The ATLAS tile calorimeter performance at the LHC

The Tile Calorimeter (TileCal), the central section of the hadronic calorimeter of the ATLAS experiment, is a key detector component to detect hadrons, jets and taus and to measure the missing transverse energy. Due to the very good muon signal to noise ratio it assists the spectrometer in the identification and reconstruction of muons. TileCal is built of steel and scintillating tiles coupled to optical fibers and read out by photomultipliers. The calorimeter is equipped with systems that allow to monitor and to calibrate each stage of the read out system exploiting different signal sources: laser light, charge injection and a radioactive source. The performance of the calorimeter has been measured and monitored using calibration data, random triggered data, cosmic muons and more importantly LHC collision events. The results presented here assess the absolute energy scale calibration precision, the energy and timing uniformity and the synchronization precision. The ensemble of the results demonstrates a very good understanding of the performance of the Tile Calorimeter that is proved to be well within the design expectations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security

Pulse-shape discrimination (PSD) in fast, organic scintillation detectors is a long-established technique used to separate neutrons and {gamma} rays in mixed radiation fields. In the analogue domain the method can achieve separation in real time, but all knowledge of the pulses themselves is lost thereby preventing the possibility of any post- or repeated analysis. Also, it is typically reliant on electronic systems that are largely obsolete and which require significant experience to set up. In the digital domain, PSD is often more flexible but significant post-processing has usually been necessary to obtain neutron/{gamma}-ray separation. Moreover, the scintillation media on which the technique relies usually have a low flash point and are thus deemed hazardous. This complicates the ease with which they are used in industrial applications. In this paper, results obtained with a new portable digital pulse-shape discrimination instrument are described. This instrument provides real-time, digital neutron/{gamma} separation whilst preserving the synchronization with the time-of-arrival for each event, and realizing throughputs of 3 x 10{sup 6} events per second. Furthermore, this system has been tested with a scintillation medium that is non-flammable and not hazardous. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of WDM/Pulse-Position-Modulation (WDM/PPM) with Code/Pulse-Position-Swapping (C/PPS) Based on Wavelength/Time Codes

Pulse position modulation (PPM) signaling is favored in intensity modulated/direct detection (IM/DD) systems that have average power limitations. Combining PPM with WDM over a fiber link (WDM/PPM) enables multiple accessing and increases the link's throughput. Electronic bandwidth and synchronization advantages are further gained by mapping the time slots of PPM onto a code space, or code/pulse-position-swapping (C/PPS). The property of multiple bits per symbol typical of PPM can be combined with multiple accessing by using wavelength/time [W/T] codes in C/PPS. This paper compares the performance of WDM/PPM and C/PPS for equal wavelengths and bandwidth.

42 ENGINEERING↗

Empirical Evaluation of GPS Clock Accuracy for Isochronous Droop-based Inverters

Grid-forming inverters rely upon an internal reference to regulate the grid 's voltage and frequency. Without a reliable reference, issues such as loss of synchronism, frequency instability, and unequal power sharing can occur. One proposed internal phase reference for grid-forming inverters is generated by the controller's clock, but this is affected by nonidealities in the crystal oscillator leading to time drift in the phase reference. To improve the controller's clock accuracy, the Global Positioning System (GPS) can be used to calibrate the internal clock. Previously, GPS-based clock calibration was explored theoretically and various methods were developed for mitigating frequency/phase drift at the power system level. This paper experimentally validates the direct performance of GPS time-calibration at the controller level and justifies its use in maintaining an accurate phase reference for droop-based grid-forming inverters.

clock drift↗

Development of a Practical Secondary Control for Hardware Microgrids

Practical, vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that operates with all GFM IBRs and synchronous generators. This secondary control does not require the use of additional measurement devices in the MG and utilizes the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus registers, such as packet loss and quantization error, and their detrimental impacts on secondary control actions are investigated. The proposed three-stage modification for any secondary control architecture to mitigate these impacts includes: 1) averaging the data read, 2) situational event-triggering of the controller, and 3) finite iteration of the controlling action. The proposed method is validated using a 3-..phi.., 480 V, 60 Hz, 500 kVA laboratory hardware microgrid with commercial two GFM IBRs and one diesel generator. The experimental results corroborates the fact the proposed modification in the secondary control architecture is advantageous for practical usage under erroneous measurements.

