Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

NO$\nu$A Data Acquisition Software System

NO{nu}A is an accelerator-based neutrino oscillation experiment which has a great potential to measure the last unknown mixing angle {theta}{sub 13}, the neutrino mass hierarchy, and the CP-violation phase in lepton sector with (1) 700 kW beam, (2) 14 mrad off the beam axis, (3) 810 km long baseline. The Near Detector on the Surface is fully functioning and taking both NuMI and Booster beam data. The far detector building achieved beneficial occupancy on April 13. This proceeding will focus on the DAQ software system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Upgrade Path from Legacy VME to VXS Dual Star Connectivity for Large Scale Data Acquisition and Trigger Systems

New instrumentation modules have been designed by Jefferson Lab and to take advantage of the higher performance and elegant backplane connectivity of the VITA 41 VXS standard. These new modules are required to meet the 200KHz trigger rates envisioned for the 12GeV experimental program. Upgrading legacy VME designs to the high speed gigabit serial extensions that VXS offers, comes with significant challenges, including electronic engineering design, plus firmware and software development issues. This paper will detail our system design approach including the critical system requirement stages, and explain the pipeline design techniques and selection criteria for the FPGA that require embedded Gigabit serial transceivers. The entire trigger system is synchronous and operates at 250MHz clock with synchronization signals, and the global trigger signals distributed to each front end readout crate via the second switch slot in the 21 slot, dual star VXS backplane. The readout of the buffered detector signals relies on 2eSST over the standard VME64x path at >200MB/s. We have achieved 20Gb/s transfer rate of trigger information within one VXS crate and will present results using production modules in a two crate test configuration with both VXS crates fully populated. The VXS trigger modules that reside in the front end crates, will be ready for production orders by the end of the 2011 fiscal year. VXS Global trigger modules are in the design stage now, and will be complete to meet the installation schedule for the 12GeV Physics program.

99 GENERAL AND MISCELLANEOUS↗

3-D Radiological Data Acquisition, Visualization and Modeling - 20211

The U.S. Army Corps of Engineers (USACE) was tasked to investigate and remediate low activity radiological contamination from research and production of the nation's first nuclear weapons at the former DuPont Chambers Works Formerly Utilized Sites Remedial Action Program (FUSRAP) site (DuPont). The DuPont site had several buildings used for the Manhattan project that were demolished in the 1940's and 1950's apparently using heavy earthmoving equipment. Some of the contaminated rubble from the demolition appears to have been spread out by this equipment resulting in somewhat random scattering of radiologically contaminated soil and debris along with aqueous spills. Traditional investigative methods such as soil borings, test pits and 2-dimensional gamma walkovers were only partially successful in delineating the radiological contamination at the site. It was feared that even 'chasing' the contamination during remediation would miss contamination if the demolition resulted in discontinuous trails of radiologically contaminated soils. In evaluating the data generated over the interceding decades, the USACE determined that a better method to collect and process the remedial action radiological data was needed to enable the project team to optimize predictive planning and meet documentation expectations. The purpose of this paper is to provide an overview of the effort and progress to combine and organize radiological survey methods into a highly flexible sampling, modeling, and decision analysis approach that emphasizes the quality of decision-making during remediation. This innovative system blends multiple tools to develop a methodology that can extend MARRSIM [1] into the subsurface and provide tools that can be applied to other sites. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trials, tribulations, and pitfalls using commercial instruments for data acquisition

Brookhaven National Laboratory's Relativistic Heavy Ion Collider (RHIC) uses many commercially available instruments - for example spectrum analyzers, oscilloscopes, digital volt meters, signal generators - as integral parts of instrumentation and control systems. Typically these systems are remotely controlled. Using commercial instruments has many benefits. Manufactures have the skill, knowledge, and experience to produce high quality products. The price performance ratio is hard to duplicate. There are also disadvantages. Proprietary interfaces, single platform drivers, and reliable operation provide challenges for implementation and unattended operation. Several of the systems used at RHIC will be described. Their issues and solutions will be presented.

43 PARTICLE ACCELERATORS↗

Activity coefficient acquisition with thermodynamics–informed active learning for phase diagram construction

This work explores the use of thermodynamics-informed Gaussian processes (GPs) and active learning (AL) to model activity coefficients and construct phase diagrams. Relying on synthetic data generated from an excess Gibbs energy model, GPs were found to accurately describe the activity coefficients of several binary mixtures across large composition and temperature ranges. Moreover, GPs could estimate their own uncertainty and identify composition/temperature regions where activity coefficient data provide the most information to the models. This was leveraged to build AL algorithms targeted at modeling phase equilibria. In many cases, a single active-learning-acquired data point was sufficient to describe the phase diagrams studied. Lastly, the ability of AL to greatly reduce the amount of data needed to obtain accurate models was further verified on experimental case studies, namely individual ion activity coefficients, the solid–liquid and vapor–liquid equilibrium of deep eutectic solvents, and phase equilibria in ternary mixtures.

