Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomic structure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Density of molten oxides measured in an aero-acoustic levitator

Knowing the thermophysical properties of high-temperature melts can aid the design of melt processes and validate atomic structural models, such as those used in studying glass formation. Property measurements on such melts are challenging, however, due to container-related contamination and heterogeneous nucleation. Containerless processing techniques that employ levitation can be used to avoid these obstacles. In that context, we demonstrate here the application of silhouette imaging to measure the density of molten oxides in an aero-acoustic levitation instrument (AAL). The AAL combines gas jet levitation with actively controlled acoustic positioning to enable full optical access to samples ca. 2–4 mm in diameter, which are laser beam heated and melted. The cross sections of molten drops are imaged using a monochromatic light source and narrowband-filtered camera. Melt volume is calculated from the cross sections and used to find density at several temperatures ranging 1530–1920 K, including up to 350 K of supercooling. We report densities for CaAl 2 O 4 , Ca 12 Al 14 O 33 , CaSiO 3 , their Fe 2 O 3 -bearing analogs, and 83TiO 2 -17RE 2 O 3 (RE = La or Nd). These provide important benchmarks of the capabilities, measurement uncertainties, and future outlook for this technique.

36 MATERIALS SCIENCE↗

Multiframe X-ray diffraction on the OMEGA EP laser

A method of measuring multiple temporally resolved powder x-ray diffraction measurements during a single dynamic compression laser experiment has been demonstrated on the OMEGA EP laser. Up to four time-gated snapshots of the x-ray diffraction pattern are collected on an ultrafast x-ray framing camera with a 2θ scattering angle coverage of 48°–65° and 400-ps temporal resolution with the potential for 10°–160° and 200-ps resolution. X-ray diffraction snapshots capture the transformation to a high-pressure β phase in ramp-compressed Zr, constraining the atomic structure and pressure–density equation-of-state in a single shot. Here, this platform will be used to constrain transition pressures, understand the role of kinetics, and verify the existence of hysteresis and metastability on phase transformations at the lattice level under single-shot dynamic compression.

47 OTHER INSTRUMENTATION↗

Alpha-spectrometry and fractal analysis of surface micro-images for characterisation of porous materials used in manufacture of targets for laser plasma experiments

We present the results of employing the alpha-spectrometry method to determine the characteristics of porous materials used in targets for laser plasma experiments. It is shown that the energy spectrum of alpha-particles, after their passage through porous samples, allows one to determine the distribution of their path length in the foam skeleton. We describe the procedure of deriving such a distribution, excluding both the distribution broadening due to statistical nature of the alpha-particle interaction with an atomic structure (straggling) and hardware effects. The fractal analysis of micro-images is applied to the same porous surface samples that have been studied by alpha-spectrometry. The fractal dimension and size distribution of the number of the foam skeleton grains are obtained. Using the data obtained, a distribution of the total foam skeleton thickness along a chosen direction is constructed. It roughly coincides with the path length distribution of alpha-particles within a range of larger path lengths. It is concluded that the combined use of the alpha-spectrometry method and fractal analysis of images will make it possible to determine the size distribution of foam skeleton grains (or pores). The results can be used as initial data in theoretical studies on propagation of the laser and X-ray radiation in specific porous samples. (laser plasma)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging local electric fields produced upon synchrotron X-ray exposure

Electron-hole separation following hard X-ray absorption during diffraction analysis of soft materials under cryogenic conditions produces substantial local electric fields visualizable by second harmonic generation (SHG) microscopy. Monte Carlo simulations of X-ray photoelectron trajectories suggest the formation of substantial local electric fields in the regions adjacent to those exposed to X-rays, indicating a possible electric-field-induced SHG (EFISH) mechanism for generating the observed signal. In studies of amorphous vitreous solvents, analysis of the SHG spatial profiles following X-ray microbeam exposure was consistent with an EFISH mechanism. Within protein crystals, exposure to 12-keV (1.033-angstrom) X-rays resulted in increased SHG in the region extending similar to 3 mu m beyond the borders of the X-ray beam. Moderate X-ray exposures typical of those used for crystal centering by raster scanning through an X-ray beam were sufficient to produce static electric fields easily detectable by SHG. The X-ray-induced SHG activity was observed with no measurable loss for longer than 2 wk while maintained under cryogenic conditions, but disappeared if annealed to room temperature for a few seconds. These results provide direct experimental observables capable of validating simulations of X-ray-induced damage within soft materials. In addition, X-ray-induced local fields may potentially impact diffraction resolution through localized piezoelectric distortions of the lattice.

