff of the leaf penumbra. Conclusion: The independent verification program would be practical and effective for secondary check for IMAT with the sufficient accuracy in the measurement and CT-based calculation. The accuracy would be improved if considering the falloff of the leaf penumbra.

60 APPLIED LIFE SCIENCES↗

SU-F-T-169: A Periodic Quality Assurance Program for a Spot-Scanning Proton Treatment Facility

Purpose: To develop daily and monthly quality assurance (QA) programs in support of a new spot-scanning proton treatment facility using a combination of commercial and custom equipment and software. Emphasis was placed on efficiency and evaluation of key quality parameters. Methods: The daily QA program was developed to test output, spot size and position, proton beam energy, and image guidance using the Sun Nuclear Corporation rf-DQA™3 device and Atlas QA software. The program utilizes standard Atlas linear accelerator tests repurposed for proton measurements and a custom jig for indexing the device to the treatment couch. The monthly QA program was designed to test mechanical performance, image quality, radiation quality, isocenter coincidence, and safety features. Many of these tests are similar to linear accelerator QA counterparts, but many require customized test design and equipment. Coincidence of imaging, laser marker, mechanical, and radiation isocenters, for instance, is verified using a custom film-based device devised and manufactured at our facility. Proton spot size and position as a function of energy are verified using a custom spot pattern incident on film and analysis software developed in-house. More details concerning the equipment and software developed for monthly QA are included in the supporting document. Thresholds for daily and monthly tests were established via perturbation analysis, early experience, and/or proton system specifications and associated acceptance test results. Results: The periodic QA program described here has been in effect for approximately 9 months and has proven efficient and sensitive to sub-clinical variations in treatment delivery characteristics. Conclusion: Tools and professional guidelines for periodic proton system QA are not as well developed as their photon and electron counterparts. The program described here efficiently evaluates key quality parameters and, while specific to the needs of our facility, could be readily adapted to other proton centers.

60 APPLIED LIFE SCIENCES↗

Stereolithographic geometry model of the IBR-2M experimental facility

The IBR-2M is a fast research reactor that operates in supercritical condition for ∼ 800 μs every 200 ms. Two reflector parts in nickel rotate in opposite directions generating 1.8 GWth peak power when they align with the fuel zone changing the reactor status from deep subcritical to supercritical. The reactor core uses high-enriched plutonium fuel and is cooled by sodium. This reactor has been modeled by MCNP and SERPENT computer programs. The MCNP model uses combinatorial geometry, whereas the SERPENT model employs the Stereolithographic (STL) geometry representation that can be used by 3D printers. The STL geometry was constructed using the CUBIT computer program. The CUBIT program was also used for a three-dimensional visualization of the Monte Carlo models. SERPENT and MCNP models use the same geometry, material specifications, and nuclear data. The latter are based on the ENDF/B-7.0 library. SERPENT and MCNP using same geometry and same material specifications produce similar k{sub eff} values within 120 pcm.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ORNL Neutron Cross Section Measurements of 90 Zr NCSP ND-1 Task [Slides]

Luiz Leal's idea to integrate the experimental uncertainties, covariances, and sensitivities in this workflow and centralize the process at one location led to the creation of a cohesive tool for data testing. It has been practiced for more than two decades by the NCS and ND groups at ORNL. The development and use of the ORNL codes TSUNAMI and TSURFER within SCALE made it possible. Today, it has been extended to SAMINT which enables the coupling of differential and integral data evaluation in a continuous-energy framework.

43 PARTICLE ACCELERATORS↗

Modernization efforts for the R-Matrix code SAMMY [Slides]

This presentation details modernization efforts for the R-Matrix code SAMMY. It provides an overview of SAMMY, modernization and maintenance goals, modernization accomplishments, covariance data, SAMMY API development, as well as future plans.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Scattering Law Evaluations and Progress at NCSU [Slides]

The presentation discusses the eight new Thermal Scattering Law (TSL) evaluations that have been submitted to the National Nuclear Data Center (NNDC). It explains that evaluations are performed using the NCSU FLASSH code and that NJOY/LEAPR input files are provided to allow for independent testing. The presentation concludes by stating that more evaluations are expected to be submitted before the end of 2020.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studying the Random Number Generators in MCNP6 using an Analytic Benchmark

An analytic solution to a previously studied toy problem is derived and used as a code verification benchmark. Using various Random Number Generators (RNGs) in MCNP6, including the newest SFC64 RNG available in MCNP6.3.1, and their various properties (e.g., RNG stride), we show how these RNGs perform and how to correct or workaround potential issues with respect to the analytic benchmark problem.

