Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Newly found evidence of Sun-climate relationships

Solar radiation cycles drive climatic changes intercyclically. These interdecadal changes were detected as variations in solar total irradiances over the time period of recorded global surface-air-temperature (SAT) and have been restored utilizing Earth Radiation Budget Channel 10C measurements (1978-1990), Greenwich Observatory faculae data (1874-1975), and Taipei Observatory Active Region data (1964-1991). Analysis of the two separate events was carried out by treating each as a discrete time series determined by the length of each solar cycle. The results show that the global SAT responded closely to the input of solar cyclical activities, S, with a quantitative relation of T = 1.62 * S with a correlation coefficient of 0.61. This correlation peaks at 0.71 with a built-in time lag of 32 months in temperature response. Solar forcing in interannual time scale was also detected and the derived relationship of T = 0.17 * S with a correlation coefficient of 0.66 was observed. Our analysis shows derived climate sensitivities approximately fit the theoretical feedback slope, 4T(sup 3).

Kim, Hongsuk H.↗

Leveraging Quantum Sensors for Dark Matter Detection

Recent measurements have demonstrated that superconducting qubit decoherence is affected by radiation. As a result, many groups around the world are working to better understand the relationship between different types of radiation and qubit response. This crucial to quantum error correction because radiation can cause correlated loss of information across multiple qubits on a chip, defeating error correction algorithms. Additionally, the fundamental energy scale at which superconducting qubits operate may enable their development as meV-scale detectors for HEP applications, such as the direct detection of dark matter. At Fermilab, we have two world-class underground facilities which are already being used to study this problem: NEXUS and QUIET. I will present on results from operating superconducting qubits in each of these facilities, and the potential implications towards utilizing qubits as sensors for a novel dark matter detector.

Baxter, Daniel [Texas U., Arlington]↗

Leveraging Quantum Sensors for Dark Matter Detection

Recent measurements have demonstrated that superconducting qubit decoherence is affected by radiation. As a result, many groups around the world are working to better understand the relationship between different types of radiation and qubit response. This crucial to quantum error correction because radiation can cause correlated loss of information across multiple qubits on a chip, defeating error correction algorithms. Additionally, the fundamental energy scale at which superconducting qubits operate may enable their development as meV-scale detectors for HEP applications, such as the direct detection of dark matter. At Fermilab, we have two world-class underground facilities which are already being used to study this problem: NEXUS and QUIET. I will present on results from operating superconducting qubits in each of these facilities, and the potential implications towards utilizing qubits as sensors for a novel dark matter detector.

Baxter, Daniel [Texas U., Arlington]↗

Cosmology of dark energy radiation

In this work, we quantify the cosmological signatures of dark energy radiation—a novel description of dark energy, which proposes that the dynamical component of dark energy is comprised of a thermal bath of relativistic particles sourced by thermal friction from a slowly rolling scalar field. For a minimal model with particle production emerging from first principles, we find that the abundance of radiation sourced by dark energy can be as large as Ω DER = 0.03, exceeding the bounds on relic dark radiation by three orders of magnitude. Although the background and perturbative evolution of dark energy radiation are distinct from Quintessence, we find that current and near-future cosmic microwave background and supernova data will not distinguish these models of dark energy. We also find that our constraints on all models are dominated by their impact on the expansion rate of the Universe. Considering extensions that allow the dark radiation to populate neutrinos, axions, and dark photons, we evaluate the direct detection prospects of a thermal background comprised of these candidates consistent with cosmological constraints on dark energy radiation. Our study indicates that a resolution of ~6 meV is required to achieve sensitivity to relativistic neutrinos compatible with dark energy radiation in a neutrino capture experiment on tritium. We also find that dark matter axion experiments lack sensitivity to a relativistic thermal axion background, even if enhanced by dark energy radiation, and dedicated search strategies are required to probe new parameter space. We derive constraints arising from a dark photon background from oscillations into visible photons, and find that viable parameter space can be explored with the late dark energy radiation experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Isotopic Ratios of Carbon and Oxygen in Titan's CO Using Alma

We report interferometric observations of carbon monoxide (CO) and its isotopologues in Titan's atmosphere using the Atacama Large Millimeter/submillimeter Array (ALMA). The following transitions were detected: CO (J = 1-0, 2-1, 3-2, 6-5), C-13 O (J = 2-1, 3-2, 6-5), C-18 O (J = 2-1, 3-2), and C-17 O (J = 3-2). Molecular abundances and the vertical atmospheric temperature profile were derived by modeling the observed emission line profiles using NEMESIS, a line-by-line radiative transfer code. We present the first spectroscopic detection of O-17 in the outer solar system with C-17 O detected at greater than 8 sigma confidence. The abundance of CO was determined to be 49.6 +/- 1.8 ppm, assumed to be constant with altitude, with isotopic ratios C-12/C-13 = 89.9 +/- 3.4, O-16/O-18 = 486 +/- 22, and O-16/O-17 = 2917 +/- 359. The measurements of C-12/C-13 and O-16/O-18 ratios are the most precise values obtained in Titan's atmospheric CO to date. Our results are in good agreement with previous studies and suggest no significant deviations from standard terrestrial isotopic ratios.

