Applications of Hyporheic Zone Sampling for Assessing VOC Plume Engineered Remediation and Natural Attenuation Effectiveness - 20414

Determining the efficacy of engineered remedial actions and/or natural attenuation as an acceptable EPA Record of Decision (ROD) must address long-term temporal and spatial variability. Since final plume downslope destinations are aquifers and related surface streams and rivers, hyporheic zone sampling is essential. Comprehensive hyporheic sampling documents plume groundwater remediation prior to upwelling into stream benthic strata and natural attenuation within this dynamic zone itself. Our intensive sampling of the Savannah River Site (SRS) Chemical, Metals, and Pesticides (CMP) Pits VOC plume-fringe from 2005 to 2018 documented PCE natural attenuation and effectiveness of In Situ Thermal Treatment (ISTT). Most plume hyporheic upwelling was delimited to a 20 m inflow reach along Pen Branch. Our study utilized corroborative sampling methodologies: ambient hole-water grab samples: passive diffusion bags (PDB); and hole-core sediment samples to confirm station to station spatial and temporal trends. VOC hot spot detections were confirmed from both groundwater and soil core samples. VOC pathways through the Pen Branch hyporheic zone were assessed at hole-installation using sequential soil samples from augered cores and grab-samples of hole-bottom water. Longer term, composite water samples were collected from PDBs deployed for a minimum two-week equilibration period. Soil samples were collected from the 15 and 65 cm core levels in December 2017 and June 2018 at six stations. Additional core depths of 40 and 85 cm were sampled in June 2018 at the highest VOC station (5DB80). All samples were analyzed in an EPA certified lab by purge and trap GC-MS. Effectiveness of previous ISTT and soil vapor extraction (SVE) for this CMP Pits PCE plume, was clearly documented by significant downward trends in VOC at hyporheic zone stations prior to December 2015. Achieving final stage conversions of PCE daughter products to ethene and CO{sub 2} may be limited depending upon suitable interactions between hyporheic zone sediment morphology, hydrology, and redox conditions. Because declines in VOC daughter products at our hyporheic stations may also be caused by physical actions of dilution and dispersion rather than true biochemical dechlorination, full quantification of natural attenuation requires the use of compound-specific isotope ratio analysis (CSIA) and microbial 16S rRNA with qPCR. To assist these next-phase efforts, a natural attenuation index (NAI) was used to help produce quicker, more cost-effective decision making for locating CSIA and microbial sampling efforts. The NAI used natural logarithm transformed GC-MS results for station VOC degradation compounds versus VOC parent compounds. Wide differences were observed between stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MODELING THE IMPACT OF ELEVATED MERCURY IN DEFENSE WASTE PROCESSING FACILITY MELTER FEED ON THE MELTER OFF-GAS SYSTEM-PRELIMINARY REPORT

