Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE RING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Search for Lepton Flavour Violating Decays τ → l K 0 s with the BABAR Detector

We present the search for the lepton flavour violating decay τ→ lK 0 s with the BaBar experiment data. This process and many other lepton flavour violating τ decays, like τ→ μγ and τ→ lll, are one of the most promising channel to search for evidence of new physics. According to the Standard Model and the neutrino mixing parameters, branching fractions are estimated well below 10 -14 , but many models of new physics allow for branching fractions values close to the present experimental sensitivity. This analysis is based on a data sample of 469fb -1 collected by BABAR detector at the PEP-II storage ring from 1999 to 2007, equivalent to 431 millions of τ pairs. the BABAR experiment, initially designed for studying CP violation in B mesons, has demonstrated to be one of the most suitable environments for studying τ decays. The tracking system, the calorimeter and the particle identification of BABAR, together with the knowledge of the τ initial energy, allow an extremely powerful rejection of background events that, for this analysis, is better than 10 -9 . Being τ→lK 0 s a decay mode without neutrinos, the signal τ decay can be fully reconstructed. Kinematical constraints are used in a fit that provides a decay tree reconstruction with a high resolution. For this analysis MC simulated events play a decisive role for estimating the signal efficiency and study the residual background. High statistics MC sample are produced simulating detector conditions for different periods of data collection, in order to reduce any discrepancies with the data. When discrepancies can not be removed, we perform studies to compute a correction factor or an estimation of systematic errors that need to be included in the final measurement. A significant improvement of the current result can be reached only with a higher statistics and, therefore, with a new collider providing a luminosity from 10 to 100 times more than PEP-II. A new detector, with improved performance and able to collect data in a high background environment, is also requested to fully exploit the capability of such amount of data. In fact, only keeping the efficiency and the background as similar as possible to present ones, we will be able to scale almost linearly the estimated upper limit according to the luminosity. The strong potential of improvement for the search of lepton flavour violation τ decays makes the building of such a machine highly desirable.

43 PARTICLE ACCELERATORS↗

ELECTRON-ION RECOMBINATION OF Fe XII FORMING Fe XI: LABORATORY MEASUREMENTS AND THEORETICAL CALCULATIONS

We have measured electron-ion recombination for Fe XII forming Fe XI using a merged-beam configuration at the heavy-ion storage ring TSR located at the Max Planck Institute for Nuclear Physics in Heidelberg, Germany. The measured merged-beam recombination rate coefficient (MBRRC) for collision energies from 0 to 1500 eV is presented. This work uses a new method for determining the absolute MBRRC based on a comparison of the ion beam decay rate with and without the electron beam on. For energies below 75 eV, the spectrum is dominated by dielectronic recombination (DR) resonances associated with 3s {yields} 3p and 3p {yields} 3d core excitations. At higher energies, we observe contributions from 3 {yields} N' and 2 {yields} N' core excitation DR. We compare our experimental results to state-of-the-art multi-configuration Breit-Pauli (MCBP) calculations and find significant differences, both in resonance energies and strengths. We have extracted the DR contributions from the measured MBRRC data and transformed them into a plasma recombination rate coefficient (PRRC) for temperatures in the range of 10{sup 3}-10{sup 7} K. We show that the previously recommended DR data for Fe XII significantly underestimate the PRRC at temperatures relevant for both photoionized plasmas (PPs) and collisionally ionized plasmas (CPs). This is contrasted with our MCBP PRRC results, which agree with the experiment to within 30% at PP temperatures and even better at CP temperatures. We find this agreement despite the disagreement shown by the detailed comparison between our MCBP and experimental MBRRC results. Last, we present a simple parameterized form of the experimentally derived PRRC for easy use in astrophysical modeling codes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tracking Study for Top-off Safety Validation at SSRL

