Determination of copper in tap water using solid-phase spectrophotometry

A new application of ion exchange films is presented. The films are used in a simple analytical method of directly determining low concentrations of Cu(2+) in aqueous solutions, in particular, drinking water. The basis for this new test method is the color and absorption intensity of the ion when adsorbed onto the film. The film takes on the characteristic color of the adsorbed cation, which is concentrated on the film by many orders of magnitude. The linear relationship between absorbance (corrected for variations in film thickness) and solution concentration makes the determinations possible. These determinations agree well with flame atomic absorption determinations.

Hill, Carol M.↗

An artifical corrosion protocol for lap-splices in aircraft skin

This paper reviews the progress to date to formulate an artificial corrosion protocol for the Tinker AFB C/KC-135 Corrosion Fatigue Round Robin Test Program. The project has provided new test methods to faithfully reproduce the corrosion damage within a lap-splice by accelerated means, the rationale for a new laboratory test environment, and a means for corrosion damage quantification. The approach is pragmatic and the resulting artificial corrosion protocol lays the foundation for future research in the assessment of aerospace alloys. The general means for quantification of corrosion damage has been presented in a form which can be directly applied to structural integrity calculations.

Shaw, Bevil J.↗

Adhesion Performance of Solid Film Lubricants on Substrates Cleaned With Environmentally Compliant Cleaners

Solid film adhesion testing was used to determine the effect different environmentally compliant cleaners have on the adhesion properties of solid film lubricants used for several NASA programs. In an action to remove ozone depleting chemicals from aerospace processes, a replacement cleaner must be identified that does not affect the adhesion of solid film lubricants used on flight critical NASA hardware. ASTM D251083 Standard Test Method for Adhesion of Solid Film Lubricants was used to evaluate the cleaners. Two different lubricants - Inlox 88 and Boosterlube - were tested using various commercially available cleaners. Inlox 88 is produced by E/M Corporation and is a liquid oxygen compatible lubricant used in the Space Shuttle Main Engine, and Boosterlube is a new lubricant being implemented for use on the Space Shuttle Solid Rocket Booster. These lubricants were selected because of their specific use on flight critical NASA components. Results of this testing are presented in the paper.

Hall, P. B.↗

Preliminary Radiation Testing of a State-of-the-Art Commercial 14nm CMOS Processor/System-on-a-Chip

Hardness assurance test results of Intel state-of-the-art 14nm “Broadwell” U-series processor / System-on-a-Chip (SoC) for total ionizing dose (TID) are presented, along with exploratory results from trials at a medical proton facility. Test method builds upon previous efforts [1] by utilizing commercial laptop motherboards and software stress applications as opposed to more traditional automated test equipment (ATE).

microprocessor↗

The Adhesion Strength of Impact Ice Measured Using a Modified Lap Joint Test

Numerous methodologies have been utilized to measure the adhesion strength of impact ice, and the data reported in the literature varies significantly from test to test. In order to initiate an investigation to determine the cause of this disparity, a new test methodology has been developed and utilized in the Icing Research Tunnel at the NASA Glenn Research Center. Data was obtained while varying the temperature, test section velocity, and cloud droplet mean volumetric diameter. The first data set acquired using this new test method is presented. New trends demonstrate the effect of annealing ice samples, with temperature being a key variable. Observations during the test and analysis of the results suggest the presence of large residual stresses in the samples.

Work, Andrew H., Jr.↗

Determining Ductile Fracture Toughness in Metals

Ductile fracture toughness determination, such as the J-integral versus crack growth resistance (J-R) curve, is a useful tool for evaluating material structural integrity in the presence of pre-existing defects. The J-R curve represents a way to calculate the work (energy) per unit fracture surface area needed to drive the crack growth. A typical J-R curve is shown in Fig. 1 from which the material fracture toughness near the initiation of stable crack growth (Jq) can be derived. In addition, tearing modulus (TR), representing the material resistance to stable crack growth, can be calculated based on the slope of the J-R curve between two exclusion lines (red dashed lines in Fig. 1). Since the introduction of the J-R curve, extensive efforts have been continuously devoted to develop simplified and reliable methods for determining the material J-R curve. This article briefly reviews three widely-used J-R curve test methods in metals, i.e. elastic unloading compliance (EUC), normalization, and direct current potential drop (DCPD). The main difference in these methods relates to the determination of the crack size. More details of performing the J-R curve determination can be found in ASTM standard E1820-11.