The Defense Waste Processing Facility (DWPF) is currently evaluating an alternative Chemical Process Cell (CPC) flowsheet to increase throughput. It includes removal of the steam-stripping step, which would significantly reduce the CPC processing time and lessen the sampling needs. However, its downside would be to send 100% of the mercury that comes in with the sludge straight to the melter. For example, the new mercury content in the Sludge Batch 5 (SB5) melter feed is projected to be 25 times higher than that in the SB4 with nominal steam stripping of mercury. This task was initiated to study the impact of the worst-case scenario of zero-mercury-removal in the CPC on the DWPF melter offgas system. It is stressed that this study is intended to be scoping in nature, so the results presented in this report are preliminary. In order to study the impact of elevated mercury levels in the feed, it is necessary to be able to predict how mercury would speciate in the melter exhaust under varying melter operating conditions. A homogeneous gas-phase oxidation model of mercury by chloride was developed to do just that. The model contains two critical parameters pertaining to the partitioning of chloride among HCl, Cl, Cl{sub 2}, and chloride salts in the melter vapor space. The values for these parameters were determined at two different melter vapor space temperatures by matching the calculated molar ratio of HgCl (or Hg{sub 2}Cl{sub 2}) to HgCl{sub 2} with those measured during the Experimental-Scale Ceramic Melter (ESCM) tests run at the Pacific Northwest National Laboratory (PNNL). The calibrated model was then applied to the SB5 simulant used in the earlier flowsheet study with an assumed mercury stripping efficiency of zero; the molar ratio of Cl-to-Hg in the resulting melter feed was only 0.4, compared to 12 for the ESCM feeds. The results of the model run at the indicated melter vapor space temperature of 650 C (TI4085D) showed that due to excessive shortage of chloride, only 6% of the mercury fed is expected to get oxidized, mostly as HgCl, while the remaining mercury would exist either as elemental mercury vapor (90%) or HgO (4%). Noting that the measured chloride level in the SB5 qualification sample was an order of magnitude lower than that used in the SB5 simulant, the degree of chloride shortage will be even greater. As a result, the projected level of HgCl in the actual SB5 melter exhaust will be even lower than 6% of the total mercury fed, while that of elemental mercury is likely to be greater than 90%. The homogeneous oxidation of mercury in the off-gas was deemed to be of primary importance based on the postulation that mercury and other volatile salts form submicron sized aerosols upon condensation and thus remain largely in the gas stream downstream of the quencher where they can deposit in the off-gas lines, Steam-Atomized Scrubbers (SAS), and High-Efficiency Mist Eliminator (HEME). Formation of these submicron semi-volatile salts in the condensate liquid is considered to be unlikely, so the liquid phase reactions were considered to be less important. However, subsequent oxidation of mercury in the liquid phase in the off-gas system was examined in a simplified model of the off-gas condensate. It was found that the condensate chemistry was consistent with further oxidation of elemental mercury to Hg{sub 2}Cl{sub 2} and conversion of HgO to chlorides. The results were consistent with the available experimental data. It should also be noted that the model predictions presented in this report do not include any physically entrained solids, which typically account for much of the off-gas carryover on a mass basis. The high elemental mercury vapor content predicted at the DWPF Quencher inlet means that physically entrained solids could provide the necessary surface onto which elemental mercury vapor could condense, thereby coating the solids as well as the internal surfaces of the off-gas system with mercury. Clearly, there are many process benefits to be gained by removing the steam-stripping step from the CPC cycle. The goal of this task was to study what adverse impact the zero-mercury-removal scenario would have on the DWPF melter off-gas system operation. It is stressed again that this study was intended to be scoping in nature, so the results presented in this report are preliminary. Any further substantiation of these results for actual implementation into the DWPF flowsheet would require an in-depth modeling study of all three reaction zones, including the aqueous-phase reactions in the quencher, OGCT, Steam Atomized Scrubber (SAS), and off-gas condenser with recirculated condensate, and the proof-of-principle experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MODELING THE IMPACT OF ELEVATED MERCURY IN DEFENSE WASTE PROCESSING FACILITY MELTER FEED ON THE MELTER OFF-GAS SYSTEM - PRELIMINARY REPORT

The Defense Waste Processing Facility (DWPF) is currently evaluating an alternative Chemical Process Cell (CPC) flowsheet to increase throughput. It includes removal of the steam-stripping step, which would significantly reduce the CPC processing time and lessen the sampling needs. However, its downside would be to send 100% of the mercury that come in with the sludge straight to the melter. For example, the new mercury content in the Sludge Batch 5 (SB5) melter feed is projected to be 25 times higher than that in the SB4 with nominal steam stripping of mercury. This task was initiated to study the impact of the worst-case scenario of zero-mercury-removal in the CPC on the DWPF melter off-gas system. It is stressed that this study is intended to be scoping in nature, so the results presented in this report are preliminary. In order to study the impact of elevated mercury levels in the feed, it is necessary to be able to predict how mercury would speciate in the melter exhaust under varying melter operating conditions. A homogeneous gas-phase oxidation model of mercury by chloride was developed to do just that. The model contains two critical parameters pertaining to the partitioning of chloride among HCl, Cl, Cl{sub 2}, and chloride salts in the melter vapor space. The values for these parameters were determined at two different melter vapor space temperatures by matching the calculated molar ratio of HgCl (or Hg{sub 2}Cl{sub 2}) to HgCl{sub 2} with those measured during the Experimental-Scale Ceramic Melter (ESCM) tests run at the Pacific Northwest National Laboratory (PNNL). The calibrated model was then applied to the SB5 simulant used in the earlier flowsheet study with an assumed mercury stripping efficiency of zero; the molar ratio of Cl-to-Hg in the resulting melter feed was only 0.4, compared to 12 for the ESCM feeds. The results of the model run at the indicated melter vapor space temperature of 650 C (TI4085D) showed that due to excessive shortage of chloride, only 6% of the mercury fed is expected to get oxidized, mostly as HgCl, while the remaining mercury would exist either as elemental mercury vapor (90%) or HgO (4%). Noting that the measured chloride level in the SB5 qualification sample was an order of magnitude lower than that used in the SB5 simulant, the degree of chloride shortage will be even greater. As a result, the projected level of HgCl in the actual SB5 melter exhaust will be even lower than 6% of the total mercury fed, while that of elemental mercury is likely to be greater than 90%. The homogeneous oxidation of mercury in the off-gas was deemed to be of primary importance based on the postulation that mercury and other volatile salts form submicron sized aerosols upon condensation and thus remain largely in the gas stream downstream of the quencher where they can deposit in the off-gas lines, Steam-Atomized Scrubbers (SAS), and High-Efficiency Mist Eliminator (HEME). Formation of these submicron semi-volatile salts in the condensate liquid is considered to be unlikely, so the liquid phase reactions were considered to be less important. However, subsequent oxidation of mercury in the liquid phase in the off-gas system was examined in a simplified model of the off-gas condensate. It was found that the condensate chemistry was consistent with further oxidation of elemental mercury to Hg{sub 2}Cl{sub 2} and conversion of HgO to chlorides. The results were consistent with the available experimental data. It should also be noted that the model predictions presented in this report do not include any physically entrained solids, which typically account for much of the off-gas carryover on a mass basis. The high elemental mercury vapor content predicted at the DWPF Quencher inlet means that physically entrained solids could provide the necessary surface onto which elemental mercury vapor could condense, thereby coating the solids as well as the internal surfaces of the off-gas system with mercury. Clearly, there are many process benefits to be gained by removing the steam-stripping step from the CPC cycle. The goal of this task was to study what adverse impact the zero-mercury-removal scenario would have on the DWPF melter off-gas system operation. It is stressed again that this study was intended to be scoping in nature, so the results presented in this report are preliminary. Any further substantiation of these results for actual implementation into the DWPF flowsheet would require an in-depth modeling study of all three reaction zones, including the aqueous-phase reactions in the quencher, OGCT, Steam Atomized Scrubber (SAS), and off-gas condenser with recirculated condensate, and the proof-of-principle experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Polymer Dissolution and Solution Blow Spinning Coupled with Solvent Recovery for Expanded Polystyrene Recycling

