Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Aluminum Clad Spent Nuclear Fuel Task 4: Performance of Aluminum SNF in Dry Storage Experiment Test Plan

This document presents the activities to be performed in support of understanding the performance of aluminum spent nuclear fuel (ASNF) in dry storage. These activities will visually examine and acquire baseline samples of as-irradiated ATR fuel assembly components to determine fuel condition and the morphology of the aluminum oxyhydroxides present on the fuel external surfaces. Because the boehmite phase of oxyhydroxide is projected to be a significant contributor to radiolytic hydrogen production and general corrosion, being able to quantify its presence is of major importance to long term storage of aluminum spent nuclear fuel. Baseline samples will be taken from irradiated end adapters, removed from ATR SNF elements, stored in the ATR Canal. These will be transferred to Idaho National Laboratory (INL) Materials and Fuels Complex (MFC) to perform non-destructive and destructive testing to determine the degree of hydration of the wet-stored aluminum components prior to drying and air storage. Examination of the dry stored SNF at Idaho Nuclear Technology and Engineering Center (INTEC) in CPP-603 Irradiated Fuel Storage Facility (IFSF) will allow the opportunity to identify gross degradation and as conditions permit, sample the surface oxide on fueled and un-fueled portions of the stored assemblies. The information resulting from analysis of the ATR Canal samples will be used to support validation of surrogate samples prepared under Task 6, sample surrogate preparation, and used in Task 1, oxyhydroxide layer behavior and chemistry, Task 2, oxide layer radiolytic gas generation, and Task 5, oxide layer response to drying. Surface oxide samples collected from SNF in IFSF dry storage will SNF dry storage prediction modeling from Task 3, sealed and vented system episodic breathing and gas generation prediction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Scientific/Technical Report, Multi-Sensor Inspection and Robotic Systems for Dry Storage Casks

Once removed from service, fuel rod assemblies are cooled in a pool and then placed in dry storage until they can be transported to a repository for disposal. The extended duration that used nuclear fuel spends in dry storage makes it prudent to be able to nondestructively inspect the dry storage casks. The degradation mechanisms of most concern are chloride-induced stress corrosion cracking of the stainless steel canister that confines the spent fuel and distributed cracking of the concrete in the overpack structure. Multi-sensor inspection and robotic systems were researched, developed, built, and tested. One system operates completely outside the cask to inspect the concrete. The other system, known as the PRINSE system, for Proactive Robotic Inspection of Nuclear Storage Enclosures, enters the cask through an outlet vent and navigates around the outer surface of the stainless steel canister. The PRINSE system delivers sensors for: (i) real-time characterization of the canister surface in order to assess whether chlorides are present, (ii) detecting the presence of cracks using shear-horizontal ultrasonic guided waves, (iii) measuring the temperature of the canister surface, and (iv) a gamma radiation counter. The four sensing modalities are applicable to any cask containing a stainless steel canister, however the robotic delivery system is designed specifically for Holtec’s HI-STORM family of casks. Horizontal axis casks have exposed concrete surfaces. A fully contactless air-coupled scanning ultrasonic test platform and a frequency-wavenumber domain data analysis method are used for these concrete structures. Analysis, numerical simulation and experimental results demonstrate that distributed cracks in concrete can be detected and cracked regions localized within a scanned region of concrete. Vertical axis casks (like the HI-STORM family) have steel-clad concrete overpacks. In a separate effort, a semi-coupled test platform and a guided wave attenuation-based data analysis method are used for disbond detection. Analysis, numerical simulation and experimental results show that the bonding conditions of steel-concrete interfaces can be quantitatively characterized using the guided wave signal analysis scheme. The PRINSE system is designed for vertical axis dry storage casks, specifically the HI-STORM family. The double pulse laser-induced breakdown spectroscopy (LIBS) system takes advantage of an optical fiber to deliver intense light to the canister surface that enables surface composition characterization in-situ in real time. Chlorine concentrations as low as 10 mg/m2 were detected on stainless steel. Additionally, a simpler laser setup was created to detect sodium as a surrogate for chlorine, and sodium was detectable when the chlorine concentration was as low as 0.5 mg/m2. The electromagnetic acoustic transducers (EMATs) enable detection of stress corrosion cracks. The EMATs generate shear-horizontal waves that propagate around the canister and are reflected by cracks enabling 100% of the canister weld lines to be inspected. The EMAT-based crack detection system was tested at the Pacific Northwest National Laboratory on a canister containing blind defects and was shown to detect the crack sizes it was designed to detect. The PRINSE system is a novel marsupial robot. The command center and winch outside the cask control the delivery arm and train of cars that traverse the outside of the canister from the cask ventilation system. The sensors are housed in the cargo bays of three cars that comprise the train, which is lowered to the bottom of the canister by the winch. Encoders on the winch enable the sensors to be delivered to a prescribed location, e.g., for re-inspection of a problem area. The PRINSE system does not mar the canister surface, can be extracted manually in the case of a power failure, and is designed for an elevated temperature and gamma radiation environment, although not all components of the prototype are made from the final materials. The PRINSE system was tested on a full canister that was placed inside a HI-STORM cask at the Holtec Manufacturing Division. It was also demonstrated on a full-height mockup at Penn State to a live audience.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Zr Recycle Installation of Out-of-Cell Accessory Facilities

