Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

(U) Endpoint Energy and Scintillator Geometry Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy Radiography

High-energy radiography is used to image imploding materials to better understand weapon design and performance. The Enhanced Capabilities for Subcritical Experiments (ECSE) is a new facility proposal that aims to collect radiographic images of nuclear material. As part of the facility design, we aim to optimize data quality and radiographic performance by investigating different detector designs. We addressed design decisions by simulating different scintillator designs using M CNP6 and calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(O)). First, we investigated the effects of the x-ray endpoint energy on the detector response. We generated three x-ray spectra with endpoint energies of 20 MeV, 22 MeV, and 24 MeV. The three raw spectra were filtered using the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) line-of-sight materials along with 1) flat field filtration using 7 cm tungsten alloy in the bullnose and 2) an FTO with 4 plates. The scatter-to-direct radiation ratio was much larger for FTO with 4 plates (50-60%) compared to the flat field with 7 cm of bullnose material (8%). We used these filtered spectra to calculate the detector response for the original DARHT segmented scintillator design. We found that the endpoint energy and filtration had a negligible effect on the detector response. The quantum efficiency was 0.63, the Swank factor was 0.84, and the DQE(O) was 0.53 for all six spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of a Loss of Coolant Blowdown Capsule for Remote Assembly with High Burnup Fuel

The Transient Water Irradiation System is an enhanced capability capsule type irradiation vehicle designed to support fuel safety research for light water reactor specimens in the Transient Reactor Test Facility and is designed to simulate loss of coolant and reactivity-initiated accidents. The capsule was designed, deployed, and commissioned with fresh fuel specimens to validate instrumentation and prepare for previously irradiated high burnup specimens. The irradiation system features an extensive in-situ instrumentation package to detect phenomena typical to light water reactor fuels. To accommodate the assembly with high burnup specimens inside the Hot Fuel Examination Facility, and to ensure instrumentation integrity is maintained throughout assembly, the design was updated to support remote handling. The updated design features a hinge mechanism which allows for remote pre-irradiated specimen loading and assembly while protecting sensitive instrumentation by relocating during loading. Fixtures and equipment have been developed to handle the experiment capsule and components in cell, and to support remote assembly. The experiment module also includes radiation shielding and contamination control to support operations after removal from the hot cell.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Alpha Spectrometry Results for Groundwater Samples Collected in Northern Iraq and a Summary of the Environmental Setting of the Adaya Burial Site

The Radiation Protection Center (RPC) of the Iraqi Ministry of Environment continues to evaluate the potential health impacts associated with the Adaya Burial Site, which is located 33 kilometers (20.5 miles) southwest of Mosul. This report documents the radiological analyses of 16 groundwater samples collected from wells located in the vicinity of the Adaya Burial Site and at other sites in northern Iraq. The Adaya Burial Site is a high-risk dump site because a large volume of radioactive material and contaminated soil is located on an unsecure hillside above the village of Tall ar Ragrag. The uranium activities for the 16 water samples in northern Iraq are considered to be naturally occurring and do not indicate artificial (man-made) contamination. With one exception, the alpha spectrometry results for the 16 wells that were sampled in 2019 indicate that the water quality concerning the three uranium isotopes (Uranium-233/234, Uranium-235/236, and Uranium-238) was acceptable for potable purposes (drinking and cooking). However, Well 7 in Mosul had a Uranium-233/234 activity concentration that slightly exceeded the World Health Organization guidance level. Eight of the 16 wells are located in the villages of Tall ar Ragrag and Adaya and had naturally occurring uranium concentrations. Wells in the villages of Tall ar Ragrag and Adaya are located near the Adaya Burial Site and should be sampled on an annual schedule. The list of groundwater analytes should include metals, total uranium, isotopic uranium, gross alpha/beta, gamma spectroscopy, organic compounds, and standard water quality parameters. Our current understanding of the hydrogeologic setting in the vicinity of the Adaya Burial Site is solely based on villager's domestic wells, topographic maps, and satellite imagery. To better understand the hydrogeologic setting, a Groundwater Monitoring Program needs to be developed and should include the installation of twelve groundwater monitoring wells in the vicinity of Tall ar Ragrag and the Adaya Burial Site. Characterization of the limestone aquifer and overlying alluvium is needed. RPC should continue to support health assessments for the villagers in Tall ar Ragrag and Adaya. Collecting samples for surface water (storm water), airborne dust, vegetation, and washway sediment should be conducted on a routine basis. Human access to the Adaya Burial Site needs to be strictly limited. Livestock access on or near the burial site needs to be eliminated. The surface-water exposure pathway is likely a greater threat than the groundwater exposure pathway. Installation of a surface-water diversion or collection system is recommended in order to reduce the potential for humans and livestock to come in contact with contaminated water and sediment. To reduce exposure to villagers, groundwater treatment should be considered if elevated uranium or other contaminants are detected in drinking water. Installing water-treatment systems would likely be quicker to accomplish than remediation and excavation of the Adaya Burial Site. The known potential for human exposure to uranium and metals (such as arsenic, chromium, selenium, and strontium) at the Adaya Burial Site is serious. Additional characterization , mitigation, and remediation efforts should be given a high priority.

