Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Stabilizing the Power System in 2035 and Beyond: Evolving from Grid-Following to Grid-Forming Distributed Inverter Controllers (Final Technical Report)

Under existing grid operations, large synchronous generators provide sufficient rotational inertia to form a rigid backbone for the bulk power system. With photovoltaics (PV) forecasted to provide more than 600 GW of generation by 2050 under the U.S. Department of Energy’s SunShot Initiative objectives, however, it is clear that power electronic inverters will play a dominant role in future systems, and low-inertia stability must be ensured to maintain system reliability. Today, the risks to system stability can be observed on geographically small islands, such as Hawaii, which contain a relatively large amount of installed PV. These risks stem from a fundamental shortcoming of contemporary control strategies—existing inverter controllers cannot guarantee grid stability. Given that future power systems driven by sustainable resources will be characterized by low inertia, locations such as Hawaii provide a glimpse into the obstacles facing future power systems. Considering these challenges, the aim of this project was to develop and demonstrate distributed inverter controllers that enable the reliable control of low-inertia power systems with hundreds of gigawatts of integrated PV.

14 SOLAR ENERGY↗

Human-in-the-Loop Motion Control of a Two-DOF Hydraulic Backhoe Powered by the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic-Electric Architecture (HHEA) combines the respective power density and control advantages of hydraulic and electric actuation to save energy for off-road vehicles. It uses a set of selectable common pressure rails to transmit the majority of power and electric actuation to modulate that power. As it is critical that off-road vehicles can perform tasks dexterously and exactly as commanded by the operator, the switchings between discrete pressure rails pose a potential challenge for smooth and precise motion. A control strategy consisting of a backstepping nominal control and least norm transition control has previously been developed to address this issue. It has been tested on 1 degree of freedom (DOF) testbeds where known trajectories were able to be tracked precisely. This paper presents the implementation of the HHEA motion control strategy on a 2-DOF backhoe operated by a human operator via a 2-DOF joystick. Unlike previous studies, the duty cycle is unknown beforehand and the decision to change pressure rails is taken in real-time. The efficacy of the motion control strategy has been validated experimentally. Several strategies to improve the user interface: control in workspace coordinates, pressure feedback, and velocity field-based task specification, have also been implemented and demonstrated to make operating the multiple DOF, HHEA actuated machine more intuitive to novice operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preparing Distribution Utilities for the Future - Evolving Customer Consumption in Renewable Rich Grids: A Novel Analytical Framework

The research collaboration between NREL and BYPL focuses on the challenges caused by renewable integration into the power grid at large. Since the challenges and opportunities vary depending on the point of interconnection (distribution or transmission) the research team identified two tracks for research as listed below: 1. Power procurement - This research track focuses on the challenges and opportunities caused by GW scale renewable integration at the transmission level. Specifically, this track focuses on the contribution that utility-scale renewable energy procurement provides to distribution utilities, both from energy and capacity perspectives. In this track of research, utility customers are only considered as traditional (one-directional) consumers of energy. 2. Distributed energy resources - This research track focuses on the challenges and opportunities caused by many small-scale distributed renewable resource integrations at the distribution systems. At the power distribution level, distribution utilities may face not only new solar energy technologies, but also battery energy storage and electric vehicles as well. These three technologies (solar PV, battery energy storage, and electric vehicles) combined, pose unique challenges to distribution utilities. This track focuses on assessing the net-load evolution that distribution utilities observe as these emerging technologies make their way to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Introduction to the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS)

Deployment and capability of distributed energy resources (DER) in power systems is growing rapidly. These resources present an opportunity for low-cost provision of energy and grid services. The Federal Energy Regulatory Commission recently provided rulings to enable market participation of these distribution-connected resources, but the prevailing strategies for their management may not scale well to meet future needs. This paper introduces the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS) which was designed to address this need. In it we describe the architectural features of the approach, and a reference controls implementation employing a hierarchical coordination that includes stochastic optimization, model predictive control, and a simple real-time management scheme. Sample results from simulation show firm transmission-level service provision measured at the distribution substation.

