Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

High x-ray resolving power utilizing asymmetric diffraction from a quartz transmission crystal measured in the 6 keV to 22 keV energy range

We report a Cauchois-type spectrometer utilizing the (203) lattice planes at an oblique angle of 11.53° to the normal to the surface of a quartz transmission crystal recorded the Kα and Kβ spectral lines of six elements from Fe to Ag in the 6–22 keV energy range from a laboratory x-ray source. After deconvolving the natural lifetime widths and the image plate detector broadening from the observed spectral linewidths, the intrinsic crystal resolving power was determined to be 4000 at the lower energies and decreasing to 1000 at the higher energies. Previously, a Si wafer crystal exhibited twice this resolving power when the (331) planes had been used in asymmetric geometry. The investigation of diffraction with this quartz crystal, with a very similar lattice spacing and therefore spectral coverage, was motivated by the larger integrated reflectivity of quartz due to its well-known quasimosaicity upon elastic bending. The measured spectral linewidths were in good agreement with the widths calculated by accounting for various broadening mechanisms, including source size, crystal thickness, crystal height, crystal rocking curve width, geometrical aberrations, and possible spectrometer configuration errors. This is the first, to the best of our knowledge, demonstration of high resolving power achieved by asymmetric diffraction over a wide energy range (6–22 keV) and with detailed comparisons with theoretical broadenings. Finally, based on these results, Cauchois spectrometers employing asymmetric planes of perfect quartz and silicon crystals can be reliably designed and optimized for high-resolution spectroscopy in the >6 keV energy range.

36 MATERIALS SCIENCE↗

Long-Range Intra-Protein Communication Can Be Transmitted by Correlated Side-Chain Fluctuations Alone

Allosteric regulation is a key component of cellular communication, but the way in which information is passed from one site to another within a folded protein is not often clear. While backbone motions have long been considered essential for long-range information conveyance, side-chain motions have rarely been considered. In this work, we demonstrate their potential utility using Monte Carlo sampling of side-chain torsional angles on a fixed backbone to quantify correlations amongst side-chain inter-rotameric motions. Results indicate that long-range correlations of side-chain fluctuations can arise independently from several different types of interactions: steric repulsions, implicit solvent interactions, or hydrogen bonding and salt-bridge interactions. These robust correlations persist across the entire protein (up to 60 Å in the case of calmodulin) and can propagate long-range changes in side-chain variability in response to single residue perturbations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Eureka: Enabling Fine-Grained Access and Range Queries on Compressed Scientific Data via Data-Index Co-Compression

Handling large-scale scientific data in high-performance computing (HPC) environments poses significant challenges, including excessive I/O, high storage costs, and slow query performance. Traditional approaches often require full data decompression and scans, making them impractical for real-time or interactive analysis. To address these limitations, we introduce Eureka, a unified data-index co-compression framework that enables fine-grained access and efficient range queries on compressed scientific datasets. Eureka integrates spatial domain decomposition with block-wise error-bounded lossy compression to support selective decompression. It constructs a hierarchical AVL-tree index during compression to capture block-level value ranges, enabling fast pruning during query execution. To reduce metadata overhead, the index itself is also compressed while ensuring recall-preserving results. Experiments on six diverse HPC simulation datasets show that Eureka achieves up to 25x data compression and over 300x index compression, surpassing state-of-the-art compressors such as SZ3 and ZFP in rate-distortion performance. Additionally, Eureka delivers over 30x speedup for low-selectivity range queries, making it a scalable and efficient solution for modern scientific data analysis.