communication systems↗

Grey-Box System Identification of Grid-Forming Inverters

This paper demonstrates the use of grey-box system identification methods for simplifying and understanding the nonlinear power dynamics of grid-forming inverters (GFMs). The power and frequency outputs of complex high-order GFM models are fed into system identification software in order to fit them to a predetermined LTI system and learn system parameters such as (synthetic) inertia and droop constants. The same process is then run for a high-order synchronous generator model, and the outputs are fit to the same set of LTI equations. Simulation of a network of GFM inverters with diverse control architecture is also performed for the same process. The intent is threefold: first, to demonstrate the appropriateness of unified LTI models for describing the power and frequency dynamics of individual resources and connected networks, in order to facilitate analysis of larger heterogeneous networked systems; second, to discover the relationship between internal control parameters of GFMs and their externally observed values; and third, to validate that grey-box data-driven system identification techniques can be a valuable tool to discover the values of important parameters in the absence of explicit vendor models.

analytical models↗

Stability Assessment of a System Comprising a Single Machine and a Virtual Oscillator Controlled Inverter with Scalable Ratings

We present a small-signal stability study of a coupled synchronous generator and inverter system, where the inverter is controlled by virtual oscillator control (VOC). VOC is a recently proposed grid-forming inverter control strategy, which acts on faster time scales compared to droop control. In our study, we leverage a scalable VOC controller (that is by design agnostic of power levels) to test the system's small-signal stability at different inverter penetration levels. The impact of rotational inertia, reactive power support, and filter parameters on stability is then investigated. Results highlight possible issues that might arise in these mixed machine-inverter systems further motivating the need to develop next generation stabilizing grid-forming controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of Seamless Microgrid Transition Operation Using Grid-Forming Inverters

This paper investigates operational techniques to achieve seamless (smooth) microgrid (MG) transitions by dispatching a grid-forming (GFM) inverter. In traditional approaches, the GFM inverter must switch between grid-following (GFL) and GFM control modes during MG transition operation. Today's inverter technology allows GFM inverters to always operate in GFM control mode, so it is worth exploring how to use them to achieve smooth MG transition operation. This paper proposes three operational techniques: a traditional scheme of switching between GFL and GFM control; a new scheme of consistent GFM control and shifting the droop intercept up before islanding operation; and a new scheme of consistent GFM control and shifting the droop intercept up before synchronization operation. A full hardware setup is established to compare the three techniques and showcase their implementations in real-world applications. The results show that the third technique outperforms the others and exhibits the best transition performance because the GFM inverter maintains the same operating points during the transition operation. Therefore, we conclude that ensuring smooth MG transition operation requires that the GFM inverter(s) maintain the same operating points (v, f, P, Q, and phase angle) during the transition operation in addition to minimizes the point of common coupling power flow.

grid-forming control↗

Mitigating Voltage Instability in the Saudi Grid for a Decarbonized, Fully Solar Power System

Lately, solar photovoltaic (PV) has received significant interest due to its economic and environmental benefits. As the integration of renewable energy sources (RES) increases into existing power grids, challenges such as the decrease in short circuit ratio (SCR) are introduced. Here, this paper investigates a case study of the Saudi power grid, examining the voltage stability as the grid transitions from traditional power generation to 100% penetration of solar PV gradually. Moreover, the paper explores the relationship between the increase in solar penetration and the potential effects on the short circuit MVA (SCMVA), which could significantly impact the overall SCR of the system. To meet the North American Electric Reliability Corporation (NERC) recommendation of maintaining SCR at a particular level, synchronous condensers (SC)s were integrated into the grid. The effectiveness of utilizing SCs to maintain the system voltage at optimal levels in a fully solar grid is also considered. In addition, this paper covers the weak grid analysis via utilizing the Newton-Raphson load flow method, along with PV and QV curve analyses. The purpose behind that is to determine weak bus locations in need of voltage improvements, and to meet the amount of reactive power to be injected. Finally, the amount of power being delivered by SCs will be added progressively in three scenarios to show the enhancements on SCR more precisely.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular Spiking Neural Circuits for Mapping Long Short-Term Memory on a Neurosynaptic Processor

