SU-E-CAMPUS-T-05: Validation of High-Resolution 3D Patient QA for Proton Pencil Beam Scanning and IMPT by Polymer Gel Dosimetry

Purpose: Validation of high-resolution 3D patient QA for proton pencil beam scanning and IMPT by polymer gel dosimetry. Methods: Four BANG3Pro polymer gel dosimeters (manufactured by MGS Research Inc, Madison, CT) were used for patient QA at the Robert's Proton Therapy Center (RPTC, Philadelphia, PA). All dosimeters were sealed in identical thin-wall Pyrex glass spheres. Each dosimeter contained a set of markers for 3D registration purposes. The dosimeters were mounted in a consistent and reproducible manner using a custom build holder. Two proton pencil beam scanning plans were designed using Varian Eclipse™ treatment planning system: 1) A two-field intensity modulated proton therapy (IMPT) plan and 2) one single field uniform dose (SFUD) plan. The IMPT fields were evaluated as a composite plan and individual fields, the SFUD plan was delivered as a single field plan.Laser CT scanning was performed using the manufacturer's OCTOPUS-IQ axial transmission laser CT scanner using a 1 mm slice thickness. 3D registration, analysis, and OD/cm to absorbed dose calibrations were perfomed using DICOM RT-Dose and CT files, and software developed by the manufacturer. 3D delta index, a metric equivalent to the gamma tool, was used for dose comparison. Results: Very good agreement with single IMPT fields and with SFUD was obtained. Composite IMPT fields had a less satisfactory agreement. The single fields had 3D delta index passing rates (3% dose difference, 3 mm DTA) of 98.98% and 94.91%. The composite 3D delta index passing rate was 80.80%. The SFUD passing rate was 93.77%. Required shifts of the dose distributions were less than 4 mm. Conclusion: A formulation of the BANG3Pro polymer gel dosimeter, suitable for 3D QA of proton patient plans is established and validated. Likewise, the mailed QA analysis service provided by the manufacturer is a practical option when required resources are unavailable. We fully disclose that the subject of this research regards a production of MGS Research, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-09: Assessment of OSL Dosimeter Technology in the Validation of a Monte Carlo Radiation Transport Code for CT Dosimetry

Purpose: To assess the utility of optically stimulated luminescent (OSL) dosimeter technology in calibrating and validating a Monte Carlo radiation transport code for computed tomography (CT). Methods: Exposure data were taken using both a standard CT 100-mm pencil ionization chamber and a series of 150-mm OSL CT dosimeters. Measurements were made at system isocenter in air as well as in standard 16-cm (head) and 32-cm (body) CTDI phantoms at isocenter and at the 12 o'clock positions. Scans were performed on a Philips Brilliance 64 CT scanner for 100 and 120 kVp at 300 mAs with a nominal beam width of 40 mm. A radiation transport code to simulate the CT scanner conditions was developed using the GEANT4 physics toolkit. The imaging geometry and associated parameters were simulated for each ionization chamber and phantom combination. Simulated absorbed doses were compared to both CTDI{sub 100} values determined from the ion chamber and to CTDI{sub 100} values reported from the OSLs. The dose profiles from each simulation were also compared to the physical OSL dose profiles. Results: CTDI{sub 100} values reported by the ion chamber and OSLs are generally in good agreement (average percent difference of 9%), and provide a suitable way to calibrate doses obtained from simulation to real absorbed doses. Simulated and real CTDI{sub 100} values agree to within 10% or less, and the simulated dose profiles also predict the physical profiles reported by the OSLs. Conclusion: Ionization chambers are generally considered the standard for absolute dose measurements. However, OSL dosimeters may also serve as a useful tool with the significant benefit of also assessing the radiation dose profile. This may offer an advantage to those developing simulations for assessing radiation dosimetry such as verification of spatial dose distribution and beam width.

61 RADIATION PROTECTION AND DOSIMETRY↗

Does administering iodine in radiological procedures increase patient doses?

