Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Technetium Removal Using Tc-Goethite Coprecipitation

This report describes the results from laboratory tests performed at Pacific Northwest National Laboratory for the U.S. Department of Energy (DOE) EM-31 Support Program (EMSP) subtask, “Low temperature waste forms coupled with technetium removal using an alternative immobilization process such as Fe(II) treated-goethite precipitation” to increase our understanding of 99Tc long-term stability in goethite mineral form and the process that controls the 99Tc(VII) reduction and removal by the final Fe (oxy)hydroxide forms. The overall objectives of this task were to 1) evaluate the transformation process of Fe (oxy)hydroxide solids to the more crystalline goethite (α-FeOOH) mineral for 99 Tc removal and 2) determine the mechanism that limits 99 Tc(IV) reoxidation in Fe(II)-treated 99 Tc-goethite mineral and 3) evaluate whether there is a long-term 99 Tcoxidation state change for Tc sequestered in the iron solids.

Goethite↗

Measure Guideline: Combustion Safety for Natural Draft Appliances Using Indoor Air

This Measure Guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate Measure Guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combustion Safety for Appliances Using Indoor Air (Fact Sheet)

This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mo-99 Stripping Results and Column Designs for Mini-Medical Isotope Production System (MIPS)

Results from the column tests performed by using small volumes of irradiated solutions as tracers for depleted uranium (DU) solutions containing stable molybdenum (Mo) as Na 2 MoO 4 forced us to investigate the stripping parameters needed to obtain full Mo recovery. In an effort to optimize the stripping conditions, several column runs were done by using either 1 M NaOH or NH 4 OH as the stripping agent at different velocities. Overall, we obtained very inconsistent results that suggest stripping velocity does not affect Mo recovery as much as originally believed. In addition, we generated 0.1 M HNO 3 breakthrough curves after each run to determine if the performance of the column was changing. Future experiments will utilize columns packed with fresh sorbent after each run. The column designs for the mini-MIPS 5-liter (L) and 20-L experiments employed data obtained from using several different S80 columns at different loading, washing, and stripping velocities. Data were input into the VERSE code, and plant-scale column designs were generated. The mini-MIPS column designs and parameters are a direct downscale of the plant operation, where full Mo adsorption and recovery are expected.

Youker, Amanda J.↗

An Investigation of the Applicability and Limitations of the ORNL Expanded Plug Test

The expanded plug test technique for measuring the circumferential tensile properties of irradiated nuclear fuel cladding was developed at Oak Ridge National Laboratory (ORNL) and has been used successfully in several applications. The primary advantage of this technique over other procedures is its simplicity for application in the complex hot cell environment. During the development stage, efforts were made to both qualify the technique as much as possible regarding its experimental application and to develop and validate the data reduction procedures. However, since this is a new technique, the technical community is cautious in adopting a procedure that has not been fully vetted. The purpose of this effort was to address several baseline issues regarding the applicability of the technique and the precision of the use of experimental expanded ring load-deformation data to calculate material circumferential stress-strain properties. The tests performed, in conjunction with the developed data reduction procedures, demonstrate good reliability in the prediction of ring material stress-strain behavior for several materials of widely different strengths.

tensile, nuclear fuel cladding↗

LAMMPS strong scaling performance optimization on Blue Gene/Q

LAMMPS "Large-scale Atomic/Molecular Massively Parallel Simulator" is an open-source molecular dynamics package from Sandia National Laboratories. Significant performance improvements in strong-scaling and time-to-solution for this application on IBM's Blue Gene/Q have been achieved through computational optimizations of the OpenMP versions of the short-range Lennard-Jones term of the CHARMM force field and the long-range Coulombic interaction implemented with the PPPM (particle-particle-particle mesh) algorithm, enhanced by runtime parameter settings controlling thread utilization. Additionally, MPI communication performance improvements were made to the PPPM calculation by re-engineering the parallel 3D FFT to use MPICH collectives instead of point-to-point. Performance testing was done using an 8.4-million atom simulation scaling up to 16 racks on the Mira system at Argonne Leadership Computing Facility (ALCF). Speedups resulting from this effort were in some cases over 2x.

Coffman, Paul↗

Investigation of HNO2 Production in Solvent Extraction Organic Phases

This document is a letter report that was prepared to meet FCR&D level 4 milestone M4FT-14IN0304054, “Investigate HNO2 production in solvent extraction organic phases.” This work was carried out under the auspices of the Fundamental Radiation Chemistry FCR&D work package. This document reports on an initial tests performed to follow HNO2 formation in reference flowsheet relevant organic phases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design & Implementation of MACSio

We are proposing to develop “MACSio” (pronounced “max-ee-oh”), a Multi-purpose, Application-Centric, Scalable I/O proxy application. It is being proposed to fill a long existing void in co-design proxy applications that allow for I/O performance testing and evaluation of tradeoffs in data model interfaces and parallel I/O paradigms for multi-physics, HPC applications. Two key design features of MACSio will set it apart from existing I/O benchmarking tools. The first is the level of abstraction (LOA) at which MACSio is being designed to operate. The second is the degree of flexibility MACSio is being designed to provide in driving an HPC I/O workload through parameterized, user-defined data objects and a variety of parallel I/O paradigms and I/O interfaces. Combined, these features will allow MACSio to closely mimic I/O workloads for a wide variety of real applications and, in particular, multi-physics applications where data object distribution and composition vary dramatically both within and across parallel tasks. These data objects can then be marshaled using one or more I/O interfaces and parallel I/O paradigms, allowing for direct comparisons of software interfaces, parallel I/O paradigms, and filesystem technologies with the same set of customizable data objects.

