Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Note: Synchronous energy extraction through four output ports of microwave compressor

The energy stored in a resonant cavity was extracted through four output ports and added in phase in a common line. Operation of a single switch provided synchronism and the power portions transmitted through the ports were combined in a waveguide turnstile junction. Estimation shows that the compressor peak power can reach a value eight times as much as the switched wave power, provided the output pulsewidth is shortened by the same factor with reference to the cavity double transit time. The performance of the X-band compressor prototype was investigated. Signals radiated through each of four output ports had identical envelope shapes and equal peak power values. The reflected wave did not accompany the power combining. The pulses of 1.2 MW peak power and 1.6 ns pulse width were obtained when the compressor was driven by the 50 kW pulse power magnetron generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-124: Radiation Biological Equivalent Presentations OfLEM-1 and MKM Approaches in the Carbon-Ion Radiotherapy

Purpose: To study the correlations of the radiation biological equivalent doses (BED) along depth and lateral distance between LEM-1 and MKM approaches. Methods: In NIRS-MKM (Microdosimetric Kinetic Model) approach, the prescribed BED, referred as C-Eq, doses aims to present the relative biological effectiveness (RBE) for different energies of carbon-ions on a fixed 10% survival value of HCG cell with respect to convention X-ray. Instead of a fixed 10% survival, the BED doses of LEM-1 (Local Effect Model) approach, referred as X-Eq, aims to present the RBE over the whole survival curve of chordoma-like cell with alpha/beta ratio of 2.0. The relationship of physical doses as a function of C-Eq and X-Eq doses were investigated along depth and lateral distance for various sizes of cubic targets in water irradiated by carbon-ions. Results: At the center of each cubic target, the trends between physical and C-Eq or X-Eq doses can be described by a linear and 2nd order polynomial functions, respectively. Using fit functions can then calculate a scaling factor between C-Eq and X-Eq doses to have similar physical doses. With equalized C-Eq and X-Eq doses at the depth of target center, over- and under-estimated X-Eq to C-Eq are seen for depths before and after the target center, respectively. Near the distal edge along depth, sharp rising of RBE value is observed for X-Eq, but sharp dropping of RBE value is observed for C-Eq. For lateral locations near and just outside 50% dose level, sharp raising of RBE value is also seen for X-Eq, while only minor increasing with fast dropping for C-Eq. Conclusion: An analytical function to model the differences between the CEq and X-Eq doses along depth and lateral distance need to further investigated to explain varied clinic outcome of specific cancers using two different approaches to calculated BED doses.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Expanded Classification of Hepatitis C Virus Into 7 Genotypes and 67 Subtypes: Updated Criteria and Genotype Assignment Web Resource

The 2005 consensus proposal for the classification of hepatitis C virus (HCV) presented an agreed and uniform nomenclature for HCV variants and the criteria for their assignment into genotypes and subtypes. Since its publication, the available dataset of HCV sequences has vastly expanded through advancement in nucleotide sequencing technologies and an increasing focus on the role of HCV genetic variation in disease and treatment outcomes. The current study represents a major update to the previous consensus HCV classification, incorporating additional sequence information derived from over 1,300 (near-)complete genome sequences of HCV available on public databases in May 2013. Analysis resolved several nomenclature conflicts between genotype designations and using consensus criteria created a classification of HCV into seven confirmed genotypes and 67 subtypes. There are 21 additional complete coding region sequences of unassigned subtype. The study additionally describes the development of a Web resource hosted by the International Committee for Taxonomy of Viruses (ICTV) that maintains and regularly updates tables of reference isolates, accession numbers, and annotated alignments (http://talk.ictvonline.org/links/hcv/hcv-classification.htm). The Flaviviridae Study Group urges those who need to check or propose new genotypes or subtypes of HCV to contact the Study Group in advance of publication to avoid nomenclature conflicts appearing in the literature. While the criteria for assigning genotypes and subtypes remain unchanged from previous consensus proposals, changes are proposed in the assignment of provisional subtypes, subtype numbering beyond “w,” and the nomenclature of intergenotypic recombinant. Conclusion: This study represents an important reference point for the consensus classification of HCV variants that will be of value to researchers working in clinical and basic science fields.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling the potential of screen printed front junction CZ silicon solar cell with tunnel oxide passivated back contact

