Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

The target asymmetry P_z in {gamma}p-->p{pi}^+{pi}^- with the CLAS spectrometer at Jefferson Laboratory

The study of baryon resonances provides a deeper understanding of the strong interaction because the dynamics and relevant degrees of freedom hidden within them are reflected by the properties of the excited states of baryons. Higher-lying excited states at and above 1.9 GeV/c{sup 2} are generally predicted to have strong couplings to the {pi}{pi}N final states via {pi}{Delta} or {rho}N intermediate states. Double-pion photoproduction is therefore important to find and investigate properties of highmass resonances. The CLAS g9a (FROST) experiment, as part of the N* spectroscopy program at Jefferson Laboratory (JLab), has accumulated photoproduction data using linearly- and circularly-polarized photons incident on a longitudinally-polarized butanol target in the photon energy range 0.3 to 2.4 GeV. In this contribution, the extraction of the target asymmetry for the reaction {gamma}p {yields} p{pi}{sup +}{pi}{sup -} will be described and preliminary results will be presented.

43 PARTICLE ACCELERATORS↗

Investigating the performance of an ion luminescence probe as a multichannel fast-ion energy spectrometer using pulse height analysis

We investigate the capability of a fast-ion luminescent probe to operate as a pulse height ion energy analyzer. An existing high sensitivity system has been reconfigured as a single channel ion detector with an amplifier to give a bandwidth comparable to the phosphor response time. A digital pulse processing method has been developed to determine pulse heights from the detector signal so as to obtain time-resolved information on the ion energy distribution of the plasma ions lost to the wall of the TJ-II stellarator. Finally, the potential of this approach for magnetic confined fusion plasmas is evaluated by studying representative TJ-II discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response function of the magnetic spectrometer PRISMA for the multinucleon transfer reaction {sup 40}Ar+{sup 208}Pb

Multinucleon transfer reaction {sup 40}Ar+{sup 208}Pb has been investigated with the PRISMA-CLARA experimental setup in LNL, INFN, Italy. The experimental differential cross sections have been obtained for different transfer channels by measuring more than {Delta}{theta}{sub lab} = 20 Degree-Sign covered by three angular settings of PRISMA. Results have been compared with the semiclassical calculation GRAZING. Since the understanding of the reaction mechanism depends strongly on the determination of absolute cross section, effect of transport of ions through PRISMA has been studied via a Monte Carlo simulation code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optically detected, single nanoparticle mass spectrometer with pre-filtered electrospray nanoparticle source

An instrument designed for non-destructive mass analysis of single trapped nanoparticles is described. The heart of the instrument is a 3D quadrupole (Paul) trap constructed to give optical access to the trap center along ten directions, allowing passage of lasers for particle heating and detection, particle injection, collection of scattered or fluorescent photons for particle detection and mass analysis, and collection of particles on TEM grids for analysis, as needed. Nanoparticles are injected using an electrospray ionization (ESI) source, and conditions are described for spraying and trapping polymer particles, bare metal particles, and ligand stabilized particles with masses ranging from 200 kDa to >3 GDa. Conditions appropriate to ESI and injection of different types of particles are described. The instrument is equipped with two ion guides separating the ESI source and nanoparticle trap. The first ion guide is mostly to allow desolvation and differential pumping before the particles enter the trap section of the instrument. The second is a linear quadrupole guide, which can be operated in mass selective or mass band-pass modes to limit transmission to species with mass-to-charge ratios in the range of interest. With a little experience, the design allows injection of single particles into the trap upon demand.

36 MATERIALS SCIENCE↗

A highly miniaturized electron and ion energy spectrometer prototype for the rapid analysis of space plasmas

MEMS (Micro Electro-Mechanical Systems) plasma analyzers are a promising possibility for future space missions but conventional instrument designs are not necessarily well suited to micro-fabrication. Here, a candidate design for a MEMS-based instrument has been prototyped using electron-discharge machining. The device features 10 electrostatic analyzers that, with a single voltage applied to it, allow five different energies of electron and five different energies of positive ion to be simultaneously sampled. It has been simulated using SIMION and the electron response characteristics tested in an instrument calibration chamber. Small deviations found in the electrode spacing of the as-built prototype were found to have some effect on the electron response characteristics but do not significantly impede its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A low temperature nonlinear optical rotational anisotropy spectrometer for the determination of crystallographic and electronic symmetries