With increasing buoyant plastic wastes entering into oceans and food chains, the disposal and recycling of waste expanded polystyrene (WPS) has become an imminent environmental problem. In this work, a recycling scheme for waste WPS is proposed that combines the polymer dissolution recycling approach with the solution blow spinning (SBS) technique that facilitates the high-volume bulk WPS transportation and the value-addition of WPS to nanofibers. Solvent selection is critical for an economical and environmentally favorable implementation of this recycling scheme at large scale. Here, the effect of three solvents with distinct volatility, viz. ethyl acetate, toluene, and N, N- dimethylformamide (DMF) have been studied on the fiber formation and the ease of the solvent recovery, in order to ascertain the practicability of using these solvents for the recycling process. The fiber formation is experimentally demonstrated for the WPS-solvent systems using the SBS process. It is found that the fiber morphology varies for the different WPS-solvent systems. A solvent recovery scheme to recover the solvent from the air-solvent mixture (leaving SBS) is evaluated using ASPEN Plus simulation. The % solvent recovery is determined as a function of the required energy input for different process parameters including compressor pressure and air to polymer solution feed ratio. The simulation studies show that a lower feed air to polymer solution ratio and higher compressor pressure are required to obtain > 70% solvent recovery for high volatility solvents (ethyl acetate and toluene) with lower energy input and optimal operating condenser temperature (~ 0 °C). Conversely, significant solvent losses occur in the SBS process with a lower volatility solvent (DMF), leading to a lower solvent recovery for the whole process. The % DMF recovery can be improved upon by using higher feed air to polymer solution ratio although at a higher energy penalty.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermoelectric generators incorporating phase-change materials for waste heat recovery from engine exhaust

Thermoelectric devices, intended for placement in the exhaust of a hydrocarbon fuelled combustion device and particularly suited for use in the exhaust gas stream of an internal combustion engine propelling a vehicle, are described. Exhaust gas passing through the device is in thermal communication with one side of a thermoelectric module while the other side of the thermoelectric module is in thermal communication with a lower temperature environment. The heat extracted from the exhaust gasses is converted to electrical energy by the thermoelectric module. The performance of the generator is enhanced by thermally coupling the hot and cold junctions of the thermoelectric modules to phase-change materials which transform at a temperature compatible with the preferred operating temperatures of the thermoelectric modules. In a second embodiment, a plurality of thermoelectric modules, each with a preferred operating temperature and each with a uniquely-matched phase-change material may be used to compensate for the progressive lowering of the exhaust gas temperature as it traverses the length of the exhaust pipe.