Purpose: The authors investigated the changes in the pattern of energy deposition in tissue equivalent phantoms following the introduction of iodinated contrast media. Methods: The phantom consisted of a small “contrast sphere,” filled with water or iodinated contrast, located at the center of a 28 cm diameter water sphere. Monte Carlo simulations were performed using MCNP5 codes, validated by simulating irradiations with analytical solutions. Monoenergetic x-rays ranging from 35 to 150 keV were used to simulate exposures to spheres containing contrast agent with iodine concentrations ranging from 1 to 100 mg/ml. Relative values of energy imparted to the contrast sphere, as well as to the whole phantom, were calculated. Changes in patterns of energy deposition around the contrast sphere were also investigated. Results: Small contrast spheres can increase local absorbed dose by a factor of 13, but the corresponding increase in total energy absorbed was negligible (<1%). The highest localized dose increases were found to occur at incident photon energies of about 60 keV. For a concentration of about 10 mg/ml, typical of clinical practice, localized absorbed doses were generally increased by about a factor of two. At this concentration of 10 mg/ml, the maximum increase in total energy deposition in the phantom was only 6%. These simulations demonstrated that increases in contrast sphere doses were offset by corresponding dose reductions at distal and posterior locations. Conclusions: Adding iodine can result in values of localized absorbed dose increasing by more than an order of magnitude, but the total energy deposition is generally very modest (i.e., <10%). Their data show that adding iodine primarily changes the pattern of energy deposition in the irradiated region, rather than increasing patient doses per se.

60 APPLIED LIFE SCIENCES↗

SU-E-P-07: Retrospective Analysis of Incident Reports at a Radiology Department: Feedback From Incident Reporting System

Purpose: To provide an overview of reported incidents that occurred in a radiology department and to describe the most common causal source of incidents. Methods: Incident reports from the radiology department at the University of the Ryukyus Hospital between 2008 and 2013 were collected and analyzed retrospectively. The incident report form contains the following items, causal factors of the incident and desirable corrective actions to prevent recurrence of similar incidents. These items allow the institution to investigate/analyze root causes of the incidents and suggest measures to be taken to prevent further, similar incidents. The ‘causal factors of the incident’ item comprises multiple selections from among 24 selections and includes some synonymous selections. In this study, this item was re-categorized into four causal source types: (i) carelessness, (ii) lack of skill or knowledge, (iii) deficiencies in communication, and (iv) external factors. Results: There were a total of 7490 incident reports over the study period and 276 (3.7%) were identified as originating from the radiology department. The most frequent causal source type was carelessness (62%). The other three types showed similar frequencies (10–14%). The staff members involved in incidents indicate three predominant desirable corrective actions to prevent or decrease the recurrence of similar incidents. These are ‘improvement in communication’ (24%), ‘staff training/education’ (19%), and ‘daily medical procedures’ (22%), and the most frequent was ‘improvement in communication’. Even though the most frequent causal factor was related to carelessness, the most desirable corrective action indicated by the staff members was related to communication. Conclusion: Our finding suggests that the most immediate causes are strongly related to carelessness. However, the most likely underlying causes of incidents would be related to deficiencies in effective communication. At our department, therefore, the primary action to prevent/reduce similar incidents should be ‘communication improvement’.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-167: Characterization of In-House Plastic Scintillator Detectors Array for Radiation Therapy

Purpose: To characterize basic performance of plastic scintillator detectors (PSD) array designed for dosimetry of radiation therapy. Methods: An in-house PSD array has been developed by placing single point PSD into customized 2D holder. Each point PSD is a plastic scintillating fiber-based detector designed for highly accurate measurement of small radiotherapy fields used in patient plan verification and machine commissioning and QA procedures. A parallel fiber without PSD is used for Cerenkov separation by subtracting from PSD readings. Cerenkov separation was confirmed by optical spectroscopy. Alternative Cerenkov separation approaches are also investigated. The optical signal was converted to electronic signal with a photodiode and then subsequently amplified. We measured its dosimetry performance, including percentage depth dose and output factor, and compared with reference ion chamber measurements. The PSD array is then placed along the radiation beam for multiple point dose measurement, representing subsets of PDD measurements, or perpendicular to the beam for profile measurements. Results: The dosimetry results of PSD point measurements agree well with reference ion chamber measurements. For percentage depth dose, the maximal differences between PSD and ion chamber results are 3.5% and 2.7% for 6MV and 15MV beams, respectively. For the output factors, PSD measurements are within 3% from ion chamber results. PDD and profile measurement with PSD array are also performed. Conclusions: The current design of multichannel PSD array is feasible for the dosimetry measurement in radiation therapy. Dose distribution along or perpendicular to the beam path could be measured. It might as well be used as range verification in proton therapy.A PS hollow fiber detector will be investigated to eliminate the Cerenkov radiation effect so that all 32 channels can be used.

