Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

System level electrochemical principles

The traditional electrochemical storage concepts are difficult to translate into high power, high voltage multikilowatt storage systems. The increased use of electronics, and the use of electrochemical couples that minimize the difficulties associated with the corrective measures to reduce the cell to cell capacity dispersion were adopted by battery technology. Actively cooled bipolar concepts are described which represent some attractive alternative system concepts. They are projected to have higher energy densities lower volumes than current concepts. They should be easier to scale from one capacity to another and have a closer cell to cell capacity balance. These newer storage system concepts are easier to manage since they are designed to be a fully integrated battery. These ideas are referred to as system level electrochemistry. The hydrogen-oxygen regenerative fuel cells (RFC) is probably the best example of the integrated use of these principles.

Thaller, L. H.↗

Geomancy: Automated Performance Enhancement through Data Layout Optimization

Large distributed storage systems such as high- performance computing (HPC) systems used by national or international laboratories require sufficient performance and scale for demanding scientific workloads and must handle shifting workloads with ease. Ideally, data is placed in locations to optimize performance, but the size and complexity of large storage systems inhibit rapid effective restructuring of data layouts to maintain performance as workloads shift. To address these issues, we have developed Geomancy, a tool that models the placement of data within a distributed storage system and reacts to drops in performance. Using a combination of machine learning techniques suitable for temporal modeling, Geomancy determines when and where a bottleneck may happen due to changing workloads and suggests changes in the layout that mitigate or prevent them. Our approach to optimizing throughput offers benefits for storage systems such as avoiding potential bottlenecks and increasing overall I/O throughput from 11% to 30%.

Bel, Oceane M.↗

The storage performance of automotive cryo-compressed hydrogen vessels

Cryo-compressed hydrogen storage promises to deliver the highest system storage density leading to practical vehicles with range comparable to today's gasoline vehicles and fundamental cost and safety advantages. Yet, cryogenic vessels are complex systems, continuously drifting in thermodynamic space depending on use patterns, insulation performance, vessel characteristics, liquid hydrogen pump performance, and para-H 2 to ortho-H 2 conversion. In this paper, cryogenic vessel fill density results from a previous publication are extended to calculate system storage performance, including volumetric (gH 2 /L), gravimetric (H 2 weight fraction), and vent losses over a broad range of conditions. The results validate previous experiments and models indicating that cryogenic pressure vessels have maximum system density of all available storage technologies while avoiding vent losses in all but the most extreme situations. Design pressures in the range 250–350 bar seem most advantageous due to high system density and low weight and cost, although determining an optimum pressure demands a complete economic and functional analysis. Future insulation, vessel, and liquid hydrogen pump improvements are finally analyzed that, while not experimentally exhibited to date, show promise of being feasible in the future as their level of technical maturity increases, leading to maximum H 2 storage performance for cryo-compressed storage. If proven feasible and incorporated into future cryogenic vessels, these improvements will enable 50 + gH 2 /L system density at 10+% H 2 weight fraction.

08 HYDROGEN↗

Synergies Between Building-Sited Batteries and Thermal Energy Storage

As renewable penetration increases, there is a greater need for energy storage systems located at buildings. This storage can include batteries, which directly shift the metered load, or thermal energy storage, which shifts thermal-driven electric loads like air conditioning. This presentation covers modeling results of the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. It also shows how battery storage can expand the usefulness of thermal energy storage for electric load shaving, and how thermal storage can lower the cost of the overall storage system and extend battery lifetime by reducing cycling.

batteries↗

Economics of internal and external energy storage in solar power plant operation

A simple approach is formulated to investigate the effect of energy storage on the bus-bar electrical energy cost of solar thermal power plants. Economic analysis based on this approach does not require detailed definition of a specific storage system. A wide spectrum of storage system candidates ranging from hot water to superconducting magnets can be studied based on total investment and a rough knowledge of energy in and out efficiencies. Preliminary analysis indicates that internal energy storage (thermal) schemes offer better opportunities for energy cost reduction than external energy storage (nonthermal) schemes for solar applications. Based on data and assumptions used in JPL evaluation studies, differential energy costs due to storage are presented for a 100 MWe solar power plant by varying the energy capacity. The simple approach presented in this paper provides useful insight regarding the operation of energy storage in solar power plant applications, while also indicating a range of design parameters where storage can be cost effective.

Manvi, R.↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

Improvements in magnetic bearing performance for flywheel energy storage

The paper considers the development of a 500-Watt-hour magnetically suspended flywheel stack energy storage system. The work includes hardware testing results from a stack flywheel energy storage system, improvements in the area of noncontacting displacement transducers, and performance enhancements of magnetic bearings. Experimental results show that a stack flywheel energy storage system is feasible technology.

Plant, David P.↗

Hierarchical storage management system evaluation

The Numerical Aerodynamic Simulation (NAS) Program at NASA Ames Research Center has been developing a hierarchical storage management system, NAStore, for some 6 years. This evaluation compares functionality, performance, reliability, and other factors of NAStore and three commercial alternatives. FileServ is found to be slightly better overall than NAStore and DMF. UniTree is found to be severely lacking in comparison.