Yan, Ning↗

Long-range, low-cost electric vehicles enabled by robust energy storage

ABSTRACT A variety of inherently robust energy storage technologies hold the promise to increase the range and decrease the cost of electric vehicles (EVs). These technologies help diversify approaches to EV energy storage, complementing current focus on high specific energy lithium-ion batteries. The need for emission-free transportation and a decrease in reliance on imported oil has prompted the development of EVs. To reach mass adoption, a significant reduction in cost and an increase in range are needed. Using the cost per mile of range as the metric, we analyzed the various factors that contribute to the cost and weight of EV energy storage systems. Our analysis points to two primary approaches for minimizing cost. The first approach, of developing redox couples that offer higher specific energy than state-of-the-art lithium-ion batteries, dominates current research effort, and its challenges and potentials are briefly discussed. The second approach represents a new insight into the EV research landscape. Chemistries and architectures that are inherently more robust reduce the need for system protection and enables opportunities of using energy storage systems to simultaneously serve vehicle structural functions. This approach thus enables the use of low cost, lower specific energy chemistries without increasing vehicle weight. Examples of such systems include aqueous batteries, flow cells, and all solid-state batteries. Research progress in these technical areas is briefly reviewed. Potential research directions that can enable low-cost EVs using multifunctional energy storage technologies are described.

36 MATERIALS SCIENCE↗

Observation of Associated Near-Side and Away-Side Long-Range Correlations in s N N =5.02 TeV Proton-Lead Collisions with the ATLAS Detector

CERN-LHC. Two-particle correlations in relative azimuthal angle, Delta(phi), and pseudorapidity, Delta(eta), are measured in sqrt(sNN) = 5.02 TeV p+Pb collisions recorded in September 2012 using the ATLAS detector at the LHC. The measurements are performed using approximately 1 mub^1 of data as a function of transverse momentum (pT) and the transverse energy summed over 3.1 < eta < 4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2 < |Delta(eta)| < 5) near-side (Delta(phi) ~ 0) correlation that grows rapidly with increasing transverse energy. A long-range away-side (Delta(phi) ~ pi) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small transverse energy, is found to match the near-side correlation in magnitude, shape (in Delta(eta) and Delta(phi)) and transverse energy dependence. The resultant Delta(phi) correlation is approximately symmetric about pi/2, and is consistent with a dominant cos(2*Delta(phi)) modulation for all transverse energy ranges and particle pT.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AmeriFlux US-xSR NEON Santa Rita Experimental Range (SRER)

This is the AmeriFlux version of the carbon flux data for the site US-xSR NEON Santa Rita Experimental Range (SRER). Site Description - Santa Rita Experimental Range encompasses 21,000 hectares of upland Sonoran Desert, approximately 32 km south of Tucson, Arizona. Santa Rita Experimental Range was founded in 1903. It is the longest continuously active rangeland research facility and among the five oldest biological field stations in the United States. The site is broken into distinct pastures, through which cattle graze throughout the year in various densities and durations.

Network), NEON (National Ecological Observatory↗

AmeriFlux US-Jo1 Jornada Experimental Range Bajada Site

This is the AmeriFlux version of the carbon flux data for the site US-Jo1 Jornada Experimental Range Bajada Site. Site Description - The Jornada Basin Experimental Range (JER) covers 783 km2 in the La Jornada del Muerto Plain of the northern Chihuahuan Desert and is located 20km of Las Cruces, NM. Extensive livestock grazing at the JER and througout the US Southwest was coincident with large-scale grassland deterioration and transition to shrubland begining in the 1800s. The JER was established n 1912 to investigate these rangeland changes and has since become a central location for understanding dryland ecology. This flux tower monitors CO2 and H2O dynamics in a representative shrubland on the piedmont slope (bajada) of the San Andreas mountains. The dominant shrubs are evergreen Larrea tridentata (Creosote) and winter-deciduous Prosopis glandulosa (Honey Mesquite). Other cover types include Flourensia cernua (tarbush) and patchy occurences of the grasses Muhlenbergia porteri (Bush Muhly) and Dasyochloa pulchella (Fluff Grass). The site is occasionally visited by stray domestic cattle, free-ranging introduced Oryx, and other native herbivores (Jack Rabbits, Desert Pronghorn). Soils at the site are Ustic Calciargids and parent material consists of limestone, other sedimentary rock, and some igneous rock. Virtual Site Visit: https://youtu.be/v1uJCKuicqs​