60 APPLIED LIFE SCIENCES↗

SU-E-T-340: Dosimetry of a Small Field Electron Beam for Innovative Radiotherapy of Small Surface Or Internal Tumors

Purpose: An innovative small high intensity electron beams with energies from 6 to 12 MeV is being developed at Argonne National Laboratory to deliver an absorbed dose via a catheter to small malignant and nonmalignant lesions. This study reports on the initial dosimetric characteristics of this electron beam. These include output calibration, percent depth dose, beam profiles and leakage through the catheter. Methods: To simulate the narrow electron beam, the Argonne Wakefield Accelerator is used to produce high energy electron beams. The electron beam from the accelerator is monitored by measuring the current through a transmission coil while the beam shape is observed with a fluorescent screen. The dosimetry properties of the electron beam transmitting through bone and tissue-like materials are measured with nanodot optically stimulated luminescent dosimeters and EDR radiographic film. The 6 MV photon beam from a Varian True beam linac is used to calibrate both the OSLDs and the film. Results: The beam characteristics of the 12 MeV beam were measured. The properties of the small diameter, 5 mm, beam differs from that of broad clinical electron beams from radiotherapy linacs. Due to the lack of scatter from the narrow beam, the maximum dose is at the surface and the depth of the 50% depth dose is 35 mm compared to 51 mm for a clinical 12 MeV. The widths of the 90% isodose measured at the surface and depths of 2, 6, 12, and 16 mm varied from 6.6 to 8.8 mm while the widths of the FWHM isodose varied from 7.8 to 25.5 mm. Conclusion: Initial beam measurements show favorable dosimetric properties for its use in treating either small surface or internal lesions, particularly to deliver radiation at the time of surgery to maximize the dose to the lesion and spare normal tissue.

60 APPLIED LIFE SCIENCES↗

SU-E-T-390: Evaluation of Heterogeneity Corrections Made by RayStation Treatment Planning

Purpose: To examine the agreement between absorbed doses calculated by RayStation treatment planning algorithm to those measured with gafchromic film and ion chamber when the photon beam is perturbed by attenuation or lateral scatter of lung material. Methods: A gafchromic EBT2 film was placed in the center of a 30×30×20 cm{sup 3} solid water phantom with a 5 cm lung slab placed at 10 cm depth. The film was irradiated at SSD = 100 cm with a 6 MV photon beam, 10×10 and 5×5 cm{sup 2} field sizes and with the beam parallel to the film and lung slab. A CT was performed to the phantom arrangement for RayStation dose calculation. The films were scanned in an Epson 10000X flatbed scanner and analyzed using the red channel, 16 bits, 76 dpi. PDD curves at the central axis and profiles at dmax were also measured in water using a CC13 (0.13 CC) ion chamber. Measurements and calculation of PDD curves at the central axis and profiles at dmax and 20 cm depth were compared using the criteria suggested by the AAPM Task Group # 53. Results: The PDD curves measured with gafchromic film and those measured in water with ion chamber agree with the ones calculated by RayStation within the uncertainty of the measurements which is within 3%. The passing rate values of the measured and calculated profiles for the 2 field sizes are within 94% for both at dmax and at 20 cm depth. Conclusion: Raystation dose calculation engine models inhomogeneity corrections. Differences between the calculated PDD curves and profiles and those measured with gafchromic film are within the uncertainty of the measurements and inside of the agreement tolerance suggested by TG53. Therefore, RayStation treatment planning has an acceptable algorithm to correct dose delivered by photon beams perturbed by lung tissue.