30 DIRECT ENERGY CONVERSION↗

Degradation of triclosan and triclocarban and formation of transformation products in activated sludge using benchtop bioreactors

Highlights: • Benchtop bioreactors were run with activated sludge for 122 – 196 h. • Extended HRT and SRT and increased temperatures on TCS, TCC, and their byproducts were studied. • Prolonged HRT and SRT resulted in more efficient TCS and TCC removal. • Increases in reactor temperature improved TCS and TCC degradation. • Significant MeTCS formation was observed. Benchtop bioreactors were run aerobically with activated sludge samples collected from a large municipal wastewater treatment plant (WWTP) to understand how increased hydraulic retention time (HRT), sludge retention time (SRT), and varying treatment temperatures (21 °C and 30 °C) impact concentrations of the endocrine disrupting antimicrobials triclosan (TCS), triclocarban (TCC), and their transformation products. Samples from the reactors were collected periodically over a 122–196 h period and the solid and liquid fraction were separately quantitated for TCS, TCC, and methyltriclosan (MeTCS) and scanned qualitatively for six other transformation products. Results indicated that TCS, TCC and MeTCS were predominately associated with the solids fraction of the activated sludge with only nominal concentrations in the liquids fraction. TCS was degraded in the solids fraction, with increased rates at 30 °C (−0.0224 ± 0.007 h{sup −1}) when compared to reactors run at 21 °C (− 0.0170 ± 0.003 h{sup −1}). Conversely, TCC concentrations did not significantly change in solids samples from reactors run at 21 °C, while an increase in reactor temperature to 30 °C resulted in TCC degradation at an average rate of − 0.0158 ± 0.012 h{sup −1}. Additionally, MeTCS formation in the solids fraction was observed in three out of four reactors run - indicating a notable transformation of TCS. Qualitative appearance of 2,4-dichlorophenol and 4-chloroanaline was observed in the liquids fraction of all reactor samples. The remaining four qualitatively scanned compounds were not detected. These experiments demonstrate that increased HRT, SRT, and temperature result in enhanced removal of TCS and TCC from wastewater during the activated sludge process. Furthermore, a substantial formation of TCS into MeTCS was observed.

54 ENVIRONMENTAL SCIENCES↗

Diversion Path Analysis: A Proposed Methodology to Develop an MC&A Approach for Liquid-Fueled Molten Salt Reactors

Nuclear material control and accounting (MC&A) is a critical element of both the US Nuclear Regulatory Commission (NRC) and US Department of Energy (DOE)’s domestic safeguards and security requirements. NRC licensees are required, under Title 10 of the Code of Federal Regulations (10 CFR) Part 74 to establish and maintain an MC&A program that captures and records the quantities and locations of special nuclear material (SNM) at the facility. Along with physical protection, MC&A is a key element of domestic nuclear material safeguards that enables the NRC to ensure that SNM is controlled and accounted for. SNM, per 10 CFR Part 74, refers to plutonium, 233 U, and uranium enriched in the isotope 233 U or 235 U, but does not include source material. Periodic physical inventories, coupled with material balance evaluations, are effective and demonstrated tools to account for and detect theft or diversion of SNM in facilities containing SNM in bulk material form (i.e., not in discrete, countable items). Historically in the United States, these types of facilities have included fuel fabrication, conversion, and enrichment facilities. In comparison, reactors have relied on item counting of assemblies and control of SNM while in containment (e.g., a sealed reactor pressure vessel) because, to date, reactor fuel has been in item form. In liquid-fueled molten salt reactors (MSRs), unlike traditional light water reactors (LWRs) or bulk facilities, bulk SNM quantities can change significantly during operation as a result of depletion and transmutation. This introduces challenges to the use of traditional periodic physical inventories and material balance evaluations to detect theft or diversion of SNM in reactors that use SNM in bulk material form. Liquid-fueled (i.e., salt-fueled) MSR facilities are MSRs that use SNM within a salt eutectic as the fuel. The SNM is in a bulk material form any time it is outside of fresh or spent fuel storage containers. Some examples of when SNM will be in bulk form in the facility are during addition of fuel to the reactor system, while fuel is circulating in operation, and while fuel is in a drain tank. Periodic physical inventories and material balance evaluations can likely be effectively applied to many portions of an MSR facility, including all areas where depletion and transmutation are not significantly changing the quantities of SNM within the control area. Within an MSR facility, this would include fresh fuel receipt and loading, waste streams that may contain SNM, irradiated fuel storage outside of the reactor core, and any irradiated fuel processing that may happen after SNM has been removed from the reactor. All of these process steps could rely on measurements of SNM quantities compared with documented inventories. Any discrepancies from predicted (i.e., book) inventories and measured inventories could be quantified as inventory differences, consistent with traditional MC&A guidance from the NRC (e.g., in NUREG-1065 Revision 2, NUREG-2159 Revision 1, and RG 5.29 Revision 2). Within the reactor system, additions and removals to the book inventory include depletion of the SNM (e.g., fission of 235 U), which complicates the use of physical inventories. SNM control, however, can also likely be effectively applied to detect theft of SNM throughout a liquid-fueled MSR facility. To complement these approaches, prior technical reports have identified that a diversion path analysis may be a useful, risk-informed, and performance-based tool to determine suitable elements of an MC&A approach for the reactor system within a liquid-fueled MSR facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Innovative Strategy For Long Term Monitoring Of Metal And Radionuclide Plumes