Tweedie, Craig↗

AmeriFlux FLUXNET-1F US-Jo2 Jornada Experimental Range Mixed Shrubland

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Jo2 Jornada Experimental Range Mixed Shrubland. This is the FLUXNET version of the carbon flux data for the site US-Jo2 Jornada Experimental Range Mixed Shrubland produced by applying the standard ONEFlux (1F) software. Site Description - The study area is in a mixed shrub-dominated portion of the San Andres Mountain piedmont, along the southeastern boundary of the Jornada Experimental Range (JER) in southern New Mexico, USA. The JER was established in 1912 as a response of scientis and landowner to the shrub enchroachment and loss of grasses due to extended grazing during the late 1800s, fire and climate change. JER has been a NSF LTER site since 1981.The study site is a small watershed (4.67 ha) in an alluvial slope or bajada, with three major areas (north-, south- and west-facing hillslopes) with low to moderate slopes (∼0–6°) with a mean slope of 2.6°, while the channel banks and propagating channel heads have higher slopes (∼15–25°). The site is charactetized by a high bare soil coverage (∼66%), ∼28% of mixed shrubs coverage and a low coverage of grass (∼4%) and weeds (∼2%).

Vivoni, Enrique R.↗

AmeriFlux FLUXNET-1F US-xAE NEON Klemme Range Research Station (OAES)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-xAE NEON Klemme Range Research Station (OAES). This is the FLUXNET version of the carbon flux data for the site US-xAE NEON Klemme Range Research Station (OAES) produced by applying the standard ONEFlux (1F) software. Site Description - The 1,560-acre Klemme Range Research Station is a grassland site managed for livestock grazing and pasture, located in the middle of the Rolling Red Plains Resource Area. The Rolling Red Plains extends from south of the Red River to north of the Oklahoma/Kansas border consisting of approximately 9.4 million acres, which occupies a significant portion of Western Oklahoma excluding the Oklahoma Panhandle.

Network), NEON (National Ecological Observatory↗

AmeriFlux FLUXNET-1F US-xCP NEON Central Plains Experimental Range (CPER)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-xCP NEON Central Plains Experimental Range (CPER). This is the FLUXNET version of the carbon flux data for the site US-xCP NEON Central Plains Experimental Range (CPER) produced by applying the standard ONEFlux (1F) software. Site Description - Central Plains Experimental Range (CPER) site in north central Colorado. CPER served as part of the Shortgrass Steppe LTER from 1982-2014 and is now home to a fully instrumented NEON site and a wealth of relevant historical data as well as ongoing collections of complementary data(i.e. airborne remote sensing, soil temperature and moisture, phenology measurements, plant biomass and more)

Network), NEON (National Ecological Observatory↗

AmeriFlux FLUXNET-1F US-Rpf Poker Flat Research Range: Succession from fire scar to deciduous forest

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Rpf Poker Flat Research Range: Succession from fire scar to deciduous forest. This is the FLUXNET version of the carbon flux data for the site US-Rpf Poker Flat Research Range: Succession from fire scar to deciduous forest produced by applying the standard ONEFlux (1F) software. Site Description - This tower is located near Davis Center, Poker Flat Research Range. Deciduous trees and shrubs are dominated at the burned black spruce forest.

Ueyama, Masahito↗

AmeriFlux FLUXNET-1F US-xSJ NEON San Joaquin Experimental Range (SJER)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-xSJ NEON San Joaquin Experimental Range (SJER). This is the FLUXNET version of the carbon flux data for the site US-xSJ NEON San Joaquin Experimental Range (SJER) produced by applying the standard ONEFlux (1F) software. Site Description - Located at The San Joaquin Experimental Range, in the western foothills of the Sierra Nevada, this 18.2 kilometer terrestrial field site is a mix of open woodlands, shrubs and grasslands with low density cattle grazing. SJER is an ecosystem research experimental area. It was originally conceived as a cooperative interdisciplinary research center to identify cost-effect methods of commercial livestock production in the annual grass-oak pine woodlands, while maintaining the integrity of the ecosystem. More recently, research objectives have expanded and diversified to include research projects making contributions to our knowledge of the patterns and processes working in this ecosystem.