grid architecture↗

5G Securely Energized and Resilient: (5G-SER) (Final Report)

NREL's work on 5G integration with physical power systems (versus simulated systems demonstrated in task 3) under 5G-Securely Energized and Resilient (5G-SER) achieved a major milestone in with the completion of Task 4 activities. After many months (6+) of planning and development along with scaling challenges along the way, a full 5G end-to-end network with physical hardware components (physical inverter, physical power panel, physical battery, etc.) was deployed in a containerized environment. In parallel, a distributed controls architecture for a microgrid powering 5G resources was also successfully modified from its previous instantiation for a simulated environment to work with these physical components. These accomplishments set the stage to use newly setup 5G technology with physical microgrid components to test the feasibility of 5G wireless with physical systems to enable resilient communications between controls and distributed solar and storage resources while exploring ways to configure 5G components to survive power disturbances. The results detailed in the report below show that even utilizing physical components, 5G wireless systems were able to provide resilient results that were similar to the results from the simulated environment Task 3).

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Introduction to the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS): Preprint

Deployment and capability of distributed energy resources (DER) in power systems is growing rapidly. These resources present an opportunity for low-cost provision of energy and grid services. The Federal Energy Regulatory Commission recently provided rulings to enable market participation of these distribution-connected resources, but the prevailing strategies for their management may not scale well to meet future needs. This paper introduces the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FASTDERMS) which was designed to address this need. In it we describe the architectural features of the approach, and a reference controls implementation employing a hierarchical coordination that includes stochastic optimization, model predictive control, and a simple real-time management scheme. Sample results from simulation show firm transmission-level service provision measured at the distribution substation.

DERMS↗

Lens Modeling of STRIDES Strongly Lensed Quasars Using Neural Posterior Estimation

Strongly lensed quasars can be used to constrain cosmological parameters through time-delay cosmography. Models of the lens masses are a necessary component of this analysis. To enable time-delay cosmography from a sample of $\mathcal{O}(10^3)$ lenses, which will soon become available from surveys like the Rubin Observatory’s Legacy Survey of Space and Time and the Euclid Wide Survey, we require fast and standardizable modeling techniques. To address this need, we apply neural posterior estimation (NPE) for modeling galaxy-scale strongly lensed quasars from the Strong Lensing Insights into the Dark Energy Survey (STRIDES) sample. NPE brings two advantages: speed and the ability to implicitly marginalize over nuisance parameters. We extend this method by employing sequential NPE to increase precision of mass model posteriors. We then fold individual lens models into a hierarchical Bayesian inference to recover the population distribution of lens mass parameters, accounting for out-of-distribution shift. After verifying our method using simulated analogs of the STRIDES lens sample, we apply our method to 14 Hubble Space Telescope single-filter observations. We find the population mean of the power-law elliptical mass distribution slope, γ lens , to be $\mathcal{M}_γ$ lens = 2.13 ± 0.06. Our result represents the first population-level constraint for these systems. This population-level inference from fully automated modeling is an important stepping stone toward cosmological inference with large samples of strongly lensed quasars.

79 ASTRONOMY AND ASTROPHYSICS↗

Navigating United States Standards and Regulation for Digital Energy Systems

This report provides an analysis of the U.S. standards and regulatory landscape for digital energy systems, focusing on cybersecurity, safety, and reliability requirements. It examines the interplay between federal mandates, state regulations, voluntary industry standards, and utility-specific policies, highlighting critical gaps between compliance and real-world risk mitigation. While NERC CIP standards enforce cybersecurity for Bulk Electric System assets, distribution-level infrastructure and emerging technologies often fall outside mandatory oversight, creating vulnerabilities. The report identifies systemic challenges such as reliance on self-attestation, uneven state adoption of safety codes, and lagging standards for advanced technologies like battery energy storage and inverter-based resources. Through a detailed gap analysis, it underscores the urgency of proactive risk-based approaches, independent verification, and strategic engagement with state and federal entities. Recommendations include adopting tiered security frameworks, strengthening procurement practices, and addressing emerging technology risks to ensure resilient and secure digital energy infrastructure. This guidance is intended for utilities, regulators, and stakeholders navigating compliance obligations and seeking to enhance cybersecurity and safety beyond minimum standards.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Design Considerations for Distributed Energy Resource Honeypots and Canaries