Nonlinear optical generation from a crystalline material can reveal the symmetries of both its lattice structure and underlying ordered electronic phases and can therefore be exploited as a complementary technique to diffraction based scattering probes. Although this technique has been successfully used to study the lattice and magnetic structures of systems such as semiconductor surfaces, multiferroic crystals, magnetic thin films, and multilayers, challenging technical requirements have prevented its application to the plethora of complex electronic phases found in strongly correlated electron systems. These requirements include an ability to probe small bulk single crystals at the μm length scale, a need for sensitivity to the entire nonlinear optical susceptibility tensor, oblique light incidence reflection geometry, and incident light frequency tunability among others. These measurements are further complicated by the need for extreme sample environments such as ultra low temperatures, high magnetic fields, or high pressures. In this review we present a novel experimental construction using a rotating light scattering plane that meets all the aforementioned requirements. We demonstrate the efficacy of our scheme by making symmetry measurements on a μm scale facet of a small bulk single crystal of Sr{sub 2}IrO{sub 4} using optical second and third harmonic generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fully automated dual-frequency three-pulse-echo 2DIR spectrometer accessing spectral range from 800 to 4000 wavenumbers

A novel dual-frequency two-dimensional infrared instrument is designed and built that permits three-pulse heterodyned echo measurements of any cross-peak within a spectral range from 800 to 4000 cm{sup −1} to be performed in a fully automated fashion. The superior sensitivity of the instrument is achieved by a combination of spectral interferometry, phase cycling, and closed-loop phase stabilization accurate to ∼70 as. The anharmonicity of smaller than 10{sup −4} cm{sup −1} was recorded for strong carbonyl stretching modes using 800 laser shot accumulations. The novel design of the phase stabilization scheme permits tuning polarizations of the mid-infrared (m-IR) pulses, thus supporting measurements of the angles between vibrational transition dipoles. The automatic frequency tuning is achieved by implementing beam direction stabilization schemes for each m-IR beam, providing better than 50 μrad beam stability, and novel scheme for setting the phase-matching geometry for the m-IR beams at the sample. The errors in the cross-peak amplitudes associated with imperfect phase matching conditions and alignment are found to be at the level of 20%. The instrument can be used by non-specialists in ultrafast spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitive fast electron spectrometer in adjustable triode configuration with pulsed tunable laser for research on photo-induced field emission cathodes

We have completed an ultra-high vacuum system for sensitive fast electron spectroscopy from cold cathodes in triode configuration under high electric fields E (<100 MV/m) and pulsed tunable laser illumination (3.5 ns, 10 Hz, hν = 0.5-5.9 eV, and 0.3-17 mJ). The cathodes are prepared and inserted under clean room conditions and can be precisely 3D-positioned, cooled or heated (77-400 K). Commissioning results with the upgraded system are presented. Field emission measurements with a W tip yielded an energy resolution of 14 meV at 4 eV pass energy and a precise determination of the emitter work function, size, and temperature. Photoemission spectroscopy of short electron bunches from a virgin and laser-ablated S-GaP crystal and quantum efficiency measurements revealed surface states, energy relaxation, and band structure effects. In conclusion, this novel system is ready now for the development and characterization of photo-induced field emission cathodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: On the wavelength dependence of the intensity calibration factor of extreme ultraviolet spectrometer determined with profile measurement of bremsstrahlung continuum

The absolute calibration factor of extreme ultraviolet spectroscopic instrument which has recently been determined from absolute radiation profile measurement of bremsstrahlung continuum has been investigated by comparing the calculated diffraction efficiency of grating. An overall tendency of the wavelength dependence of the calibration factor from 40 Å to 500 Å can be reproduced by that of the grating efficiency, especially the agreement between the measured calibration factor and the calculated grating efficiency has been found to be fairly good for the wavelength range 200 Å-500 Å.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A diamond 14 MeV neutron energy spectrometer with high energy resolution

A self-standing single-crystal chemical vapor deposited diamond was obtained using lift-off method. It was fabricated into a radiation detector and response function measurements for 14 MeV neutrons were taken at the fusion neutronics source. 1.5% of high energy resolution was obtained by using the {sup 12}C(n, α){sup 9}Be reaction at an angle of 100° with the deuteron beam line. The intrinsic energy resolution, excluding energy spreading caused by neutron scattering, slowing in the target and circuit noises was 0.79%, which was also the best resolution of the diamond detector ever reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Permeability studies of redox-sensitive nitroxyl spin probes in corn oil using an L-band ESR spectrometer