54 ENVIRONMENTAL SCIENCES↗

Collaborative Research Activities of the Arase and Van Allen Probes

This paper presents the highlights of joint observations of the inner magnetosphere by the Arase spacecraft, the Van Allen Probes spacecraft, and ground-based experiments integrated into spacecraft programs. The concurrent operation of the two missions in 2017–2019 facilitated the separation of the spatial and temporal structures of dynamic phenomena occurring in the inner magnetosphere. Because the orbital inclination angle of Arase is larger than that of Van Allen Probes, Arase collected observations at higher L-shells up to L ~ 10. After March 2017, similar variations in plasma and waves were detected by Van Allen Probes and Arase. We describe plasma wave observations at longitudinally separated locations in space and geomagnetically-conjugate locations in space and on the ground. The results of instrument intercalibrations between the two missions are also presented. Arase continued its normal operation after the scientific operation of Van Allen Probes completed in October 2019. The combined Van Allen Probes (2012-2019) and Arase (2017-present) observations will cover a full solar cycle. This will be the first comprehensive long-term observation of the inner magnetosphere and radiation belts.

97 MATHEMATICS AND COMPUTING↗

LLNL FY22 Aging and Lifetimes Exit Criteria: Milestone 8119, GC#01

Polysiloxane foams utilized for stockpile applications experience changes over time induced by exposure to thermal, radiative, and mechanical stresses. The interplay of these stresses can lead to chemical and/or physical changes in the polymer, such as compression set and material degradation over time. Understanding the mechanisms of material aging and identifying material degradation prior to failure are critical in maintaining the integrity of the nuclear stockpile. Our prior work using solid-state NMR spectroscopy has shown that we can observe signatures of thermal, radiative, and mechanical aging of silicone elastomers using differences in NMR parameters such as relaxation (T1 and T2). However, most of our measurements have been on bulk samples and have only provided an average aging behavior of each sample. Here, we have used magnetic resonance imaging (MRI) to provide relaxation-weighted images that are a metric of structural heterogeneity (crosslink density) in polymers across multiple length scales. In addition, the larger sample size that can be accommodated in animal MRI scanners has the potential to make the technique adaptable to detecting heterogeneities in whole parts.

36 MATERIALS SCIENCE↗

Stacked CMB lensing and ISW signals around superstructures in the DESI Legacy Survey

The imprints of large-scale structures on the Cosmic Microwave Background (CMB) can be studied via the CMB lensing and Integrated Sachs–Wolfe (ISW) signals. In particular, the stacked ISW signal around supervoids has been claimed in several works to be anomalously high. In this study, we find cluster and void superstructures using four tomographic redshift bins with 0 < z < 0.8 from the DESI Legacy Survey and measure the stacked CMB lensing and ISW signals around them. To compare our measurements with ΛCDM model predictions, we construct a mock catalogue with matched galaxy number density and bias and apply the same photo-z uncertainty as the data. The consistency between the mock and the data is verified via the stacked galaxy density profiles around the superstructures and their quantity. The corresponding lensing convergence and ISW maps are then constructed and compared. The stacked lensing signal agrees with data well except at the highest redshift bin in density peaks, where the mock prediction is significantly higher, by approximately a factor of 1.3. The stacked ISW signal is generally consistent with the mock prediction. We do not obtain a significant signal from voids, A ISW = -0.10 ± 0.69, and the signal from clusters, A ISW = 1.52 ± 0.72, is at best weakly detected. However, these results are strongly inconsistent with previous claims of ISW signals at many times the level of the ΛCDM prediction. We discuss the comparison of our results with past work in this area and investigate possible explanations for this discrepancy.

