Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Real-Time Inertia Estimation Tool Implementation Based on Probing Signals

As renewable energy penetration increases and the traditional generators retire in power grids, system inertia decreases and exhibits significant daily fluctuations. Furthermore, fast frequency responses (FFRs) provided by the inverter-based resources (IBRs) begin to playa very critical role and bring new challenges to real-time system inertia monitoring due to the difficulties of quantifying its artificial inertia contribution. Thus, necessitating an accurate real-time inertia estimation tool will not only benefit the secure power grid operations, but also provide insights on assessing the artificial inertia contribution from the IBRs. This paper presents a probing-based real-time inertia estimation tool that has been validated through a power-hardware-in-the-Ioop (PHIL) test system using identical hardware battery energy storage system (BESS) and control in an actual power grid. Preliminary results indicate high estimation accuracy of the developed tool and pave the way for the field test and deployment.

inverter-based resources↗

A Unified Metric for Fast Frequency Response in Low-Inertia Power Systems

Future power systems with more inverter-based resources (IBRs), will be vulnerable to frequency decline contingencies. Fast frequency response (FFR) provided by IBRs is a good candidate to arrest frequency excursions. Diverse types of FFR have been proposed, and some have been deployed in our power systems. Without a unified quantification of FFR, it is hard for the grid operators to compare and fully leverage the FFR capabilities of IBRs. This work introduces a potential unified metric that quantifies two key characteristics of FFR and describes its application to three prevailing FFR types. We then use metric-to-frequency mapping to validate the accuracy of the metric in predicting the impact of a given FFR on the trajectory of a frequency event. The results show that the proposed metric is simple yet accurately captures the ability of diverse forms of FFR to improve system frequency dynamics.

effective inertia↗

Comparison of Electromagnetic Transient and Phasor Dynamic Simulations: Implications for Inverter Dominated Systems

The simulation of very high shares of inverter-based resources in power systems has begun to draw into question the validity of phasor domain tools in capturing relevant dynamics. Electromagnetic transient simulators can capture the dynamics of power electronics with substantially smaller time steps, but are computationally expensive. This work contrasts the results of phasor domain and electromagnetic transient tools for simulations on a validated model of the Maui power system operating at very high inverter-based resource shares with near zero voltage forming devices. The results show that the phasor domain tool predicts optimistic stability with fewer voltage forming elements on the network, and loses computational stability before the electromagnetic transient tool. As the electromagnet transient model is of the entire system, and system-wide discrepancies are observed, this case study of a physical power system highlights the potential need for system-wide detailed modeling during periods of very high shares of inverter-based resources and few voltage forming devices.

electromagnetic transient-domain↗

Interpretable Data-Driven Probabilistic Power System Load Margin Assessment with Uncertain Renewable Energy and Loads

The increasing uncertainties caused by the high-penetration of stochastic renewable generation resources poses a significant threat to the power system voltage stability. To address this issue, this paper proposes a probabilistic deep kernel learning enabled surrogate model to extract the hidden relationship between uncertain sources, i.e., wind power and loads, and load margin for probabilistic load margin assessment (PLMA). Unlike other deep learning approaches, a kernel SHAP provides the sensitivity analysis as well as interpretability of the inputs to outputs influences. This allows identifying the critical factors that affect load margin so that corrective control can be initiated for stability enhancement. Numerical results carried out on the IEEE 118-bus power system demonstrate the accuracy and efficiency of the proposed data-driven PLMA scheme.

deep kernel learning↗

Extended Frequency Divider for Bus Frequency Estimation Considering Virtual Inertia from DFIGs

Accurate estimation of local bus frequency is important for effectively controlling both synchronous and nonsynchronous generators. As the power grid evolves to accommodate essential reliability services such as virtual inertia from nonsynchronous generators, conventional techniques to estimate frequency face challenges. This paper proposes a new frequency estimation method that can effectively include the inertia contributions from double-fed wind generators (DFIGs). This is achieved through the proposed extended frequency divider formula (FDF) to include the contributions of DFIGs via Thevenin equivalents. The proposed extended FDF does not suffer from numerical issues as compared to existing phasor angle derivative-based approaches. Moreover, the knowledge of the rotor speeds of the synchronous machine and DFIGs as well as of the network admittance matrix allows estimating the frequencies of all buses in the grid, thereby significantly improving system situational awareness with a limited number of measurements. Numerical results on the IEEE 39-bus power system with DFIGs show that the proposed method achieves more accurate bus frequency estimations than the original FDF formula and other approaches based on the numerical derivation of the bus voltage phase angles.