Electron spin resonance (ESR) studies were carried out for 2mM {sup 14}N labeled {sup 2}H enriched 3-methoxycarbonyl-2,2,5,5-tetramethyl-pyrrolidine-1-oxyl (MC-PROXYL) and 3–carboxy-2,2,5,5,-tetramethyl-1-pyrrolidinyloxy (carboxy-PROXYL) in pure water and various concentrations of corn oil. The ESR parameters, such as the line width, hyperfine coupling constant, g-factor, rotational correlation time, partition parameter and permeability were reported for the samples. The line width broadening was observed for both nitroxyl radicals in corn oil solutions. The partition parameter for permeable MC-PROXYL in corn oil increases with increasing concentration of corn oil, which reveals that the nitroxyl spin probe permeates into the oil phase. From the results, the corn oil concentration was optimized as 50 % for phantom studies. The rotational correlation time also increases with increasing concentration of corn oil. The permeable and impermeable nature of nitroxyl spin probes was demonstrated. These results will be useful for the development of ESR/OMR imaging modalities in in vivo and in vitro studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conception of broadband stigmatic high-resolution spectrometers for the soft X-ray range

We formulate an approach to the development of stigmatic high-resolution spectral instruments for the soft X-ray range (λ ≤ 300 Å), which is based on the combined operation of normalincidence multilayer mirrors (including broadband aperiodic ones) and grazing-incidence reflection gratings with nonequidistant grooves (so-called VLS gratings). A concave multilayer mirror serves to produce a slightly astigmatic image of the radiation source (for instance, an entrance slit), and the diffraction grating produces a set of its dispersed stigmatic spectral images. The width of the operating spectral region is determined by the aperiodic structure of the multilayer mirror and may range up to an octave in wavelength. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

External-cavity diode laser spectrometer for measuring the concentration ratio {sup 13}CO{sub 2}/{sup 12}CO{sub 2} by absorption in the range of 1.6 μm

The method for determining the carbon isotopic ratio from CO{sub 2} absorption spectra in the optical cavity containing atmospheric air with the natural contents of carbon dioxide ∼0.03% is described. The measurements are performed at atmospheric pressure in the conditions of overlapping absorption lines. The measurement accuracy is 0.3‰. (laser applications and other topics in quantum electronics)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flat-field VLS spectrometer for a wavelength range of 50 – 275 Å

A flat-field VLS spectrograph for a wavelength range ∼50 – 275 Å with an average linear dispersion of 0.18 mm Å{sup −1}, which makes use of a grazing-incidence varied line-space (VLS) grating, was calculated and implemented (a spectrograph of Harada class). To fabricate the VLS grating by interference lithography technique, an algorithm was developed for calculating the writing configuration with an auxiliary aberrating mirror (the solution of the inverse problem of interference lithography). The spectrograph was put to a test and line spectra were recorded from the laser-produced plasma of lithium fluoride and teflon targets, which were excited by a focused laser beam (0.5 J, 8 ns, 1.06 μm). A resolving power λ/d l = 800 was demonstrated in a wavelength region of 135 Å. (x-ray spectrometry)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Arecibo pulsar survey using ALFA. IV. Mock spectrometer data analysis, survey sensitivity, and the discovery of 40 pulsars

The on-going Arecibo Pulsar-ALFA (PALFA) survey began in 2004 and is searching for radio pulsars in the Galactic plane at 1.4 GHz. Here we present a comprehensive description of one of its main data reduction pipelines that is based on the PRESTO software and includes new interference-excision algorithms and candidate selection heuristics. This pipeline has been used to discover 40 pulsars, bringing the survey’s discovery total to 144 pulsars. Of the new discoveries, eight are millisecond pulsars (MSPs; P<10 ms) and one is a Fast Radio Burst (FRB). This pipeline has also re-detected 188 previously known pulsars, 60 of them previously discovered by the other PALFA pipelines. We present a novel method for determining the survey sensitivity that accurately takes into account the effects of interference and red noise: we inject synthetic pulsar signals with various parameters into real survey observations and then attempt to recover them with our pipeline. We find that the PALFA survey achieves the sensitivity to MSPs predicted by theoretical models but suffers a degradation for P≳100 ms that gradually becomes up to ∼10 times worse for P>4 s at DM<150 pc cm{sup −3}. We estimate 33 ± 3% of the slower pulsars are missed, largely due to red noise. A population synthesis analysis using the sensitivity limits we measured suggests the PALFA survey should have found 224 ± 16 un-recycled pulsars in the data set analyzed, in agreement with the 241 actually detected. The reduced sensitivity could have implications on estimates of the number of long-period pulsars in the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