Woodrow, Thomas S.↗

Quantifying and Addressing the DOE Material Reactivity Requirements with Analysis and Testing of Hydrogen Storage Materials & Systems

The objective of this project is to examine safety aspects of candidate hydrogen storage materials and systems being developed in the DOE Hydrogen Program. As a result of this effort, the general DOE safety target will be given useful meaning by establishing a link between the characteristics of new storage materials and the satisfaction of safety criteria. This will be accomplished through the development and application of formal risk analysis methods, standardized materials testing, chemical reactivity characterization, novel risk mitigation approaches and subscale system demonstration. The project also will collaborate with other DOE and international activities in materials based hydrogen storage safety to provide a larger, highly coordinated effort.

08 HYDROGEN↗

Cybersecurity Assessments on Emulated DER Communication Networks

An increasing number of public utility commissions are adopting Distributed Energy Resource (DER) interconnection standards which require photovoltaic (PV) inverters, energy storage systems, and other DER to include interoperable grid-support functionality. The recently updated national standard, IEEE 1547-2018, requires all DER to include a Sun Spec Modbus, IEEE 2030.5, or IEEE 1815 communication interface in order to provide local and bulk power system services. Those communication protocols and associated information models will ensure system interoperability for PV and storage systems, but these new utility-to-DER communication networks must be deployed with sufficient cybersecurity to protect the U.S. power system and other critical infrastructure reliant on dependable power. Unlike bulk generators, DER are commonly connected to grid operators via public internet channels. These DER networks are exposed to a large attack surface that may leverage sophisticated techniques and infrastructure developed on IT systems, including remote exploits and distributed attacks. Although DER make up a growing portion of the national generation mix, they have limited processing capabilities and do not typically support modern security features such as encryption or authentication. In this work, Sandia National Laboratories constructed simulated DER communication net- works with a range of security features in order to study the security posture of different communication approaches. The experimental test environment was created in a Sandia-developed co-simulation platform, called SCEPTRE, which emulated Sun Spec-compliant DER equipment, the utility DER management system, communication network, and distribution power system. Adversary-based assessments were conducted and a quantitative scoring criteria was applied to evaluate the resilience of various architectures against cyber attacks and to measure the systemic impact during such attacks. The team found that network segmentation, encryption, and moving target defense improved the security of these networks and would be recommended for utility, aggregator, and local DER networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The development of a residential heating and cooling system using NASA derived technology

A study to determine the technical and economic feasibility of a solar-powered space heating, air-conditioning, and hot water heating system for residential applications is presented. The basic system utilizes a flat-plate solar collector to process incident solar radiation, a thermal energy storage system to store the collected energy for use during night and heavily overcast periods, and an absorption cycle heat pump for actually heating and cooling the residence. In addition, heat from the energy storage system is used to provide domestic hot water. The analyses of the three major components of the system (the solar collector, the energy storage system, and the heat pump package) are discussed and results are presented. The total system analysis is discussed in detail, including the technical performance of the solar-powered system and a cost comparison between the solar-powered system and a conventional system. The projected applicability of the system to different regions of the nation is described.

Oneill, M. J.↗

Advanced Concepts for Dry Storage Cask Thermal-Hydraulic Testing

The purpose of this report is to review technical issues relevant to the performance evaluation of dry storage systems during vacuum drying and long-term storage operations. It also provides updates on experimental components under development that are vital for pursuing advanced studies. Validation of the extent of water removal in a multi-assembly dry storage system using an industrial vacuum drying procedure is needed, as operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. Water remaining in canisters/casks upon completion of vacuum drying can lead to cladding corrosion, embrittlement, and breaching, as well as fuel degradation. Therefore, additional information is needed to evaluate the potential impacts of water retention on extended long-term dry storage. A general lack of data and experience modeling the drying process necessitates the testing of advanced concepts focused on the simulation of industrial vacuum drying. Smaller-scale tests that incorporate relevant physics and well-controlled boundary conditions are necessary to provide insight and guidance to the modeling of prototypic systems undergoing drying processes. This report describes the development and testing of waterproof, electrically-heated spent fuel rod simulators as a proof of concept to enable experimental simulation of the entire dewatering and drying process. This report also describes the preliminary development of specially-designed, unheated mock fuel rods for monitoring internal rod pressures and studying water removal from simulated failed fuel rods. A variety of moisture monitoring instrumentation is also being considered and will be downselected for the tracking of dewpoints of gas samples. The effects of cladding oxidation and crud on water retention in dry storage systems can be explored via separate effects tests (SETs) that would measure chemisorbed and physisorbed water content on cladding samples. The concepts listed above will be incorporated into an advanced dry cask simulator with multiple fuel assemblies in order to account for important inter-assembly heat-transfer physics. Plans are described for harvesting up to five full-length 5x5 laterally truncated assemblies from commercial 17x17 PWR skeleton components with the goal of constructing this simulator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Trade-off study of data storage technologies

The need to store and retrieve large quantities of data at modest cost has generated the need for an economical, compact, archival mass storage system. Very significant improvements in the state-of-the-art of mass storage systems have been accomplished through the development of a number of magnetic, electro-optical, and other related devices. This study was conducted in order to do a trade-off between these data storage devices and the related technologies in order to determine an optimum approach for an archival mass data storage system based upon a comparison of the projected capabilities and characteristics of these devices to yield operational systems in the early 1980's.