97 MATHEMATICS AND COMPUTING↗

Advanced Pellet Cladding Interaction Modeling Using the US DOE CASL Fuel Performance Code: Peregrine

The US DOE’s Consortium for Advanced Simulation of LWRs (CASL) program has undertaken an effort to enhance and develop modeling and simulation tools for a virtual reactor application, including high fidelity neutronics, fluid flow/thermal hydraulics, and fuel and material behavior. The fuel performance analysis efforts aim to provide 3-dimensional capabilities for single and multiple rods to assess safety margins and the impact of plant operation and fuel rod design on the fuel thermomechanical- chemical behavior, including Pellet-Cladding Interaction (PCI) failures and CRUD-Induced Localized Corrosion (CILC) failures in PWRs. [1-3] The CASL fuel performance code, Peregrine, is an engineering scale code that is built upon the MOOSE/ELK/FOX computational FEM framework, which is also common to the fuel modeling framework, BISON [4,5]. Peregrine uses both 2-D and 3-D geometric fuel rod representations and contains a materials properties and fuel behavior model library for the UO2 and Zircaloy system common to PWR fuel derived from both open literature sources and the FALCON code [6]. The primary purpose of Peregrine is to accurately calculate the thermal, mechanical, and chemical processes active throughout a single fuel rod during operation in a reactor, for both steady state and off-normal conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutronics Analysis of Cold Critical KRUSTY Experiments using MCNP and Serpent

Kilowatt Reactor Using Stirling Technology (KRUSTY) is a prototype designed as a proof of concept for NASA’s Kilo power program, which was funded in order to create a small reactor for various space applications such as providing power for a colony on Mars or the moon and eventually as a possible option for powering rockets on deep space missions. KRUSTY was tested at the National Criticality Experiments Research Center (NCERC) located at the Nevada National Security Site (NNSS) from November 2017, through March 2018. The experimental campaign was conducted in four phases: com ponent critical experiments, cold critical experiments, warm critical runs, and high temperature demonstration. The component critical and cold critical experiments were used to determine the worth of the beryllium oxide (BeO) reflector rings and the boron carbide (B4C) control rod disks under different conditions. These conditions were altered by the addition and subtraction of other components in the assembly. The component critical phase was performed at atmospheric pressure and had four solid support rods spanning the center core; whereas the cold critical phase had the center core placed in a vacuum chamber and eight sodium-filled heat pipes spanning the center core region. This summary discusses the static neutronic analysis completed on the cold critical phase of the campaign using MCNP ® and Serpent. These two codes were used to assess any potential differences or biases in the simulation results. Understanding these potential biases is a key step toward the final goal of being able to fully analyze the transient experiments performed during phases 3 and 4 of the campaign.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integrating Energy-Efficient Computing with Computational Research to Accelerate Energy Technology

NREL's computational sciences center hosts the largest high performance computing (HPC) capabilities dedicated to energy research while functioning as a living laboratory for energy-efficient computing. NREL's HPC capabilities support the research needs of the Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). In ten years of operation, HPC use in EERE-sponsored research has grown by a factor of 30, including work in electricity generation, energy efficiency, transportation, and energy system modeling. This paper analyzes this research portfolio, providing examples of individual use cases. The paper documents NREL's history of operating one of the world's most energy-efficient data centers while examining pathways to reduce economic and environmental impact beyond reduction of Power Usage Efficiency (PUE). This paper concludes by examining the unique opportunities created for accelerating improvements in data center efficiency created by combining an HPC system dedicated to energy research and a research program in energy-efficient computing.

97 MATHEMATICS AND COMPUTING↗

A MLIR Dialect for Quantum Assembly Languages

We demonstrate the utility of the Multi-Level Intermediate Representation (MLIR) for quantum computing. Specifically, we extend MLIR with a new quantum dialect that enables the expression and compilation of common quantum assembly languages. The true utility of this dialect is in its ability to be lowered to the LLVM intermediate representation (IR) in a manner that is adherent to the quantum intermediate representation (QIR) specification recently proposed by Microsoft. We leverage a qcor-enabled implementation of the QIR quantum runtime API to enable a retargetable (quantum hardware agnostic) compiler workflow mapping quantum languages to hybrid quantum-classical binary executables and object code. We evaluate and demonstrate this novel compiler workflow with quantum programs written in OpenQASM 2.0. We provide concrete examples detailing the generation of MLIR from OpenQASM source files, the lowering process from MLIR to LLVM IR, and ultimately the generation of executable binaries targeting available quantum processors.

