Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Liquid Air Combined Cycle TM for Power and Storage

Liquid Air Combined Cycle (LACC) is a hybrid liquid air energy storage (LAES) system combining energy storage with a combustion turbine to enable large-scale, long-duration energy storage (LDES) while reducing fuel intensity compared to the current state-of-the-art. The LACC technical approach employs proven equipment (cryogenic refrigeration, storage, tanks, pumps, gas turbines, exhaust heat recovery equipment, and turbines) to limit technical risk to a novel organic Rankine cycle (ORC), which was evaluated during this project and found to be feasible. Moreover, LACC storage is safe and relatively compact, to facilitate siting close to loads and within metropolitan regions. The air storage medium is freely available and eliminates supply chain constraints. LACC uses cryogenic air as a storage medium and a gas turbine as the source of heat to drive the discharge process. LACC is distinguished from other LAES technologies by several factors. The charge and discharge processes are decoupled so that cryogenic liquid air is the only storage medium. Other systems also store the higher temperature thermal energy from the liquefaction process in an additional medium. Subsequently, LACC focuses on maximization of the discharge energy and power. LACC also permits the use of commercially available cryogenic refrigeration and storage technologies to increase competition. This project identified product requirements to support market entry and commercialization of the LACC in modular units of approximately 117 MW, each drawing liquid air from customary cryogenic storage tanks capable of storing 75 GWh of dispatchable energy, more than pumped storage hydro or compressed air energy storage technologies. An economic analysis identified the specific liquid air consumption (quantity of liquid air per unit of discharge energy) as a critical parameter. Minimizing the air consumption reduces the specific capital cost ($\$ $/kW) for charging and discharging equipment by reducing the size of piping and turbomachinery. Likewise, the specific cost of energy capacity ($\$ $/kWh) is reduced by increasing the energy deliverable from a given size tank. The cycle was analyzed to identify the optimal equipment selection and operating conditions, which in turn were combined with quotes and cost estimates to calculate the cost of energy from an LACC system. A substantial effort was focused on the ORC, which draws low-temperature heat from the gas turbine exhaust and condenses at low temperature using the cryogenic liquid air as a heat sink. Alternative turbomachinery arrangements were evaluated for feasibility and cost. A technology maturation plan lays out a low-risk approach to development of the novel ORC components and demonstration of LACC technology at pilot scale.

25 ENERGY STORAGE↗

Development of Low-cost Magnetocaloric Materials (CRADA 446)

This is the final report for a TCF funded project, supported by the Hydrogen and Fuel Cell Technology Office. PNNL worked with GE&R, a domestic US company that manufactures magnetocaloric materials (MCM), for potential applications in magnetic refrigeration. The overall goal of this project was to develop an energy-efficient technique to shorten the annealing time of MCM, from days to hours, with the expected benefits of lower costs and shorter lead times. Success in this project will enable industry partner General Engineering & Research LLC (GE&R) to commercialize their high-performance MCM, in support of DOE-Fuel Cell Technology Office’s efforts to develop energy-efficient magnetic refrigeration technology (using MCM) for hydrogen liquefaction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Field and Laboratory Study to Characterize Fault Prevalence in Residential Comfort Systems

This report describes a project whose goal was to determine the prevalence of residential comfort system faults. The focus is on air conditioners and heat pumps, and on key faults that can occur during installation and have significant impacts on performance: (1) incorrect refrigerant charge level (undercharge or overcharge); (2) indoor coil airflow rate; (3) liquid line restrictions; (4) non-condensable gas in the refrigerant; and (5) duct leakage. In addition to quantifying fault prevalence, we collected metadata that could be studied to determine whether there are correlations that suggest drivers of fault prevalence, such as regional variations in practice, economic factors, climatic impacts, and others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ionic Liquids for Utilization of Waste Heat from Distributed Power Generation Systems