60 APPLIED LIFE SCIENCES↗

SU-E-T-433: Field-In-Field Irradiation for Breast Cancer with VERO-4DRT System: A Feasibility Study

Purpose: The Vero-4DRT system is a dedicated system for high precision radiation therapy. However, the field size is limited at 15 cm x 15 cm and shapes by using multi-leaf collimator (MLC) without X-Jaw and Y-Jaw. Therefore VERO-4DRT system is not available to simple wedged irradiation for breast cancer. In this study, we suppose FIF with ring and/or tilt/pan angles whole breast irradiation (FIFWBI). The purpose of this study is to verify the feasibility of FIFWBI with VERO-4DRT system. Methods: As fundamental evaluation, we performed commissioning test with phantom. The absorbed dose evaluation at several reference points and dose distribution including split area were performed. We planned 10 demonstrative shapes in phantom for measuring these contents with i-plan workstation (BrainLAB). As clinical evaluation, the dose distribution and dose indexes were evaluated with actual patient data. Five patients with breast cancer were designed FIFWBI radiotherapy plan with split fields. Then, the dose distribution and dose indexes (including Dmax, Dmin, D95, D5 and Homogeneity index) were evaluated in these plans. Results: As the results of fundamental evaluation, all absorbed dose errors between calculated and measured doses were within 2%. The gamma passing rates with 2 mm/3% criteria in all cases were 96±2%. As the results of clinical evaluation, the values of Dmax, D95, D50, D5, and Homogeneity Index were 41.7±0.90 Gy, 49.4±0.34 Gy, 52.26±0.24 Gy, and 1.39±0.03, respectively. For Japanese breast cancer patients, this technique was feasible. However, the large split region was happened in FIFWBI in case of patient with large breast. Conclusion: We evaluated the FIFWBI technique with VERO-4DRT system. This technique is feasible for Japanese patients, but the patient with large breast should be disagreed with this technique.

60 APPLIED LIFE SCIENCES↗

SU-E-T-449: Hippocampal Sparing Radiotherapy Using Intensity Modulated Radiotherapy and Volumetric Modulated Arc Therapy

Purpose: The hippocampus sparing during the cranial irradiation has become interesting because it may mitigate radiation-induced neurocognitive toxicity. Herein we report our preliminary study for sparing the hippocampus with and without tilling condition for patient with brain metastases. Methods: Ten patients previously treated with whole brain were reviewed. Five patients tilted the head to around 30 degrees and others were treated without tilting. Treatment plans of linear accelerator (Linac)-based volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT) were generated for prescription dose of 30 Gy in 15 fractions. Hippocampal avoidance regions were created with 5-mm volumetric expansion around the hippocampus. Whole brain, hippocampus and hippocampal avoidance volume were 1372cm3, 6cm3 and 30cm3 and hippocampal avoidance volume was 2.2% of the whole brain planned target volume in average. Organs at risk (OARs) are hippocampus, eyes, lens, and cochleae. Coverage index (CVI), conformity index (CI), homogeneity index (HI) and mean dose to OARs were used to compare dose characteristic of tilted and non-tilted cases. Results: In IMRT, when CI, CVI and HI of whole brain were 0.88, 0.09 and 0.98 in both tilted and non-tilted cases, absorbed dose of hippocampal avoidance volume in tilted cases were 10% lower than non-tilted cases. Doses in other OARs such as eyes, lens, and cochleae were also decreased about 20% when tilting the head. When CI, HI and CVI in VMAT were 0.9, 0.08 and 0.99, the dose-decreased ratio of OARs in both with and without tilting cases were almost the same with IMRT. But absolute dose of hippocampal avoidance volume in VMAT was 30% lower than IMRT. Conclusion: This study confirms that dose to hippocampus decreases if patients tilt the head. When treating the whole brain with head tilted, patients can acquire the same successful treatment Result and also preserve their valuable memory.

