Optimal Thermal Gradient for Flux Expulsion in 600°C Heat-treated CEBAF 12 GeV Upgrade Cavities

We will present results on measurement of flux expulsion in CEBAF 12 GeV upgrade cavities and original CEBAF cavities and the search for optimal thermal gradient for reducing the trapped flux in cavities installed in CEBAF linacs. Preliminary measurements of one C100 cavities has shown that a nearly perfect flux expulsion can be achieved at an optimal thermal gradient - a surprising result contrary to the expectation of zero flux expulsion for 600°C heat treated niobium cavities. These results could lead to a cost-effective path for improving the quality factor of cavities installed in CEBAF and ultimately saving accelerator operation cost.

Geng, R.↗

Recent development on nitrogen infusion work towards high Q and high gradient

A quality factor as high as 2 × 1010 at 1.5 GHz was achieved at a gradient of 35 MV/m by 800 °C annealing and N-infusion at 140 °C. A comparison of the field dependence of the surface resistance after N-infusion with a recent theoretical model that extends the calculation of the BCS surface resistance to high rf fields suggests an increase in the quasiparticles¿ relaxation time with increasing infusion temperature, which could be due to a decreasing density of subgap states. Nb coupons treated similarly showed the formation of thicker oxynitride layer on the surface beneath thin dielectric Nb2O5 layer. A plausible explanation for the improved Q0 is that the oxynitride layer on the Nb surface adds additional electron scattering within RF penetration depth.

Dhakal, P.↗

Crystallographic Characterization of Nb3Sn Coatings and N-Doped Niobium via EBSD and SIMS

Historically, niobium has been used as the superconducting material in SRF cavities. Due the high operational costs, other materials are currently being considered. Nb3Sn coatings have been investigated over the past several decades, motivated by potentially higher operating temperatures. More recently niobium has been doped with nitrogen to improve the quality factor (Q). Currently, a need for better understanding still exists for both mechanisms. EBSD has been shown to be a viable technique to determine the crystallographic orientation and the size of the Nb3Sn grains. The EBSD maps obtained show a bimodal distribution of grain sizes with smaller Nb3Sn grains found present near the Nb3Sn/Nb interface. In addition to the Nb3Sn coatings, N-doped niobium coupons were analyzed by EBSD and found that the coupon had preferred surface orientation. The EBSD analysis was found to be vital as specific grains could be targeted in SIMS to better understand the diffusion of nitrogen with respect to crystal orientation.

Angle, J. W.↗

Microwave Cavity Simulation Using Ansys HFSS

The design of microwave cavity detectors for axion dark matter research is often accomplished using advanced full-wave electromagnetic simulation software tools. These tools provide a cost-effective approach to evaluate a wide variety of cavity configurations, frequency tuning mechanisms, and conductive or dielectric materials and coatings. One simulation software package used for this application is Ansys High Frequency Structure Simulator (HFSS), which is based upon the well-established finite element method. HFSS includes numerous features useful for microwave cavity design such as parametric geometry modeling, adaptive meshing algorithm, curvilinear mesh elements, driven modal and eigenmode matrix solvers, and optimization algorithms. This paper describes the use of the HFSS software to simulate microwave cavities for axion haloscope detectors, with an example tutorial for a cylindrical cavity. Excellent agreement between the simulated and analytical results is shown for the resonant frequency, quality factor, and form factor.

Ansys HFSS, Cavity simulation, finite element mode↗

Growth and Properties of Vapor Diffused Nb3Sn Coating for Superconducting Radiofrequency Accelerator Cavity Applications