The objective of this research project was the development of ionic liquids to capture and utilize waste heat from distributed power generation systems. Ionic Liquids (ILs) are organic salts that are liquid at room temperature and they have the potential to make fundamental and far-reaching changes in the way we use energy. In particular, the focus of this project was fundamental research on the potential use of IL/CO2 mixtures in absorption-refrigeration systems. Such systems can provide cooling by utilizing waste heat from various sources, including distributed power generation. The basic objectives of the research were to design and synthesize ILs appropriate for the task, to measure and model thermophysical properties and phase behavior of ILs and IL/CO2 mixtures, and to model the performance of IL/CO2 absorption-refrigeration systems.

03 NATURAL GAS↗

Operational Performance Characterization of a Heat Pump System Utilizing Recycled Water as Heat Sink and Heat Source in a Cool and Dry Climate

The wastewater leaving from homes and businesses contains abundant low-grade energy, which can be utilized through heat pump technology to heat and cool buildings. Although the energy in the wastewater has been successfully utilized to condition buildings in other countries, it is barely utilized in the United States, until recently. In 2013, the Denver Museum of Nature & Science at Denver, the United States implemented a unique heat pump system that utilizes recycled wastewater from a municipal water system to cool and heat its 13,000 m 2 new addition. This recycled water heat pump (RWHP) system uses seven 105 kW (cooling capacity) modular water-to-water heat pumps (WWHPs). Each WWHP uses R-410A refrigerant, has two compressors, and can independently provide either 52 °C hot water (HW) or 7 °C chilled water (CHW) to the building. This paper presents performance characterization results of this RWHP system based on the measured data from December 2014 through August 2015. The annual energy consumption of the RWHP system was also calculated and compared with that of a baseline Heating, Ventilation, and Air Conditioning (HVAC) system which meets the minimum energy efficiencies that are allowed by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1-2013. The performance analysis results indicate that recycled water temperatures were favorable for effective operation of heat pumps. As a result, on an annual basis, the RWHP system avoided 50% of source energy consumption (resulting from reduction in natural gas consumption although electricity consumption was increased slightly), reduced CO 2 emissions by 41%, and saved 34% in energy costs as compared with the baseline system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Field Measurement of Central CO2 Heat Pump Water Heater for Multifamily Retrofit

Domestic hot water heating of multifamily buildings accounts for a substantial portion of the energy load of existing buildings. This load is made up of both the energy required to produce hot water and the energy needed to maintain the temperature of the heated water within a building’s distribution piping so that heat can be promptly delivered to building occupants as needed. Properly designed heat pump water heater (HPWH) systems have the ability to improve efficiency in both water heating and temperature control operations. Further, CO2 heat pump technology reflects a shift away from traditional refrigerants and toward refrigerants with low global warming potential (GWP). In this paper’s case study, a design consisting of multiple CO2 heat pump water heaters (commonly used in single-family homes) with a novel “swing tank” was proposed to meet the demand for domestic hot water heating and recirculation loop temperature maintenance. The proposed design was applied to the retrofit of a 60-unit, low-rise, multi-family building located in the Pacific Northwest of the United States. The purpose of this paper is to verify the performance of the system including the proposed “swing tank” in a centralized SHW system using CO2 HPWH. It also provides practical information and lessons learned from the retrofit project. Long-term monitoring data showed that the system had a coefficient of performance (COP) of three or greater and provided an average of 20 gallons of hot water per day per apartment. The results of this work indicate that residential-scale CO2 HPWH equipment and a “swing tank” design can efficiently provide domestic hot water heating and temperature maintenance for mid-sized multifamily buildings.