Many government and private industry sites that were once contaminated with radioactive and chemical wastes cannot be cleaned up enough to permit unrestricted human access. The sites will require long term management, in some cases indefinitely, leaving site owners with the challenge of protecting human health and environmental quality at these "legacy" sites. Long-term monitoring of groundwater contamination is one of the largest projected costs in the life cycle of environmental management at the Savannah River Site, the larger DOE complex, and many large federal and private sites. There is a need to optimize the performance and manage the cost of long term surveillance and monitoring at their sites. Currently, SRNL is initiating a pilot field test using alternative protocols for long term monitoring of metals and radionuclides. A key component of the approach is that monitoring efforts are focused on measurement of low cost metrics related to hydrologic and chemical conditions that control contaminant migration. The strategy combines careful monitoring of hydrologic boundary conditions with measurement of master variables such as chemical surrogates along with a smaller number of standard well analyses. In plumes contaminated with metals, master variables control the chemistry of the groundwater system, and include redox variables (ORP, DO, chemicals), pH, specific conductivity, biological community (breakdown/decay products), and temperature. Significant changes in these variables will result in conditions whereby the plume may not be stable and therefore can be used to predict possible plume migration. Conversely, concentration measurements for all types of contaminants in groundwater are a lagging indicator plume movement - major changes contaminant concentrations indicate that contamination has migrated. An approach based on measurement of master variables and explicit monitoring of hydrologic boundary conditions combined with traditional metrics should lead to improved monitoring while simultaneously reducing costs. This paradigm is being tested at the SRS F-Area where an innovative passive remedial system is being monitored and evaluated over the long term prior to traditional regulatory closure. Contaminants being addressed at this site are uranium, strontium-90, iodine-129, and tritium. We believe that the proposed strategies will be more effective in early identification of potential risks; these strategies will also be cost effective because controlling variables are relatively simple to measure. These variables also directly reflect the evolution of the plume through time, so that the monitoring strategy can be modified as the plume 'ages'. This transformational long-term monitoring paradigm will generate large cost savings to DOE, other federal agencies and industry and will provide improved performance and leading indicators of environmental management performance.

54 ENVIRONMENTAL SCIENCES↗

Sustained Recycle in Light Water and Sodium-Cooled Reactors

From a physics standpoint, it is feasible to sustain recycle of used fuel in either thermal or fast reactors. This paper examines multi-recycle potential performance by considering three recycling approaches and calculating several fuel cycle parameters, including heat, gamma, and neutron emission of fresh fuel; radiotoxicity of waste; and uranium utilization. The first recycle approach is homogeneous mixed oxide (MOX) fuel assemblies in a light water reactor (LWR). The transuranic portion of the MOX was varied among Pu, NpPu, NpPuAm, or all-TRU. (All-TRU means all isotopes through Cf-252.) The Pu case was allowed to go to 10% Pu in fresh fuel, but when the minor actinides were included, the transuranic enrichment was kept below 8% to satisfy the expected void reactivity constraint. The uranium portion of the MOX was enriched uranium. That enrichment was increased (to as much as 6.5%) to keep the fuel critical for a typical LWR irradiation. The second approach uses heterogeneous inert matrix fuel (IMF) assemblies in an LWR - a mix of IMF and traditional UOX pins. The uranium-free IMF fuel pins were Pu, NpPu, NpPuAm, or all-TRU. The UOX pins were limited to 4.95% U-235 enrichment. The number of IMF pins was set so that the amount of TRU in discharged fuel from recycle N (from both IMF and UOX pins) was made into the new IMF pins for recycle N+1. Up to 60 of the 264 pins in a fuel assembly were IMF. The assembly-average TRU content was 1-6%. The third approach uses fast reactor oxide fuel in a sodium-cooled fast reactor with transuranic conversion ratio of 0.50 and 1.00. The transuranic conversion ratio is the production of transuranics divided by destruction of transuranics. The FR at CR=0.50 is similar to the CR for the MOX case. The fast reactor cases had a transuranic content of 33-38%, higher than IMF or MOX.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Processes and electron flow in a microbial electrolysis cell bioanode fed with furanic and phenolic compounds