double-fed induction generator↗

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

Distributed Frequency Divider for Power System Bus Frequency Online Estimation Considering Virtual Inertia From DFIGs

In this work, a distributed frequency divider is proposed to estimate power system bus frequency with a limited number of PMUs while considering the inertial contributions from double-fed induction generators (DFIGs). The key idea is to reformulate the original frequency divider by modeling the contributions of DFIGs with inertia emulation and external regional power system through Thevenin equivalents. The distributed frequency divider is general and able to estimate local bus frequencies in a distributed manner. Besides, only the knowledge of the rotor speeds of synchronous generator, boundary bus frequencies and terminal bus frequencies of DFIGs as well as the admittance matrix are required to estimate the frequencies at all buses. This is drastically different from existing approaches that require system observability by PMUs to monitor all bus frequencies. Numerical results carried out on the IEEE 39-bus and modified 118-bus power systems with DFIGs demonstrate and effectiveness and robustness of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of First-Order Gratings in Silicon Photonic Waveguides

A simple thin film effective index analysis for first order gratings in Si photonic waveguides is shown to provide highly accurate results for reflected and transmitted power spectrums as long as the waveguide remains single mode and non-radiating. A cover layer can be added to the grating region of a Si photonic waveguide to increase the strength of the grating, modify transition losses from the input waveguide to the grating waveguide region, and/or modify the width of the reflectivity spectrum. For a given grating period, the peak reflection and spectral width of the reflectivity decrease as the duty cycle is decreased or increased from ~50%. For both radiating and multimode structures, the coupling between all modes, power radiated towards the superstrate (upwards), power radiated downwards (substrate) and transmitted power analyzed by Floquet-Bloch, Eigenmode Expansion and Finite Difference Time Domain methods show excellent agreement. Coupling coefficients calculated using analytic formulas are shown to be accurate only for shallow grating depths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Power System Network Reduction for Power Hardware-in-the-Loop Simulation

This paper proposes single-port equivalent and two-port equivalent network reduction methods to respectively reduce single-port and two-port areas in a large power network. Parameters of the reduced systems are rigorously derived, which guarantees that the electrical quantities at the port(s) remain unchanged over the reduction, including voltage magnitude and phase and active and reactive power injections into the area to be reduced. The proposed techniques are applied to reduce a practical Maui grid, where the total numbers of buses, lines and transformers are respectively reduced from 212, 106 and 108 to 45, 30 and 13. Dynamic behaviors between the full model and the reduced model are compared in detail to illustrate the efficacy and accuracy of the proposed network reduction.

model reduction↗

A Comparison of Machine Learning Methods for Frequency Nadir Estimation in Power Systems

An increasing penetration level of inverter-based renewable energy resources changes the inertia of power systems, posing challenges for maintaining the desired system frequency stability. An accurate frequency nadir estimation is crucial for power system operators to prepare preventive actions against large frequency excursions. In this paper, five machine learning methods - linear regression, gradient boosting, support vector regression, an artificial neural network, and XGBoost - are applied to two different datasets, i.e., 1) the unit generation dataset and 2) the system total inertia and headroom dataset, for the prediction of the frequency nadir. The training and testing datasets are generated through extensive generation scheduling simulations using Multi-timescale Integrated Dynamic and Scheduling (MI-DAS) toolbox on the Western Electricity Coordinating Council 240-bus system with high renewable penetration levels. Numerical results show that all five machine learning methods perform well in predicting the nadir frequency of the system. Among them, the gradient boosting and the XGBoost are clear winners yielding the best prediction accuracy in terms of four evaluation metrics.

data driven↗

Stabilizing Inverter-Based Transmission Systems: Power Hardware-in-the-Loop Experiments with a Megawatt-Scale Grid-Forming Inverter

This article presents what the authors believe to be the first experimental verification of the ability of grid-forming (GFM) inverters to stabilize a transmission electric power system that is otherwise unstable. The experiments described here were performed using power hardware-in-the-loop (PHIL) simulation to connect a megawatt-scale battery inverter to a real-time electromagnetic transient (EMT) simulation of the near-future Maui power system. This allows the dynamic interactions between the inverter and the power system to be observed without putting the real power system at risk. The ability to use the actual inverter hardware removes the need to rely on a computer model approximation of the inverter's behavior.

