Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Technology Deployment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

CHEMICAL STABILITY OF POLYPHENYLENE SULFIDE IN THE NEXT GENERATION SOLVENT FOR CAUSTIC-SIDE SOLVENT EXTRACTION

The Office of Waste Processing, within the Office of Technology Innovation and Development, is funding the development of an enhanced solvent for deployment at the Savannah River Site for removal of cesium from High Level Waste. For simplicity, this solvent is referred to as the Next Generation Solvent (NGS). The technical effort is collaboration between Oak Ridge National Laboratory (ORNL), Savannah River National Laboratory (SRNL), and Argonne National Laboratory. The initial deployment target envisioned for the technology was within the Modular Caustic-Side Solvent Extraction Unit (MCU). Deployment of a new chemical within an existing facility requires verification that the chemical components are compatible with the installed equipment. In the instance of a new organic solvent, the primary focus is on compatibility of the solvent with polyphenylene sulfide (PPS), the polymer used in the coalescers within MCU. This report provides the data from exposing PPS polymer to NGS. The test was conducted over a three month period. PPS is remarkably stable in the presence of the next generation solvent. Testing showed no indication of swelling or significant leaching. Preferential sorption of the Modifier on PPS was observed but the same behavior occurs with the baseline solvent. Therefore, PPS coalescers exposed to the NGS are expected to perform comparably to those in contact with the baseline solvent.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bioenergy Technologies Office 2019 R&D State of Technology

The U.S. Department of Energy’s Bioenergy Technologies Office funds research and development on technologies necessary for the deployment and production of cost-competitive bioenergy, primarily biofuels. Results of experimental efforts are periodically compiled and compared with benchmark technology designs to assess overall progress. This report provides a status of those R&D efforts at the end of 2019. This report first describes the approach for assessing progress followed by specific technology pathway configurations within which progress is charted. Each pathway configuration is described separately and the state of technology progress is presented for the combined pathway as well as for pathway components. Detailed component descriptions reference technology barriers and challenges that are detailed in the appendix.

09 BIOMASS FUELS↗

United States–Brazil Joint Study: A Preliminary Assessment of Opportunities and Challenges for Small Modular Reactors in Brazil

This report supplies the technical information to enable a broader understanding of different technology choices for nuclear reactors in Brazil. The assessment characteristics of this process include reactor technology, economic costs for deployment, and regulatory analyses of small modular reactors, advanced reactors, and microreactors. The analysis documented in this report provides economic and technological information to assist Brazil, whose official indicative scenarios show an increase in operating nuclear power from 2 Gigawatt in 2022 to 8–10 Gigawatt by 2050, in policy making and long-term energy planning. To protect company proprietary information, the information in this report was limited to publicly available information and therefore can only inform preliminary reactor technology assessments. This report does not recommend or endorse any specific reactor developer or technology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Clean Energy Technologies for Economic and Environmental Transitions

Energy systems across the world are undergoing fundamental transformations. Electricity and heat production are becoming cleaner and more distributed, driven by declining energy prices and higher technology efficiencies, as well as a desire to reduce environmental impact. The technologies that produce clean energy, such as solar photovoltaic panels, wind turbines, and lithium ion batteries for vehicles and storage, depend less on fuel costs and more on technology costs and global manufacturing and trade. Therefore, innovations in technology manufacturing, systems integration, and deployment can reduce costs of materials, equipment, labor, operations, and transportation, across all the links in the energy supply chain. The clean energy trends are expected to continue and perhaps grow through expansion of clean energy technologies for industrial and transportation sectors, although there are many possible future scenarios due to the diversity of resources and societal objectives in different communities, countries, and regions. This presentation will summarize the status and potential futures of key clean energy technologies and their manufacturing, deployment, and integration with other energy systems and sectors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Deployable platform systems development

The long range objective is to achieve technology readiness for one or more deployable platform systems by 1986. Engineering plans and approaches to meet this goal are presented in outline form.