We report that furanic and phenolic compounds are problematic compounds resulting from the pretreatment of lignocellulosic biomass for biofuel production. Microbial electrolysis cell (MEC) is a promising technology to convert furanic and phenolic compounds to renewable H 2 . The objective of the research presented here was to elucidate the processes and electron equivalents flow during the conversion of two furanic (furfural, FF; 5-hydroxymethyl furfural, HMF) and three phenolic (syringic acid, SA; vanillic acid, VA; 4-hydroxybenzoic acid, HBA) compounds in the MEC bioanode. Cyclic voltammograms of the bioanode demonstrated that purely electrochemical reactions in the biofilm attached to the electrode were negligible. Instead, microbial reactions related to the biotransformation of the five parent compounds (i.e., fermentation followed by exoelectrogenesis) were the primary processes resulting in the electron equivalents flow in the MEC bioanode. A mass-based framework of substrate utilization and electron flow was developed to quantify the distribution of the electron equivalents among the bioanode processes, including biomass growth for each of the five parent compounds. Using input parameters of anode efficiency and biomass observed yield coefficients, it was estimated that more than 50% of the SA, FF, and HMF electron equivalents were converted to current. In contrast, only 12 and 9% of VA and HBA electron equivalents, respectively, resulted in current production, while 76 and 79% remained as fermentation end products not further utilized in exoelectrogenesis. For all five compounds, it was estimated that 10% of the initially added electron equivalents were used for fermentative biomass synthesis, while 2 to 13% were used for exoelectrogenic biomass synthesis. Finally, the proposed mass-based framework provides a foundation for the simulation of bioanode processes to guide the optimization of MECs converting biomass-derived waste streams to renewable H 2 .

09 BIOMASS FUELS↗

Time dependent chlorination of CeO 2 , La 2 O 3 and Nd 2 O 3 by ZrCl 4 dissolved in eutectic LiCl–KCl

Partial chlorination of CeO 2 , La 2 O 3 , and Nd 2 O 3 was achieved using ZrCl 4 dissolved in molten LiCl-KCl at 450°C over a period of 4-5 hr. ZrCl 4 was pre-volatilized into an argon stream to maintain a constant vapor pressure for equilibration with the salt. This approach was effective at maintaining the ZrCl 4 concentration at the solubility limit of 1.3 mol% in the molten salt throughout the duration of two of the chlorination experiments and within about 60% of the solubility limit in the third experiment. Based on the analysis of salt samples, fractional conversion after four hours of reaction for CeO 2 , and five hours for La 2 O 3 , and Nd 2 O 3 were calculated to be 0.97, 0.28, and 0.65 respectively. Assuming a shrinking core diffusion-limited model, the diffusivity of ZrCl 4 through the hypothesized ZrO 2 layer was calculated for the chlorination of CeO 2 , La 2 O 3 , and Nd 2 O 3 were 1.76 x 10 -10 cm 2 /sec, 7.85 x 10 -12 cm 2 /sec, and 7.42 x 10 -12 cm 2 /sec, respectively. Given the extremely low values calculated for diffusivity, it was concluded that the process is chemical reaction rate limited and that a complete reaction of each rare earth oxide could be achieved. Furthermore, a chemically controlled shrinking core model was shown to also fit the experimental data closely.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of network connectivity on behavior of synthetic Broborg hillfort glasses