A tracking study was performed at SSRL to identify necessary controls and to prove the safety of top-off operation from radiation hazard under such conditions. The safety rationale, tracking setup and the results are presented. Top-off operational mode has become a trend for existing and planned third-generation storage ring light sources for the many benefits such as increased average brightness, improved thermal stability and elimination of the interruption to user experiments due to traditional injection [1, 2]. Unlike the traditional decay mode injection which happens a few times a day and during which the photon beamline shutters are closed, top-off mode injection requires photon beamline shutters to remain open during injection and occurs much more frequently, from once every 5 seconds to once every 30 minutes. Therefore injection may be transparent to user experiments and the stored current variation can be significantly reduced. For a facility equipped with a full-energy injector, the biggest challenge to the implementation of the top-off mode may be the control of radiation hazard. Studies at ALS and SSRL [2, 3] have shown that a single injected electron pulse that enters the photon beamline and exits the radiation shield wall would cause unacceptable radiation doses on the experimental floor. For the protection of users and experimental equipment, it is hence a prerequisite for top-off operation to establish controls that absolutely prevent such occurrences. Similar to other facilities such as ALS and APS [2, 4], tracking simulations were conducted at SSRL to identify the control measures, define the specifications and prove the radiation safety. However, a different approach toward the proof of safety is taken at SSRL. In this paper we first describe the SSRL accelerator complex with emphasis on the aspects related to top-off in section 2. The general considerations and requirements for top-off are presented in section 3. Section 4 and 5 give a detailed description of the tracking setup and results. Concluding remarks are given in section 6.

43 PARTICLE ACCELERATORS↗

Dalitz plot analysis of D{sub s}{sup +}{yields}{pi}{sup +}{pi}{sup -}{pi}{sup +}

A Dalitz plot analysis of approximately 13 000 D{sub s}{sup +} decays to {pi}{sup +}{pi}{sup -}{pi}{sup +} has been performed. The analysis uses a 384 fb{sup -1} data sample recorded by the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} storage ring running at center of mass energies near 10.6 GeV. Amplitudes and phases of the intermediate resonances which contribute to this final state are measured. A high precision measurement of the ratio of branching fractions is performed: B(D{sub s}{sup +}{yields}{pi}{sup +}{pi}{sup -}{pi}{sup +})/B(D{sub s}{sup +}{yields}K{sup +}K{sup -}{pi}{sup +})=0.199{+-}0.004{+-}0.009. Using a model-independent partial wave analysis, the amplitude and phase of the S wave have been measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurements of Tau Lepton Decays

Using data collected with the BABAR detector at the SLAC PEP-II electron-positron storage ring operating at a centre-of-mass energy near 10.58 GeV, the branching fractions B(τ - → π - π - π + ντ) =(8.83±0.01±0.13)%, B(τ - → K - π - π + ντ) =(0.273± 0.002 ± 0.009)%, B(τ - → K - π - K+ντ) =(0.1346 ± 0.0010 ± 0.0036)%, and B(τ - → K - K - K+ντ) =(1.58 ± 0.13 ± 0.12) × 10 -5 are measured where the uncertainties are statistical and systematic, respectively. The invariant mass distribution for the τ - → π - π - π+ντ , τ - → K - π - π+ντ , τ - → K - π - K+ντ and τ - → K - K - K+ντ decays are unfolded to correct for detector effects. A measurement of B(τ - → φπ - ντ ) =(3.42±0.55±0.25)×10 -5 , a measurement of B(τ - → φK - ντ) =(3.39±0.20±0.28)× 10 -5 and an upper limit on B(τ - → K - K - K+ντ [ex.φ]) ≤ 2.5 × 10 -6 @90%CL are determined from a binned maximum likelihood fit of the τ - → K - π - K+ντ and τ - → K - K - K+ντ K+K - invariant mass distributions. The branching ratio B(τ - →K - ν τ )/ B(τ - →π - ν τ ) is measured to be (6.531±0.056±0.093)×10 -2 from which |Vus| is determined to be 0.2255 ± 0.0023. The branching ratio B(τ - →μ - ν τ $\bar{v}$ μ )/ B(τ - →e - ν τ $\bar{v}$ e ) =(9.796 ± 0.016 ± 0.035) × 10 -1 is measured enabling a precision test of the Standard Model assumption of charged current lepton universality, gμ ge =1.0036 ± 0.0020. The branching ratios B(τ - →K - ν τ ) /B(τ - →e - ν τ $\bar{v}$ e ) =(3.882 ± 0.032 ± 0.057) × 10 -2 , and B(τ - →π - ντ ) /B(τ - →e - ν τ $\bar{v}$ e ) =(5.945 ± 0.014 ± 0.061) × 10 -1 are measured which provide additional tests of charged current lepton universality, g τ /g μ π = 0.9856 ± 0.0057 and g τ /g μ K = 0.9827 ± 0.0086 which can be combined to give g τ /g μ π/K = 0.9850 ± 0.0054 . Any deviation of these measurements from the expected Standard Model values would be an indication of new physics.

