Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Designing polymeric membranes with coordination chemistry for high-precision ion separations

State-of-the-art polymeric membranes are unable to perform the high-precision ion separations needed for technologies essential to a circular economy and clean energy future. Coordinative interactions are a mechanism to increase sorption of a target species into a membrane, but the effects of these interactions on membrane permeability and selectivity are poorly understood. We use a multilayered polymer membrane to assess how ion-membrane binding energies affect membrane permeability of similarly sized cations: Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , and Mg 2+ . We report that metals with higher binding energy to iminodiacetate groups of the polymer more selectively permeate through the membrane in multisalt solutions than single-salt solutions. In contrast, weaker binding species are precluded from diffusing into the polymer membrane, which leads to passage proportional to binding energy and independent of membrane thickness. Our findings demonstrate that selectivity of polymeric membranes can markedly increase by tailoring ion-membrane binding energy and minimizing membrane thickness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast dense DNA functionalization of quantum dots and rods for scalable 2D array fabrication with nanoscale precision

Scalable fabrication of two-dimensional (2D) arrays of quantum dots (QDs) and quantum rods (QRs) with nanoscale precision is required for numerous device applications. However, self-assembly–based fabrication of such arrays using DNA origami typically suffers from low yield due to inefficient QD and QR DNA functionalization. In addition, it is challenging to organize solution-assembled DNA origami arrays on 2D device substrates while maintaining their structural fidelity. Here, we reduced manufacturing time from a few days to a few minutes by preparing high-density DNA-conjugated QDs/QRs from organic solution using a dehydration and rehydration process. We used a surface-assisted large-scale assembly (SALSA) method to construct 2D origami lattices directly on solid substrates to template QD and QR 2D arrays with orientational control, with overall loading yields exceeding 90%. Our fabrication approach enables the scalable, high fidelity manufacturing of 2D addressable QDs and QRs with nanoscale orientational and spacing control for functional 2D photonic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-precision chemical quantum sensing in flowing monodisperse microdroplets

A method is presented for high-precision chemical detection that integrates quantum sensing with droplet microfluidics. Using nanodiamonds (ND) with fluorescent nitrogen-vacancy (NV) centers as quantum sensors, rapidly flowing microdroplets containing analyte molecules are analyzed. A noise-suppressed mode of optically detected magnetic resonance is enabled by pairing controllable flow with microwave control of NV electronic spins, to detect analyte-induced signals of a few hundredths of a percent of the ND fluorescence. Using this method, paramagnetic ions in droplets are detected with low limit-of-detection using small analyte volumes, with exceptional measurement stability over >10 3 s. In addition, these droplets are used as microconfinement chambers by co-encapsulating ND quantum sensors with various analytes such as single cells, suggesting wide-ranging applications including single-cell metabolomics and real-time intracellular measurements from bioreactors. Important advances are enabled by this work, including portable chemical testing devices, amplification-free chemical assays, and chemical imaging tools for probing reactions within microenvironments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision measurement of the neutral pion lifetime

The explicit breaking of the axial symmetry by quantum fluctuations gives rise to the so-called axial anomaly. This phenomenon is solely responsible for the decay of the neutral pion π0 into two photons (γγ), leading to its unusually short lifetime. Here, we precisely measured the decay width Γ of the π 0 → γγ process. The differential cross sections for π0 photoproduction at forward angles were measured on two targets, carbon-12 and silicon-28, yielding Γ(π 0 → γγ)=7.798±0.056(stat.)±0.109(syst.) eV, where stat. denotes the statistical uncertainty and syst. the systematic uncertainty. We combined the results of this and an earlier experiment to generate a weighted average of Γ(π 0 → γγ)=7.802±0.052(stat.)±0.105(syst.) eV. Our final result has a total uncertainty of 1.50% and confirms the prediction based on the chiral anomaly in quantum chromodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-precision measurement of the W boson mass with the CDF II detector