Design, fabrication, and installation of the out-of-cell accessory equipment for the Zr Recycle Project tests with actual used nuclear fuel (UNF) cladding was completed on September 9, 2016, shortly before installation of the hot cell equipment. As indicated in Figures 1 and 2, the out -of- cell equipment includes (1) a gas cabinet for a chlorine cylinder, (2) piping and valves, (3) flow control valves, and (4) two shielded plugs in the hot cell walls, one for gas flow piping from the Charging Area and one for electric power and thermocouple instrumentation from the Operating Area. In addition, wiring for flow control signals and piping for Argon gas transfer were run through the existing pass-through tube underneath the hot cell to enable operation of flow controller signals in the Operating Area to the control valves and piping located in the Charging Area. The shielded plug from the Charging Area into the hot cell contains spare lines that can be used in the future for transferring off-gas from the test equipment to tritium traps located in the Charging Area, and then back into the hot cell for caustic scrubbing and venting.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of Oxyhydroxides on a Dry-Stored Fuel Plate From L-Basin

This report describes the characterization of oxyhydroxide (oxide) films on a fuel plate that was previously irradiated in an RU-1 pool type reactor in Uruguay and subsequently stored in vented dry storage, first in Uruguay and most recently in L-Area on the Savannah River Site. Characterization of the as-received oxides includes the oxide morphology, thickness, structure, and chemical composition. The results from this work will, in a future report, be compared to characterizations of oxide films grown on alloys in the laboratory under prototypic conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NM Tech Mercury Spill Response

A mercury-based sphygmomanometer was used in the New Mexico Tech Medical clinic because a patient had consistently high blood pressure measurements when a mercury-free sphygmomanometer was used. The mercury-based unit was chosen to verify the mercury-free measurements. When the nurse began pumping up the cuff, mercury leaked from the bottom of the machine. Prior to that use, the sphygmomanometer functioned correctly, and inspection showed no visible cracks. Knowing that mercury (Hg) was hazardous to patients, that it vaporized at room temperature, and that the clinic had no windows, the nurse moved the sphygmomanometer from the clinic to a nearby biohazard room. In addition, the nurse taped the door gaps on the outside of the biohazard room to limit exposure. The biohazard room was vented to the outside, but that fact was not commonly known by the incident response team. The floor between the clinic and biohazard room was carpeted, resulting in Hg contamination of the carpet as well as the clinic and the biohazard room.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon Dioxide Storage and Utilization near Mingo County, West Virginia

Six oil fields within 100 miles of the planned coal-to-liquids facility in Mingo County were found to be prospective for miscible CO 2 -EOR. Four of the oil fields fall along a straight line and could, in concept, be developed sequentially along a single CO 2 pipeline. The total demand for purchased CO 2 from these four fields is estimated to be 47 million metric tons (890 Bcf) over 20 years. Four saline formations within Mingo County could accommodate 50 million metric tons of CO 2 (accounts for uncertainty and a &'buffer zone”). The combined storage capacity – EOR within 100 miles of Mingo County and saline within Mingo County – can accommodate 3 million metric tons per year of vented CO 2 for over 30 years Conclusion: there is enough potential for CO 2 utilization and storage that a next level of study is a reasonable course.