25 ENERGY STORAGE↗

Restoration and Modification of Magnetosome Biosynthesis by Internal Gene Acquisition in a Magnetotactic Bacterium

We report that the Integration of a large-sized DNA fragment into a chromosome is an important strategy for characterization of cellular functions in microorganisms. Magnetotactic bacteria synthesize intracellular organelles comprising membrane-bound single crystalline magnetite, also referred to as magnetosomes. Magnetosomes have gained interest in both scientific and engineering sectors as they can be utilized as a material for biomedical and nanotechnological applications. Although genetic engineering of magnetosome biosynthesis mechanism has been investigated, the current method requires cumbersome gene preparation processes. Here, the chromosomal integration of a plasmid containing ≈27 magnetosome genes (≈26 kbp region) in a non-magnetic mutant of Magnetospirillum magneticum AMB-1 using a broad-host-range plasmid is shown. The genome sequencing of gene-complemented strains reveals the chromosomal integration of the plasmid with magnetosome genes at a specific site, most likely by catalysis of an endogenous transposase. Magnetosome production is successfully enhanced by integrating a variation of magnetosome gene operons in the chromosome. This chromosomal integration mechanism will allow the design of functional magnetosomes de novo and M. magneticum AMB-1 may be used as a chassis for the designed magnetosome production.

59 BASIC BIOLOGICAL SCIENCES↗

Long‐term continuous cropping affects ecoenzymatic stoichiometry of microbial nutrient acquisition: a case study from a Chinese Mollisol

Abstract BACKGROUND Soil‐ and plant‐produced extracellular enzymes drive nutrient cycling in soils and are assumed to regulate supply and demand for carbon (C) and nutrients within the soil. Thus, agriculture management decisions that alter the balance of plant and supplemental nutrients should directly alter extracellular enzyme activities (EEAs), and EEA stoichiometry in predictable ways. We used a 12‐year experiment that varyied three major continuous grain crops (wheat, soybean, and maize), each crossed with mineral fertilizer (WCF, SCF and MCF, respectively) or not fertilized (WC, SC and MC, respectively, as controls). In response, we measured the phospholipid fatty acids (PLFAs), EEAs and their stoichiometry to examine the changes to soil microbial nutrient demand under the continuous cropping of crops, which differed with respect to the input of plant litter and fertilizer. RESULTS Fertilizer generally decreased soil microbial biomass and enzyme activity compared to non‐fertilized soil. According to enzyme stoichiometry, microbial nutrient demand was generally C‐ and phosphorus (P)‐limited, but not nitrogen (N)‐limited. However, the degree of microbial resource limitation differed among the three crops. The enzymatic C:N ratio was significantly lower by 13.3% and 26.8%, whereas the enzymatic N:P ratio was significantly higher by 9.9% and 42.4%, in MCF than in WCF and SCF, respectively. The abundances of arbuscular mycorrhizal fungi and aerobic PLFAs were significantly higher in MCF than in WCF and SCF. CONCLUSION These findings are crucial for characterizing enzymatic activities and their stoichiometries that drive microbial metabolism with respect to understanding soil nutrient cycles and environmental conditions and optimizing practices of agricultural management. © 2021 Society of Chemical Industry.

Chen, Xu↗

Whole-Body Magnetic Resonance Angiography with Additional Steady-State Acquisition of the Infragenicular Arteries in Patients with Peripheral Arterial Disease

The purpose of this investigation was to determine if addition of infragenicular steady-state (SS) magnetic resonance angiography (MRA) to first-pass imaging improves diagnostic performance compared with first-pass imaging alone in patients with peripheral arterial disease (PAD) undergoing whole-body (WB) MRA. Twenty consecutive patients with PAD referred to digital-subtraction angiography (DSA) underwent WB-MRA. Using a bolus-chase technique, first-pass WB-MRA was performed from the supra-aortic vessels to the ankles. The blood-pool contrast agent gadofosveset trisodium was used at a dose of 0.03 mmol/kg body weight. Ten minutes after injection of the contrast agent, high-resolution (0.7-mm isotropic voxels) SS-MRA of the infragenicular arteries was performed. Using DSA as the 'gold standard,' sensitivities and specificities for detecting significant arterial stenoses ({>=}50% luminal narrowing) with first-pass WB-MRA, SS-MRA, and combined first-pass and SS-MRA were calculated. Kappa statistics were used to determine intermodality agreement between MRA and DSA. Overall sensitivity and specificity for detecting significant arterial stenoses with first-pass WB-MRA was 0.70 (95% confidence interval 0.61 to 0.78) and 0.97 (0.94 to 0.99), respectively. In first-pass WB-MRA, the lowest sensitivity was in the infragenicular region, with a value of 0.42 (0.23 to 0.63). Combined analysis of first-pass WB-MRA and SS-MRA increased sensitivity to 0.81 (0.60 to 0.93) in the infragenicular region, with specificity of 0.94 (0.88 to 0.97). Sensitivity and specificity for detecting significant arterial stenoses with isolated infragenicular SS-MRA was 0.47 (0.27 to 0.69) and 0.86 (0.78 to 0.91), respectively. Intermodality agreement between MRA and DSA in the infragenicular region was moderate for first-pass WB-MRA ({kappa} = 0.49), fair for SS-MRA ({kappa} = 0.31), and good for combined first-pass/SS-MRA ({kappa} = 0.71). Addition of infragenicular SS-MRA to first-pass WB MRA improves diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