Banks, Adria↗

EC/LSS thermal control system study for the space shuttle

The results of a parametric weight analysis of heat rejection systems for the space shuttle orbiter are presented. Integrating the suborbital heat rejection system with the overall heat rejection system design and the possible use of a common system for both on-orbit and suborbital operations require an overall system and parametric analyses applicable to all mission phases. The concept of equivalent weights, with weight penalties assigned for power, induced aircraft drag and radiator area is used to determine weight estimates for the following candidate systems: vapor cycle refrigeration, gas cycle refrigeration, radiators (space and atmospheric convectors), expendable heat sinks, and ram air. The orbiter power penalty, ram air penalty, and radiator weight penalty are analyzed. The vapor compression system and an expendable fluid system utilizing a multifluid spraying flash evaporator are selected as the two most promising systems. These are used for maximum on-orbit heat rejection in combination with or as a supplement to a space radiator.

Howell, H. R.↗

The thermal system for an environmental chamber

The design of a cooling and heating system for obtaining temperatures in the range of -60 C to +120 C on a thermal shroud is described. The proposed temperature control uses mechanical refrigeration with Freon-22 as the primary refrigerant, methanol as the secondary coolant for low temperatures, and electrically heated ethylene glycol for high temperatures. The system is designed to give the following time-temperature characteristics: lowering the temperature from +30 C to -60 C in 1.5 hours; maintaining the temperature at -60 C for a period of 6 hours; heating from -60 C to +120 C in 3 hours; maintaining the temperature at +120 C for a period of 6 hours; and cooling from +120 C in 1.5 hours. A description of the system and its operation are given.

Srinivasan, K.↗

Shuttle freezer conceptual design

A conceptual design for a kit freezer for operation onboard shuttle was developed. The freezer features a self-contained unit which can be mounted in the orbiter crew compartment and is capable of storing food at launch and returning with medical samples. Packaging schemes were investigated to provide the optimum storage capacity with a minimum weight and volume penalty. Several types of refrigeration systems were evaluated to select one which would offer the most efficient performance and lowest hazard of safety to the crew. Detailed performance data on the selected, Stirling cycle principled refrigeration unit were developed to validate the feasibility of its application to this freezer. Thermal analyses were performed to determine the adequacy of the thermal insulation to maintain the desired storage temperature with the design cooling capacity. Stress analyses were made to insure the design structure integrity could be maintained over the shuttle flight regime. A proposed prototype freezer development plan is presented.

Proctor, B. W.↗

Food and medical sample freezer kit concept for Shuttle

A variety of food and storage of samples can be provided by a Space Shuttle Orbiter Freezer Kit. The proposed concept is an integrated package consisting of four -23 C (-10 F) storage compartments and a Stirling cycle refrigeration unit. The Stirling cycle mechanical refrigeration was selected over alternative systems for superior efficiency and safety. The trade-offs and a conceptual design of the system are presented.

Copeland, R. J.↗

Reduction of liquid hydrogen boiloff: Optimal reliquefaction system design and cost study

The refrigeration cycles investigated are referred to as Joule-Thomson cycles because they depend on the J-T effect to produce the low temperatures. Two basic competitive refrigeration cycles were evaluated. The first vents a portion of cold H2 gas to achieve the required precooling; the second uses LN2 for precooling. Both open loop and closed loop cycles were evaluated as well as combinations of venting to supplement the LN2 precooling. All cycles use a H2 compressor to achieve the desired high pressure (1325 psig). The heat compression was removed by cooling water. The high pressure H2 gas was cooled in counter flow heat exchangers by flowing cold H2 to the compressor. Further cooling was achieved for cycles using LN2 by passing H2 vapors through a LN2 heat exchanger. Finally, the high pressure H2 gas was expanded through a J-T valve where a portion of H2 was liquefied. The low pressure H2 gas flow back through the heat exchangers to the compressor is that portion not liquefied and makes up hydrogen gas from the dewar.