03 NATURAL GAS↗

Natural Gas Well Workovers

This unit process quantifies the mass of vented gas that is anticipated to result from natural gas well workovers, associated with the production of natural gas from conventional and unconventional wells. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=AA9DDEBE-EEDD-4102-9B57-7FB86849EAAD

03 NATURAL GAS↗

Crude Production Associated Gas Emissions Composition

Speciated vented and fugitive losses of unit process specific associated gas. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=8E810FCD-3326-4A19-BF5F-90C64CEC923C

02 PETROLEUM↗

Sealed and Insulated Attic Hygrothermal Performance in New California Homes Using Vapor and Air Permeable Insulation—Field Study and Simulation

This project investigated the thermal and moisture performance of a low-cost approach to sealing and insulating attics using glass fiber insulation. The work included a combination of: (1) field measurements of attic and HVAC system performance in two new, high-performance homes in California’s Central Valley (Fresno), and (2) hygrothermal simulations of attic performance. Each field study attic was continuously monitored at multiple locations for over a year for wood moisture content, air humidity, condensation, temperature, and heat flux, together with on-site weather and solar conditions. The Fresno test home showed periodic condensation and high surface wood moisture content, but no surface mold or degradation upon visual inspection at the end of the test period. The Clovis test home showed less indication of high moisture levels—either from surface condensation or wood moisture content—but did have visible suspected mold growth on the inside of the North sheathing at the end of the field testing. These results show the limitations of current moisture measurement techniques focused on wood moisture content, rather than potential for mold growth. From a thermal/energy perspective the attics were close to indoor conditions thereby realizing the design intent for reducing duct system losses. Simulated site HVAC energy savings for sealed vs. vented attics averaged 18% across California climate regions (8% TDV energy savings). Savings were dominated by heating energy reductions; cooling savings were substantially lower. The moisture issues are investigated in greater detail in the simulations. First, we identified the climate regions and house characteristics that are associated with increased risk of mold growth or wood rot in new CA homes. Climate region was very important in determining risk, as were house features that reduced outside air exchange (e.g., 1-story homes, very tight envelopes, very tight attics, no IAQ fan), along with those that increased flow of moist air from the living space to the attic (e.g., supply ventilation fans, larger ceiling leaks, duct leakage). Second, we investigated several approaches to reduce moisture risks, and the best approach was to use a vapor retarder on the inner face of the fiberglass insulation. Both the field and simulation results indicate that the use of air and vapor permeable insulation can be acceptable from a thermal/energy point of view, but additional measures need to be taken to reduce moisture risks, primarily from mold growth.

42 ENGINEERING↗

Life Cycle Analysis of Natural Gas Extraction and Power Generation

This analysis expands upon previous life cycle analyses (LCAs) of natural gas systems performed by the National Energy Technology Laboratory (NETL). It provides a complete inventory of emissions to air and water, water consumption, and land use change. These environmental burdens are detailed for all supply chain steps from natural gas production through natural gas distribution. This analysis has 30 distinct scenarios. The scenarios include 14 onshore production basins with their respective extraction technologies, for a total of 27 onshore scenarios. The scenarios also include two offshore production scenarios, Gulf of Mexico (GoM) and offshore Alaska, and an associated gas scenario. The results include a national average based on a production-weighted aggregation of the onshore, offshore, and associated gas scenarios. The life cycle GHG emissions from the United States (U.S.) natural gas supply chain are 19.9 g carbon dioxide equivalents (CO2e)/MJ (with a 95% mean confidence interval of 13.1 to 28.7 g CO2e/MJ). The top contributors to carbon dioxide (CO2) and methane (CH4) emissions are combustion exhaust and other venting from compressor systems. Compressor systems are prevalent in most supply chain stages, so compressor emissions are key emission drivers for life cycle emissions. Emission rates are highly variable across the entire supply chain. The national average CH4 emission rate is 1.24%, with a 95% confidence interval ranging from 0.84% to 1.76%.