60 APPLIED LIFE SCIENCES↗

SU-E-T-462: Impact of the Radiochromic Film Energy Response On Dose Measurements of Low Energy Electronic Brachytherapy Sources

Purpose: We investigated the effect of the EBT3 GafChromicTM film model absorbed dose energy response when used for percent depth dose (PDD) measurements in low-energy photon beams. Methods: We measured PDDs in water from a Xoft 50 kVp source using EBT3 film, and compared them to PDD measurements acquired with a PTW-TN34013 parallel-plate ionization chamber. For the x-ray source, we simulated spectra using the EGSnrc (BEAMnrc) Monte Carlo code, and calculated Half Value Layer (HVL) at different distances from the source in water. Pieces of EBT3 film were irradiated in air and calibration curves were created in terms of air-kerma in air ((Kair)air) for different beam qualities. Pieces of EBT3 film were positioned at distances of 2–6 cm from the Xoft source in a water phantom using a custom-made holder, and irradiated at the same time. As scatter is incorporated in the measured film signal in water, measured (Kair)wat was subsequently converted into absorbed dose to water by the ratio of mass energy absorption coefficients following the AAPM TG-61 dosimetry protocol. Results: Our results show that film calibration curves obtained at beam qualities near the effective energy of the Xoft 50 kVp source in water lead to variation in absorbed dose energy dependence of the response of around 3%. However, if the calibration curve was established at MV beam quality, the error in absorbed dose could be as large as 15%. We observed agreement within 1% between PDD measurements using EBT3 film model (using a calibration curve obtained at 80 kVp, HVL=2.18 mm Al, Eeff=29.5 keV) and the parallel-plate ionization chamber. Conclusion: Accurate dose measurements using radiochromic films at low photon energies require that the radiochromic film dosimetry system be calibrated at corresponding low energies, as large absorbed dose errors are expected for calibrations performed at MV beam qualities.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-481: In Vivo and Post Mortem Animal Irradiation: Measured Vs. Calculated Doses

Purpose: Computerized radiation therapy treatment planning is performed on almost all patients today. However it is seldom used for laboratory irradiations. The first objective is to assess whether modern radiation therapy treatment planning (RTP) systems accurately predict the subject dose by comparing in vivo and decedent dose measurements to calculated doses. The other objective is determine the importance of using a RTP system for laboratory irradiations. Methods: 5 MOSFET radiation dosimeters were placed enterically in each subject (2 sedated Rhesus Macaques) to measure the absorbed dose at 5 levels (carina, lung, heart, liver and rectum) during whole body irradiation. The subjects were treated with large opposed lateral fields and extended distances to cover the entire subject using a Varian 600C linac. CT simulation was performed ante-mortem (AM) and post-mortem (PM). To compare AM and PM doses, calculation points were placed at the location of each dosimeter in the treatment plan. The measured results were compared to the results using Varian Eclipse and Prowess Panther RTP systems. Results: The Varian and Prowess treatment planning system agreed to within in +1.5% for both subjects. However there were significant differences between the measured and calculated doses. For both animals the calculated central axis dose was higher than prescribed by 3–5%. This was caused in part by inaccurate measurement of animal thickness at the time of irradiation. For one subject the doses ranged from 4% to 7% high and the other subject the doses ranged 7% to 14% high when compared to the RTP doses. Conclusions: Our results suggest that using proper CT RTP system can more accurately deliver the prescribed dose to laboratory subjects. It also shows that there is significant dose variation in such subjects when inhomogeneities are not considered in the planning process.

60 APPLIED LIFE SCIENCES↗

SU-E-T-499: Initial Developments of An OpenCL-Based Cross-Platform Monte Carlo Dose Engine for Carbon Ion Therapy