The mass of the W boson, a mediator of the weak force between elementary particles, is tightly constrained by the symmetries of the standard model of particle physics. The Higgs boson was the last missing component of the model. After observation of the Higgs boson, a measurement of the W boson mass provides a stringent test of the model. We measure the W boson mass, M W , using data corresponding to 8.8 inverse femtobarns of integrated luminosity collected in proton-antiproton collisions at a 1.96 tera–electron volt center-of-mass energy with the CDF II detector at the Fermilab Tevatron collider. A sample of approximately 4 million W boson candidates is used to obtain M W = 80,433.5 ± 6.4 stat ± 6.9 syst = 80,433.5 ± 9.4 MeV/c 2 , the precision of which exceeds that of all previous measurements combined (stat, statistical uncertainty; syst, systematic uncertainty; MeV, mega–electron volts; c, speed of light in a vacuum). This measurement is in significant tension with the standard model expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Carbon-doped metal oxide interfacial nanofilms for ultrafast and precise separation of molecules

Membranes with molecular-sized, high-density nanopores, which are stable under industrially relevant conditions, are needed to decrease energy consumption for separations. Interfacial polymerization has demonstrated its potential for large-scale production of organic membranes, such as polyamide desalination membranes. We report an analogous ultrafast interfacial process to generate inorganic, nanoporous carbon-doped metal oxide (CDTO) nanofilms for precise molecular separation. For a given pore size, these nanofilms have 2 to 10 times higher pore density (assuming the same tortuosity) than reported and commercial organic solvent nanofiltration membranes, yielding ultra-high solvent permeance, even if they are thicker. Owing to exceptional mechanical, chemical, and thermal stabilities, CDTO nanofilms with designable, rigid nanopores exhibited long-term stable and efficient organic separation under harsh conditions.

Science & Technology - Other Topics↗

On Precision Measurement of the Frequency of the 1{sup 1}S–2{sup 3}S Forbidden Transition of a Helium Atom

The possibility is demonstrated of a precision frequency measurement for the 1{sup 1}S{sub 0}−2{sup 3}S{sub 1} forbidden transition (at 62.6 nm) of a helium atom using the stimulated Raman scattering method. The 1{sup 1}S{sub 0} singlet state is the ground state of {sup 4}He, while the metastable 2{sup 3}S{sub 1} state has the lowest energy in the triplet part of the spectrum ({sup 4}He*). The transition has a very small natural width, which allows us to consider it as a possible reference for creation of a frequency standard in the vacuum ultraviolet region.

74 ATOMIC AND MOLECULAR PHYSICS↗

Crystal structure of the lead bromo-borate Pb{sub 2}[B{sub 5}O{sub 9}]Br from precision single-crystal X-ray diffraction data and the problem of optical nonlinearity of hilgardites

The structural features responsible for the high nonlinear optical activity of crystals of the hilgardite-like anhydrous bromo-borate Pb{sub 2}[B{sub 5}O{sub 9}]Br (space group Pnn2) are analyzed with the use of data obtained from two (precision and conventional) single-crystal X-ray diffraction experiments. The electron-density peaks associated with the stereochemically active lone electron pair are located in free space at two equally probable positions in the vicinity of the Pb(2) atom on the side of the two most distant atoms, Br(1) and Br(2). The stereochemical activity of two nonequivalent lead atoms in the crystal structure increases upon changing over from the Pb(1) atom to the Pb(2) atom. This is in agreement with the behavior of the lone electron pairs in the hilgardite-like hydrated borate Na{sub 0.5}Pb{sub 2}[B{sub 5}O{sub 9}](OH){sub 1.5} . 0.5H{sub 2}O and another nonlinear optical borate, namely, Pb{sub 2}[B{sub 4}O{sub 5}(OH){sub 4}](OH){sub 2} . H{sub 2}O, which is related to the compound BiB{sub 3}O{sub 6}. The most pronounced nonlinear optical properties of the lead bromo-borate Pb{sub 2}[B{sub 5}O{sub 9}]Br as compared to other orthorhombic hilgardites and lead borates are associated with the presence of highly polarized Pb-Br bonds. In this case, the electron density of the lone electron pair of the Pb(2) atom enhances the polarization effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-precision measurements of the compressibility of chalcogenide glasses at a hydrostatic pressure up to 9 GPa