There is wide industrial interest in developing robust models of long-term (>100 years) glass durability. Archeological glass analogs, glasses of similar composition, and alteration conditions to those being tested for durability can be used to evaluate and inform such models. Two such analog glasses from a 1500-year-old vitrified hillfort near Uppsala, Sweden have previously been identified as potential analogs for low concentration Fe-bearing aluminosilicate nuclear waste glasses. However, open questions remain regarding the melting environment from which these historic glasses were formed and the effect of these conditions on their chemical durability. A key factor to answering the previous melting and durability questions is the redox state of Fe in the starting and final materials. Past work has shown that the melting conditions of a glass-forming melt may influence the redox ratio value (Fe +3 /ΣFe), a measure of a glass's redox state, and both melting conditions and the redox ratio may influence the glass alteration behavior. Synthetic analogs of the hillfort glasses have been produced using either fully oxidized or reduced Fe precursors to address this question. In this study, the melting behavior, glass transition temperature, oxidation state, network structure, and chemical durability of these synthesized glass analogs is presented. Resulting data suggests that the degree of network connectivity as impacted by the oxidation state of iron impacted the behavior of the glass-forming melt but in this case does not affect the chemical durability of the final glass. Glasses with a lower degree of melt connectivity were found to have a lower viscosity, resulting in a lower glass transition temperature and softening temperature, as well as in a lower temperature of foam onset and temperature of foam maximum. This lower degree of network connectivity most likely played a more significant role in accelerating the conversion of batch chemicals into glass than the presence of water vapor in the furnace's atmosphere. Future work will focus on using the results from this work with outcomes from other aspects of this project to evaluate long-term glass alteration models.

36 MATERIALS SCIENCE↗

Carbon nanotube thermoelectric devices by direct printing: Toward wearable energy converters

Thermoelectric devices convert thermal energy to electrical energy and are particularly well-suited for energy harvesting from waste heat. Even as the number of electronic devices used in daily life proliferates, technical advances diminish the average power such devices require to perform a given function. Here, localized thermal gradients that abound in our living environments, despite having modest energy densities, are therefore becoming increasingly viable and attractive to power such devices. With this motivation, we report the design, fabrication, and characterization of single-wall carbon nanotube thermoelectric devices (CNT-TDs) on flexible polyimide substrates as a basis for wearable energy converters. Our aqueous-solution-based film fabrication process could enable readily scalable, low-cost TDs; here, we demonstrate CNT-hydroxypropyl cellulose (HPC) composite thermoelectric films by aerosol jet printing. The electrical conductivity of the composite films is controlled through the number of CNT/HPC layers printed in combination with control of the annealing conditions.

30 DIRECT ENERGY CONVERSION↗

Waste heat recovery system

A waste heat recovery system includes a Rankine cycle (RC) circuit having a pump, a boiler, an energy converter, and a condenser fluidly coupled via conduits in that order, to provide additional work. The additional work is fed to an input of a gearbox assembly including a capacity for oil by mechanically coupling to the energy converter to a gear assembly. An interface is positioned between the RC circuit and the gearbox assembly to partially restrict movement of oil present in the gear assembly into the RC circuit and partially restrict movement of working fluid present in the RC circuit into the gear assembly. An oil return line is fluidly connected to at least one of the conduits fluidly coupling the RC components to one another and is operable to return to the gear assembly oil that has moved across the interface from the gear assembly to the RC circuit.

30 DIRECT ENERGY CONVERSION↗

Data for Redefining the Product Portfolio of Oilcane Bagasse Biorefinery: Recovering Natural Colorants, Vegetative Lipids and Sugars

:Bioenergy crops have been known for their ability to produce biofuels and bioproducts. In this study, the product portfolio of recently developed transgenic sugarcane (oilcane) bagasse has been redefined for recovering natural pigments (anthocyanins), sugars, and vegetative lipids. The total anthocyanin content in oilcane bagasse has been estimated as 92.9 ± 18.9 µg/g of dried bagasse with cyanidin-3-glucoside (13.5 ± 18.9 µg per g of dried bagasse) as the most prominent anthocyanin present. More than 85 % (w/w) of the total anthocyanins were recovered from oilcane bagasse at a pretreatment temperature of 150 °C for 15 min. These conditions for the hydrothermal pretreatment also led to a 2-fold increase in the glucose yield upon the enzymatic saccharification of the pretreated bagasse. Further, a 1.5-fold enrichment of the vegetative lipids was demonstrated in the pretreated residue. Re-defining green biorefineries with multiple high-value products in a zero-waste approach is the need of the hour for attaining sustainability.

