Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Influence of Coulomb effects on the resolving power of multireflection mass-spectrometer systems

General theoretical approaches to the modelling of Coulomb effects in short ion bunches, developed previously by the authors, are applied in this paper to the calculation of multireflection mass-spectrometer systems. A separate module of the MASIM 3D applied software package is designed. An adaptive computational procedure for calculating the 'mirror potential' induced by an ion bunch on the surface of field-forming electrodes is proposed. The dynamics of ion bunches in a time-of-flight reflectron-type mass analyser is calculated and the limitations on the resolving power, caused by resonant Coulomb effects of self-bunching and coalescence in the groups of particles with close masses, are revealed on the basis of numerical experiments. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accounting for the instrument function of crystal spectrometers operating in many reflection orders in the diagnostics of laser plasma from its continuum spectrum

By the example of an X-ray spectrometer with a spherically bent mica crystal we consider the diagnostic errors entailed when the observed bremsstrahlung spectrum is attributed to a single spectrum of reflection. As an illustration we choose the X-ray emission spectrum of the plasma produced at the surface of a steel foil by femtosecond laser pulses of relativistic intensity. It is shown that obtaining adequate results in the case of a high-temperature plasma calls for the consistent inclusion of all orders of reflection or diffraction with a dispersing device. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Versitile X-ray diagnostics of laser-produced high-temperature plasmas using an ultra-high luminosity spectrometer

Versitile diagnostics of high-temperature magnesium laser-produced plasmas is performed using an ultra-high luminosity X-ray focusing crystal spectrometer. The plasmas are produced by focusing nanosecond laser pulses (0.53 μm, 1 J, 2 ns) on a massive magnesium target. The absolute intensities and X-ray yields are measured for the resonance lines of H- and He-like ions (spectral range: Δλ = 8 –10 Å), the electron temperature of plasmas is determined (range: T{sub e} = 200 – 550 eV), and the behaviour of these parameters is established in a broad range of laser pulse energy E{sub L} (10 mJ – 1 J). This approach permits the parameters of laser-plasma radiation sources to be monitored in real time in a wide intensity range (difference in intensity: over 10{sup 4}) and in a broad range of plasma parameters. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Introduction, Investigation, and Experimental Validation of a Novel Passive Neutron Spectrometer

Unfolding neutron energy spectra are instrumental for determining personal health effects and calculating dose received. This area of study is heavily researched, and Lawrence Livermore National Laboratory (LLNL) is investigating a passive neutron spectrometer for the purpose of acquiring the information needed to determine personnel dose in the event of a criticality accident. A part of this investigation is presented in this article through the examination of four experimental detector responses (DRs). These four DRs were acquired in the presence of 252 Cf, AmBe, GODIVA, and National Ignition Facility (NIF) neutron sources. An algorithm developed at LLNL was used to unfold the neutron fluence from each of the four DRs, and subsequently, fluence-to-dose conversion factors provided by the American National Standards Institute were used to calculate dose. Additionally, a multistep unfolding process was developed and employed to calculate the effects of both direct (from the source) and indirect (from room return) neutrons. The average error when unfolding the direct DR was less than 8%. The dose from 252 Cf was predicted with only 8% error. The multistep approach allowed for the identification of the low-energy neutrons in the 252 Cf, AmBe, and NIF DRs.

Nuclear Criticality Safety Program (NCSP)↗

CLOUD AND HAZE IN THE WINTER POLAR REGION OF TITAN OBSERVED WITH VISUAL AND INFRARED MAPPING SPECTROMETER ON BOARD CASSINI

A large cloud in the north polar region of Titan was first observed by the Visual and Infrared Mapping Spectrometer (VIMS) in 2005 and then in 2006. This cloud, confined beyond the latitude 62 Degree-Sign N, is surrounded by a mixture of aerosol and mist probably lying in the low stratosphere and troposphere. Subsequent images of this region of Titan show a gradual vanishing of this cloud which was reported previously. In this paper, we characterize the physical properties of this cloud, haze, and mist as well as their time evolutions. We note several details on the images such as a secondary cloud above the main cloud and latitudes beyond 70 Degree-Sign N. We also show that the cloud disappearance leaves the polar region poorly loaded in aerosols, yielding an annular zone of aerosols between 50 Degree-Sign N and 65 Degree-Sign N. Our analysis suggests that this structure observed by VIMS in the near-IR is an annular structure observed by ISS on board Voyager one Titan year ago in 1980.