Purpose Dose calculation is of critical importance for carbon ion therapy. Monte Carlo (MC) simulation is considered to be the most accurate method for calculation of absorbed dose and of all the more fundamental physical quantities related to biological effects. The long computation time, however, limits its routine clinical applications. We have recently started developing a fast MC package, gCMC for carbon therapy on a parallel processing platform, e.g. GPU, aiming at achieving sufficient efficiency to enable MC in clinically important tasks. This abstract reports our progress. Methods gCMC was developed in OpenCL environment. Our initial developments focused on water material. gCMC supported carbon ion transport in the energy range of 1–450 MeV/u. A Class II condensed history algorithm was implemented for charged particle transport simulations with stopping power computed via Bethe-Bloch equation. Energy straggling and multiple scattering were modeled. Total cross section of nuclear interaction was extracted from Geant4. At present, nuclear interaction events were sampled but transports of secondary particles were not included. Results We tested cases with a homogeneous water phantom and a pencil carbon ion beam with energy of 200–400 MeV/u. When only electro-magnetic channel was included, dose/fluence difference between gCMC and Geant4 results averaged within 10% isodose line was <0.5% of the maximum dose/fluence. After enabling nuclear interactions without transporting secondary particles, dose and fluence agreed with the corresponding results computed by Geant4 with <1% difference. Due to the support for multiple platforms of OpenCL, gCMC was executable on NVidia and AMD GPUs, and Intel CPUs. It took ∼50 sec to transport 107 200MeV/u source carbon ions on an NVidia Titan GPU card. Conclusion Preliminary studies have demonstrated the accuracy and efficiency of gCMC. With further developments in near future, gCMC will potentially achieve clinically acceptable fast and accurate MC simulations for carbon ion therapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-507: Internal Dosimetry in Nuclear Medicine Using GATE and XCAT Phantom: A Simulation Study

Purpose Monte Carlo simulations are routinely used for internal dosimetry studies. These studies are conducted with humanoid phantoms such as the XCAT phantom. In this abstract we present the absorbed doses for various pairs of source and target organs using three common radiotracers in nuclear medicine. Methods The GATE software package is used for the Monte Carlo simulations. A typical female XCAT phantom is used as the input. Three radiotracers 153Sm, 131I and 99mTc are studied. The Specific Absorbed Fraction (SAF) for gamma rays (99mTc, 153Sm and 131I) and Specific Fraction (SF) for beta particles (153Sm and 131I) are calculated for all 100 pairs of source target organs including brain, liver, lung, pancreas, kidney, adrenal, spleen, rib bone, bladder and ovaries. Results The source organs themselves gain the highest absorbed dose as compared to other organs. The dose is found to be inversely proportional to distance from the source organ. In SAF results of 153Sm, when the source organ is lung, the rib bone, gain 0.0730 (Kg-1) that is more than lung itself. Conclusion The absorbed dose for various organs was studied in terms of SAF and SF. Such studies hold importance for future therapeutic procedures and optimization of induced radiotracer.

60 APPLIED LIFE SCIENCES↗

SU-E-T-526: Irradiation of Human Cell Lines Using Carbon Ions: Real Time Dosimetry Using Gaf-Chromic Film

Purpose: The purpose of this study is to investigate and quantify several factors affecting biological effects of carbon ions such as cell type, dose, energy and position where the cells are irradiated along the pristine Bragg curve. Methods: Experiments to quantify clonogenic cell survival in three human lung cancer cell lines and a fibroblast cell line were performed at the NASA Space Radiation Laboratory, BNL, Upton, USA. A system of water or media-filled T25 flasks lined up along the beam axis was designed so that the cell-containing surfaces of the flasks were placed at specific depths along the Bragg curve. Gaf-chromic films were placed between the flasks to monitor the dose distribution in the sample as soon as the irradiation was finished. Additional studies were conducted at four selected depths along the Bragg curve to obtain full cell survival dose response curves for the four cell lines. Results: The percent depth dose of the beams was determined using an ionization chamber and showed that the physical Bragg peak is at 22.5 cm water depth. However, the clonogenic cell survival data indicated that the maximum cell killing occurred at 21.5 cm. Gaf-chromic films revealed some inhomogeneity in the dose distribution on the flasks near the peak, presumably due to lack of scattering from the sides of the flasks, which might account for the differences. Depending on the cell line and radiation dose, the maximum cell killing (i.e., the greatest RBE) is at the 21.5 (the peak) or 24 cm (distal fall off) depth. Conclusion: There is a difference in biological effect along the Bragg curve of a carbon ion beam, indicating an elevated RBE at or beyond the end of the range. Gaf-chromic films are proven to be effective in monitoring the 2D irradiation pattern to the flasks. Research supported by NIH/NCI through grant no. R21 CA182259.