Mccaskey, Alex↗

The Monte Carlo estimation of an effect of uncertainties in initial data on solving the transport equation by means of the MCU code

A new version of the tally module of the MCU software package is developed in which the approach for taking directly into account the uncertainty in initial data is implemented that is recommended by the international standard on estimating the uncertainty in results of measuring (ISO 13005). The new module makes it possible to evaluate the effect of uncertainty in initial data (caused by technological tolerances in fabrication of structural members of the core) on neutronic characteristics of the reactor. The developed software is adapted to parallel computing with the use of multiprocessor computers, which significantly reduces the computation time: the parallelization coefficient is almost equal to 1. Testing is performed by examples of solving the problem on criticality for the Godiva benchmark experiment and also for the infinite lattice of fuel assemblies of the VVER-440, VVER-1000, and VVER-1200. The results of calculations of the uncertainty in neutronic characteristics (effective multiplication factor, fission reaction rate), which is caused by uncertainties in initial data due to technological tolerances, are compared (in the first case) to the published results obtained using the precision MCNP5 code and (in the second case) to those obtained by means of the RADAR engineering program. A good agreement of results is achieved for all cases.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ITS version 6.4: The Integrated TIGER Series of Monte Carlo Electron/Photon Radiation Transport Codes - Paper 40

ITS (Integrated TIGER Series) is a suite of fully coupled electron/photon Monte Carlo radiation transport codes. The package contains programs to perform 1D, 2D and 3D simulations. The 3D geometry representations include the traditional combinatorial geometry (CG), facet-based models, CAD models for those users who have a license for the ACIS{sup R} CAD libraries, and hybrid models of any combination. There is a multigroup version which permits adjoint analysis. The availability of source code permits the more sophisticated user to tailor the code to specific applications and to extend the capabilities of the codes to more complex applications. ITS is presently available only through a U.S.-government-use license. It is available once again through the Radiation Safety Information Computational Center (RSICC). (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

VERAOUT - VERA HDF5 Output Specification (Revision 1)

This document describes the revised specification (Revision 1) for the format of the common VERA Output file (VERAOUT). VERAOUT is a binary HDF5 file that all of the physics codes in VERA-CS produce. Having all physics codes write to a single file simplifies post-processing and data comparison. The edits and format written to the VERAOUT file is described below. This specification covers common scalar and array data typically produced by neutronic and fuel performance codes. This document will be periodically revised to add additional data as more physics codes and/or more data is added to VERA-CS. A version number is written to the HDF file to keep track of different versions of the VERAOUT so that backwards compatibility may be maintained. A sample VERAOUT reader has been written to serve as an example for users wishing to do data postprocessing. Information on this program is included below.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

XtalCAMP: a comprehensive program for the analysis and visualization of scanning Laue X-ray micro-/nanodiffraction data

XtalCAMP is a software package based on the MATLAB platform, which is suitable for, but not limited to, the analysis and visualization of scanning Laue X-ray micro-/nanodiffraction data. The main objective of the software is to provide complementary functionalities to the Laue indexing software packages used at several synchrotron beamlines. Here, the graphical user interfaces allow the easy analysis of characteristic microstructure features, including real-time intensity mapping for a quick examination of phase, grain and defect distribution, 2D color-coded mapping of microstructural properties from the output of other Laue indexing software, crystal orientation visualization, grain boundary characterization based on orientation/misorientation calculation, principal strain/stress analysis, and strain ellipsoid representation, as well as a series of additional toolkits. As an example, XtalCAMP is applied to the microstructural investigation of a solution-heat-treated Ni-based superalloy manufactured using a laser 3D-printing technique, and a deformed natural quartzite from Val Bregaglia in the Central Alps.