Serigano, Joseph↗

Space Shuttle Main Engine Propellant Path Leak Detection Using Sequential Image Processing

Initial research in this study using theoretical radiation transport models established that the occurrence of a leak is accompanies by a sudden but sustained change in intensity in a given region of an image. In this phase, temporal processing of video images on a frame-by-frame basis was used to detect leaks within a given field of view. The leak detection algorithm developed in this study consists of a digital highpass filter cascaded with a moving average filter. The absolute value of the resulting discrete sequence is then taken and compared to a threshold value to produce the binary leak/no leak decision at each point in the image. Alternatively, averaging over the full frame of the output image produces a single time-varying mean value estimate that is indicative of the intensity and extent of a leak. Laboratory experiments were conducted in which artificially created leaks on a simulated SSME background were produced and recorded from a visible wavelength video camera. This data was processed frame-by-frame over the time interval of interest using an image processor implementation of the leak detection algorithm. In addition, a 20 second video sequence of an actual SSME failure was analyzed using this technique. The resulting output image sequences and plots of the full frame mean value versus time verify the effectiveness of the system.

Smith, L. Montgomery↗

SSME Propellant Path Leak Detection

The complicated high-pressure cycle of the space shuttle main engine (SSME) propellant path provides many opportunities for external propellant path leaks while the engine is running. This mode of engine failure may be detected and analyzed with sufficient speed to save critical engine test hardware from destruction. The leaks indicate hardware failures which will damage or destroy an engine if undetected; therefore, detection of both cryogenic and hot gas leaks is the objective of this investigation. The primary objective of this phase of the investigation is the experimental validation of techniques for detecting and analyzing propellant path external leaks which have a high probability of occurring on the SSME. The selection of candidate detection methods requires a good analytic model for leak plumes which would develop from external leaks and an understanding of radiation transfer through the leak plume. One advanced propellant path leak detection technique is obtained by using state-of-the-art technology infrared (IR) thermal imaging systems combined with computer, digital image processing, and expert systems for the engine protection. The feasibility of IR leak plume detection is evaluated on subscale simulated laboratory plumes to determine sensitivity, signal to noise, and general suitability for the application.

Roger Crawford↗

Novel Methods to Produce an Argon-37 Standard

The purpose of this research was to produce a measurable quantity of radioactive argon-37 through photonuclear production methods. The detection of argon-37, above background levels, uniquely and clearly indicates the underground detonation of a nuclear device.

07 ISOTOPE AND RADIATION SOURCES↗

Results from the energetic gamma-ray experiment telescope on the Compton gamma-ray observatory

The energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory (CGRO) has the capability of exploring the high energy plasma gamma ray range from approximately 30 MeV to 30 GeV with a sensitivity considerably greater than earlier gamma-ray satellite telescopes. The dominant radiation from the high energy gamma ray sky is the diffuse radiation along the galactic plane. Thus far, five pulsars have been detected and their properties measured. The high energy gamma rays appear to be an increasing fraction of the total emitted electromagnetic radiation as the age of the pulsar increases up to one million years. Observations of one solar flare event showed that there was strong evidence for long-term trapping of relativistic solar nuclei in the solar vicinity for at least 10 hours. Regarding the gamma ray bursts of unknown origin, high energy gamma rays have been seen following a burst for over an hour, with energies in the GeV range and even higher in the case of two individual gamma rays. The observation of the Small Magellanic Cloud appears to answer finally the long open question of whether the bulk of the cosmic rays are galactic or pervade some much larger volume on the side of their being galactic. Over 30 Active Galactic Nuclei (AGN's) have been seen in high energy gamma rays with high probability thus far including quasars and BL Lac objects, but no Seyfert galaxies. Time variations have been detected in many of these AGN's.

Fichtel, C. E.↗

Non-destructive, in-situ evaluation of water presence using thermal contrast and cooled detector

Exemplary systems for detecting water include: a light source positioned to transmit thermal radiation through a sample; a lens assembly positioned to: receive the thermal radiation transmitted through the sample; and focus the transmitted thermal radiation onto a filter positioned between the lens assembly and a detector; and a cooling subsystem for cooling the filter and the detector to a temperature below that of the sample. The filter (1) selectively transmits first portions of the thermal radiation received from the lens assembly and characterized by a wavelength at least partially overlapping a predefined water absorption band and/or a predefined water absorption line; and (2) selectively blocks second portions of the thermal radiation received from the lens assembly and characterized by a wavelength outside the predefined water absorption band and/or the predefined water absorption line. Methods for detecting presence of water in a sample are also disclosed.