Carrier selective passivated contacts composed of thin oxide, n + polycrystalline Si and metal on top of a n-Si absorber can significantly lower the recombination current density (J orear ≤8 fA/cm 2 ) under the contact while providing excellent specific contact resistance (5–10 mΩ-cm 2 ); 25.1% efficient small area cells with photolithography front contacts on boron doped selective emitter and Fz wafers have been achieved by Fraunhofer ISE using their tunnel oxide passivated contact (TOPCon) approach. This paper shows a methodology to model such passivated contact cells using Sentaurus device model, which involves replacing the TOPCon region by carrier selective electron and hole recombination velocities to match the measured J orear of the TOPCon region as well as all the light IV values of the cell. We first validated the methodology by modeling a 24.9% reference cell. The model was then extended to assess the efficiency potential of large area TOPCon cells on commercial grade n-type Cz material with screen-printed front contacts. To use realistic input parameters, a 21% n-type PERT cell was fabricated on Cz wafer (5 Ω-cm, 1.5-ms lifetime). Modeling showed that the cell efficiency will improve to only 21.6% if the back of this cell is replaced by the above TOPCon, and the performance is limited by the homogenous emitter. Efficiency was then modeled to improve to 22.6% with the implementation of selective emitter (150/20 Ω/sq). Lastly, it is shown that screen printing of 40-µm-wide lines and improved bulk material (10 Ω-cm, 3-ms lifetime) can raise the single side TOPCon Cz cell efficiency to 23.2%.

14 SOLAR ENERGY↗

Correlation Between Pre- and Postimplant Dosimetry for Iodine-125 Seed Implants for Localized Prostate Cancer

Purpose: In order to evaluate implant quality for permanent prostate brachytherapy in patients with localized prostate cancer, American Brachytherapy Society and ESTRO guidelines recommend that postimplant dosimetry should be performed. To understand more about the relationship between pre- and postimplant dosimetry, a comparison was made of patients who received iodine-125 ({sup 125}I) brachytherapy between March 1995 and the end of 2004, using a preplan technique. Methods and Materials: CT postimplant dosimetry was available for 707 patients. Detailed dose volume analysis was performed using both preimplant ultrasound and postimplant CT data sets for a subgroup of 445 patients. The following parameters were compared: prostate volume covered by 100% of the prescription dose (Vp100), Vp150, and Vp200 and dose to 90% (D90) of the prostate. In addition, volume implanted (Vi) parameters were used to compare pre- and postimplant dosimetry. Vi parameters describe dose levels inside the patient, based on number of seeds, seed activity, and their spatial distribution relative to each other, without reference to the actual prostate volume or position. Results: The mean {+-} standard deviation values of preimplant (34.7 {+-} 8.9 cm{sup 3}) and postimplant (36.7 {+-} 9.4 cm{sup 3}) prostate volumes were similar. The mean ({+-}standard deviation) planned D90 was 183.4 ({+-}12.1) Gy while the D90 that was achieved was 145.5 ({+-}20.4) Gy. Over the study period, there was a steady increase of the average D90. Postimplant CT D90 and Vp100 values correlated significantly (R = 0.84; p < 0.001). The Vi and Vp parameters all showed a strong correlation. Conclusions: In this study, we showed that there is a strong correlation between transrectal ultrasound-based preimplant and CT-based postimplant dosimetry. The excellent correlation between prostate D90 and V100 values demonstrates they are both equally valid quality indices. Vi parameters are an additional measure that can be used to assess the quality of the implant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Schottky contact by Ag on In{sub 2}O{sub 3} (111) single crystals