Kadyszewski, R. V.↗

THERMAL MODELING OF HANFORD LEAD CANISTER’S HEATER BENCH TESTS

A computational fluid dynamics (CFD) model was built to simulate planned testing of heater assemblies for the Hanford Lead Canister (HLC) project. The HLC is a canister storage system that will contain heaters to simulate the decay heat of nuclear material and provide the canister storage system with environmental conditions equivalent to the operating conditions on a dry storage pad. The HLC will be equipped with long-term data collection and monitoring systems to provide an early warning of corrosion, pitting, cracking, or other signs of canister degradation that might threaten the integrity of the containment boundary over the potentially long term of dry storage. An important part of the HLC development is to confirm the function and ability of the electric heater assemblies that were specially designed to provide heating similar to the decay heat of nuclear material contained within the canister storage system. Heater bench testing is planned for early 2022 in a test configuration that does not include the canister. The goal of the bench testing is to verify that the heaters can replicate the decay heat of a canister with nuclear material and to validate the thermal models, which are critical to understanding the HLC’s thermal environment, including the local air flow within the canister storage system. Testing of the heater assemblies inside the canister system are planned in the future to validate canister level thermal models, and rigorous pre-deployment testing of the complete HLC cask and canister system is intended to be completed before the HLC is deployed in the 2025-2026 timeframe. This study presents the pre-test temperature predictions of the bench testing. A description of the heater assemblies and planned bench testing is presented. The model was developed with the commercial CFD code STAR-CCM+. An uncertainty analysis was run with the CFD model to determine the uncertainty in the temperature predictions and provide a range over which the predicted temperatures are expected to vary. The uncertainty analysis was performed by coupling STAR-CCM+ with the software Dakota, which provides advanced parametric analyses, including quantification of margins and uncertainty with computational models. This work is expected to provide insight into SNF canister behavior.

Suffield, Sarah R.↗

Energy storage for low earth orbit operations at high power

Results are presented of an in-house study of relative sizes and technology needs of three energy storage systems for high power, low earth orbit power systems. The systems compared are nickel-cadmium batteries, nickel-hydrogen batteries, and regenerative fuel cell systems (RFCS). RFCS based on hydrogen-oxygen and hydrogen-chlorine reactants are examined. Those components of the total power system which are significantly impacted by energy storage system selection; e.g., solar array, reactant storage tanks and radiator sizes, are included incrementally in the weights of the systems compared.

Trout, J. B.↗

Simulation of hydrogen adsorption systems adopting the flow through cooling concept

Hydrogen storage systems based on adsorbent materials have the potential of achieving the U.S. Department of Energy (DOE) targets, especially in terms of gravimetric capacity. This paper deals with analysis of adsorption storage systems adopting the flow through cooling concept. By this approach the feeding hydrogen provides the needed cold to maintain the tank at low temperatures. Two adsorption systems have been examined and modeled adopting the Dubinin-Astakhov model, to see their performance under selected operating conditions. A first case has been analyzed, modeling a storage tank filled with carbon based material (namely MaxSorb®) and comparing the numerical outcomes with the available experimental results for a 2.5 L tank. Under selected operating conditions (minimum inlet hydrogen temperature of approximately 100 K and maximum pressure on the order of 8.5 MPa) and adopting the flow through cooling concept the material shows a gravimetric capacity of about 5.7 %. A second case has been modeled, examining the same tank filled with metal organic framework material (MOF5®) under approximately the same conditions. The model shows that the latter material can achieve a (material) gravimetric capacity on the order of 11%, making the system potentially able to achieve the DOE 2017 target.

08 HYDROGEN↗

Safety Codes and Standards Update (Winter 2019/2020)

The goal of the DOE OE Energy Storage System Safety Roadmap is to foster confidence in the safety and reliability of energy storage systems. There are three interrelated objectives to support the realization of that goal: research, codes and standards (C/S) and communication/coordination. The objective focused on C/S is "To apply research and development to support efforts that refocused on ensuring that codes and standards are available to enable the safe implementation of energy storage systems in a comprehensive, non-discriminatory and science-based manner."

25 ENERGY STORAGE↗

Codes and Standards Update September 2018

The goal of the DOE OE Energy Storage System Safety Roadmap is to foster confidence in the safety and reliability of energy storage systems. There are three interrelated objectives to support the realization of that goal: research, codes and standards (C/S) and communication/coordination. The objective focused on C/S is "To apply research and development to support efforts that refocused on ensuring that codes and standards are available to enable the safe implementation of energy storage systems in a comprehensive, non-discriminatory and science-based manner."

25 ENERGY STORAGE↗