DCPD↗

Contamination of Critical Surfaces from NVR Glove Residues Via Dry Handling and Solvent Cleaning

Gloves are often used to prevent the contamination of critical surfaces during handling. The type of glove chosen for use should be the glove that produces the least amount of non-volatile residue (NVR). This paper covers the analysis of polyethylene, nitrile, latex, vinyl, and polyurethane gloves using the contact transfer and gravimetric determination methods covered in the NASA GSFC work instruction Gravimetric Determination and Contact Transfer of Non-volatile Residue (NVR) in Cleanroom Glove Samples, 541-WI-5330.1.21 and in the ASTM Standard E-1731M-95, Standard Test Method for Gravimetric Determination of Non-Volatile Residue from Cleanroom Gloves. The tests performed focus on contamination of critical surfaces at the molecular level. The study found that for the most part, all of the gloves performed equally well in the contact transfer testing. However, the polyethylene gloves performed the best in the gravimetric determination testing, and therefore should be used whenever solvent contact is a possibility. The nitrile gloves may be used as a substitute for latex gloves when latex sensitivity is an issue. The use of vinyl gloves should be avoided, especially if solvent contact is a possibility. A glove database will be established by Goddard Space Flight Center (GSFC) Code 541 to compile the results from future testing of new gloves and different glove lots.

Sovinski, Marjorie F.↗

Surface fatigue life of CBN and vitreous ground carburized and hardened AISI 9310 spur gears

Spur gear surface endurance tests were conducted to investigate CBN ground AISI 9310 spur gears for use in aircraft applications, to determine their endurance characteristics and to compare the results with the endurance of standard vitreous ground AISI 9310 spur gears. Tests were conducted with VIM-VAR AISI 9310 carburized and hardened gears that were finish ground with either CBN or vitreous grinding methods. Test conditions were an inlet oil temeprature of 320 K (116 F), an outlet oil temperature of 350 K (170 F), a maximum Hertz stress of 1.71 GPa (248 ksi), and a speed of 10,000 rpm. The CBN ground gears exhibited a surface fatigue life that was slightly better than the vitreous ground gears. The subsurface residual stress of the CBN ground gears was approximately the same as that for the standard vitreous ground gears for the CBN grinding method used.

Townsend, Dennis P.↗

Inert and Adsorptive Tracer Tests for Field Measurement of Flow-Wetted Surface Area

Field tests in a discrete rock fracture validated a combined inert/adsorbing tracer test method to estimate the contact area between fluids circulating through a fracture and the bulk rock matrix (i.e., flow-wetted surface area, A). Tracer tests and heat injections occurred at a mesoscale well field in Altona, NY. A subhorizontal bedding plane fracture ~7.6 m below ground surface connects two wells separated by 14.1 m. Recovery of the adsorbing tracer cesium was roughly 72% less than the inert tracer iodide. Using an advection-dispersion-reaction model in one-dimension, the adsorbing/inert tracer method identified substantial flow channelization. These results are consistent with Ground Penetrating Radar (GPR) and thermal sensors. All characterization methods suggest circulating fluids were concentrated in a narrow, 1–2 m wide channel directly connecting the injection and production well. The inert/adsorbing tracer method identified two flow channels with areas of 28 and 80 m 2 . A one-dimensional heat transport model predicted production well temperature rises 20.5°C in 6 days, whereas measured temperature rise was 17.6°C. For comparison, two-dimensional heat transport through a fracture of uniform aperture (i.e., homogeneous permeability) predicted roughly 670 days until production well temperature would rise 17.6°C. This suggests that the use of a fracture of uniform aperture to predict heat transport may drastically overpredict the thermal performance of a geothermal system. In the context of commercial geothermal reservoirs, the results of this study suggest that combined inert/adsorbing tracer tests could predict production well thermal draw-down, leading to improved reservoir monitoring and management.