79 ASTRONOMY AND ASTROPHYSICS↗

Interface Modes in Inspiralling Neutron Stars: A Gravitational-Wave Probe of First-Order Phase Transitions

At the extreme densities in neutron stars, a phase transition to deconfined quark matter is anticipated. Yet masses, radii, and tidal deformabilities offer only indirect measures of a first-order phase transition, requiring many detections to resolve or being ineffective observables if the discontinuity exists at lower densities. Here, we report on a smoking-gun gravitational-wave signature of a first-order transition: the resonant tidal excitation of an interface mode. Using relativistic perturbation theory with an equation-of-state family informed by chiral effective field theory, we show that such a resonance may be detectable with next-generation interferometers and possibly already with LIGO A+ for sufficiently loud events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

2020 State of the Science Report, Chapter 4: Risk to Marine Animals from Underwater Noise Generated by Marine Renewable Energy Devices

In all ocean environments, desirable locations for wave and tidal energy development have multiple natural sources of sound (e.g., waves, wind, and sediment transport), varying levels of anthropogenic and biological noise, and measurement quality challenges (e.g., flow-noise, self-noise). Many marine animals rely on sound for biological functions, including communication, social interaction, orientation, foraging, and evasion. The extent to which marine animals detect and produce sound varies by frequency (spanning roughly four decades from 10 Hz to 100 kHz) and is taxa-specific. Because of the relatively limited data available, hearing sensitivity is often generalized to taxonomic groups (e.g., cetaceans that have low-frequency hearing specialization). https://tethys.pnnl.gov/publications/state-of-the-science-2020-chapter-4-underwater-noise

54 ENVIRONMENTAL SCIENCES↗

Quantum Imaging with X-rays

Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.

Gofron, Kaz [ORNL] (ORCID:0000000314415736)↗

Implementation of Stochastic Gradient Descent in an Automated Glow Peak Identification Software for Multiple Thermoluminescent Dosimeter Types

A glow-curve analysis code was previously developed in C++ to analyze thermoluminescent dosimeter glow curves using automated peak detection while applying a first-order kinetics model. A newer version of this code was implemented to improve the automated peak detection and curve fitting models. The Stochastic Gradient Descent Algorithm was introduced to replace the prior approach of taking first and second-order derivatives for peak detection. Additionally, early stopping mechanisms were invoked to improve the previously used Levenberg-Marquardt Algorithm employed for curve fitting. The two software versions were compared through glow curve analysis of different thermoluminescent dosimeter materials and calculation of the corresponding figures of merit. Altogether improvements were shown, namely an increase in the number of peaks detected and a reduction of the mean figure of merit by approximately 46%.

137Cs↗

MeV-scale performance of water-based and pure liquid scintillator detectors

This paper presents studies of the performance of water-based liquid scintillators (WbLS) in both 1-kt and 50-kt detectors. In this work, performance is evaluated in comparison to both pure water Cherenkov detectors and a nominal model for pure scintillator detectors. Performance metrics include energy, vertex, and angular resolution, along with a metric for the ability to separate the Cherenkov from the scintillation signal as being representative of various particle identification capabilities that depend on the Cherenkov/scintillation ratio. We also modify the time profile of scintillation light to study the same performance metrics as a function of rise and decay time. We go on to interpret these results in terms of their impact on certain physics goals, such as solar neutrinos and the search for Majorana neutrinos. This work supports and validates previous results, and the assumptions made therein, and serves as a significant stepping stone to complete detector design studies by using a more detailed detector model and full reconstruction, with a primarily data-driven optical model, and fewer model assumptions. With this model, a high-coverage 50-kt detector achieves better than 10 (1)% precision on the flux of neutrinos from the Carbon-Nitrogen-Oxygen cycle with a water-based liquid scintillator (pure LS) target in five years of data taking. A 1-kt LS detector, with a conservative 50% fiducial volume of 0.5 kt, can achieve better than 5% detection. A liquid scintillator detector has sensitivity into the normal hierarchy region for Majorana neutrinos with half-life sensitivity of $T^{0νββ}_{1/2}$ > 1.4 × 10 28 years at 90% C.L. for 10 years of data taking with a Te-loaded target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electric Field Imaging Using Polarized Neutrons

In this paper, we experimentally demonstrate that electrically neutral particles, neutrons, can be used to directly visualize the electrostatic field inside a target volume that can be physically isolated or occupied. Electric field images are obtained using a spin-polarized neutron beam with a recently developed polarimetry method for polychromatic beams that permits detection of a small angular change in spin orientation. This work may enable a new diagnostic technique sensitive to the structure of electric potential, electric polarization, charge distribution, and dielectric constant by imaging spatially dependent electric fields in objects that cannot be accessed by other probes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Resonant Metamaterial Line Array for Ultrasound Compressive Imaging