The desire to reduce construction and operating costs of future SRF accelerators motivates the search for higher-performing alternative materials. Nb3Sn (Tc ~ 18.3 K and Hsh ~ 425 mT) is the front runner. The tin vapor diffusion process is currently the technique of choice to produce promising Nb3Sn-coated cavities. Understanding Nb3Sn nucleation and growth in this process is essential to progress. Samples representing different stages of Nb3Sn formation have been produced and studied to elucidate the effects of nucleation, growth, process conditions, and impurities. Nb3Sn films with thickness from a few hundred nm up to ~15 µm were grown and characterized. The microscopic examination of samples suggests the mechanisms of thin film nucleation and growth. Broadly, nucleation deposits tin as a thin surface phase and, under some conditions, a few hundred nanometer sized particles as well. Conditions that impair nucleation promote the formation of defects, such as ?patches?, in subsequent coating growth. Analysis of coated samples is consistent with the model of Nb3Sn grown in which tin diffuses via grain boundaries to Nb3Sn-Nb interface, where the growth Nb3Sn into the niobium bulk takes place. Similar scaling laws are found for grain growth and layer thickness. Non-parabolic layer growth is consistent with significant grain growth, which reduces the number of Sn-transport channels. Examination of patchy region in Nb3Sn coating revealed it to be large single crystalline grains, pointing to impeded Nb3Sn layer growth due to low grain boundary density, resulting in a significantly thin coating in those areas. Examination of RF loss regions from a coated cavity, identified with a thermometry mapping system showed patchy regions and carbonus defects were associated with strong local field-dependent surface resistance. RF measurements of coated cavities were combined with material characterization of witness samples and coated-cavity cutouts to improve the coating process. Understanding obtained and applied to cavity coatings, resulted in single-cell Nb3Sn cavities with a quality factor of ~2 ×1010 up to 15 MV/m accelerating gradient at 4 K, without "Wuppertal" Q-slope. We have also produced Nb3Sn-coated CEBAF 5-cell cavities with accelerating gradients useful for accelerator cryomodules. This dissertation will discuss the genesis of the Nb3Sn coating in a typical tin vapor diffusion process, effects of different process parameters, and its consequences to the coating of single-cell and multi-cell SRF cavities.

Pudasaini, Uttar↗

Localization and reduction of superconducting quantum coherent circuit losses

Quantum sensing and computation can be realized with superconducting microwave circuits. Qubits are engineered quantum systems of capacitors and inductors with non-linear Josephson junctions. They operate in the single-excitation quantum regime, photons of $27 \mu$eV at 6.5 GHz. Quantum coherence is fundamentally limited by materials defects, in particular atomic-scale parasitic two-level systems (TLS) in amorphous dielectrics at circuit interfaces.[1] The electric fields driving oscillating charges in quantum circuits resonantly couple to TLS, producing phase noise and dissipation. We use coplanar niobium-on-silicon superconducting resonators to probe decoherence in quantum circuits. By selectively modifying interface dielectrics, we show that most TLS losses come from the silicon surface oxide, and most non-TLS losses are distributed throughout the niobium surface oxide. Through post-fabrication interface modification we reduced TLS losses by 85% and non-TLS losses by 72%, obtaining record single-photon resonator quality factors above 5 million and approaching a regime where non-TLS losses are dominant. [1]M\"uller, C., Cole, J. H. & Lisenfeld, J. Towards understanding two-level-systems in amorphous solids: insights from quantum circuits. Rep. Prog. Phys. 82, 124501 (2019)

Altoé, M Virginia P↗

Focusing transformers/filters in isotropic/anisotropic piezoelectrics

A focusing interdigital transducer (IDT) and corresponding single- and dual-port piezoelectric devices are disclosed. The focusing interdigital transducer, which generates Lamé acoustic waves, permits operation at significantly higher frequencies than those possible with traditional IDTs. The focusing IDT employs multiple arced fingers formed both above and below the piezoelectric layer to improve coupling efficiency by coupling through both the e31 and e33 piezoelectric coefficients to the piezoelectric layer. By optimizing both anchor design and location, acoustic wave losses are minimized, thereby improving the device's quality factor Q. Through proper bus design and selection of the number of IDT fingers, a device's impedance can be tuned for a given application. The focusing IDTs may be used in single-port filter devices and dual-port transformer devices. The single- and dual-port devices may operate at a single frequency, at two frequencies, or over a band of frequencies.