Dettmar, Christopher M.↗

Stable iridium dinuclear heterogeneous catalysts supported on metal-oxide substrate for solar water oxidation

Significance While research on single-atom catalysts (SACs) is arguably mature, rare work has been done on atomically dispersed catalyst featuring two atoms. We synthesized Ir dinuclear heterogeneous catalyst in a facile photochemical way. It exhibits outstanding stability and high activity toward water oxidation. The significance of this work can also be appreciated from the catalysis perspective. A grand challenge in heterogeneous catalysis is how to understand the detailed mechanisms at the molecular level, because the most active heterogeneous catalysts are often poorly defined in their atomic structures. Our finding is built upon recent advances aimed at studying SACs but takes a crucial step forward. It provides a material platform to study reactions that would require more than one active site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Materials Research with X-ray Micro-beams at the Advanced Photon Source

X-ray scattering has had a rich and prominent place in the history of materials research. For samples that are large single crystals, X-ray diffraction provides very detailed, high-quality information about the atomic structure of almost every kind. However, most engineering materials are not a large single crystal, but mixtures of materials or a poly-crystalline material. Still, X-ray diffraction using X-ray beams significantly larger than the structures being investigated has produced much excellent information. Examples of this are powder diffraction, texture analysis, strain analysis, etc. While these types of analyses have been very useful in providing a microscopic understanding, they do not provide the microscopic information that we really want. What we really want to have is this useful X-ray diffraction information for every volume element in our sample; not just the diffraction information about small volume elements, but all of the volume elements, exactly where they are in our sample, and how each one diffracts. Furthermore this detailed spatial and structural information is what is needed for a full understanding of the source of the properties that we find in engineering materials.

36 MATERIALS SCIENCE↗

CORONIUM IN THE LABORATORY: MEASURING THE Fe XIV GREEN CORONAL LINE BY LASER SPECTROSCOPY

The green coronal line at 530.3 nm was first observed during the total solar eclipse of 1869. Once identified as emitted by Fe XIV, it became clear that this highly charged ion was typical for the range of temperatures found in coronal plasmas, stellar winds, outflows, and accretion disks. Under these conditions of high ionization, the strongest transitions are in the X-ray, extreme ultraviolet, and ultraviolet wavelength range, with only few optical lines. For these so-called forbidden coronal lines, only scarce laboratory data is available, and even advanced atomic theory codes cannot yet predict their wavelengths with the accuracy required for precise absolute velocity determinations of such plasmas. Here we report on a study of the Fe XIV line, a key coronal transition of a highly charged ion, using laser spectroscopy in an electron beam ion trap, obtaining the first laboratory measurement of 530.2801(4) nm for its rest wavelength. The result enables the determination of absolute line shifts and line broadenings in hot turbulent plasmas and astrophysical environments, with an error bar of only 0.24 km s{sup –1}. In addition, our measurement provides a much-needed benchmark for advanced atomic structure calculations, which are fundamental for astronomy.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron-impact excitation of Fe{sup 2+}: A comparison of intermediate coupling frame transformation, Breit-Pauli and Dirac R-matrix calculations

Modeling the spectral emission of low-charge iron group ions enables the diagnostic determination of the local physical conditions of many cool plasma environments such as those found in H II regions, planetary nebulae, active galactic nuclei, etc. Electron-impact excitation drives the population of the emitting levels and, hence, their emissivities. By carrying-out Breit-Pauli and intermediate coupling frame transformation (ICFT) R-matrix calculations for the electron-impact excitation of Fe{sup 2+}, which both use the exact same atomic structure and the same close-coupling expansion, we demonstrate the validity of the application of the powerful ICFT method to low-charge iron group ions. This is in contradiction to the finding of Bautista et al., who carried-out ICFT and Dirac R-matrix calculations for the same ion. We discuss possible reasons.