Source record↗

System for and method of freezing biological tissue

Biological tissue is frozen while a polyethylene bag placed in abutting relationship against opposed walls of a pair of heaters. The bag and tissue are cooled with refrigerating gas at a time programmed rate at least equal to the maximum cooling rate needed at any time during the freezing process. The temperature of the bag, and hence of the tissue, is compared with a time programmed desired value for the tissue temperature to derive an error indication. The heater is activated in response to the error indication so that the temperature of the tissue follows the desired value for the time programmed tissue temperature. The tissue is heated to compensate for excessive cooling of the tissue as a result of the cooling by the refrigerating gas. In response to the error signal, the heater is deactivated while the latent heat of fusion is being removed from the tissue while the tissue is changing phase from liquid to solid.

Williams, T. E.↗

Mass Driver Two - Cryogenic module

The cryogenic module of Mass Driver Two comprises a 3.25 inch (82.55 mm) OD bucket with two 44 kilo-ampere-turn coils made with .028 inch (.71 mm) diam niobium-titanium multi-filamentary cable in a copper matrix, impregnated with lead alloy for thermal inertia, as well as the service station to refrigerate, energize and eject the bucket. The station is housed in a six inch flanged pyrex cross which connects to the four inch pyrex tube of the mass driver itself. The bucket is refrigerated by being forced against a copper braid cradle attached to the bottom of a liquid helium reservoir which protrudes into the cross from above. The bucket is energized inductively by turning off two superconducting coils which are also attached to the helium reservoir, and which have maintained the correct flux linkage through the bucket coils during their cool-down through the critical temperature. Once charging is completed, the clamping pressure is released and the bucket is injected into the mass driver by means of two normal-conductor pulse coils surrounding the horizontal branches of the cross.

Fine, K.↗

Molecular absorption cryogenic cooler for liquid hydrogen propulsion systems

A light weight, long life molecular absorption cryogenic cooler (MACC) system is described which can use low temperature waste heat to provide cooling for liquid hydrogen propellant tanks for interplanetary spacecraft. Detailed tradeoff studies were made to evaluate the refrigeration system component interactions in order to minimize the mass of the spacecraft cooler system. Based on this analysis a refrigerator system mass of 31 kg is required to provide the .48 watts of cooling required by a 2.3 meter diameter liquid hydrogen tank.

Klein, G. A.↗

The effects of controls and controllable and storage loads on the performance of stand-alone photovoltaic systems

Stand-alone photovoltaic systems have been modeled and analyzed from sunlight in to consumer product out. By including the consumer product in the analysis, concepts such as 'product storage' (a storage tank for water or cold-plates for refrigeration) and loads controllable by the system controller have been added to the system analysis. From a controls analysis viewpoint, this adds state variables to the system. The result is that the system controller can make operating control decisions on the energy flow between these various system elements to optimize system performance and reduce system cost. The effects on system performance of various control schemes employing these concepts are presented. Analysis of water pumping and/or refrigeration systems show possible performance improvements of greater than 15% with the addition of controllable loads with product storage.

Cull, R. C.↗

Motorized Cyrogenic Valve

Remotely-controlled cryogenic valve operates over temperature range from room temperature to 2 K. Valve used in helium dilution refrigerators, cryostats and adiabatic-demagnetization refrigerators.

Salerno, L.↗

Tests of a 2-Stage, Axial-Flow, 2-Phase Turbine

A two phase flow turbine with two stages of axial flow impulse rotors was tested with three different working fluid mixtures at a shaft power of 30 kW. The turbine efficiency was 0.55 with nitrogen and water of 0.02 quality and 94 m/s velocity, 0.57 with Refrigerant 22 of 0.27 quality and 123 m/s velocity, and 0.30 with steam and water of 0.27 quality and 457 m/s velocity. The efficiencies with nitrogen and water and Refrigerant 22 were 86 percent of theoretical. At that fraction of theoretical, the efficiencies of optimized two phase turbines would be in the low 60 percent range with organic working fluids and in the mid 50 percent range with steam and water. The recommended turbine design is a two stage axial flow impulse turbine followed by a rotary separator for discharge of separate liquid and gas streams and recovery of liquid pressure.

Elliott, D. G.↗