There are now over 2.5 million Distributed Energy Resource (DER) installations connected to the U.S. power system. These installations represent a major portion of American electricity critical infrastructure and a cyberattack on these assets in aggregate would significantly affect grid operations. Virtualized Operational Technology (OT) equipment has been shown to provide practitioners with situational awareness and better understanding of adversary tactics, techniques, and procedures (TTPs). Deploying synthetic DER devices as honeypots and canaries would open new avenues of operational defense, threat intelligence gathering, and empower DER owners and operators with new cyber-defense mechanisms against the growing intensity and sophistication of cyberattacks on OT systems. Well-designed DER canary field deployments would deceive adversaries and provide early-warning notifications of adversary presence and malicious activities on OT networks. In this report, we present progress to design a high-fidelity DER honeypot/canary prototype in a late-start Laboratory Directed Research and Development (LDRD) project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FERC order 2222 & DER policy and implementation report: May 2025

FERC and several states took action on distributed energy resource (DER) policy, the implementation of virtual power plants (VPPs), and FERC Order 2222 in the last several months. A summary of the actions is listed below.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Operations: The Evolution of Distributed Energy Resources [Guest Editorial]

Utilities around the world are experiencing change with the increasing digitalization of their systems and those of their customers. Efforts to decarbonize the electric power system have led to growth in renewable energy resources, particularly distributed energy resources (DERs), such as generation, storage, and flexible load, both in front of and behind the meter. As this change occurs in any given utility service area, new tools, such as advanced distribution management systems (ADMSs), are needed to manage utility operations, planning, and business issues, some of which are discussed here.

distributed energy resources, DER, decarbonize, re↗

Wave resource spatial and temporal variability dependence on WEC size

As the wave energy sector grows and looks to the Blue Economy for commercialization opportunities, there is a distinct and pressing need to clearly understand and quantify the coupled impacts of wave energy converter (WEC) size and wave resource characteristics on the annual energy production, spatial variability and temporal variability. Utilizing generic frequency domain representations of the Oscilla Power Triton WEC and spectral wave conditions at PacWave (Oregon), Los Angeles (California) and WETS (Hawaii), a series of interesting results emerge. Firstly, the ‘optimal’ WEC size, from an energy standpoint, is fundamentally dependent on the frequency distribution of the incoming wave variance density spectrum. Secondly, and from a seasonality perspective, the seasonal WEC energy generation doesn’t necessarily follow the seasonal distribution of gross wave power. Finally, from an hourly power variability perspective, a reduction in WEC size generally decreases variability. However, for each of the locations investigated, there appears to be a WEC size threshold; a threshold where further reducing WEC size results in increased power variability.

16 TIDAL AND WAVE POWER↗

Wave Resource Spatial and Temporal Variability Dependence on WEC Size

As the wave energy sector grows and looks to the Blue Economy for commercialization opportunities, there is a distinct and pressing need to clearly understand and quantify the coupled impacts of wave energy converter (WEC) size and wave resource characteristics on the annual energy production, spatial variability and temporal variability. Utilizing generic frequency domain representations of the Oscilla Power Triton WEC and spectral wave conditions at PacWave (Oregon), Los Angeles (California) and WETS (Hawaii), a series of interesting results emerge. Firstly, the 'optimal' WEC size, from an energy standpoint, is fundamentally dependent on the frequency distribution of the incoming wave variance density spectrum. Secondly, and from a seasonality perspective, the seasonal WEC energy generation doesn't necessarily follow the seasonal distribution of gross wave power. Finally, from an hourly power variability perspective, a reduction in WEC size generally decreases variability. However, for each of the locations investigated, there appears to be a WEC size threshold; a threshold where further reducing WEC size results in increased power variability.

blue economy↗

Power-transfer and fixed-point analysis of sawtooth simulations of a current-carrying stellarator