Network), NEON (National Ecological Observatory↗

AmeriFlux FLUXNET-1F US-Prr Poker Flat Research Range Black Spruce Forest

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Prr Poker Flat Research Range Black Spruce Forest. This is the FLUXNET version of the carbon flux data for the site US-Prr Poker Flat Research Range Black Spruce Forest produced by applying the standard ONEFlux (1F) software. Site Description - This site is located in a blackspruce forest within the property of the Poker Flat Research Range, University of Alaska, Fairbanks. Time-lapse image of the canopy is measured at the same time to relate flux data to satellite images.

Iwahana, Go [University of Alaska, Faribanks]↗

Observations On Submicropulse Electron-beam Effects From Short-range Wakefields In Tesla-type Superconducting RF Cavities

aExperiments were performed at The Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of short-range wakefields (SRWs) in TESLA-type rf cavities. FAST has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then selected a vertical corrector to steer the beam off axis at an angle into CC1 or CC2. A Hamamatsu synchro-scan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 2 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is consistent wit h a calculated short-range wakefield effect using ASTRA simulations.

43 PARTICLE ACCELERATORS↗

Tonopah Test Range Air Monitoring: CY2012 Meteorological, Radiological, and Airborne Particulate Observations

In 1963, the Atomic Energy Commission (AEC), predecessor to the US Department of Energy (DOE), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range (NAFR)). Operation Roller Coaster consisted of four tests in which chemical explosions were detonated in the presence of nuclear devices to assess the dispersal of radionuclides and evaluate the effectiveness of storage structures to contain the ejected radionuclides. These tests resulted in dispersal of plutonium over the ground surface downwind of the test ground zero. Three tests, Clean Slate 1, 2, and 3, were conducted on the TTR in Cactus Flat; the fourth, Double Tracks, was conducted in Stonewall Flat on the NTTR.

54 ENVIRONMENTAL SCIENCES↗

Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector

Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Limits on Gravitational Waves in the MHz Frequency Range

This thesis presents the results of a search for gravitational waves in the 1-11MHz frequency range using dual power-recycled Michelson laser interferometers at Fermi National Accelerator Laboratory. An unprecedented level of sensitivity to gravitational waves in this frequency range has been achieved by cross-correlating the output fluctuations of two identical and co-located 40m long interferometers. This technique produces sensitivities better than two orders of magnitude below the quantum shot-noise limit, within integration times of less than 1 hour. 95% confidence level upper limits are placed on the strain amplitude of MHz frequency gravitational waves at the $10^{-21}\ \mathrm{Hz}^{-1/2}$ level, constituting the best direct limits to date at these frequencies. For gravitational wave power distributed over this frequency range, a broadband upper limit of $2.4\times10^{-21}\mathrm{Hz}^{-1/2}$ at 95% confidence level is also obtained. This thesis covers the detector technology, the commissioning and calibration of the instrument, the statistical data analysis, and the gravitational wave limit results. Particular attention is paid to the end-to-end calibration of the instrument's sensitivity to differential arm length motion, and so to gravitational wave strain. A detailed statistical analysis of the data is presented as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DIRECT OBSERVATIONS OF SUBMICROPULSE ELECTRON-BEAM EFFECTS FROM SHORT-RANGE WAKEFIELDS IN TESLA-TYPE SUPERCONDUCTING RF CAVITIES

Experiments were performed at The Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of short-range wakefields (SRWs) in TESLA-type rf cavities. FAST has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then used a vertical corrector between the two cavities to steer the beam off axis at an angle into CC2. A Hamamatsu synchroscan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 4 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is 5 times l arger than the observed HOM-driven centroid oscillation within the macropulse, and it is consistent with a calculated short-range wakefield effect using ASTRA simulations.

43 PARTICLE ACCELERATORS↗