Littlefield, James↗

Retrofit of Blown Attic Insulation in Existing HUD-Code Manufactured Homes: Needs Assessment Report

This needs assessment was conducted by the Washington State University (WSU) Energy Program and Building Science Corporation (BSC), with support from the U.S. Department of Energy's (DOE) Building Technologies Office. The primary goal of this research was to identify moisture durability, energy savings, and savings-to-investment ratio (SIR) research needs related to the retrofit of attic insulation in the DOE Weatherization Assistance Program (WAP). Specifically, manufactured homes that comply with building codes established by the U.S. Department of Housing and Urban Development (HUD) built after 1976 and sited in colder climates. This project assessed current practice of WAP insulation and/or roof venting solutions that improve attic insulation energy savings and durability. WSU and BSC conducted outreach to stakeholders via email, phone, one-on-one interviews, and group meetings designed to inquire about relevant issues that they may have observed. Needs assessment feedback was provided from stakeholders involved with attic insulation retrofits in existing HUD-code manufactured housing in the colder climates of the United States. The list of more than 50 stakeholders who provided input into this needs assessment is provided in Appendix A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Processing centrifugal compression

Processing compression, including fuel used by centrifugal compressor drivers and venting from centrifugal compressors. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=60FF9CAA-D660-4BAD-ADCA-F91A33570336

42 ENGINEERING↗

Processing reciprocating compression

Processing compression, including fuel used by reciprocating compressor drivers and venting from reciprocating compressors. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=3D5AEE88-0235-40B8-8FB0-8896C066505E

42 ENGINEERING↗

Storage centrifugal compression

Storage compression, including fuel used by centrifugal compressor drivers and venting from centrifugal compressors. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=CB0C2D47-75B2-4162-982E-07121ACFF50D

42 ENGINEERING↗

Storage reciprocating compression

Storage compression, including fuel used by reciprocating compressor drivers and venting from reciprocating compressors. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=AB364FE0-DEC5-4AB4-B9A4-057E6EB0F540

42 ENGINEERING↗

Transmission centrifugal compression

Transmission compression, including fuel used by centrifugal compressor drivers and venting from centrifugal compressors. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=635F7F54-7B38-4040-A2D4-F83C5D86B406

42 ENGINEERING↗

Transmission reciprocating compression

Transmission compression, including fuel used by reciprocating compressor drivers and venting from reciprocating compressors. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=BB3031A7-849A-4CF5-A84D-089CA5AD693B

42 ENGINEERING↗

Retrofit of Blown Attic Insulation in Existing HUD-Code Manufactured Homes: Needs Assessment Report

This needs assessment was conducted by the Washington State University (WSU) Energy Program and Building Science Corporation (BSC), with support from the U.S. Department of Energy's (DOE) Building Technologies Office. The primary goal of this research was to identify moisture durability, energy savings, and savings-to-investment ratio (SIR) research needs related to the retrofit of attic insulation in the DOE Weatherization Assistance Program (WAP). Specifically, manufactured homes that comply with building codes established by the U.S. Department of Housing and Urban Development (HUD) built after 1976 and sited in colder climates. This project assessed current practice of WAP insulation and/or roof venting solutions that improve attic insulation energy savings and durability. WSU and BSC conducted outreach to stakeholders via email, phone, one-on-one interviews, and group meetings designed to inquire about relevant issues that they may have observed. Needs assessment feedback was provided from stakeholders involved with attic insulation retrofits in existing HUD-code manufactured housing in the colder climates of the United States. The list of more than 50 stakeholders who provided input into this needs assessment is provided in Appendix A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