43 PARTICLE ACCELERATORS↗

Trapping of Electron Cloud LLC/Cesrta Quadrupole and Sextupole Magnets

The Cornell Electron Storage Ring (CESR) has been reconfigured as an ultra low emittance damping ring for use as a test accelerator (CesrTA) for International Linear Collider (ILC) damping ring R&D [1]. One of the primary goals of the CesrTA program is to investigate the interaction of the electron cloud with low emittance positron beam to explore methods to suppress the electron cloud, develop suitable advanced instrumentation required for these experimental studies and benchmark predictions by simulation codes. This paper reports the simulation of the electron-cloud formation in CESRTA and ILC quadrupole and sextupole magnets using the 3D code CLOUDLAND. We found that electrons can be trapped with a long lifetime in a quadrupole and sextupole magnet due to the mirror field trapping mechanism. We study the effects of magnet strength, bunch current, ante-chamber effect, bunch spacing effect and secondary emission yield (SEY) in great detail. The development of an electron cloud in magnets is the main concern where a weak solenoid field is not effective. Quadrupole and sextupole magnets have mirror field configurations which may trap electrons by the mirror field trapping mechanism [2]. Fig.1 shows the orbit of a trapped electron in a quadrupole magnet. The electron makes gyration motion (called transverse motion) and also moves along the field line (called longitudinal motion). At the mirror point (middle of the field line), there is a maximum longitudinal energy and minimum transverse energy. When the electron moves away from the mirror point, its longitudinal energy reduces and the transverse energy increases as the magnetic field increases. If the magnetic field is strong enough, the longitudinal energy becomes zero at one point and then the electron is turned back by the strong field. Note that the electrons are trapped in the region near the middle of the field lines. Although all quadrupole and sextupole magnets can trap electrons in principle, the trapping mechanism is also greatly sensitive to the detail dynamics of the electrons [3]. Both the positron beam and the spacing charge force of electron cloud itself play important roles. This paper reports the simulation of electron cloud in CESRTA/ILC quadrupole and sextupole magnets. Table 1 shows the main parameters used in the simulation.

43 PARTICLE ACCELERATORS↗

Laser-Compton Gamma-Ray Source at a Beamline (BL1) in NewSUBARU

We have developed a laser-Compton gamma-ray source at beamline (BL1) in NewSUBARU, an electron storage ring operating at electron energies of 0.7-1.5 GeV. Initially, we generated 17-37 MeV gamma rays using a Nd:YVO{sub 4} laser operating at 1.06 {mu}m and 0.53 {mu}m, achieving a luminosity of 6000 photons/(W{center_dot}mA{center_dot}s) and a flux of 5x10{sup 6} photons/s with a laser power of 4 W and a beam current of 200 mA. We then installed a CO{sub 2} laser operating at 10.6 {mu}m, and generated gamma rays in the energy range of 1-4 MeV. In this range, the gamma-ray luminosity is 7300 photons/(W{center_dot}mA{center_dot}s) and the flux is 5.6x10{sup 6} photons/s when operating the laser at 4 W and 200 mA. These performances are in good agreement with calculations. We will next add a Tm-fiber laser operating at 2 {mu}m to generate gamma rays in the energy range of 4-21 MeV, using a laser-focusing design to generate the maximum flux. The luminosity of this stage is calculated to be 6400 photons/(W{center_dot}mA{center_dot}s). Nd:YVO{sub 4}, CO{sub 2}, and Tm-fiber laser are all capable of operating in a high-power regime and can generate kW-level output power. At present, the maximum gamma-ray flux is limited only by the laser power. When operating the laser at 1 kW of output power with a beam current of 200 mA, we expect a flux of up to {approx}10{sup 9} photons/s. At NewSUBARU, up to several dozen MeV gamma-ray sources are capable of generating such high power.