79 ASTRONOMY AND ASTROPHYSICS↗

A SEMI-ANALYTICAL LINE TRANSFER MODEL TO INTERPRET THE SPECTRA OF GALAXY OUTFLOWS

We present a semi-analytical line transfer model, (SALT), to study the absorption and re-emission line profiles from expanding galactic envelopes. The envelopes are described as a superposition of shells with density and velocity varying with the distance from the center. We adopt the Sobolev approximation to describe the interaction between the photons escaping from each shell and the remainder of the envelope. We include the effect of multiple scatterings within each shell, properly accounting for the atomic structure of the scattering ions. We also account for the effect of a finite circular aperture on actual observations. For equal geometries and density distributions, our models reproduce the main features of the profiles generated with more complicated transfer codes. Also, our SALT line profiles nicely reproduce the typical asymmetric resonant absorption line profiles observed in starforming/starburst galaxies whereas these absorption profiles cannot be reproduced with thin shells moving at a fixed outflow velocity. We show that scattered resonant emission fills in the resonant absorption profiles, with a strength that is different for each transition. Observationally, the effect of resonant filling depends on both the outflow geometry and the size of the outflow relative to the spectroscopic aperture. Neglecting these effects will lead to incorrect values of gas covering fraction and column density. When a fluorescent channel is available, the resonant profiles alone cannot be used to infer the presence of scattered re-emission. Conversely, the presence of emission lines of fluorescent transitions reveals that emission filling cannot be neglected.

79 ASTRONOMY AND ASTROPHYSICS↗

Contamination of argon x-ray spectra by tungsten and other elements commonly found in tokamaks

Here, emission lines which appear in the spectral ranges of ground state transitions from n> = 2 levels in He- and H-like argon ions are discussed. X-ray transitions from elements commonly found in tokamaks (tungsten, molybdenum, iron and sulphur) which radiate in the wavelength range from 3700–4000 mÅ are identified by comparison with atomic structure calculations. Individual lines from tungsten charge states in the vicinity of Zn-like W 44+ are documented, along with B-like Mo 37+ . The behaviour of line ratios as a function of electron temperature is examined, in support of the identifications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute nuclear charge radius by Na-like spectral line separation in high-Z elements

Abstract We describe a novel technique to determine absolute nuclear radii of high- Z nuclides. Utilizing accurate theoretical atomic structure calculations together with precise measurements of extreme ultraviolet transitions in highly charged ions this method allows for precise determinations of absolute nuclear charge radii based upon the well-known nuclear radii of their neighboring elements. This method can work for elements without stable isotopes, and its accuracy may be competitive with current methods (electron scattering and muonic x-ray spectroscopy).

Hosier, A. (ORCID:0000000328366605)↗

Modeling of particle transport, neutrals and radiation in magnetically-confined plasmas with Aurora

In this work, we present Aurora, an open-source package for particle transport, neutrals and radiation modeling in magnetic confinement fusion plasmas. Aurora's modern multi-language interface enables simulations of 1.5D impurity transport within high-performance computing frameworks, particularly for the inference of particle transport coefficients. A user-friendly Python library allows simple interaction with atomic rates from the Atomic Data and Atomic Structure database as well as other sources. This enables a range of radiation predictions, both for power balance and spectroscopic analysis. We discuss here the superstaging approximation for complex ions, as a way to group charge states and reduce computational cost, demonstrating its wide applicability within the Aurora forward model and beyond. Aurora also facilitates neutral particle analysis, both from experimental spectroscopic data and other simulation codes. Leveraging Aurora's capabilities to interface SOLPS-ITER results, we demonstrate that charge exchange is unlikely to affect the total radiated power from the ITER core during high performance operation. Finally, we describe the ImpRad module in the one modeling framework for integrated task framework, developed to enable experimental analysis and transport inferences on multiple devices using Aurora.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Attosecond transient absorption of a bound wave packet coupled to a smooth continuum