The volumes of glassy germanium chalcogenides GeSe{sub 2}, GeS{sub 2}, Ge{sub 17}Se{sub 83}, and Ge{sub 8}Se{sub 92} are precisely measured at a hydrostatic pressure up to 8.5 GPa. The stoichiometric GeSe{sub 2} and GeS{sub 2} glasses exhibit elastic behavior in the pressure range up to 3 GPa, and their bulk modulus decreases at pressures higher than 2–2.5 GPa. At higher pressures, inelastic relaxation processes begin and their intensity is proportional to the logarithm of time. The relaxation rate for the GeSe{sub 2} glasses has a pronounced maximum at 3.5–4.5 GPa, which indicates the existence of several parallel structural transformation mechanisms. The nonstoichiometric glasses exhibit a diffuse transformation and inelastic behavior at pressures above 1–2 GPa. The maximum relaxation rate in these glasses is significantly lower than that in the stoichiometric GeSe{sub 2} glasses. All glasses are characterized by the “loss of memory” of history: after relaxation at a fixed pressure, the further increase in the pressure returns the volume to the compression curve obtained without a stop for relaxation. After pressure release, the residual densification in the stoichiometric glasses is about 7% and that in the Ge{sub 17}Se{sub 83} glasses is 1.5%. The volume of the Ge{sub 8}Se{sub 92} glass returns to its initial value within the limits of experimental error. As the pressure decreases, the effective bulk moduli of the Ge{sub 17}Se{sub 83} and Ge{sub 8}Se{sub 92} glasses coincide with the moduli after isobaric relaxation at the stage of increasing pressure, and the bulk modulus of the stoichiometric GeSe{sub 2} glass upon decreasing pressure noticeably exceeds the bulk modulus after isobaric relaxation at the stage of increasing pressure. Along with the reported data, our results can be used to draw conclusions regarding the diffuse transformations in glassy germanium chalcogenides during compression.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the Possibility of the Precise Test of Interatomic Interaction Potentials Using the Effect of Anomalous Light-Induced Drift

The spectral features of the velocity of light-induced drift (LID) of lithium atoms in a neon buffer gas have been theoretically studied using four known ab initio calculated interatomic interaction potentials for the Li–Ne system of colliding particles. The calculations with each of these four potentials predict a strong temperature dependence of the spectral shape of the LID signal of Li atoms in the Ne atmosphere in various temperature intervals. The results allow the high-precision test of the interatomic interaction potentials in experiments on anomalous LID.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision measurement of the rate of nuclear muon capture in the muonic hydrogen atom and the determination of the pseudoscalar form factor of the nucleon

The rate {Lambda}{sub S} of nuclear muon capture by a proton from the hyperfine singlet ground state of the {mu}p atom has been measured using a new experimental method based on a time-projection chamber operating in an ultrapure hydrogen gas at a pressure of 10 atm. The capture rate has been determined from the difference between the measured lifetime of the negative muon in hydrogen and the world average lifetime of the positive muon. The analysis of 10% of the collected statistics (2 x 10{sup 10}) of {mu}e decays yields the muon capture rate {Lambda}{sub S} = 725.0 {+-} 17.4 s{sup -1}, from which the pseudoscalar form factor of the nucleon, g{sub P}(q{sub c}{sup 2} = -0.88m{sub {mu}}{sup 2}) = 7.3 {+-} 1.1, is determined. The further analysis of the collected experimental data should improve the precision of this measurement by a factor of 3.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise model approximation of JINR (Dubna) data on nuclear level densities in the region 40 {<=} A {<=} 200 below B{sub n}

The experimental nuclear level density below the neutron binding energy B{sub n} in the mass region 40 {<=} A {<=} 200 is approximated to a high precision on the basis of the Strutinsky model combined with the assumption that the coefficient of collective enhancement of the level density for a given number of excited quasiparticles decreases exponentially with increasing excitation energy. This combination of model concepts makes it possible to reproduce faithfully not only the general trend revealed by the method developed at the Joint Institute for Nuclear Research (JINR, Dubna) in the change in the level density with increasing excitation energy in any nuclei but also the fine structure of this level density. Realistic experimental information about the change in the relationship between the densities of quasiparticle- and vibrational-type states was obtained for the first time for any nuclei virtually up to the neutron binding energy B{sub n}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise calculations of observables of polarized moller scattering: From JLAB to ILC energies