79 ASTRONOMY AND ASTROPHYSICS↗

CHROMOSPHERIC EVAPORATION IN SOLAR FLARE LOOP STRANDS OBSERVED WITH THE EXTREME-ULTRAVIOLET IMAGING SPECTROMETER ON BOARD HINODE

The entire profile of the Fe XXIII line at 263.8 A, formed at temperature Almost-Equal-To 14 MK, was blueshifted by an upward velocity -122 {+-} 33 km s{sup -1} when it was first detected by the Extreme-ultraviolet Imaging Spectrometer operating in rapid cadence (11.18 s) stare mode during a C1 solar flare. The entire profile became even more blueshifted over the next two exposures, when the upward velocity reached its maximum of -208 {+-} 14 km s{sup -1} before decreasing to zero over the next 12 exposures. After that, a weak, secondary blueshifted component appeared for five exposures, reached a maximum upward velocity of -206 {+-} 33 km s{sup -1}, and disappeared after the maximum line intensity (stationary plus blueshifted) was achieved. Velocities were measured relative to the intense stationary profile observed near the flare's peak and early during its decline. The initial episode during which the entire profile was blueshifted lasted about 156 s, while the following episode during which a secondary blueshifted component was detected lasted about 56 s. The first episode likely corresponds to chromospheric evaporation in a single loop strand, while the second corresponds to evaporation in an additional strand, as described in multi-strand flare loop models proposed by Hori et al. and Warren and Doschek. Line emission from progressively cooler ions (Fe XVII, XVI, and XIV) brightened at successively later times, consistent with cooling of flare-heated plasma.

79 ASTRONOMY AND ASTROPHYSICS↗

CHROMOSPHERIC EVAPORATION IN AN M1.8 FLARE OBSERVED BY THE EXTREME-ULTRAVIOLET IMAGING SPECTROMETER ON HINODE

We discuss observations of chromospheric evaporation for a complex flare that occurred on 2012 March 9 near 03:30 UT obtained from the Extreme-ultraviolet Imaging Spectrometer (EIS) on board the Hinode spacecraft. This was a multiple event with a strong energy input that reached the M1.8 class when observed by EIS. EIS was in raster mode and fortunately the slit was almost at the exact location of a significant energy input. Also, EIS obtained a full-CCD spectrum of the flare, i.e., the entire CCD was readout so that data were obtained for about the 500 lines identified in the EIS wavelength ranges. Chromospheric evaporation characterized by 150-200 km s{sup -1} upflows was observed in multiple locations in multi-million degree spectral lines of flare ions such as Fe XXII, Fe XXIII, and Fe XXIV, with simultaneous 20-60 km s{sup -1} upflows in million degree coronal lines from ions such as Fe XII-Fe XVI. The behavior of cooler, transition region ions such as O VI, Fe VIII, He II, and Fe X is more complex, but upflows were also observed in Fe VIII and Fe X lines. At a point close to strong energy input in space and time, the flare ions Fe XXII, Fe XXIII, and Fe XXIV reveal an isothermal source with a temperature close to 14 MK and no strong blueshifted components. At this location there is a strong downflow in cooler active region lines from ions such as Fe XIII and Fe XIV, on the order of 200 km s{sup -1}. We speculate that this downflow may be evidence of the downward shock produced by reconnection in the current sheet seen in MHD simulations. A sunquake also occurred near this location. Electron densities were obtained from density sensitive lines ratios from Fe XIII and Fe XIV. Atmospheric Imaging Assembly (AIA) observations from the Solar Dynamics Observatory are used with JHelioviewer to obtain a qualitative overview of the flare. However, AIA data are not presented in this paper. In summary, spectroscopic data from EIS are presented that can be used for predictive tests of models of chromospheric evaporation as envisaged in the Standard Flare Model.

79 ASTRONOMY AND ASTROPHYSICS↗

DYNAMICS OF X-RAY-EMITTING EJECTA IN THE OXYGEN-RICH SUPERNOVA REMNANT PUPPIS A REVEALED BY THE XMM-NEWTON REFLECTION GRATING SPECTROMETER

Using the unprecedented spectral resolution of the reflection grating spectrometer (RGS) on board XMM-Newton, we reveal dynamics of X-ray-emitting ejecta in the oxygen-rich supernova remnant Puppis A. The RGS spectrum shows prominent K-shell lines, including O VII He{alpha} forbidden and resonance, O VIII Ly{alpha}, O VIII Ly{beta}, and Ne IX He{alpha} resonance, from an ejecta knot positionally coincident with an optical oxygen-rich filament (the so-called {Omega} filament) in the northeast of the remnant. We find that the line centroids are blueshifted by 1480 {+-} 140 {+-} 60 km s{sup -1} (the first and second term errors are measurement and calibration uncertainties, respectively), which is fully consistent with that of the optical {Omega} filament. Line broadening at 654 eV (corresponding to O VIII Ly{alpha}) is obtained to be {sigma} {approx}< 0.9 eV, indicating an oxygen temperature of {approx}< 30 keV. Analysis of XMM-Newton MOS spectra shows an electron temperature of {approx}0.8 keV and an ionization timescale of {approx}2 Multiplication-Sign 10{sup 10} cm{sup -3} s. We show that the oxygen and electron temperatures as well as the ionization timescale can be reconciled if the ejecta knot was heated by a collisionless shock whose velocity is {approx}600-1200 km s{sup -1} and was subsequently equilibrated due to Coulomb interactions. The RGS spectrum also shows relatively weak K-shell lines of another ejecta feature located near the northeastern edge of the remnant, from which we measure redward Doppler velocities of 650 {+-} 70 {+-} 60 km s{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of extreme ultraviolet imaging spectrometer observations of solar coronal loops with Alfvén wave turbulence models