Siddiqui, Aleem↗

Qualifying AL-800 Garnet For The Fermilab Booster Perpendicular Biased 2nd Harmonic RF Cavity

Al-800 garnet was evaluated for the perpendicular biased 2nd harmonic cavity for the Fermilab Booster accelerator. A test apparatus was designed to evaluate the magnetic permeability and batch consistency of small witness samples of Al-800. Fully assembled AL-800 garnet rings were tested on the garnet ring test stand to measure the resonant frequency and quality factor of each ring. The garnet witness samples and assembled garnet rings showed acceptable consistency within the parameters set by the cavity design team. Based on the test results, AL-800 garnet was deemed suitable for use in the perpendicular biased 2nd harmonic cavity.

Kuharik, John C.↗

Searches for New Particles, Dark Matter, and Gravitational Waves with SRF Cavities

This is a Snowmass white paper on the utility of existing and future superconducting cavities to probe fundamental physics. Superconducting radio frequency (SRF) cavity technology has seen tremendous progress in the past decades, as a tool for accelerator science. With advances spear-headed by the SQMS center at Fermilab, they are now being brought to the quantum regime becoming a tool in quantum science thanks to the high degree of coherence. The same high quality factor can be leveraged in the search for new physics, including searches for new particles, dark matter, including the QCD axion, and gravitational waves. We survey some of the physics opportunities and the required directions of R&D. Given the already demonstrated integration of SRF cavities in large accelerator systems, this R&D may enable larger scale searches by dedicated experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of Electropolishing on Nitrogen Doped and Undoped Niobium Surfaces

Cold electropolishing (EP) of a nitrogen-doped (N-doped) niobium (Nb) superconducting RF (SRF) cavity was found to improve its quality factor. In order to understand the effect of EP temperature on N-doped and undoped surfaces, a systematic EP study was conducted with 2/0 N-doped and heat-treated Nb samples in a beaker. The Nb samples were electropolished at different surface temperatures ranging from 0 to 42 C. The results showed that the doped surface was susceptible to the sample temperature during EP. EP resulted in the surface pitting on the doped samples where the number density of pits increased at a higher temperature. The surface results were compared with the surface of cutouts from a 9-cell cavity which was 2/0 N-doped and electropolished. This paper shows de-tailed surface features of the N-doped and undoped Nb surfaces electropolished at different temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High quality superconducting Nb co-planar resonators on sapphire substrate

We present measurements and simulations of superconducting Nb co-planar waveguide resonators on sapphire substrate down to millikelvin temperature range with different readout powers. In the high temperature regime, we demonstrate that the Nb film residual surface resistance is comparable to that observed in the ultra-high quality, bulk Nb 3D superconducting radio frequency cavities while the resonator quality is dominated by the BCS thermally excited quasiparticles. At low temperature both the resonator quality factor and frequency can be well explained using the two-level system models. Through the energy participation ratio simulations, we find that the two-level system loss tangent is $\sim 10^{-2}$, which agrees quite well with similar studies performed on the Nb 3D cavities.

Zhu, S.↗

Experiments On A Conduction Cooled Superconducting Radio Frequency Cavity With Field Emission Cathode

To achieve Ampere-class electron beam accelerators the pulse delivery rate need to be much higher than the typical photo injector repetition rate of the order of a few kilohertz. We propose here an injector which can, in principle, generate electron bunches at the same rate as the operating RF frequency. A conduction-cooled superconducting radio frequency (SRF) cavity operating in the CW mode and housing a field emission element at its region of high axial electric field can be a viable method of generating high-repetition-rate electron bunches. In this paper, we report the development and experiments on a conduction-cooled Nb3Sn cavity with a niobium rod intended as a field emitter support. The initial experiments demonstrate 0.4 MV/m average accelerating gradient, which is equivalent of peak gradient of 3.2 MV/m. The measured RF cavity quality factor is 1.4 x 10$^8$ slightly above our goal. The achieved field gradient is limited by the relatively low input RF power and by the poor coupling between the external power supply and the RF cavity. With ideal coupling the field gradient can be as high as 0.6 MV/m still below our goal of about 1 MV/m.