The barrier height of a metal-semiconductor contact was studied by means of angle-resolved photoemission spectroscopy, which was implemented through stepwise Ag deposition on the ultra-high vacuum cleaved (111) surface of melt-grown In{sub 2}O{sub 3} single crystals. A small Schottky barrier height of 0.22 ± 0.08 eV was determined by following the band bending of the valence band and core level spectra with Ag thickness and corrected for the photovoltage effect. In addition, the work function of Ag and the electron affinity of In{sub 2}O{sub 3} were measured in situ to be 4.30 ± 0.05 eV and 4.18 ± 0.06 eV, respectively. Agreement was observed when comparing the barrier height from band bending to the calculated one by applying the Schottky-Mott rule, yielding a value of 0.12 ± 0.11 eV. Due to an additionally appearing photovoltage, an explicit reference to the surface electron accumulation layer is not necessary when discussing the Schottky character of the Ag/In{sub 2}O{sub 3} contact.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shock revival in core-collapse supernovae: A phase-diagram analysis

We examine the conditions for the revival of the stalled accretion shock in core-collapse supernovae, in the context of the neutrino heating mechanism. We combine one-dimensional simulations of the shock revival process with a derivation of a quasi-stationary approximation, which is both accurate and efficient in predicting the flow. In particular, this approach is used to explore how the evolution of the accretion shock depends on the shock radius, R{sub S}, and velocity, V{sub S} (in addition to other global properties of the system). We do so through a phase-space analysis of the shock acceleration, a{sub S}, in the R{sub S}--V{sub S} plane, shown to provide quantitative insights into the initiation and nature of runaway expansion. In the particular case of an initially stationary (V{sub S}=0, a{sub S}=0) profile, the prospects for an explosion can be assessed by the initial signs of the partial derivatives of the shock acceleration, in analogy to a linear damped/anti-damped oscillator. If ∂a{sub S}/∂R{sub S}<0 and ∂a{sub S}/∂V{sub S}>0, runaway will likely occur after several oscillations, while if ∂a{sub S}/∂R{sub S}>0, runaway expansion will commence in a non-oscillatory fashion. These two modes of runaway correspond to low and high mass accretion rates, respectively. We also use the quasi-stationary approximation to assess the advection-to-heating timescale ratio in the gain region, often used as an explosion proxy. Indeed, this ratio does tend to ∼1 in conjunction with runaway conditions, but neither this unit value nor the specific choice of the gain region as a point of reference appear to be unique in this regard.

79 ASTRONOMY AND ASTROPHYSICS↗

Frames of most uniform Hubble flow

It has been observed [1,2] that the locally measured Hubble parameter converges quickest to the background value and the dipole structure of the velocity field is smallest in the reference frame of the Local Group of galaxies. We study the statistical properties of Lorentz boosts with respect to the Cosmic Microwave Background frame which make the Hubble flow look most uniform around a particular observer. We use a very large N-Body simulation to extract the dependence of the boost velocities on the local environment such as underdensities, overdensities, and bulk flows. We find that the observation [1,2] is not unexpected if we are located in an underdensity, which is indeed the case for our position in the universe. The amplitude of the measured boost velocity for our location is consistent with the expectation in the standard cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Correcting Density Functional Theory for Accurate Predictions of Compound Enthalpies of Formation: Fitted Elemental-Phase Reference Energies