36 MATERIALS SCIENCE↗

Generalized Bayesian Framework for Evaluation of Integral Benchmark Experiments

A recently published generalized Bayesian optimization framework has provided a way to retract any or all of the three common assumptions underlying the conventional Generalized Linear Least Squares (GLLS) optimization method based on the concepts introduced in Ref. [2]. These assumptions are: 1. Perfection: The model used for data evaluation and the prior probability distribution function (PDF) of generalized data are perfect. 2. Normality: The prior and posterior PDF are normal. 3. Linearity: The model is linear. In this work we outline how the framework in [1] could be directly adopted for improved evaluation of nuclear criticality integral benchmark experiments (IBEs) by: 1. Removing the first assumption alone by utilizing the concept of imperfections introduced in [1] to enable evaluation in the presence of discrepancies between the data and model or of missing covariance information by a GLLS method that will be seen as a generalization of the conventional GLLS method employed by the TSURFER code, and by 2. Removing the remaining two assumptions by implementing a Markov Chain Monte Carlo method for computation of the posterior PDF in the SAMPLER code, where TSURFER and SAMPLER are the uncertainty quantification (UQ) codes for IBEs in the SCALE code system based on the GLLS and the stochastic method, respectively. The graphic in Figure 1 categorizes the methods discussed in terms of the assumptions that they employ to determine posterior PDFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-570: New Quality Assurance Method Using Motion Tracking for 6D Robotic Couches

Purpose: To accommodate geometrically accurate patient positioning, a robotic couch that is capable of 6-degrees of freedom has been introduced. However, conventional couch QA methods are not sufficient to enable the necessary accuracy of tests. Therefore, we have developed a camera based motion detection and geometry calibration system for couch QA. Methods: Employing a Visual-Tracking System (VTS, BonitaB10, Vicon, UK) which tracks infrared reflective(IR) markers, camera calibration was conducted using a 5.7 × 5.7 × 5.7 cm{sup 3} cube attached with IR markers at each corner. After positioning a robotic-couch at the origin with the cube on the table top, 3D coordinates of the cube’s eight corners were acquired by VTS in the VTS coordinate system. Next, positions in reference coordinates (roomcoordinates) were assigned using the known relation between each point. Finally, camera calibration was completed by finding a transformation matrix between VTS and reference coordinate systems and by applying a pseudo inverse matrix method. After the calibration, the accuracy of linear and rotational motions as well as couch sagging could be measured by analyzing the continuously acquired data of the cube while the couch moves to a designated position. Accuracy of the developed software was verified through comparison with measurement data when using a Laser tracker (FARO, Lake Mary, USA) for a robotic-couch installed for proton therapy. Results: VTS system could track couch motion accurately and measured position in room-coordinates. The VTS measurements and Laser tracker data agreed within 1% of difference for linear and rotational motions. Also because the program analyzes motion in 3-Dimension, it can compute couch sagging. Conclusion: Developed QA system provides submillimeter/ degree accuracy which fulfills the high-end couch QA. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning. (2013M2A2A7043507 and 2012M3A9B6055201)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-TeP1-06: Fast GPU Framework for Four-Dimensional Monte Carlo in Adaptive Intensity Modulated Proton Therapy (IMPT) for Mobile Tumors

Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) treatment planning and verification using four-dimensional CT (4DCT) for adaptive IMPT for lung cancer patients. Methods: A validated GPU MC code, gPMC, has been linked to the patient database at our institution and employed to compute the dose-influence matrices (Dij) on the planning CT (pCT). The pCT is an average of the respiratory motion of the patient. The Dijs and patient structures were fed to the optimizer to calculate a treatment plan. To validate the plan against motion, a 4D dose distribution averaged over the possible starting phases is calculated using the 4DCT and a model of the time structure of the delivered spot map. The dose is accumulated using vector maps created by a GPU-accelerated deformable image registration program (DIR) from each phase of the 4DCT to the reference phase using the B-spline method. Calculation of the Dij matrices and the DIR are performed on a cluster, with each field and vector map calculated in parallel. Results: The Dij production takes ∼3.5s per beamlet for 10e6 protons, depending on the energy and the CT size. Generating a plan with 4D simulation of 1000 spots in 4 fields takes approximately 1h. To test the framework, IMPT plans for 10 lung cancer patients were generated for validation. Differences between the planned and the delivered dose of 19% in dose to some organs at risk and 1.4/21.1% in target mean dose/homogeneity with respect to the plan were observed, suggesting potential for improvement if adaptation is considered. Conclusion: A fast MC treatment planning framework has been developed that allows reliable plan design and verification for mobile targets and adaptation of treatment plans. This will significantly impact treatments for lung tumors, as 4D-MC dose calculations can now become part of planning strategies.

60 APPLIED LIFE SCIENCES↗