Due to the distributed and asynchronous nature of neural computation through low-energy spikes, brain-inspired hardware systems offer high energy efficiency and massive parallelism. One such platform is the IBM TrueNorth neurosynaptic system. Recently, TrueNorth compatible representation learning algorithms have emerged, achieving close to the state-of-the-art performance in various data sets. However, its application in temporal sequence processing models, such as recurrent neural networks (RNNs), is still only at the proof of concept level. There is an inherent difficulty in capturing temporal dynamics of an RNN using spiking neurons, which is only exasperated by the hardware constraints in connectivity and synaptic weight resolution. This paper presents a design flow that overcomes these difficulties and maps a special case of recurrent networks called long short-term memory (LSTM) onto a spike-based platform. The framework utilizes various approximation techniques, such as activation discretization, weight quantization, and scaling and rounding, spiking neural circuits that implement the complex gating mechanisms, and a store-and-release technique to enable neuron synchronization and faithful storage. While the presented techniques can be applied to map LSTM to any spiking neural network (SNN) simulator/emulator, here we choose the TrueNorth chip as the target platform by adhering to its hardware constraints. Three LSTM applications, parity check, extended Reber grammar, and question classification, are evaluated. The tradeoffs among accuracy, performance, and energy tradeoffs achieved on TrueNorth are demonstrated. Finally, this is compared with the performance on an SNN platform without hardware constraints, which represents the upper bound of the achievable accuracy.

97 MATHEMATICS AND COMPUTING↗

Pathways to the Next-Generation Power System With Inverter-Based Resources: Challenges and recommendations

Managing the stability of today's electric power systems is based on decades of experience with the physical properties and control responses of large synchronous generators. Today's electric power systems are rapidly transitioning toward having an increasing proportion of generation from nontraditional sources, such as wind and solar (among others), as well as energy storage devices, such as batteries. In addition to the variable nature of many renewable generation sources (because of the weather-driven nature of their fuel supply), these newer sources vary in size - from residential-scale rooftop systems to utility-scale power plants - and they are interconnected throughout the electric grid, both from within the distribution system and directly to the high-voltage transmission system. Most important for our purposes, many of these new resources are connected to the power system through power electronic inverters. Collectively, we refer to these sources as inverter-based resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Forming Inverter-Based Resource Research Landscape: Understanding the Key Assets for Renewable-Rich Power Systems

The shift to net zero energy systems has changed the face of our power grid. Traditional large-scale synchronous generators found inside coal and natural gas plants are being replaced with inverter-based resource (IBR) technologies. This transition to an IBR-dominant power grid introduces new characteristics, altering how our grid operates. Therefore, the role of IBRs has expanded, requiring them to provide a range of essential services to keep our grid reliable, resilient, and secure.

energy management↗

The North American SynchroPhasor Initiative (NASPI)

Abstract--The North American SynchroPhasor Initiative (NASPI) is a joint effort between the U.S. Department of Energy (DOE) and the North American Electric Reliability Corporation (NERC) to improve power system reliability through wide-area measurement, monitoring and control by facilitating a robust, widely available and secure synchronized data measurement infrastructure for the interconnected North American electric power system with associated analysis and monitoring tools for better planning and operation, and improved reliability. This presentation will provide an overview of NASPI, including recent accomplishments, current status, and planned activities