Despite the great success that theoretical approaches based on density functional theory have in describing properties of solid compounds, accurate predictions of the enthalpies of formation ({Delta}H{sub f}) of insulating and semiconducting solids still remain a challenge. This is mainly due to incomplete error cancellation when computing the total energy differences between the compound total energy and the total energies of its elemental constituents. In this paper we present an approach based on GGA + U calculations, including the spin-orbit coupling, which involves fitted elemental-phase reference energies (FERE) and which significantly improves the error cancellation resulting in accurate values for the compound enthalpies of formation. We use an extensive set of 252 binary compounds with measured {Delta}H{sub f} values (pnictides, chalcogenides, and halides) to obtain FERE energies and show that after the fitting, the 252 enthalpies of formation are reproduced with the mean absolute error MAE = 0.054 eV/atom instead of MAE {approx} 0.250 eV/atom resulting from pure GGA calculations. When applied to a set of 55 ternary compounds that were not part of the fitting set the FERE method reproduces their enthalpies of formation with MAE = 0.048 eV/atom. Furthermore, we find that contributions to the total energy differences coming from the spin-orbit coupling can be, to a good approximation, separated into purely atomic contributions which do not affect {Delta}H{sub f}. The FERE method, hence, represents a simple and general approach, as it is computationally equivalent to the cost of pure GGA calculations and applies to virtually all insulating and semiconducting compounds, for predicting compound {Delta}H{sub f} values with chemical accuracy. We also show that by providing accurate {Delta}H{sub f} the FERE approach can be applied for accurate predictions of the compound thermodynamic stability or for predictions of Li-ion battery voltages.

36 MATERIALS SCIENCE↗

Correction factors for A1SL ionization chamber dosimetry in TomoTherapy: Machine-specific, plan-class, and clinical fields

Purpose: Recently, an international working group on nonstandard fields presented a new formalism for ionization chamber reference dosimetry of small and nonstandard fields [Alfonso et al., Med. Phys. 35, 5179-5186 (2008)] which has been adopted by AAPM TG-148. This work presents an experimental determination of the correction factors for reference dosimetry with an Exradin A1SL thimble ionization chamber in a TomoTherapy unit, focusing on: (i) machine-specific reference field, (ii) plan-class-specific reference field, and (iii) two clinical treatments. Methods: Ionization chamber measurements were performed in the TomoTherapy unit for intermediate (machine-specific and plan-class-specific) calibration fields, based on the reference conditions defined by AAPM TG-148, and two clinical treatments (lung and head-and-neck). Alanine reference dosimetry was employed to determine absorbed dose to water at the point of interest for the fields under investigation. The corresponding chamber correction factors were calculated from alanine to ionization chamber measurements ratios. Results: Two different methods of determining the beam quality correction factor k{sub Q,Q{sub 0}} for the A1SL ionization chamber in this TomoTherapy unit, where reference conditions for conventional beam quality determination cannot be met, result in consistent values. The observed values of overall correction factors obtained for intermediate and clinical fields are consistently around 0.98 with a typical expanded relative uncertainty of 2% (k = 2), which when considered make such correction factors compatible with unity. However, all of them are systematically lower than unity, which is shown to be significant when a hypothesis test assuming a t-student distribution is performed (p=1.8x10{sup -2}). Correction factors k{sub Q{sub c{sub l{sub i{sub n,Q{sub p{sub c{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub p}{sub c}{sub s}{sub r}}}}}}}}}} and k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, which are needed for the computation of field factors for relative dosimetry of clinical beams, have been found to be very close to unity for two clinical treatments. Conclusions: The results indicate that the helical field deliveries in this study (including two clinical fields) do not introduce changes on the ion chamber correction factors for dosimetry. For those two specific clinical cases, ratios of chamber readings accurately represent field output factors. The values observed here for intermediate calibration fields are in agreement with previously published data based on alanine dosimetry but differ from values recently reported obtained via radiochromic dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-204-06: Monte Carlo Dose Calculation for Kilovoltage X-Ray-Psoralen Activated Cancer Therapy (X-PACT): Preliminary Results