Jewell, R. E.↗

Additive Manufacturing in the Nuclear Reactor Industry

This article discusses the application of additive manufacturing in the nuclear reactor industry.Additive manufacturing for nuclear applications increased significantly in the late 2010s due to rapid progress in technology, particularly with methods using metals and ceramics.Because these manufacturing technologies are uniquely data-rich, they allow for an advanced understanding of materials, and they offer the potential to predict part performance based on build data. The inherent characteristics of additive manufacturing technologies allow for rapid prototyping and geometric freedom, making it possible to implement an accelerated agile design process for advanced nuclear reactor applications. Predictive high-fidelity multiphysics simulations are crucial to fully leverage this geometric flexibility. Qualification and regulator acceptance ultimately determine the breadth and scope of applications for these technologies. The US Department of Energy Office of Nuclear Energy Transformational Challenge Reactor program integrates many of these elements to accelerate the deployment of additive manufacturing technologies to industry.

Betzler, Benjamin↗

Optimal energy storage portfolio for high and ultrahigh carbon-free and renewable power systems

Achieving 100% carbon-free or renewable power systems can be facilitated by the deployment of energy storage technologies at all timescales, including short-duration, long-duration, and seasonal scales; however, most current literature focuses on cost assessments of energy storage for a given timescale or type of technology. In this work, we use an optimization framework with high spatial and temporal resolution to simultaneously assess the variable renewable power deployment and the optimal storage portfolio for seven independent system operators in the United States. Results indicate that achieving high (75–90%) and ultrahigh (>90%) energy mixes requires combining several flexibility options, including renewable curtailment, short-duration, long-duration, and seasonal storage. For instance, carbon-free and renewable energy mix targets of up to 80% are achieved with economic curtailment and a combination of short- and long-duration energy storage for the performance and cost assumptions used. After that, there is a point between 80% and 95% where seasonal storage becomes cost-competitive, depending on the specific power system. Moreover, our results indicate that storage-to-storage operation—one storage device used to charge another storage device—and the decoupling of charging and discharging storage power capacity are cost-effective options for the integration of high and ultrahigh shares of carbon-free or renewable power sources. Additionally, the results from this study show that an 85% carbon-free or renewable energy mix can be achieved at a cost of avoided CO 2 emissions of US$66.0 per tonne or less, regardless of the power system.

25 ENERGY STORAGE↗

Biomass Scenario Model: BETO Analysis Platform Peer Review; NREL (National Renewable Energy Laboratory)

The Biomass Scenario Model (BSM) is a unique, carefully validated, state-of-the-art fourth-generation model of the domestic bioenergy supply chain which explicitly focuses on policy issues and their potential side effects. It integrates resource availability, behavior, policy, and physical, technological, and economic constraints. The BSM uses system-dynamics simulation to model dynamic interactions across the supply chain; it tracks the deployment of biofuels given technological development and the reaction of the investment community to those technologies in the context of land availability, the competing oil market, consumer demand for biofuels, and government policies over time. It places a strong emphasis on the behavior and decision-making of various economic agents. The model treats the major infrastructure-compatible fuels. Scenario analysis based on the BSM shows that the biofuels industry tends not to rapidly thrive without significant external actions in the early years of its evolution. An initial focus for jumpstarting the industry typically has strongest results in the BSM in areas where effects of intervention have been identified to be multiplicative. In general, we find that policies which are coordinated across the whole supply chain have significant impact in fostering the growth of the biofuels industry and that the production of tens of billions of gallons of biofuels may occur under sufficiently favorable conditions.

09 BIOMASS FUELS↗

Methods for heel retrieval for tanks C-101, C-102, and C-111 at the Hanford Site

The purpose of this paper is to evaluate the prospects of using bulk waste characteristics to determine the most appropriate heel retrieval technology. If the properties of hard to remove heels can be determined before bulk retrieval, then a heel retrieval technology can be selected before bulk retrieval is complete. This would save substantially on sampling costs and would allow the deployment of the heel retrieval technology immediately after bulk retrieval. The latter would also accelerate the heel removal schedule. A number of C-farm retrievals have been fully or partially completed at the time of this writing. Thus, there is already substantial information on the success of different technologies and the composition of the heels. There is also substantial information on the waste types in each tank based on historical records. Therefore, this study will correlate the performance of technologies used so far and compare them to the known waste types in the tanks. This will be used to estimate the performance of future C Farm heel retrievals. An initial decision tree is developed and employed on tanks C-101, C-102, and C 111. An assumption of this study is that no additional characterization information would be available, before or after retrieval. Note that collecting additional information would substantially increase the probability of success. Deploying some in-situ testing technologies, such as a water lance or an in-situ Raman probe, might substantially increase the probability of successfully selecting the process conditions without having to take samples from the tanks for laboratory analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods for Heel Retrieval for Tanks C-101, C-102, and C-111 at the Hanford Site - 13064