electric variables measurement↗

Closed-Form Solution for Synchrophasor Data Correction under GPS Spoofing Attack

Phasor Measurement Units (PMUs) are increasingly being deployed to augment monitoring, protection and control applications in the power grid. PMUs rely on the Global Positioning System (GPS) for generation of time-synchronized and accurate measurements. However, civilian GPS signals, being unencrypted, are susceptible to GPS spoofing attacks (GSA). Hence ensuring the integrity of GPS-timing dependent synchrophasor data has become critical. In this paper, a closed-form analytical solution for estimating the GSA phase shift has been proposed and integrated to the spoofing detection & correction framework. Extensive simulations have been performed in order to verify the accuracy of the solution in determining the location and the phase shift of the compromised PMU. Time domain dynamic simulations presented in this paper demonstrate the applicability of the proposed solution for near-real-time detection of GSA, and this will enable faster detection and correction of phase angles of compromised synchrophasor data.

Synchrophasor, PMUs, GPS, Spoofing, Data Correctio↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states. For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management systems↗

Optimum Full Information, Unlimited Complexity, Invariant and Minimax Clock Skew and Offset Estimators for IEEE 1588

This paper presents the problem of clock skew and offset estimation for the IEEE 1588 precision time protocol. Built on the classical two-way message exchange scheme, IEEE 1588 is a prominent synchronization protocol for packet switched networks. Because of the presence of random queuing delays in a packet switched network, the joint recovery of clock skew and offset from the received packet timestamps can be viewed as a statistical estimation problem. Recently, assuming perfect clock skew information, minimax optimum clock offset estimators were developed for IEEE 1588. Building on this work, we first develop joint optimum invariant clock skew and offset estimators for IEEE 1588 for known queuing delay statistics and unlimited computational complexity. We then show the developed estimators are minimax optimum, i.e., these estimators minimize the maximum skew normalized mean square estimation error over all possible values of the unknown parameters. Minimax optimum estimators that utilize information from past timestamps to improve accuracy are also introduced. The developed optimum estimators provide useful fundamental limits for evaluating the performance of clock skew and offset estimation schemes. These performance limits can aid system designers to develop algorithms with the desired computational complexity that achieve performance close to the performance of the optimum estimators. If a designer finds an approach with a complexity they find acceptable and which provides performance close to the optimum performance, they can use it and know they have near optimum performance. This is precisely the approach used in communications when comparing to capacity.

Cellular networks↗

Large Angle Deviation in Grid-Following IBRs Upon Grid Voltage Dip

In the 2021 Texas Odessa large-scale solar PV tripping events, phase-locked-loop (PLL) loss of synchronism is identified as a major cause of solar PV tripping. When solar PVs detected a large phase angle deviation (e.g., 10 degrees), tripping commands were initiated. Here, the large phase angle deviation was triggered by a transmission line fault 200 miles away, which in turn led to approximately 30% voltage drop in the 345-kV system. This paper offers a plausible reason why grid-following inverter-based resources (IBRs) may experience a large angle deviation upon grid voltage dip. Critical operating conditions contributing to such phenomena are identified via analysis and their effects are demonstrated using electromagnetic transient (EMT) simulation. Furthermore, the effect of converter control, e.g., grid-following control vs. grid-forming control, is examined. It is found from EMT simulation results that frequency and voltage control are helpful in mitigating angle deviation. Furthermore, linear block diagrams are derived to examine why frequency control can effectively suppress large angle deviation.

14 SOLAR ENERGY↗

Novel Rotary Transformer Topology With Improved Power Transfer Capability for High-Speed Applications

This article proposes a new rotary transformer topology enabling reduction of leakage inductances and significant improvement of power transfer capability compared to traditional topologies thanks to its interleaved windings and resonant compensation circuits. The proposed rotary transformer features a nonferrite rotating part made of lightweight strong nonconductive and nonmagnetic composite material and a large air gap, allowing safe operation at high rotational speeds. Hence, this novel rotary transformer can enable the adoption of wound rotor synchronous machines for electric or hybrid vehicle traction. Finally, the performance of the proposed new topology was evaluated and compared to the conventional one. Significant performance improvement was confirmed. A 10-kW proof of concept prototypes was built, and the test has validated the power transfer capability with 95.9% efficiency.