43 PARTICLE ACCELERATORS↗

Ion colliders

Ion colliders are research tools for high-energy nuclear physics, and are used to test the theory of Quantum Chromo Dynamics (QCD). The collisions of fully stripped high-energy ions create matter of a temperature and density that existed only microseconds after the Big Bang. Ion colliders can reach higher densities and temperatures than fixed target experiments although at a much lower luminosity. The first ion collider was the CERN Intersecting Storage Ring (ISR), which collided light ions [77Asb1, 81Bou1]. The BNL Relativistic Heavy Ion Collider (RHIC) is in operation since 2000 and has collided a number of species at numerous energies. The CERN Large Hadron Collider (LHC) started the heavy ion program in 2010. Table 1 shows all previous and the currently planned running modes for ISR, RHIC, and LHC. All three machines also collide protons, which are spin-polarized in RHIC. Ion colliders differ from proton or antiproton colliders in a number of ways: the preparation of the ions in the source and the pre-injector chain is limited by other effects than for protons; frequent changes in the collision energy and particle species, including asymmetric species, are typical; and the interaction of ions with each other and accelerator components is different from protons, which has implications for collision products, collimation, the beam dump, and intercepting instrumentation devices such a profile monitors. In the preparation for the collider use the charge state Z of the ions is successively increased to minimize the effects of space charge, intrabeam scattering (IBS), charge change effects (electron capture and stripping), and ion-impact desorption after beam loss. Low charge states reduce space charge, intrabeam scattering, and electron capture effects. High charge states reduce electron stripping, and make bending and acceleration more effective. Electron stripping at higher energies is generally more efficient. Table 2 shows the charge states and energies in the RHIC and LHC injector chains for the heaviest ion species used to date. The RHIC pulsed sputter source (PSC) and Tandem electrostatic accelerator are being replaced by an Electron Beam Ion Source (EBIS), Radio Frequency Quadrupole (RFQ) and short linac [08Ale1]. With EBIS beams of any element can be prepared for RHIC including uranium and spin-polarized 3He. At CERN an ECR ion source is used, followed by an RFQ and Linac. The ions are then accumulated, electron cooled, and accelerated in LEIR. After transfer to and acceleration in the PS, ion beams are injected into the SPS.

43 PARTICLE ACCELERATORS↗

Dose calculations using MARS for Bremsstrahlung beam stops and collimators in APS beamline stations.