The purpose of this paper is to evaluate the prospects of using bulk waste characteristics to determine the most appropriate heel retrieval technology. If the properties of hard to remove heels can be determined before bulk retrieval, then a heel retrieval technology can be selected before bulk retrieval is complete. This would save substantially on sampling costs and would allow the deployment of the heel retrieval technology immediately after bulk retrieval. The latter would also accelerate the heel removal schedule. A number of C-farm retrievals have been fully or partially completed at the time of this writing. Thus, there is already substantial information on the success of different technologies and the composition of the heels. There is also substantial information on the waste types in each tank based on historical records. Therefore, this study will correlate the performance of technologies used so far and compare them to the known waste types in the tanks. This will be used to estimate the performance of future C Farm heel retrievals. An initial decision tree is developed and employed on tanks C-101, C-102, and C 111. An assumption of this study is that no additional characterization information would be available, before or after retrieval. Note that collecting additional information would substantially increase the probability of success. Deploying some in-situ testing technologies, such as a water lance or an in-situ Raman probe, might substantially increase the probability of successfully selecting the process conditions without having to take samples from the tanks for laboratory analysis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Value of Wind Technology Innovation: Implications for the U.S. Power System, Wind Industry, Electricity Consumers, and Environment

Improvements to wind technologies have, in part, led to substantial deployment of U.S. wind power in recent years. The degree to which technology innovation will continue is highly uncertain adding to uncertainties in future wind deployment. We apply electric sector modeling to estimate the potential wind deployment opportunities across a range of technology advancement projections. The suite of projections considered span a wide range of possible cost and technology innovation trajectories, including those from a recent expert elicitation of wind energy experts, a projection based on the broader literature, and one reflecting estimates based on a U.S. DOE research initiative. In addition, we explore how these deployment pathways may impact the electricity system, electricity consumers, the environment, and the wind-related workforce. Overall, our analysis finds that wind technology innovation can have consequential implications for future wind power development throughout the United States, impact the broader electricity system, lower electric system and consumer costs, provide potential environmental benefits, and grow the U.S. wind workforce.

17 WIND ENERGY↗

Distribution Power Flow for Smart Grid Technologies

Smart Grid technologies hold the promise of being able to solve many of the problems currently facing in the electric power industry. However, the large scale deployment of these new technologies has been limited due to an inability to accurately model their effects or to quantify their potential benefits. GridLAB-D is a new open source power system modeling and simulation environment developed by the United States Department of Energy specifically to integrate detailed power systems and end-use models. In order to effectively model the vast array of possible smart grid technologies GridLAB-D was developed as a general simulation environment. This paper describes the basic design concept, the power flow solutions implemented, and a detailed example of the type of analysis that can be performed within the simulation environment in order to support the evaluation of smart grid technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Case Study for the ARRA-funded GSHP Demonstration at University at Albany

High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects—a distributed GSHP system at a new 500-bed apartment-style student residence hall at the University at Albany. This case study is based on the analysis of detailed design documents, measured performance data, published catalog data of heat pump equipment, and actual construction costs. Simulations with a calibrated computer model are performed for both the demonstrated GSHP system and a baseline heating, ventilation, and air-conditioning (HVAC) system to determine the energy savings and other related benefits achieved by the GSHP system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GSHP system, as well as the pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the demonstrated GSHP system compared with the baseline HVAC system. This case study also identifies opportunities for improving the operational efficiency of the demonstrated GSHP system.