One-loop electroweak corrections to observables of the reaction e{sup -}e{sup -} {yields} e{sup -}e{sup -}({gamma}) were calculated over a broad range of energies: from conditions of the MOLLER experiment at the Thomas Jefferson Laboratory (JLab) to those of planned experiments at the International Linear Collider (ILC). The dependence of various contributions to the observable polarization asymmetry on various renormalization conditions was studied within the scheme of on-shell renormalization. The results were obtained by two methods: precisely, by applying the FeynArts, FormCalc, LoopTools, and Form computer codes, and approximately, with the aid of the asymptotic-estimation methods. The resulting compact formulas are absolutely free from nonphysical parameters and are convenient for deducing numerical estimates. It is shown that the total one-loop correction is independent of renormalization conditions and takes an identical value within different computational schemes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision of approximate Kramers formulas for the nuclear-fission rate in the presence of shell corrections

The precision of approximate Kramers formulas for the nuclear-fission rate in the presence of shell corrections in a quasistationary state is studied. The rates in question obtained analytically are compared with their numerical counterparts resulting from a dynamical simulation based on the Smoluchowski equation. It is shown that the integral Kramers formula is applicable even in the presence of shell corrections. As the excitation energy of the nucleus being considered decreases, the inaccuracy of this formula decreases monotonically, reaching 2% (inaccuracy of the dynamical simulation) in which case the dimensionless controlling parameter (entropy barrier) becomes greater than four. At small and intermediate values of this parameter, the accuracy of the integral Kramers formula is higher than the accuracy of the approximate Kramers formula obtained from it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New model of the cascade gamma decay of neutron resonances for practitioners: Basic concepts and attainable precision

A model-free extraction of level densities and radiative strength functions for cascade dipole gamma transitions that has been performed to date revealed the need for developing a new model of the deexcitation of compound states of nuclei having arbitrary masses and belonging to any type over a broad range of their excitations. Such a model should provide a practical means for determining thresholds for the breaking of nucleon Cooper pairs below the neutron binding energy, the relationship between the level densities for excitations of the quasiparticle and phonon types, and the emission widths for nuclear-reaction products in excited nuclei. From an analysis of data on the intensities of two-step cascades initiated by radiative thermal-neutron capture, it can be seen that the highest precision in describing available experimental spectra is reached upon taking into account the breaking of three to four Cooper pairs of nucleons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Measurements of High-Energy Cosmic Gamma-Ray Emission with the GAMMA-400 Gamma-Ray Telescope

The GAMMA-400 γ-ray telescope installed at the Russian space observatory is intended for precision measurements in the energy range of 20 MeV–1000 GeV of γ-ray emission (with the angular and energy resolutions several times better than that of current γ-ray telescopes) from discrete sources; measurement of the energy spectra of Galactic and extragalactic diffuse γ-ray emission; studies of γ-ray emission from the active Sun; and measurements of fluxes of γ-ray emission and electron–positron cosmicray component, which are probably associated with the annihilation or decay of dark-matter particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of the Precise Energy Calibration for Fast Neutron Spectrometers

Computational studies aimed at improving the accuracy of measurements performed using neutron generators with a tritium target were performed. A measurement design yielding an extremely narrow peak in the energy spectrum of DT neutrons was found. The presence of such a peak establishes the conditions for precise energy calibration of fast-neutron spectrometers.

43 PARTICLE ACCELERATORS↗

Various Applications of Precision Low-Energy Nuclear Electron Spectrometry in the KATRIN Tritium Neutrino Project

The energy scale of the main spectrometer in the KATRIN tritium project is required to remain stable within ±60 meV at an electron energy of 18.6 keV for two months in order to reach the intended sensitivity of 0.2 eV for the rest mass of the electron antineutrino. A natural source of reference electrons with an energy of 17824.3 ± 0.5 eV based on K -conversion electrons of the 32-keV nuclear γ-transition in {sup 83m}Kr from the decay of parent {sup 83}Rb was developed for this purpose using precision low-energy nuclear electron spectrometry. The spectroscopic parameters of {sup 83m}Kr/{sup 83}Rb sources fabricated by ion implantation into polycrystalline platinum foils were significantly better than the parameters of vacuum-deposited sources. A large-scale study of the influence of the physicochemical environment of atoms of different radioisotopes in various matrices of vacuum-deposited and implanted radioactive sources on the energy of emitted conversion and Auger electrons and on the structure of the corresponding energy spectra was conducted in the process. The possibility of application of photoelectron sources with a metallic converter as sources of reference electrons for the KATRIN project was also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