electromagnetic transient simulations↗

ICED: An Integrated CGRA Framework Enabling DFVS-Aware Acceleration

oarse-grained reconfigurable arrays (CGRAs) are a promising solution to enable energy-efficient acceleration of applications from different domains. By leveraging reconfiguration at the functional level, they can adapt to significantly different computational patterns. Existing CGRA mapping approaches extract instruction-level parallelism, exploit loop-pipelining opportunities, guarantee the data dependency, and target high throughput of a given loop. However, the recurrence data-dependency in the DFG and the mismatch between required and available computing/communication resources complicate the mapping, and might lead to significant unbalances in the utilization of the CGRA's tiles. This results in wasted power for tiles with low utilization. Applying dynamic voltage and frequency scaling (DVFS) can potentially solve this challenge and improve energy efficiency by adjusting voltage and frequency of different tiles independently. CGRAs have also been successful in accelerating data-dependent streaming applications. However, in these applications, the execution time of each kernel in the pipeline might dynamically vary depending on the characteristics of the input. This also leads to under-utilization of resources for the dynamically changing kernels that do not limit the application throughput. DVFS can also improve energy efficiency for these applications by dynamically changing the voltage and frequency levels of tiles that host non performance-constraining kernels. This paper proposes ICEDTEA -- an integrated DVFS-aware framework to map applications on CGRAs that support power islands. ICEDTEA proposes a CGRA architecture supporting DVFS islands at varying granularity (from a single tile to a group of tiles) and the related DVFS-aware compilation and mapping toolchain. ICEDTEA is the first work that introduces DVFS support for spatio-temporal CGRAs at power-island levels. The experimental evaluation shows that ICEDTEA improves average utilization by 2.3$\times$ and energy-efficiency by 1.32$\times$ over a conventional CGRA. With streaming applications, ICEDTEA improves energy efficiency by 1.12$\times$ over a state-of-the-art CGRA that introduces partial dynamic reconfiguration to adapt to variations in kernels' throughput.

Tan, Cheng↗

Bridging Python to Silicon: The SODA Toolchain

Systems performing scientific computing, data analysis, and machine learning tasks have a growing demand for application-specific accelerators that can provide high computational performance while meeting strict size and power requirements. However, the algorithms and applications that need to be accelerated are evolving at a rate that is incompatible with manual design processes based on hardware description languages. Agile hardware design tools based on compiler techniques can help by quickly producing an application-specific integrated circuit (ASIC) accelerator starting from a high-level algorithmic description. Here, we present the software-defined accelerator (SODA) synthesizer, a modular and open-source hardware compiler that provides automated end-to-end synthesis from high-level software frameworks to ASIC implementation, relying on multilevel representations to progressively lower and optimize the input code. Our approach does not require the application developer to write any register-transfer level code, and it is able to reach up to 364 giga floating point operations per second (GFLOPS)/W efficiency (32-bit precision) on typical convolutional neural network operators.

97 MATHEMATICS AND COMPUTING↗

Same Goal, Different Pathways for Energy Transition: A More Holistic, Multisector, Community-Driven Approach

Low- and zero-carbon power systems are central to global decarbonization efforts. Costs for renewable energy (RE) and storage have fallen significantly, and advances in technologies and practices have improved the grid flexibility and stability needed to maintain the reliability of high-RE systems. Zero-carbon power systems, in turn, enable deep decarbonization through the electrification of other sectors, including transportation, buildings, and industry.

100% clean electricity↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Quality Analysis and Solutions for Distribution-Level PMUs

Synchrophasors provide promising enhancement to the distribution system monitoring. However, different from transmission systems, distribution systems are usually with higher noise, phase unbalance, and distributed energy resources. All of these could impair the data quality of distribution-level phasor measurement units (D-PMUs) and thus deteriorate the performance of D-PMU based applications. Therefore, the data quality of D-PMU should be evaluated to ensure the effectiveness of D-PMU based applications. In this paper, factors in distribution systems that could jeopardize D-PMU data quality are evaluated. The impact of data quality on D-PMU applications is analyzed. Finally, solutions are proposed to improve D-PMU data quality to satisfy these requirements. This work provides effective methods to improve the performance of distribution-level grid monitoring using synchrophasor measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