15 GEOTHERMAL ENERGY↗

Case Study for ARRA-funded Ground-Source Heat Pump (GSHP) Demonstration at Oakland University

High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a ground-source variable refrigerant flow (GS-VRF) system installed at the Human Health Building at Oakland University in Rochester, Michigan. This case study is based on the analysis of measured performance data, maintenance records, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning as the demonstrated GS-VRF system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GS-VRF system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GS-VRF system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation, improving the operational efficiency, and reducing the installed cost of similar GSHP systems in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study for the ARRA-funded Ground Source Heat Pump Demonstration at Denver Museum of Nature & Science

High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects were competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one such GSHP demonstration projects that uses a recycled water heat pump (RWHP) system installed at the Denver Museum of Nature & Science in Denver, Colorado. The RWHP system uses recycled water from the city’s water system as the heat sink and source for a modular water-to-water heat pump (WWHP). This case study was conducted based on the available measured performance data from December 2014 through August 2015, utility bills of the building in 2014 and 2015, construction drawings, maintenance records, personal communications, and construction costs. The annual energy consumption of the RWHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional VAV system using a water-cooled chiller and a natural gas fired boiler, both of which have the minimum energy efficiencies allowed by ASHRAE 90.1-2010. The comparison was made to determine energy savings, operating cost savings, and CO2 emission reductions achieved by the RWHP system. A cost analysis was performed to evaluate the simple payback of the RWHP system. Summarized below are the results of the performance analysis, the learned lessons, and recommended improvement in the operation of the RWHP system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study for the ARRA-funded Ground Source Heat Pump (GSHP) Demonstration at Wilders Grove Solid Waste Service Center in Raleigh, NC

High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a distributed GSHP system for providing all the space conditioning, outdoor air ventilation, and 100% domestic hot water to the Wilders Grove Solid Waste Service Center of City of Raleigh, North Carolina. This case study is based on the analysis of measured performance data, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning and outdoor air ventilation as the demonstrated GSHP system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GSHP system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation and improving the operational efficiency of the demonstrated GSHP system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Impacts of Terminal Restrictions on Departures in D10 TRACON

The D10 – Dallas-Fort Worth Terminal Radar Approach CONtrol (TRACON) is an air traffic facility that controls and manages aircraft and airspace that consists of multiple airports located in the North Texas area. From an air traffic management standpoint, one of the main challenges in the D10 TRACON is the departure fix capacity as multiple airports compete for resources. This problem is magnified when en route demand/capacity imbalance and inclement weather around the TRACON reduce the capacity at the terminal fixes. This leads to multiple, dynamic Traffic Management Initiative (TMI) restrictions being issued by the Air Traffic Control (ATC) on departing flights. This, in turn, propagates delay to the surface of each airport within the metroplex. The NASA Airspace Technology Demonstration 2 (ATD-2) Phase 3 is deployed in D10 to demonstrate new technologies developed to manage the Integrated Arrival, Departure, and Surface (IADS) traffic in a metroplex environment where multiple airports are interacting and sharing resources at the terminal boundary. This paper uses the ATD-2 terminal restriction data collected in the D10 TRACON to quantify the impact of restrictions on the demand, analyze the relation between terminal restrictions and departure taxi time on airport surface, and establish relationships between restrictions and surface delay. We found that the restrictions on departure flights have a direct adverse effect on departure excess taxi time on the airport surface.

ATD-2↗

Analysis of Impacts of Terminal Restrictions on Departures in D10 TRACON

The D10 – Dallas-Fort Worth Terminal Radar Approach CONtrol (TRACON) is an air traffic facility that controls and manages aircraft and airspace that consists of multiple airports located in the North Texas area. From an air traffic management standpoint, one of the main challenges in the D10 TRACON is the departure fix capacity as multiple airports compete for resources. This problem is magnified when en route demand/capacity imbalance and inclement weather around the TRACON reduce the capacity at the terminal fixes. This leads to multiple, dynamic Traffic Management Initiative (TMI) restrictions being issued by the Air Traffic Control (ATC) on departing flights. This, in turn, propagates delay to the surface of each airport within the metroplex. The NASA Airspace Technology Demonstration 2 (ATD-2) Phase 3 is deployed in D10 to demonstrate new technologies developed to manage the Integrated Arrival, Departure, and Surface (IADS) traffic in a metroplex environment where multiple airports are interacting and sharing resources at the terminal boundary. This paper uses the ATD-2 terminal restriction data collected in the D10 TRACON to quantify the impact of restrictions on the demand, analyze the relation between terminal restrictions and departure taxi time on airport surface, and establish relationships between restrictions and surface delay. We found that the restrictions on departure flights have a direct adverse effect on departure excess taxi time on the airport surface.

ATD-2↗