The Monte Carlo radiation transport code MARS is used to model the generation of gas bremsstrahlung (GB) radiation from 7-GeV electrons which scatter from residual gas atoms in undulator straight sections within the Advanced Photon Source (APS) storage ring. Additionally, MARS is employed to model the interactions of the GB radiation with components along the x-ray beamlines and then determine the expected radiation dose-rates that result. In this manner, MARS can be used to assess the adequacy of existing shielding or the specifications for new shielding when required. The GB radiation generated in the 'thin-target' of an ID straight section will consist only of photons in a 1/E-distribution up to the full energy of the stored electron beam. Using this analytical model, the predicted GB power for a typical APS 15.38-m insertion device (ID) straight section is 4.59 x 10{sup -7} W/nTorr/mA, assuming a background gas composed of air (Z{sub eff} = 7.31) at room temperature (293K). The total GB power provides a useful benchmark for comparisons between analytical and numerical approaches. We find good agreement between MARS and analytical estimates for total GB power. The extended straight section 'target' creates a radial profile of GB, which is highly peaked centered on the electron beam. The GB distribution reflects the size of the electron beam that creates the radiation. Optimizing the performance of MARS in terms of CPU time per incident trajectory requires the use of a relatively short, high-density gas target (air); in this report, the target density is {rho}L = 2.89 x 10{sup -2} g/cm{sup 2} over a length of 24 cm. MARS results are compared with the contact dose levels reported in TB-20, which used EGS4 for radiation transport simulations. Maximum dose-rates in 1 cc of tissue phantom form the initial basis for comparison. MARS and EGS4 results are approximately the same for maximum 1-cc dose-rates and attenuation in the photon-dominated regions; for thicker targets, however, the dose-rate no longer depends only on photon attenuation, as photoneutrons (PNs) begin to dominate. The GB radiation-induced photoneutron measurements from four different metals (Fe, Cu, W, and Pb) are compared with MARS predictions. The simulated dose-rates for beamline 6-ID are approximately 3-5 times larger than the measured values, whereas those for beamline 11-ID are much closer. Given the uncertainty in local values of pressure and Z, the degree of agreement between MARS and the PN measurements is good. MARS simulations of GB-induced radiation in and around the FOE show the importance of using actual pressure and gas composition (Z{sub eff}) to obtain accurate PN dose. For a beam current of 300 mA, extrapolating pressure data measured in previously published studies predicts an average background gas pressure of 27 nTorr. An average atomic number of Z{sub eff} = 4.0 is obtained from the same studies. In addition, models of copper masks presently in use at the APS are included. Simulations show that inclusion of exit masks make significant differences in both the radiation spatial distribution within the FOE, as well as the peak intensity. Two studies have been conducted with MARS to assess shielding requirements. First, dose levels in contact with the outside wall of the FOE are examined when GB radiation strikes Pb or W beam stops of varying transverse size within the FOE. Four separate phantom regions are utilized to measure the dose, two at beam elevation and two at the horizontal beam position. The first two phantoms are used for scoring FOE dose along the outside and back walls, horizontally; the second two collect dose on the roof and vertically on the back wall. In all cases, the beam stop depth is maintained at 30 cm. Inclusion of front end (FE) exit masks typically cause a 1-2 order-of-magnitude increase in the dose-rates relative to the case with no masks. Masks place secondary bremsstrahlung sources inside the FOE, and therefore they must be shielded appropriately. The MARS model does not fully account for all shielding present in the hutches; localized shielding is employed in individual hutches. Typically, a collimator, placed downstream of the FE exit masks, mitigates the possible increase in dose. Regarding beam stop transverse size, a modest reduction in dose on the back wall is noted as the stop dimension (square cross section) is increased from 12 cm to 24 cm. In the second study, the thickness of Pb required to shield against the GB extremal ray is determined. In this study, we are interested in finding the thickness of material necessary to add at the edge of a stop to adequately block GB radiation; therefore, we look at the case of no masks in order to have a well-defined GB beam edge. Simulations show the separation between the extremal ray and the edge of the shielding should be 2R{sub m}, where R{sub m} is the Moliere radius.

43 PARTICLE ACCELERATORS↗

Feasibility study of high-resolution coherent diffraction microscopy using synchrotron x rays focused by Kirkpatrick-Baez mirrors

High-flux coherent x rays are necessary for the improvement of the spatial resolution in coherent x-ray diffraction microscopy (CXDM). In this study, high-resolution CXDM using Kirkpatrick-Baez (KB) mirrors is proposed, and the mirrors are designed for experiments of the transmission scheme at SPring-8. Both the photon density and spatial coherence of synchrotron x rays focused by the KB mirrors are investigated by wave optical simulation. The KB mirrors can produce nearly diffraction-limited two-dimensional focusing x rays of approx1 mum in size at 8 keV. When the sample size is less than approx1 mum, the sample can be illuminated with full coherent x rays by adjusting the cross-slit size set between the source and the mirrors. From the estimated photon density at the sample position, the feasibility of CXDM with a sub-1-nm spatial resolution is suggested. The present ultraprecise figuring process enables us to fabricate mirrors for carrying out high-resolution CXDM experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A general few-projection method for tomographic reconstruction of samples consisting of several distinct materials

We present a method for tomographic reconstruction of objects containing several distinct materials, which is capable of accurately reconstructing a sample from vastly fewer angular projections than required by conventional algorithms. The algorithm is more general than many previous discrete tomography methods, as: (i) a priori knowledge of the exact number of materials is not required; (ii) the linear attenuation coefficient of each constituent material may assume a small range of a priori unknown values. We present reconstructions from an experimental x-ray computed tomography scan of cortical bone acquired at the SPring-8 synchrotron.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Pressure IR Studies of Correlated Electron Materials at SPring-8