Here, we investigate the possibility of using transient absorption of a coherent bound electron wave packet in hydrogen as an attosecond pulse characterization technique. In a recent work, we have shown that photoionization of such a coherent bound electron wave packet opens up for pulse characterization with unprecedented temporal accuracy—independent of the atomic structure—with maximal photoemission at all kinetic energies given a wave packet with zero relative phase. Here, we perform numerical propagation of the time-dependent Schrödinger equation and analytical calculations based on perturbation theory to show that the energy-resolved maximal absorption of photons from the attosecond pulse does not uniquely occur at a zero relative phase of the initial wave packet. Instead, maximal absorption occurs at different relative wave packet phases, distributed as a non-monotonous function with a smooth $-\pi /2$ shift across the central photon energy (given a Fourier-limited Gaussian pulse). Similar results are also found in helium. Our finding is surprising, because it implies that the energy-resolved photoelectrons are not mapped one-to-one with the energy-resolved absorbed photons of the attosecond pulse.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First-principles simulation of light-ion microscopy of graphene

The extreme sensitivity of 2D materials to defects and nanostructure requires precise imaging techniques to verify presence of desirable and absence of undesirable features in the atomic geometry. Helium-ion beams have emerged as a promising materials imaging tool, achieving up to 20 times higher resolution and 10 times larger depth-of-field than conventional or environmental scanning electron microscopes. Here, we offer first-principles theoretical insights to advance ion-beam imaging of atomically thin materials by performing real-time time-dependent density functional theory simulations of single impacts of 10–200 keV light ions in free-standing graphene. Here we predict that detecting electrons emitted from the back of the material (the side from which the ion exits) would result in up to three times higher signal and up to five times higher contrast images, making 2D materials especially compelling targets for ion-beam microscopy. This predicted superiority of exit-side emission likely arises from anisotropic kinetic emission. The charge induced in the graphene equilibrates on a sub-fs time scale, leading to only slight disturbances in the carbon lattice that are unlikely to damage the atomic structure for any of the beam parameters investigated here.

36 MATERIALS SCIENCE↗

Advances in scientific literature mining for interpreting materials characterization

Abstract Using synchrotron light sources, such as the National Synchrotron Light Source II at Brookhaven National Laboratory, scientists in fields as diverse as physics, biology, and materials science, identify the atomic structure, chemical composition, or other important properties of varied specimens. x-ray spectroscopy from light sources is particularly valuable for materials research with vast information available about reference spectra in the scientific literature. However, as the technique is applicable to many science domains, searching for information about select x-ray spectroscopy spectra is impeded by the sheer number of publications. Moreover, useful information about the context of an experiment or figures presented in papers can be buried among the details, which takes time to assess. This work presents a scientific literature mining system that supports data acquisition, information extraction, and user interaction for referencing x-ray spectra identification and spectral interpretation. The goal is to provide efficient access to useful spectral data to researchers who may spend only a few days at a synchrotron light source. With this system, users browse a classification tree for papers arranged according to x-ray spectroscopic methods, chemical elements, and x-ray absorption spectroscopy edges. Relevant figures are extracted with sentences from the paper that explain them, known as ‘figure explanatory text.’ Notably, this system focuses on semantic aspects (logical analysis) to find figure explanatory text using deep contextualized word embeddings techniques and contains an interface to obtain labeled data from domain experts that is used to evaluate and improve the model.