Power-transfer and fixed-point analysis of previous NIMROD simulations (Roberds et al. , Phys. Plasmas , vol. 23, issue 9, 2016, 092513) improved the understanding of the effect of 3D (non-axisymmetric equilibrium) magnetic fields on sawtooth oscillations in the Compact Toroidal Hybrid (CTH) experiment. Computing the locations of order-1 fixed points, their Greene's residues, and local values for the rotational transform results in a description of CTH sawteeth consistent with Kadomtsev's model. A power-transfer analysis quantifies the distribution of energy among toroidal Fourier modes and their nonlinear interactions. The Lorentz power transfer drives sawtooth growth, and it is unambiguously interpreted as the flow of energy from toroidal mode $n'$ to mode $n$ , catalysed by $\boldsymbol {B}_{n-n'}$ . It has been reported previously that the CTH sawtooth frequency increases with the 3D field strength. This is attributed to an increased growth rate of the internal kink that drives sawtooth oscillations. Here, 3D fields remove energy from the kink, eliminating the possibility that these fields are an additional energy source that drives growth. Instead, 3D fields catalyse energy transfer from large-to-small scales, where magnetic reconnection is stronger. It is proposed that this energy transfer increases the reconnection rate at small scales, which is consistent with the increased growth rate observed at higher 3D field strengths.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Introduction to the Special Section on Control and Management of Electric Power Systems With High Shares of Inverter-Based Resources

The growing interest in the integration of variable renewable energy (VRE) and distributed energy resources (DER) on both policy and economic grounds is driving the transformation of electric power systems. The significant deployment of VRE and DER can effectively displace the conventional synchronous generator-based power plants that for decades have been the foundation for power system generation and stability in electric power systems. Inverter-based resources (IBRs) introduce a high-level of uncertainty, variability, and complexity into the operation of electric power networks, and the transformation to IBRs raises a wide range of technical questions and operational challenges. The optimal coordination and control of these resources requires greater interoperability and necessitates significant upgrades of grid automation, including real-time monitoring.

distributed power generation↗

Impurity leakage and radiative cooling in the first nitrogen and neon seeding study in the closed DIII-D SAS configuration

A comparative study of nitrogen versus neon has been carried out to analyze the impact of the two radiative species on power dissipation, SOL impurity distribution, divertor and pedestal characteristics. The experimental results show that N remains compressed in the divertor, thereby providing high radiative losses without affecting the pedestal profiles and displacing carbon as dominant radiator. Neon, instead, radiates more upstream than N thus reducing the power flux through the separatrix leading to a reduced ELM frequency and compression in the divertor. A significant amount of neon is measured in the plasma core leading to a steeper density gradient. The different behavior between the two impurities is confirmed by SOLPS-ITER modeling which for the first time at DIII-D includes multiple impurity species and a treatment of full drifts, currents and neutral–neutral collisions. The impurity transport in the SOL is studied in terms of the parallel momentum balance showing that N is mostly retained in the divertor whereas Ne leaks out consistent with its higher ionization potential and longer mean free path. This is also in agreement with the enrichment factor calculations which indicate lower divertor enrichment for neon. The strong ionization source characterizing the SAS divertor causes a reversal of the main ions and impurity flows. The flow reversal together with plasma drifts and the effect of the thermal force contribute significantly in the shift of the impurity stagnation point affecting impurity leakage. This work provides a demonstration of the impurity leakage mechanism in a closed divertor structure and the consequent impact on pedestal. Since carbon is an intrinsic radiator at DIII-D, in this paper we have also demonstrated the different role of carbon in the N vs Ne seeded cases both in the experiments and in the numerical modeling. Here, carbon contributes more when neon seeding is injected compared to when nitrogen is used. Finally, the results highlight the importance of accompanying experimental studies with numerical modeling of plasma flows, drifts and ionization profile to determine the details of the SOL impurity transport as the latter may vary with changes in divertor regime and geometry. In the cases presented here, plasma drifts and flow reversal caused by high level of closure in the slot upper divertor at DIII-D play an important role in the underlined mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