60 APPLIED LIFE SCIENCES↗

SU-E-T-753: Three-Dimensional Dose Distributions of Incident Proton Particle in the Polymer Gel Dosimeter and the Radiochromic Gel Dosimeter: A Simulation Study with MCNP Code

Purpose: The purpose of this study is to estimate the three-dimensional dose distributions in the polymer and the radiochromic gel dosimeter, and to identify the detectability of both gel dosimeters by comparing with the water phantom in case of irradiating the proton particles. Methods: The normoxic polymer gel and the LCV micelle radiochromic gel were used in this study. The densities of polymer and the radiochromic gel dosimeter were 1.024 and 1.005 g/cm{sup 3}, respectively. The dose distributions of protons in the polymer and radiochromic gel were simulated using Monte Carlo radiation transport code (MCNPX, Los Alamos National Laboratory). The shape of phantom irradiated by proton particles was a hexahedron with the dimension of 12.4 × 12.4 × 15.0 cm{sup 3}. The energies of proton beam were 50, 80, and 140 MeV energies were directed to top of the surface of phantom. The cross-sectional view of proton dose distribution in both gel dosimeters was estimated with the water phantom and evaluated by the gamma evaluation method. In addition, the absorbed dose(Gy) was also calculated for evaluating the proton detectability. Results: The evaluation results show that dose distributions in both gel dosimeters at intermediated section and Bragg-peak region are similar with that of the water phantom. At entrance section, however, inconsistencies of dose distribution are represented, compared with water. The relative absorbed doses in radiochromic and polymer gel dosimeter were represented to be 0.47 % and 2.26 % difference, respectively. These results show that the radiochromic gel dosimeter was better matched than the water phantom in the absorbed dose evaluation. Conclusion: The polymer and the radiochromic gel dosimeter show similar characteristics in dose distributions for the proton beams at intermediate section and Bragg-peak region. Moreover the calculated absorbed dose in both gel dosimeters represents similar tendency by comparing with that in water phantom.

60 APPLIED LIFE SCIENCES↗

SU-E-T-782: Using Light Output From Doped Plastic Scintillators to Resolve the Linear Energy Transfer Spectrum of Clinical Electron Beams

Purpose: This research seeks to develop a portable, clinically-suitable linear energy transfer (LET) detector. In radiotherapy, absorbed dose is commonly used to measure the amount of delivered radiation, though, it is not a good indicator of actual biological damage. LET is the energy absorbed per unit length by a medium along charged particle’s pathway; studies have shown that LET correlates well with relative biological effectiveness (RBE). Methods: According to Birks’ law, light output of plastic scintillators is stopping-power dependent. This dependency can be varied through doping by various high-Z elements. By measuring light output signals of differently doped plastic scintillators (represented by column vector S, where each row corresponds to different scintillator material), the fluence of charged particles of a given LET (represented by column vector Φ, where each row corresponds to different LET bins) can be unfolded by S=R*Φ where R is system response matrix (each row represents a different scintillator, each column corresponds to different electron LET). Monte Carlo (MC) GEANT4.10.1 was used to evaluate ideal detector response of BC408 scintillating material doped with various concentrations of several high Z dopants. Measurements were performed to validate MC. Results: Signal for 1%-lead doped BC408 and the non-doped scintillator was measured experimentally by guiding light emitted by the scintillator (via in-house made taper, fiber system) to a PMT and then an electrometer. Simulations of 1%Pb-doped scintillator to non-doped scintillator revealed 9.3% reduction in light output for 6 MeV electrons which compared well (within uncertainty) with measurements showing 10% reduction (6MeV electrons). Conclusion: Measurements were used to validate MC simulation of light output from doped scintillators. The doping of scintillators is a viable technique to induce LET dependence. Our goal is to use this effect to resolve the LET spectrum of an incident beam.

60 APPLIED LIFE SCIENCES↗