Park, Gilchan (ORCID:0000000201536646)↗

Revealing Phase Heterogeneity in Vertically Aligned Nanocomposites via Plan-View Electron Energy Loss Spectroscopy

Hydrogen utilization in clean energy technologies is challenged by limited storage and transport within materials, owing to the complex hydrogen kinetics at interfaces [1]. Understanding these interfacial mechanisms at the nanoscale is crucial for developing improved materials for hydrogen applications, particularly proton-conducting fuel cells (PCFCs). Vertically aligned nanocomposites (VANs) grown by pulsed laser deposition (PLD) offer a unique platform for investigating the interfacial effects on hydrogen transport due to their well-defined interfaces parallel to the direction of charge transport [2-4]. To investigate hydrogen transport, the two phases within the VANs were chosen as BaZr 0.9 Y 0.1 O 3-x (BZY), a known proton conductor, and Pr 0.1 Ce 0.9 O 2-x (PCO), a mixed ionic-electronic conductor [5]. This PCO-BZY VANs architecture allows the investigation of how the interface between a proton conductor and a mixed conductor influences hydrogen transport. However, because of the small size of hydrogen, it is difficult to discern the nature of its interactions with interfaces from bulk measurements at the macroscale, thus necessitating nanoscale measurements [6]. Electron energy loss spectroscopy (EELS) allows for nanometer-resolution probing of the local atomic structure and chemistry at the BZY/PCO interface. In this study, plan-view analysis of PCO-BZY VANs films was employed to characterize the structure and phase distribution of the VANs and investigate the interface between the nanostructures. The films were imaged using scanning electron microscopy (SEM) in the Hitachi S-4800 SEM, collecting secondary electron images using mixed upper and lower detectors. Then, plan-view transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) EELS were employed using a JEOL ARM300 microscope operated at 300kV with a Gatan K3 GIF Continuum detector to study the distribution of the BZY and PCO phases through the film. As a result, spectrum images were acquired at a dispersion of 0.18eV per channel and denoised afterward by principal component analysis (PCA) method.

Griffin, Elizabeth [Northwestern University, Evans↗

Enabling the Acquisition of Electron Beam-Induced Current (EBIC) Images in Conventional SEM and STEM Instruments

Electron beam-induced current (EBIC) imaging is a well-established scanning electron microscope (SEM) technique used to analyze the behavior of microelectronic devices including solar cells. Recently, the application of EBIC imaging in an aberration-corrected scanning transmission electron microscope (STEM) has been demonstrated and offers great potential for the in situ study of electronic materials, correlating charge transport properties to atomic structural and elemental information. Here, this work presents two ways to implement EBIC imaging in conventional SEM and STEM systems: one relying on the instrument's inherent scanning and imaging electronics and the other involving third-party systems usually available in electron microscopes. The implementation of lock-in EBIC in systems equipped with a fast beam blanker is also described. In addition, this work shows and discusses the different mechanisms at play in EBIC imaging and their dependence on beam energy, sample impedance, and electrical measurement configuration, providing researchers with the basic information needed to apply the technique to their research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Methanopyrus kandleri topoisomerase V contains three distinct AP lyase active sites in addition to the topoisomerase active site

Topoisomerase V (Topo-V) is the only topoisomerase with both topoisomerase and DNA repair activities. The topoisomerase activity is conferred by a small alpha-helical domain, whereas the AP lyase activity is found in a region formed by 12 tandem helix-hairpin-helix ((HhH) 2 ) domains. Although it was known that Topo-V has multiple repair sites, only one had been mapped. Here, we show that Topo-V has three AP lyase sites. The atomic structure and Small Angle X-ray Scattering studies of a 97 kDa fragment spanning the topoisomerase and 10 (HhH) 2 domains reveal that the (HhH) 2 domains extend away from the topoisomerase domain. A combination of biochemical and structural observations allow the mapping of the second repair site to the junction of the 9th and 10th (HhH) 2 domains. The second site is structurally similar to the first one and to the sites found in other AP lyases. The 3rd AP lyase site is located in the 12th (HhH) 2 domain. The results show that Topo-V is an unusual protein: it is the only known protein with more than one (HhH) 2 domain, the only known topoisomerase with dual activities and is also unique by having three AP lyase repair sites in the same polypeptide.

59 BASIC BIOLOGICAL SCIENCES↗