The observed non-thermal widths of coronal emission lines could be due to Alfvén wave turbulence. To test this idea, we examine and analyze the dynamics of an active region observed on 2012 September 7. We use spectral line profiles of Fe XII, Fe XIII, Fe XV, and Fe XVI obtained by the Extreme-ultraviolet Imaging Spectrometer on the it Hinode spacecraft. The observations show non-thermal velocities, Doppler outflows, and intensities for loops in this active region. The observed non-thermal velocities are compared with predictions from models for Alfvén wave turbulence in the observed coronal loops. This modeling takes into account the relationship between the width of the coronal emission lines and the orientation of the coronal loops with respect to the line-of-sight direction. We find that in order to produce the observed line widths we need to introduce a random parallel-flow component in addition to the perpendicular velocity due to Alfvén waves. The observed widths are consistent with photospheric footpoint velocities in the range 0.3-1.5 km s{sup –1}. We conclude that the Alfvén wave turbulence model is a strong candidate for explaining how the observed loops are heated.

79 ASTRONOMY AND ASTROPHYSICS↗

THE COSMIC INFRARED BACKGROUND EXPERIMENT (CIBER): THE LOW RESOLUTION SPECTROMETER

Absolute spectrophotometric measurements of diffuse radiation at 1 {mu}m to 2 {mu}m are crucial to our understanding of the radiative content of the universe from nucleosynthesis since the epoch of reionization, the composition and structure of the zodiacal dust cloud in our solar system, and the diffuse galactic light arising from starlight scattered by interstellar dust. The Low Resolution Spectrometer (LRS) on the rocket-borne Cosmic Infrared Background Experiment is a {lambda}/{Delta}{lambda} {approx} 15-30 absolute spectrophotometer designed to make precision measurements of the absolute near-infrared sky brightness between 0.75 {mu}m <{lambda} < 2.1 {mu}m. This paper presents the optical, mechanical, and electronic design of the LRS, as well as the ground testing, characterization, and calibration measurements undertaken before flight to verify its performance. The LRS is shown to work to specifications, achieving the necessary optical and sensitivity performance. We describe our understanding and control of sources of systematic error for absolute photometry of the near-infrared extragalactic background light.

79 ASTRONOMY AND ASTROPHYSICS↗

THE ABSOLUTE CALIBRATION OF THE EUV IMAGING SPECTROMETER ON HINODE

We investigate the absolute calibration of the EUV Imaging Spectrometer (EIS) on Hinode by comparing EIS full-disk mosaics with irradiance observations from the EUV Variability Experiment on the Solar Dynamics Observatory. We also use extended observations of the quiet corona above the limb combined with a simple differential emission measure model to establish new effective area curves that incorporate information from the most recent atomic physics calculations. We find that changes to the EIS instrument sensitivity are a complex function of both time and wavelength. We find that the sensitivity is decaying exponentially with time and that the decay constants vary with wavelength. The EIS short wavelength channel shows significantly longer decay times than the long wavelength channel.

79 ASTRONOMY AND ASTROPHYSICS↗

SYSTEMATIC EFFECTS IN POLARIZING FOURIER TRANSFORM SPECTROMETERS FOR COSMIC MICROWAVE BACKGROUND OBSERVATIONS

The detection of the primordial B-mode polarization signal of the cosmic microwave background (CMB) would provide evidence for inflation. Yet as has become increasingly clear, the detection of a such a faint signal requires an instrument with both wide frequency coverage to reject foregrounds and excellent control over instrumental systematic effects. Using a polarizing Fourier transform spectrometer (FTS) for CMB observations meets both of these requirements. In this work, we present an analysis of instrumental systematic effects in polarizing FTSs, using the Primordial Inflation Explorer (PIXIE) as a worked example. We analytically solve for the most important systematic effects inherent to the FTS—emissive optical components, misaligned optical components, sampling and phase errors, and spin synchronous effects—and demonstrate that residual systematic error terms after corrections will all be at the sub-nK level, well below the predicted 100 nK B-mode signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Impurity transport studies at Wendelstein 7-X by means of x-ray imaging spectrometer measurements