54 ENVIRONMENTAL SCIENCES↗

Thermal property characterization of phase change materials in building applications: A systematic review of fundamentals, recent progress, and future directions

Phase change materials (PCMs) can reduce building peak loads and enable demand-responsive thermal energy storage (TES), but their deployment depends on reliable measurement and interpretation of thermal properties across laboratory, intermediate, and application scales. Here, this review systematically examines characterization methods, testing protocols, and recent advances for neat PCMs and PCM composites, emphasizing thermal conductivity, enthalpy-related properties (phase change temperature, latent heat, specific heat), and cycling stability. For thermal conductivity, we compare steady-state and transient techniques and note limitations when phase transition and contact resistance affect measurements. For enthalpy–temperature characterization, we discuss differential scanning calorimetry together with intermediate- and bulk-scale methods, including T-history, heat flow meter testing, and three-layer calorimetry (3LC), to generate application-relevant enthalpy–temperature profiles. Cycling stability is organized into four experimental families: thermoelectric–air, fully thermoelectric, water-bath, and in situ chamber approaches, with attention to separating reversible supercooling from true degradation such as phase segregation. We highlight emerging noncontact diagnostics, including infrared thermography and embedded sensing, for spatially resolved validation and multiscale interpretation. Finally, we review the growing use of AI and machine learning for property prediction, inverse characterization from experimental signals, and real-time state estimation in building-integrated TES. Key needs include harmonized protocols, interlaboratory benchmarking, uncertainty reporting, and metadata-rich datasets to accelerate reproducible PCM qualification for grid-flexible buildings.

AI↗

Micromechanical and in situ shear testing of Al–SiC nanolaminate composites in a transmission electron microscope (TEM)

Nanolaminate composites show promise as high strength and toughness materials. Still, due to the limited volume of these materials, micron scale mechanical testing methods must be used to determine the properties of these films. To this end, a novel approach combining a double notch shear testing geometry and compression with a flat punch in a nanoindenter was developed to determine the mechanical properties of these films under shear loading. To further elucidate the failure mechanisms under shear loading, in situ TEM experiments were performed using a double notch geometry cut into the TEM foil. Aluminum layer thicknesses of 50nm and 100nm were used to show the effect of constraint on the deformation. Higher shear strength was observed in the 50 nm sample (690±54 MPa) compared to the 100 nm sample (423±28.7 MPa). Additionally, failure occurred along the Al-SiC interface in the 50 nm sample as opposed to failure within the Al layer in the 100 nm sample.

36 MATERIALS SCIENCE↗

A study on pseudo interface wave technique for CRDM weld defects in nuclear power plants

The nuclear power plant inspection is very important for the safety issue. However due to some radiation and geometric problems, the detection of CRDM(Control Rod Drive Mechanism) can be very difficult by using conventional Ultrasonic Testing method. Also the shrink fit boundary condition can also be an obstacle for the inspection in this paper, instead of conventional Ultrasonic Testing, guided wave was used for the detection of some complicated structures. The CRDM nozzle was installed in reactor head with perfect shrink fit condition by using stainless steel. The wave amplitude distribution on the circumferential direction was calculated with various boundary conditions and the experimental result shows a possibility of the defect detection on J-groove weld.

36 MATERIALS SCIENCE↗

Quantification of stromal vascular cell mechanics with a linear cell monolayer rheometer