Abstract Acoustic metamaterials have been proposed for numerous applications including subwavelength imaging, impedance matching, and lensing. Yet, their application in compressive sensing and imaging has not been fully investigated. When metamaterials are used as resonators at certain frequencies, they can generate random radiation patterns in the transmitted waves from the transducers and received waves from a target. Compressive sensing favors such randomness inasmuch as it can increase incoherence by decreasing the amount of mutual information between any two different measurements. This study aims at assessing whether the use of resonating metamaterial unit cells in a single-layered non-optimized array between a number of ultrasound transceivers and targets can improve the sensing capacity, point-spread function of the sensing array (their beam focusing ability), and imaging performance in point-like target detection. The theoretical results are promising and can open the way for more efficient metamaterial designs with the aim of enhancing ultrasound imaging with lower number of transceivers compared to the regular systems.

Acoustics↗

Isotope-selective radiography and material assay using high-brilliance, quasi-monochromatic, high-energy photons

We demonstrate the possibility to directly detect microgram amounts of the isotope 7 Li using a quasi-monochromatic high-energy photon beam. The isotope selective detection is based on a witness scatterer absorbing and re-emitting photons via nuclear resonance fluorescence. This enables the detection of isotopes with microgram accuracy at long distances from the actual sample. Further, we demonstrate that the technique can deliver quantitative information without specific knowledge of the photon flux and no spectral capabilities or knowledge of the resonance fluorescence cross section. Detection of low-atomic-weight isotopes screened by heavy shielding is also shown. The techniques described are applicable to all next-generation, ultrahigh brilliance, laser-Compton light sources currently under construction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aging and Lifetimes Milestone 7777, G.C. #4: Assess the ability of MRI to identify chemical and mechanical heterogeneity in polymers at various length scales

Polysiloxane foams utilized for stockpile applications experience changes over time induced by exposure to thermal, radiative, and mechanical stresses. The interplay of these stresses can lead to chemical and/or physical changes in the polymer, such as compression set and material degradation over time. Understanding the mechanisms of material aging and identifying material degradation prior to failure are critical in maintaining the integrity of the nuclear stockpile. Our prior work using solid-state NMR spectroscopy has shown that we can observe signatures of thermal, radiative, and mechanical aging of silicone elastomers using differences in NMR parameters such as relaxation (T1 and T2). However, most of our measurements have been on bulk samples and have only provided an average aging behavior of each sample. Here, we have used magnetic resonance imaging (MRI) to provide relaxation-weighted images that are a metric of structural heterogeneity (cross-link density) in polymers across multiple length scales. In addition, the larger sample size that can be accommodated in animal MRI scanners has the potential to make the technique adaptable to detecting heterogeneities whole parts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sawfly Genomes Reveal Evolutionary Acquisitions That Fostered the Mega-Radiation of Parasitoid and Eusocial Hymenoptera

The tremendous diversity of Hymenoptera is commonly attributed to the evolution of parasitoidism in the last common ancestor of parasitoid sawflies (Orussidae) and wasp-waisted Hymenoptera (Apocrita). However, Apocrita and Orussidae differ dramatically in their species richness, indicating that the diversification of Apocrita was promoted by additional traits. These traits have remained elusive due to a paucity of sawfly genome sequences, in particular those of parasitoid sawflies. Here, we present comparative analyses of draft genomes of the primarily phytophagous sawfly Athalia rosae and the parasitoid sawfly Orussus abietinus. Our analyses revealed that the ancestral hymenopteran genome exhibited traits that were previously considered unique to eusocial Apocrita (e.g., low transposable element content and activity) and a wider gene repertoire than previously thought (e.g., genes for CO 2 detection). Moreover, we discovered that Apocrita evolved a significantly larger array of odorant receptors than sawflies, which could be relevant to the remarkable diversification of Apocrita by enabling efficient detection and reliable identification of hosts.

59 BASIC BIOLOGICAL SCIENCES↗

Improving Fission Products at CARIBU: Near Field Detection (Q2/FY23 Quarterly Progress Report)

We continue work on the 111 Ag analysis which is currently close to being complete. We received referee comments after submission of the mass measurement results for 128 Sb to Phys. Rev. Lett. And we are currently working on addressing them. The report summarizing the results for the branching ratios of 156 Eu (our previous measurement) was submitted to WebPMIS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