Purpose: X-PACT is an experimental cancer therapy where kV x-rays are used to photo-activate anti-cancer therapeutics through phosphor intermediaries (phosphors that absorb x-rays and re-radiate as UV light). Clinical trials in pet dogs are currently underway (NC State College of Veterinary Medicine) and an essential component is the ability to model the kV dose in these dogs. Here we report the commissioning and characterization of a Monte Carlo (MC) treatment planning simulation tool to calculate X-PACT radiation doses in canine trials. Methods: FLUKA multi-particle MC simulation package was used to simulate a standard X-PACT radiation treatment beam of 80kVp with the Varian OBI x-ray source geometry. The beam quality was verified by comparing measured and simulated attenuation of the beam by various thicknesses of aluminum (2–4.6 mm) under narrow beam conditions (HVL). The beam parameters at commissioning were then corroborated using MC, characterized and verified with empirically collected commissioning data, including: percent depth dose curves (PDD), back-scatter factors (BSF), collimator scatter factor(s), and heel effect, etc. All simulations were conducted for N=30M histories at M=100 iterations. Results: HVL and PDD simulation data agreed with an average percent error of 2.42%±0.33 and 6.03%±1.58, respectively. The mean square error (MSE) values for HVL and PDD (0.07% and 0.50%) were low, as expected; however, longer simulations are required to validate convergence to the expected values. Qualitatively, pre- and post-filtration source spectra matched well with 80kVp references generated via SPEKTR software. Further validation of commissioning data simulation is underway in preparation for first-time 3D dose calculations with canine CBCT data. Conclusion: We have prepared a Monte Carlo simulation capable of accurate dose calculation for use with ongoing X-PACT canine clinical trials. Preliminary results show good agreement with measured data and hold promise for accurate quantification of dose for this novel psoralen X-ray therapy. Funding Support, Disclosures, & Conflict of Interest: The Monte Carlo simulation work was not funded; Drs. Adamson & Oldham have received funding from Immunolight LLC for X-PACT research.

60 APPLIED LIFE SCIENCES↗

Structural conditionality for the quadratic nonlinear susceptibility of Sr{sub 1-x}Ba{sub x}Nb{sub 2}O{sub 6} crystals

The intensity of the second harmonic generated in powdered samples of the compositions Sr{sub 0.75}Ba{sub 0.25}Nb{sub 2}O{sub 6}, Sr{sub 0.61}Ba{sub 0.39}Nb{sub 2}O{sub 6}, and Sr{sub 0.50}Ba{sub 0.50}Nb{sub 2}O{sub 6} under irradiation by a pulsed-periodic YAG: Nd laser is measured. The effective values of the quadratic nonlinear susceptibility of these materials with respect to the reference sample of potassium dihydrophosphate crystals are estimated. The results obtained are compared with the precise parameters of the atomic structure of the single crystals with the corresponding compositions. It is established that the dominant contribution to the nonlinear optical susceptibility of the single crystals under investigation comes from the chains aligned parallel to the c axis of the crystal and composed of Nb octahedra with regularly alternating increased and decreased Nb-O interatomic distances. The occurrence of such a sequence in the crystal structure suggests an alternation of stronger and weaker chemical bonds in the chains -O=Nb-O=Nb-O=. These bonds are characterized by different charge electron densities, a phenomenon confirmed by the X-ray diffraction analysis, which indicates not only a difference in the Nb-O bond lengths but also an anharmonicity in the thermal vibrations of the niobium atoms. The revealed anharmonicity is associated with the difference between the chemical bonds of the niobium atoms with the oxygen atoms located in trans positions in the octahedra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fuel Cycle Services Needs Estimator v.2.0

The "Fuel Cycle Services Needs Estimator", Version 2.0 allows users to estimate the amount of uranium enrichment services needed and amount of spent nuclear fuel produced by a given fleet of nuclear power reactors through 2050 based on user-determined information about the size of a reactor fleet and average characteristics of reactors in that fleet. The program helps users evaluate the current and future supply of nuclear fuel cycle services. The program also allows users to compare the enrichment needs and spent fuel production of more up to seven defined nuclear power reactor fleets and to aggregate estimated needs. Version 2.0 of the program has an additions of new graphs to show results of calculations (calculation capabilities and other graphing tools included in version 1.o), maps showing flows of material based on calculation results, and additional calculation capabilities that allow the user to compare supply to demand (demand calculations included in version 1.0). Default values for seven selected nuclear energy programs in East Asia are included for reference and comparison. The program was designed using the dynamic simulation software, Powersim.