43 PARTICLE ACCELERATORS↗

Multi-mode Analysis of Surface Losses in a Superconducting Microwave Resonator in High Magnetic Fields

This paper reports on a surface impedance measurement of a niobium titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to $10\,{\rm T}$). A novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple $TM$ cavity modes. The results confirm that quality factor degradation of a NbTi SRF cavity in a high magnetic field is primarily from surfaces perpendicular to the field (the cavity end caps), while parallel surface resistances (the walls) remain relatively constant. This result is encouraging for applications needing high Q cavities in strong magnetic fields, such as the Axion Dark Matter eXperiment (ADMX), because it opens the possibility of hybrid SRF cavity construction to replace conventional copper cavities.

43 PARTICLE ACCELERATORS↗

AMR Magnetic Sensors in Flux Expulsion Studies

Magnetic flux expulsion properties of the superconducting material such as bulk niobium, widely used for the radio-frequency cavity fabrication, substantially affect the performance characteristics of the cavities. The quality factor of the SRF resonators can be significantly compromised due to the presence of the trapped flux vortices causing additional RF energy losses in the material. Large number of experiments have been carried out by different research groups to establish the correlation of the flux trapping in niobium cavities with the presence of impurities in niobium as well as various surface treatment methods. Majority of these experiments utilize commercially available cryogenic fluxgate magnetic sensors to measure the field before and after the niobium transition to the superconducting state to quantify the amount of flux trapped. One disadvantage of the typically used fluxgates is the size of the sensing volume. As an example, the Barting-ton F and G type cryogenic fluxgates have a sensing core length of about 30mm, which is comparable to the curvature radius of the cavity walls and hence the magnetic field lines curvature radius after the expulsion. Thus, the measured field value needs to be corrected to account for the sensor effective averaging over the sensing volume. In case of the sharper geometries, for instance if the flux expulsion to be measured on the edge of the rectangular niobium flat sheet with a thickness of ~5mm, the use of the fluxgate would be impractical.

Netepenko, A.↗

Superconductivity device comprising a phononic crystal

The invention is directed to a device and method to engineer the superconducting transition width by suppressing the phonon populations responsible for the Cooper-pair decoherence below the superconducting transition temperature via phononic bandgap engineering. The device uses phononic crystals to engineer a phononic frequency gap that suppresses the decohering thermal phonon population just below the Cooper-frequency, and thus the normal conduction electron population. For example, such engineering can relax the cooling requirements for a variety of circuits yielding higher operational quality factors for superconducting electronics and interconnects.

El-Kady, Ihab Fathy↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

Mirror smooth superconducting RF cavities by mechanical polishing with minimal acid use

A new mechanical technique for polishing the inside surface of niobium superconducting RF (SRF) cavities has been developed. Mirror-like finishes, the smoothest observed in cavities so far, were produced after fine polishing, with < 15 nm RMS roughness over 1 mm2 scan area. This is an order of magnitude less than the typical roughness produced by electropolishing. The processing equipment has advantages of modest installed and operating costs, simple associated technology, and no large quantities of acutely toxic chemicals or special handling procedures. Cavity quality factors above 10 10 were maintained well above the 35 MV m-1 benchmark for electropolished cavities, and this was achieved with an intermediate finish not as smooth as the final polish. Repair of a weld defect, which is intrinsic to this process, was also demonstrated. These transformational aspects could enable a new SRF cavity processing paradigm for future large scale particle accelerators such as the International Linear Collider.

43 PARTICLE ACCELERATORS↗

3D superconducting radio-frequency resonators for quantum computing

Superconducting radiofrequency (SRF) technology is being used not only in discovery science programs and basic research but also for several applications that benefit society more directly. The advantage of superconducting resonators over those made of normal-conducting metal is their ability to store electromagnetic energy with much lower dissipation. The high quality factor and longer dissipation time provided by these superconducting resonators can deliver superior performance. Currently, the quantum processing architecture uses resonators and interconnecting circuits operating in the microwave regime with superconducting strip-line technology and low noise electronic devices for switching and communication. The performance of these devices can be enhanced by embedding them in 3D SRF cavity resonators to prolong the coherence time, which improves the utility of the device by reducing error rates and allowing more manipulations (calculations) before the quantum state decays. In this presentation, I will review the current technology and progress towards the three dimensional SRF cavities to enhance the coherence time.

Dhakal, Pashupati↗