This study reports on the effect of on- and off-axis heating power deposition on the impurity confinement in purely electron cyclotron resonance heated He plasmas on the stellarator Wendelstein 7-X. Therefore, impurity transport times τ I have been determined after Fe impurity injections by laser ablations and monitoring the temporal impurity emissivities by the x-ray imaging spectrometer HR-XIS. A significant increase of τ I has been observed when changing the power deposition from on- to off-axis heating with energy confinement times τ E being mainly unaffected. In addition, the scaling of impurity transport properties with respect to a variation of heating power P ECRH and electron density n e has been investigated by keeping the heating power deposition on-axis. The observed τ I scaling compares well to known τ I scaling laws observed in other machines. A comparison of τ I and τ E yields an averaged ratio of τ E /τ I = 1.3 and transport times in the range of τ I = 40–130 ms and τ E = 40–190 ms. Comparing those absolute values to neoclassical predictions supports the recently observed nature of anomalous transport in Wendelstein 7-X, given within the up to now investigated operational parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of Pfirsch–Schlüter parallel flow in x-ray imaging crystal spectrometer inversion analysis

The x-ray imaging crystal spectrometer (XICS) tomographic inversion code for Wendelstein 7-X (W7-X) has been modified to consider the effects of parallel flows and has been applied to analyze measurements taken during recent experimental campaigns. Previous analysis neglected the effects of parallel flows due to the primarily perpendicular geometry of the sightlines and the small magnitude predicted by neoclassical theory. To reconsider these effects, the incompressibility condition for plasma flows is used to calculate the parallel Pfirsch–Schlüter flow component for the equilibrium configuration. By incorporating this condition along with the geometry of the sightlines—i.e. the fractional contributions of perpendicular and parallel flows—, an updated expression for the measured flow is used for the profile inversion. Application of this modified inversion code to data from W7-X shows that the magnitude of the radial electric field and the flux surface averaged perpendicular flow are reduced by approximately a factor of 2 and brought into better agreement with neoclassical predictions and charge exchange recombination spectroscopy measurements.

Pfirsch–Schlüter flows↗

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

DETECTION OF WIDESPREAD HYDRATED MATERIALS ON VESTA BY THE VIR IMAGING SPECTROMETER ON BOARD THE DAWN MISSION

Water plays a key role in the evolution of terrestrial planets, and notably in the occurrence of Earth's oceans. However, the mechanism by which water has been incorporated into these bodies-including Earth-is still extensively debated. Here we report the detection of widespread 2.8 {mu}m OH absorption bands on the surface of the asteroid Vesta by the VIR imaging spectrometer on board Dawn. These observations are surprising as Vesta is fully differentiated with a basaltic surface. The 2.8 {mu}m OH absorption is distributed across Vesta's surface and shows areas enriched and depleted in hydrated materials. The uneven distribution of hydrated mineral phases is unexpected and indicates ancient processes that differ from those believed to be responsible for OH on other airless bodies, like the Moon. The origin of Vestan OH provides new insight into the delivery of hydrous materials in the main belt and may offer new scenarios on the delivery of hydrous minerals in the inner solar system, suggesting processes that may have played a role in the formation of terrestrial planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of β -decay feeding patterns of 88 Rb and 88 Kr using the Modular Total Absorption Spectrometer at ORNL HRIBF

We report precise determination of ground-state feeding in the β decay of fission products is an important but challenging component in modeling reactor antineutrino flux and reactor decay heat. The Modular Total Absorption Spectrometer (MTAS) is a versatile NaI(Tl) detector array that determines the true β-decay pattern free from the pandemonium effect, including precise ground-state feeding intensities. In this paper, we report MTAS results of the β feeding intensities of 88 Rb and 88 Kr, fission products with large cumulative yields in nuclear reactors. By comparing MTAS results with previous measurements, 88 Rb provides a validation of MTAS's ability to determine ground-state feedings in β decays, while the precision of 88 Kr ground-state feeding is improved when compared with the Evaluated Nuclear Structure Data File (ENSDF). The investigation of sources that contribute to β feeding branching uncertainties in MTAS experiments is discussed in detail. Lastly, the deconvolution of 88 Rb decay spectra suggests that MTAS can distinguish an allowed β spectral shape from a first forbidden unique β spectral shape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor

A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a {sup 6}Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of 10{sup 8} n/cm{sup 2}s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of 10{sup 6} n/cm{sup 2}s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10{sup 9} n/cm{sup 2}s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