Saltiel, DavidH.↗

Analysis of the dependence of critical electric field on semiconductor bandgap

Abstract Understanding of semiconductor breakdown under high electric fields is an important aspect of materials’ properties, particularly for the design of power devices. For decades, a power-law has been used to describe the dependence of material-specific critical electrical field ( $${\mathcal{E}}_{\text{crit}}$$ E crit ) at which the material breaks down and bandgap ( E g ) . The relationship is often used to gauge tradeoffs of emerging materials whose properties haven’t yet been determined. Unfortunately, the reported dependencies of $${\mathcal{E}}_{\text{crit}}$$ E crit on E g cover a surprisingly wide range in the literature. Moreover, $${\mathcal{E}}_{\text{crit}}$$ E crit is a function of material doping. Further, discrepancies arise in $${\mathcal{E}}_{\text{crit}}$$ E crit values owing to differences between punch-through and non-punch-through device structures. We report a new normalization procedure that enables comparison of critical electric field values across materials, doping, and different device types. An extensive examination of numerous references reveals that the dependence $${\mathcal{E}}_{\text{crit}}$$ E crit ∝ E g 1.83 best fits the most reliable and newest data for both direct and indirect semiconductors. Graphical abstract

36 MATERIALS SCIENCE↗

Ionization potential and electron affinity for six common explosive compounds by DFT, MP2, and CBS-QB3

The vertical and adiabatic ionization potential (IP V and IP A ) and vertical electron affinity (EA V ) for six explosives (RDX, HMX, TNT, PETN, HMTD, and TATP) have been studied by ab initio computational methods. The IPV was calculated using MP2 and CBS-QB3 while the IP A was calculated with B3LYP, CAM-B3LYP, ω B97XD, B2PLYP, and MP2. RDX and TNT IP A ’s were also reported using CBS -QB3. Excluding results by CBS-QB3, B3LYP and B2PLYPD provided superior and more consistent results for calculating the IP. The EA V were calculated using the same methods however B3LYP performed the worst in this case with MP2 and B2PLYPD predicting values closest to those made by CBS-QB3, which was used a reference due to lacking experimental data. Basis set effects were evaluated using 6- 31+G(d,p), 6-311+G(d,p), and 6-311+(3df,2p) for both IP and EA. 6-31+G(d,p) gave satisfactory results for calculating both IP however 6-311+G(3df,2p) had improved results in calculating the EA. The four nitro containing compounds had exothermic reduction potentials while the peroxides were unfavorable. Additionally, it was seen that RDX, HMX, TATP and HMTD were unstable in their reduced forms. Results are aimed to assist detection and screening methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Semiconductor Laser Diode Pumps for Inertial Fusion Energy Lasers