Bora, Mihail↗

SNM Radiation Signature Classification Using Different Semi-Supervised Machine Learning Models

The timely detection of special nuclear material (SNM) transfers between nuclear facilities is an important monitoring objective in nuclear nonproliferation. Persistent monitoring enabled by successful detection and characterization of radiological material movements could greatly enhance the nuclear nonproliferation mission in a range of applications. Supervised machine learning can be used to signal detections when material is present if a model is trained on sufficient volumes of labeled measurements. However, the nuclear monitoring data needed to train robust machine learning models can be costly to label since radiation spectra may require strict scrutiny for characterization. Therefore, this work investigates the application of semi-supervised learning to utilize both labeled and unlabeled data. As a demonstration experiment, radiation measurements from sodium iodide (NaI) detectors are provided by the Multi-Informatics for Nuclear Operating Scenarios (MINOS) venture at Oak Ridge National Laboratory (ORNL) as sample data. Anomalous measurements are identified using a method of statistical hypothesis testing. After background estimation, an energy-dependent spectroscopic analysis is used to characterize an anomaly based on its radiation signatures. In the absence of ground-truth information, a labeling heuristic provides data necessary for training and testing machine learning models. Supervised logistic regression serves as a baseline to compare three semi-supervised machine learning models: co-training, label propagation, and a convolutional neural network (CNN). In each case, the semi-supervised models outperform logistic regression, suggesting that unlabeled data can be valuable when training and demonstrating value in semi-supervised nonproliferation implementations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Sensorless Coil Detection Scheme based on Dead-Time Effect in Dynamic Wireless Power Transfer Systems

The detection of electric vehicles in dynamic wireless power transfer (DWPT) systems is important to reduce the standby losses and comply with the electromagnetic-field emission guidelines recommended by the International Commission for Non-Ionizing Radiation Protection. This paper discusses a novel sensorless coil detection scheme, which exploits the phenomenon of voltage-polarity reversal/notches caused by the dead-time effect in the full-bridge inverter. The variations in the system impedance and dead-time effects are collectively exploited to detect the receiver coil in the DWPT system. The proposed coil detection scheme is accomplished at low excitation voltage, which reduces the inverter standby losses. The theoretical analysis of the notch occurrence and open-loop simulation results are presented using a DWPT model developed in the piecewise linear electrical circuit simulation software.

Kavimandan, Utkarsh↗

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg∙cm -2 mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg∙cm -2 ) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg∙cm -2 correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg∙cm -2 (excluding negative values and outliers) and a range from 0 - 0.24 mg∙cm -2 , the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg∙cm -2 and less than 10% at 0.24 mg∙cm -2 . The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor.

air sampling↗

Pixel-Based Model For High Latitude Dust Detection

Dust has implications on the energy budget, ocean biodiversity, and economy at regional and global scales. Dust detection relies on spectral sensitivity at visible (RGB) and infrared wavelengths. Radiative properties of high latitude dust and the background surface albedo in these regions (>40°N, >40°S) complicate current dust detection methods. Leveraging supervised machine learning (ML) methods, we propose a new method accounting for regional differences of dust occurrence.

High latitude dust↗

Nonlinear coupling of electromagnetic and electron acoustic waves in multi-species degenerate astrophysical plasma

Nonlinear wave-coupling is studied in a multispecies degenerate astrophysical plasma consisting of two electron species (at different temperatures): a highly degenerate main component plus a smaller classical relativistic flow immersed in a static neutralizing ion background. It is shown that the high frequency electromagnetic waves through their strong nonlinear interactions with the electron-acoustic waves [sustained by a multielectron component (degenerate) plasma surrounding a compact astrophysical object] can scatter to lower frequencies so that the radiation observed faraway will be spectrally shifted downward. It is also shown that, under definite conditions, the electromagnetic waves could settle into stationary solitonic states. It is expected that the effects of such structures may persist as detectable signatures in forms of modulated micropulses in the radiation observed far away from the accreting compact object. Both these effects will advance our abilities to interpret the radiation coming out of the compact objects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BioSentinel: Developing a Space Radiation Biosensor

BioSentinel is an autonomous fully self-contained science mission that will conduct the first study of the biological response to space radiation outside low Earth orbit (LEO) in over 40 years. The 4-unit (4U) BioSentinel biosensor system, is housed within a 6-Unit (6U) spacecraft, and uses yeast cells in multiple independent microfluidic cards to detect and measure DNA damage that occurs in response to ambient space radiation. Cell growth and metabolic activity will be measured using a 3-color LED detection system and a metabolic indicator dye with a dedicated thermal control system per fluidic card.

Radiation biosensor↗