The highly bright infrared (IR) synchrotron radiation from SPring-8 offers various research opportunities, including high pressure IR studies of correlated electron materials using a diamond anvil cell. We present our recent results on the reflectivity studies of an f electron compound CeRu{sub 4}Sb{sub 12}, at high pressure up to 8 GPa and at low temperature down to 40 K, measured in both far- and mid-IR ranges.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Full-Automatic XAFS Measurement System of the Engineering Science Research II beamline BL14B2 at SPring-8

The Engineering Science Research II beamline BL14B2 at SPring-8 is a hard X-ray bending magnet beamline covering the wide energy range from 3.8 to 72 keV, and has been open to XAFS users since September 2007. The gas distribution and exhaust gas treatment systems have been installed for the in-situ XAFS measurements. Recent improvements in the speed of XAFS measurements have increased the demand for automated measurements. We have developed such a system, in which the adjustment of X-ray optics and the XAFS measurement in transmission mode can be performed automatically.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Submicrometer Single Crystal Diffractometry for Highly Accurate Structure Determination

Submicrometer single crystal diffractometry for highly accurate structure determination was developed using the extremely stable and highly brilliant synchrotron radiation from SPring-8. This was achieved using a microbeam focusing system and the submicrometer precision low-eccentric goniometer system. We demonstrated the structure analyses with 2x2x2 {mu}m{sup 3} cytidine, 600x600x300 nm{sup 3} BaTiO{sub 3}, and 1x1x1 {mu}m{sup 3} silicon. The observed structure factors of the silicon crystal were in agreement with the structure factors determined by the Pendelloesung method and do not require absorption and extinction corrections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ lattice-strain analysis of a ferroelectric thin film under an applied pulse electric field

We developed an in-situ measurement system for characterizing the relationship between ferroelectricity and lattice distortion of a ferroelectric thin film at BL13XU, SPring-8. The dielectric polarization obtained and the lattice strain evaluated provide us with the electrostrictive coefficient of the film. The system for the method consists of a refractive lens for two dimensional micron focusing, ferroelectric characterization system, high-precision four-circle diffractometer, and time-resolved photon counting system. It enables in-situ measurements of the electric polarization of the film and an electric-field-induced strain using nano-second order time-resolved synchrotron diffraction. We applied the method to determining the lattice constant distorted by the electric field and the polarization value of a 410 nm-thick BiFeO{sub 3} thin film. The piezoelectric constant d{sub 33} evaluated was about 28 pm/V. The polarization observed allowed us to evaluate an electrostrictive coefficient Q of 1{center_dot}4x10{sup -2} m{sup 4}/C{sup 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pump-probe X-ray Diffraction Technique for Irreversible Phase Change Materials

We have developed a pump-probe X-ray diffraction measurement system for a sample with irreversible reaction at BL40XU in the SPring-8. The system mainly consists of a time-resolved measurement system, a sample disk rotation system, and an X-ray microbeam system. The time-resolved measurement system gives time resolution of 50 ps in laser-pump and X-ray probe method. A sample disk rotation system for repetitive measurements was made to give a virgin sample for every measurement. The number of repetitions for one sample disk was increased by using the X-ray microbeam technique. To keep the overlap of the X-ray microbeam and the laser beam on the sample surface during the disk rotation, the sample disk rotation system was constructed by a low-eccentric spindle motor. By using this system, the pump-probe X-ray diffraction measurement was demonstrated for a crystallization process of a DVD material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Hard X-ray Imaging Optics with Two Pairs of Elliptical and Hyperbolic Mirrors

To form a magnified hard X-ray image with a 50 nm resolution, we have studied total reflection mirror optics with two pairs of elliptical and hyperbolic mirrors, which is called 'Advanced Kirkpatrick-Baez system'. A designed optical system has 200x and 300x magnifications in vertical and horizontal directions. Also diffraction limit size in the optical system is 40 nmx45 nm. We fabricated a pair of elliptical and hyperbolic mirrors for horizontal imaging with a figure accuracy of 2 nm using elastic emission machining (EEM), microstitching interferometry (MSI) and relative-angle-determinable stitching interferometry (RADSI). One-dimensional tests for forming a demagnified image of a slit were carried out at an X-ray energy of 11.5 keV at BL29XUL (EH2) of SPring-8. As a result, a shape beam with a FWHM of 78 nm was observed. This demonstrates that we realized one-dimensional Wolter optics that has a spatial resolution of 78 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