97 MATHEMATICS AND COMPUTING↗

Causal Analysis For Occurrence Report: OR NA-SS-SNL-2000-2015-0005 Unexpected Type of Failure of Thermal Battery

On 6/26/2015 at approximately 1445 in 894/136, a pulse thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following an electrical performance test that is routinely conducted on thermal batteries. A dedicated tester for this operation was used and it ran the test until the nominal 28-volt output of the battery had dropped to 5 volts, usually indicative of the battery being spent and safe enough to move. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another primary containment box within the same room; initial indications are that the battery experienced an over-pressurization failure which led to the battery's base plate being expelled and the operator receiving a non-recordable injury (bruising to the palm of the hand) from the pressure of the expulsion. The operator was wearing the prescribed PPE (safety glasses and high temperature glove) and was handling the battery appropriately with an open, flat hand. Pictures of the scene are below.

25 ENERGY STORAGE↗

GrayQb TM Single-Faced Version 2 (SF2) Open Environment Test Report (Rev. 1)

This report details the design upgrades incorporated into the new version of the GrayQb TM SF2 device and the characterization testing of this upgraded device. Results from controlled characterization testing in the Savannah River National Laboratory (SRNL) R&D Engineering Imaging and Radiation Lab (IRL) and the Savannah River Site (SRS) Health Physics Instrument Calibration Laboratory (HPICL) is presented, as well as results from the open environment field testing performed in the E-Area Low Level Waste Storage Area. Resultant images presented in this report were generated using the SRNL developed Radiation Analyzer (RAzer TM ) software program which overlays the radiation contour images onto the visual image of the location being surveyed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commercial Building Motor Protection Response Report

When voltages recover, motors may immediately reenergize and reaccelerate, or delay for a few minutes, or stay stalled. The estimated motor response is given for both the voltage sag magnitude and voltage sag duration. These response estimates are based on experience and available test data. Good data is available for voltage sag response for many components such as relays and contactors, but little data is available for both voltage sag and recovery response. The tables in Appendix A include data from recent voltage sag and recovery tests performed by SCE and BPA on air conditioners and energy management systems. The response of the motor can vary greatly depending on the type of protection and control. The time duration for the voltage sag consists of those times that are of interest for bulk power system modelers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CALiPER Application Summary Report 15: LED Floodlights

This report analyzes the independently tested performance of 10 LED floodlights purchased between August and December 2011. The group included a wide range of products, both physically and in performance characteristics, which mirrors the nearly indefinite range of conventional luminaires designated as floodlights.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Combustion Safety for Natural Draft Appliances Using Indoor Air

This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and construction of coal/biomass to liquids (CBTL) process development unit (PDU) at the University of Kentucky Center for Applied Energy Research (CAER)

This report describes a first phase of a project to design, construct and commission an integrated coal/biomass-to-liquids facility at a capacity of 1 bbl. /day at the University of Kentucky Center for Applied Energy Research (UK-CAER) – specifically for construction of the building and upstream process units for feed handling, gasification, and gas cleaning, conditioning and compression. The deliverables from the operation of this pilot plant [when fully equipped with the downstream process units] will be firstly the liquid FT products and finished fuels which are of interest to UK-CAER’s academic, government and industrial research partners. The facility will produce research quantities of FT liquids and finished fuels for subsequent Fuel Quality Testing, Performance and Acceptability. Moreover, the facility is expected to be employed for a range of research and investigations related to: Feed Preparation, Characteristics and Quality; Coal and Biomass Gasification; Gas Clean-up/ Conditioning; Gas Conversion by FT Synthesis; Product Work-up and Refining; Systems Analysis and Integration; and Scale-up and Demonstration. Environmental Considerations - particularly how to manage and reduce carbon dioxide emissions from CBTL facilities and from use of the fuels - will be a primary research objectives. Such a facility has required significant lead time for environmental review, architectural/building construction, and EPC services. UK, with DOE support, has advanced the facility in several important ways. These include: a formal EA/FONSI, and permits and approvals; construction of a building; selection of a range of technologies and vendors; and completion of the upstream process units. The results of this project are the FEED and detailed engineering studies, the alternate configurations and the as-built plant - its equipment and capabilities for future research and demonstration and its adaptability for re-purposing to meet other needs. These are described in some detail in this report, along with lessons learned.

01 COAL, LIGNITE, AND PEAT↗

Brookfield Homes Passive House Performance Evaluation

In 2012-2013, IBACOS worked with a builder, Brookfield Homes in Denver, Colorado, to design and construct a Passive House certified model home. IBACOS used several modeling programs and calculation methods to complete the final design package along with Brookfield's architect KGA Studio. This design package included upgrades to the thermal enclosure, basement insulation, windows, and heating, ventilation, and air conditioning. Short-term performance testing in the Passive House was done during construction and after construction. Testing with a blower door indicated that whole-building air leakage to the outside was 324 CFM and 0.60 ACH50. The other two test homes had little short-term testing done post-construction by the local energy rater. IBACOS then monitored the energy consumption and whole-house comfort conditions of that occupied Passive House after one year of operation and compared the monitoring results to those for two other occupied test houses in the same area with similar square footage but slightly different floor plans. IBACOS also assisted the builder, Brookfield Homes, in researching design scenarios for Zero Energy Ready Home and ENERGY STAR acceptance levels. IBACOS also assisted Brookfield in conceptualizing product for Denver's Brighton Heights area. Brookfield was considering building to Zero Energy Ready Home standards in that location. IBACOS provided strategies that Brookfield may draw from in the event the builder chooses to pursue a Zero Energy Ready Home plan for that market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