Solid-state lasers have been demonstrated as attractive drivers for inertial confinement fusion on the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) and at the Omega Facility at the Laboratory for Laser Energetics (LLE) in Rochester, NY. For power plant applications, these lasers must be pumped by semiconductor diode lasers to achieve the required laser system efficiency, repetition rate, and lifetime. Inertial fusion energy (IFE) power plants will require approximately 40-to-80 GW of peak pump power, and must operate efficiently and with high system availability for decades. These considerations lead to requirements on the efficiency, price, and production capacity of the semiconductor pump sources. This document provides a brief summary of these requirements, and how they can be met by a natural evolution of the current semiconductor laser industry. The detailed technical requirements described in this document flow down from a laser ampl9ifier design described elsewhere. In brief, laser amplifiers comprising multiple Nd:glass gain slabs are face-pumped by two planar diode arrays, each delivering 30 to 40 MW of peak power at 872 nm during a {approx} 200 {micro}s quasi-CW (QCW) pulse with a repetition rate in the range of 10 to 20 Hz. The baseline design of the diode array employs a 2D mosaic of submodules to facilitate manufacturing. As a baseline, they envision that each submodule is an array of vertically stacked, 1 cm wide, edge-emitting diode bars, an industry standard form factor. These stacks are mounted on a common backplane providing cooling and current drive. Stacks are conductively cooled to the backplane, to minimize both diode package cost and the number of fluid interconnects for improved reliability. While the baseline assessment in this document is based on edge-emitting devices, the amplifier design does not preclude future use of surface emitting diodes, which may offer appreciable future cost reductions and increased reliability. The high-level requirements on the semiconductor lasers involve reliability, price points on a price-per-Watt basis, and a set of technical requirements. The technical requirements for the amplifier design in reference 1 are discussed in detail and are summarized in Table 1. These values are still subject to changes as the overall laser system continues to be optimized. Since pump costs can be a significant fraction of the overall laser system cost, it is important to achieve sufficiently low price points for these components. At this time, the price target for tenth-of-akind IFE plant is $0.007/Watt for packaged devices. At this target level, the pumps account for approximately one third of the laser cost. The pump lasers should last for the life of the power plant, leading to a target component lifetime requirement of roughly 14 Ghosts, corresponding to a 30 year plant life and 15 Hz repetition rate. An attractive path forward involes pump operation at high output power levels, on a Watts-per-bar (Watts/chip) basis. This reduces the cost of pump power (price-per-Watt), since to first order the unit price does not increase with power/bar. The industry has seen a continual improvement in power output, with current 1 cm-wide bars emitting up to 500 W QCW (quasi-continuous wave). Increased power/bar also facilitates achieving high irradiance in the array plane. On the other hand, increased power implies greater heat loads and (possibly) higher current drive, which will require increased attention to thermal management and parasitic series resistance. Diode chips containing multiple p-n junctions and quantum wells (also called nanostack structures) may provide an additional approach to reduce the peak current.

42 ENGINEERING↗

Advanced Fuel Cycle Cost Basis Report: Module D1-4 and Module D1-5 Ceramic Pelletized Sodium-Cooled Fast Reactor (SFR) Fuel Fabrication Ceramic Vibrocompacted Fuel Fabrication

This is a cost module that is part of the Advanced Fuel Cycle -- Cost Basis Report. Module D1-4: Nature of this module update (Rev 1) from previous advanced fuel cycle cost basis reports (AFCCBRs): new life cycle cost data on U,Pu SFR mixed oxide (MOX) fuels is derived from the Nonproliferation Assessment Systems Analysis Program (NASAP) conducted in the late 1970s. Highassay low-enriched uranium (HALEU) ceramic fuel is also discussed in more detail compared to earlier AFC-CBRs, since some advanced SFR concepts currently under development will require this HALEU fuel type for startup. Module D1-5: Nature of this FY-21 module update from previous AFC-CBRs: this module includes a few new references and a somewhat expanded discussion of vibrocompaction fuel fabrication technology. The WIT values for VIPAC are pegged directly to those for conventional LWR and SFR pelletized U,Pu MOX (note that this module now includes VIPAC MOX fuel for LWRs in addition to SFRs). Based on information from Russia, where VIPAC has been studied extensively, the unit costs are expressed as a percentage of those in the new updated Module D1-2 (pelletized U,Pu MOX) and new updated Module D1-4 (pelletized U,Pu MOX) for large NOAK fabrication facilities of the same production capacity. Since both ceramic pelletized MOX Modules D1-2 and D1-4 benefitted from analysis of 1970s NASAP data, by extension this Module D1-5 also benefits.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