Over the past few decades researchers have developed a variety of methods for measuring the mechanical properties of whole cells, including traction force microscopy, atomic force microscopy (AFM), and single-cell tensile testing. Though each of these techniques provides insight into cell mechanics, most also involve some nonideal conditions for acquiring live cell data, such as probing only one portion of a cell at a time, or placing the cell in a nonrepresentative geometry during testing. In the present work, we describe the development of a linear cell monolayer rheometer (LCMR) and its application to measure the mechanics of a live, confluent monolayer of stromal vascular cells. In the LCMR, a monolayer of cells is contacted on both top and bottom by two collagen-coated plates and allowed to adhere. The top plate then shears the monolayer by stepping forward to induce a predetermined step strain, while a force transducer attached to the top plate collects stress information. The stress and strain data are then used to determine the maximum relaxation modulus recorded after step-strain, G{sub r}{sup 0}, referred to as the zero-time relaxation modulus of the cell monolayer. The present study validates the ability of the LCMR to quantify cell mechanics by measuring the change in G{sub r}{sup 0} of a confluent cell monolayer upon the selective inhibition of three major cytoskeletal components (actin microfilaments, vimentin intermediate filaments, and microtubules). The LCMR results indicate that both actin- and vimentin-deficient cells had ∼50% lower G{sub r}{sup 0} values than wild-type, whereas tubulin deficiency resulted in ∼100% higher G{sub r}{sup 0} values. These findings constitute the first use of a cell monolayer rheometer to quantitatively distinguish the roles of different cytoskeletal elements in maintaining cell stiffness and structure. Significantly, they are consistent with results obtained using single-cell mechanical testing methods, suggesting that the rheology-based LCMR technique may be a useful tool for rapid analysis of cell mechanics by shearing an entire cell monolayer.

60 APPLIED LIFE SCIENCES↗

Evaluation of Automated Low-Field NMR Relaxometry For Analysis of Polymers

Screening studies and a Design of Experiment were performed to evaluate measurement variation of a new, non-destructive NMR test system designed to assess age induced degradation of Outer Pressure Pads. The test method and results from 76,746 measurements are described indicating that a metal support strut adjacent to the front position of the test chamber interferes with the measurements and that there is a measurement property gradient from the front to the back of the chamber. Also, obvious compression set areas on a surveillance OPP were not detected, but hidden, internal voids within a newly molded OPP were detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A study of environmental characterization of conventional and advanced aluminum alloys for selection and design. Phase 1: Literature review

A review of the literature is presented with the objectives of identifying relationships between various accelerated stress corrosion testing techniques, and for determining the combination of test methods best suited to selection and design of high strength aluminum alloys. The following areas are reviewed: status of stress-corrosion test standards, the influence of mechanical and environmental factors on stress corrosion testing, correlation of accelerated test data with in-service experience, and procedures used to avoid stress corrosion problems in service. Promising areas for further work are identified.

Sprowls, D. O.↗

Terrestrial photovoltaic cell process testing

The paper examines critical test parameters, criteria for selecting appropriate tests, and the use of statistical controls and test patterns to enhance PV-cell process test results. The coverage of critical test parameters is evaluated by examining available test methods and then screening these methods by considering the ability to measure those critical parameters which are most affected by the generic process, the cost of the test equipment and test performance, and the feasibility for process testing.

Burger, D. R.↗

Nondestructive evaluation of adhesive bond strength using the stress wave factor technique

Acousto-ultrasonic nondestructive evaluation has been conducted to evaluate the adhesive bond strength between rubber and steel plates using the stress wave factor (SWF) measurement technique. Specimens with different bond strength were manufactured and tested using the SWF technique. Two approaches were used to define the SWF. One approach defines the SWF as the signal energy and the other approach defines the SWF as the square root of the zero moment of the frequency spectrum of the received signal. The strength of the rubber-steel adhesive joint was then evaluated using the destructive peel strength test method. It was observed that in both approaches higher values of the SWF measurements correspond to higher values of the peel strength test data. Therefore, these results show that the stress wave factor technique has the potential of being used in quality assurance of the adhesive bond strength between rubber and steel substrates.

Dos Reis, Henrique L. M.↗

Short-crack growth behaviour in various aircraft materials

The results of the first phase of an AGARD Cooperative Test Program on the behavior and growth of short fatigue cracks are reviewed. The establishment of a common test method, means of data collection/analysis and crack growth modeling in an aircraft alloy AA 2024-T3 are described. The second phase allowed testing of various materials and loading conditions. The results of this second phase are described. All materials exhibited a short-crack effect to some extent. The effect was much less evident in 4340 steel than in the other materials. For the aluminum, aluminum-lithium, and titanium alloys, short cracks grew at stress-intensity factor ranges lower, in some cases much lower, than the thresholds obtained from long crack tests. Several laboratories used the same crack growth model to analyze the growth of short cracks. Reasonable agreement was found between measured and predicted short-crack growth rates and fatigue lives.