Biomass Analytics↗

Corrosion Dynamics of Carbon Steel in Small, Stagnant Volume under Radiation

The long term disposal of used nuclear fuel involves a deep geological repository (DGR) with the key barrier being the Used Fuel Container (UFC) consisting of a copper-coated carbon steel vessel. NWMO's Mark II design UFC is assembled by welding the semi-spherical head to a cylindrical body. Crevice is formed between the two parts along with the weld region. The objective of this research is to develop and validate a reliable corrosion model for long-term corrosion of CS under DGR condition. Water radiolysis produces chemically reactive species that affect corrosion rates and pathways. This work explores the synergistic effects of γ-radiation and solution properties on the dynamics of carbon steel corrosion. In Stage 1, corrosion rate is controlled by dissolution of iron to the solution phase. In Stage 2, the controlling processes are the growth of iron hydroxide gel. In Stage 3, the main iron redox reaction is the conversion between different iron oxides, and the overall corrosion rate is negligible. The concentration of Fe{sup 2+} (aq) near the metal surface reaches its solubility limit very quickly in a small, stagnant volume. Diffusion from crevice to bulk solution is more significant with larger crevice size. Porous, granular form of magnetite loosely attached to the metal surface is formed from Fe{sup 3+} in solution via reduction by H{sub 2}O{sub 2}. As a source of continuous formation of H{sub 2}O{sub 2}, radiation accelerates oxidation (Fe0 → Fe{sup 2+} → Fe{sup 3+}). Once the oxidation is almost complete, H{sub 2}O{sub 2} can act as a reducing reagent, reducing Fe{sup 3+} species back to Fe{sup 2+} forming more stable mixed Fe{sup 2+,3+} species (magnetite and maghemite)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data for Glucose Feeds the Tricarboxylic Acid Cycle via Excreted Ethanol in Fermenting Yeast

Ethanol and lactate are typical waste products of glucose fermentation. In mammals, glucose is catabolized by glycolysis into circulating lactate, which is broadly used throughout the body as a carbohydrate fuel. Individual cells can both uptake and excrete lactate, uncoupling glycolysis from glucose oxidation. Here we show that similar uncoupling occurs in budding yeast batch cultures of Saccharomyces cerevisiae and Issatchenkia orientalis . Even in fermenting S. cerevisiae that is net releasing ethanol, media 13C-ethanol rapidly enters and is oxidized to acetaldehyde and acetyl-CoA. This is evident in exogenous ethanol being a major source of both cytosolic and mitochondrial acetyl units. 2H-tracing reveals that ethanol is also a major source of both NADH and NADPH high-energy electrons, and this role is augmented under oxidative stress conditions. Thus, uncoupling of glycolysis from the oxidation of glucose-derived carbon via rapidly reversible reactions is a conserved feature of eukaryotic metabolism.

Conversion↗

Chemical-Biological Cyclic Process for Hexavalent Chromium Reduction to Trivalent Chromium in Aqueous Medium - 20224

Conventional treatment of chromium contamination focuses on immobilization of the highly toxic and water-soluble form Cr(VI), by reducing it to the relatively less toxic and less mobile trivalent form, Cr(III), using reducing compounds like ferrous sulfate or ferrous iron, Fe(II). The Cr(VI) also respond to biodegradation and subsequent reduction. During the reduction reaction, Fe(II) is oxidized to ferric, Fe(III), which, being at the highest oxidation state, has no ability to reduce Cr(VI), and therefore remediation process terminates. The good news is that metal-reducing bacteria, S. oneidensis MR-1, can regenerate Fe(II) from Fe(III) with the help of an organic electron donor in an appropriate bacterial media. Thus, in the Cr(VI) chemical remediation process, Fe(II) to Fe(III) conversion is reversed by the biological process, regenerating Fe(II) and the Cr(VI) chemical reduction process continues in a cyclic fashion. This study presents the results of regeneration of Fe(II) from fresh Fe(III) as well as from the reaction products of Cr(VI) and Fe(II). Both fresh Fe(III) and reaction product Fe(III) exhibited the same reduction behavior. Fe(II) production increased with the increase of initial concentration of Fe(III), resulting in 87.5% Fe(II) regeneration. The extent of Fe(III) reduction (Fe(II)t/Fe(III)0.hour) was 21 times higher than the extent of Cr(VI) reduction (Cr(VI)t/Cr(VI)0.hour) by S. oneidensis MR-1. In a cyclic process of sequential Cr(VI) addition, the amount of Fe(II) regeneration decreased with the increase in cycle number, a fixed quantity of starting S. oneidensis MR-1 could regenerate Fe(II) at least five times in a ten-hour period. More importantly, regenerated Fe(II) instantly reduced Cr(VI) to Cr(III). So, Fe(II) regeneration with metal-reducing bacteria has a good potential for application in groundwater and wastewater remediation in reducing Cr(VI) to Cr(III). As a comparison of chemical to biological transformation, chemical transformation of Cr(VI) by Fe(II) was almost 600 times greater than that of biological transformation. Therefore a chemical-biological cyclic process offers potential applications for remediation of groundwater and hexavalent chromium contaminated waste sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