Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power System Operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Rectenna related atmospheric effects

Possible meteorological effects arising from the existence and operations of a solar power satellite (SPS) system rectenna are examined. Analysis and model simulations in some chosen site situations and meteorological conditions indicate that the meteorological effects of the construction and operation of a rectenna are small, particularly outside the boundary of the structure. From weather and climate points of view, installation of an SPS rectenna seems likely to have effects comparable with those due to other nonindustrial land use changes covering the same area. The absorption and scattering of microwave radiation in the troposphere would have negligible atmospheric effects.

Lee, J.↗

Terrestrial Applications of Extreme Environment Stirling Space Power Systems

NASA has been developing power systems capable of long-term operation in extreme environments such as the surface of Venus. This technology can use any external heat source to efficiently provide electrical power and cooling; and it is designed to be extremely efficient and reliable for extended space missions. Terrestrial applications include: use in electric hybrid vehicles; distributed home co-generation/cooling; and quiet recreational vehicle power generation. This technology can reduce environmental emissions, petroleum consumption, and noise while eliminating maintenance and environmental damage from automotive fluids such as oil lubricants and air conditioning coolant. This report will provide an overview of this new technology and its applications.

Dyson, Rodger. W.↗

On the Development of a Magnetically Vectored Variable ISP Plasma Rocket

The development of a Magnetically Vectored Variable I(sub sp) Plasma Rocket at the Advanced Space Propulsion Laboratory (ASPL) is in progress at NASA's Johnson Space Center. The facility is using a small, 3.2 m tandem mirror device to study the application of RF heated magnetically contained plasmas for space propulsion. The central cell radius is 0.1 m and fields of 0.2 T and 2 T are possible in the central and end-cell mirror sections, respectively. A magnetoplasmadynamic (MPD) injector has just been acquired and will be used along with other methods of plasma refueling. A 1 MW magnet power supply upgrade is being developed with full implementation by the Spring of 1997. Two microwave systems for discharge initiation and plasma heating at 2.45 GHz and 14.0 GHz, respectively, are in operation. Additionally, RF systems with 200 kW and 1 MW of power are being modified and conditioned for operation. The concept provides electrode-less operation and variable thrush'specific impulse at constant power (200 -30 N /5000-30,000 seconds at 10 MW with a 60% efficiency). Optimization for speed or payload are possible with the same engine, giving the rocket great flexibility. Missions to Mars in 90 days are described, and missions to Pluto are under study.

Feliciano, Enectali Figueroa↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2020

This report presents an enhanced performance evaluation of emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2020 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2020. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • HPCS EDG FTS failure probability • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTS failure probability • EPS EDG FTLR failure probability • EPS EDG unavailability • EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2022

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2022 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2022. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: (1) HPCS EDG FTS failure probability, (2) EPS and HPCS EDG frequency of start demands (demands per reactor year), and (3) EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: (1) EPS EDG FTS failure probability, (2) EPS EDG FTLR failure probability, (3) EPS EDG unavailability, and (4) EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2024

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2024 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2024. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands • EPS and HPCS EDG frequency of run>1H hours. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTR>1H failure rate • EPS EDG unreliability • EPS and HPCS EDG frequency of FTR>1H events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and evaluation of a fault-tolerant multiprocessor (FTMP) computer

The design, development, and testing of FTMP hardware and software for use in advanced NASA vehicles are described in three previously published reports prepared for NASA. Consideration is given to the overall FTMP architecture; the system bus; the regional design and operation of processor, slave, clock-generation, and power systems; and the FTMP executive, facilities, acceptance-test/diagnostic, applications, and support softwar. Also included are a summary of test procedures and results and an executive summary characterizing the system, the reliability and availability models, and the overall performance.

Smith, T. B., III↗

ARC disruption physics and strategy

Commonwealth Fusion Systems (CFS) plans to operate a tokamak power plant called ARC in the early 2030s. Tokamak plasmas have stability limits that, if crossed, lead to a rapid termination of the plasma, referred to as a disruption. Disruptions pose a melt risk to the first wall resulting from thermal and non-thermal particle heat fluxes, and an electromagnetic loading risk on all metal components within the equilibrium coils. A comprehensive set of models is used herein to provide an assessment of both mitigated and unmitigated ARC disruption loads. A preliminary massive gas injection system is baselined and a runaway electron mitigation coil option is proposed to close possible gaps in the baseline. It is predicted that all ARC disruption loads are within a factor of 2 of the disruption loads in SPARC, a tokamak presently under construction by CFS, and therefore SPARC provides an opportunity to calibrate models, test solutions and inform the design of ARC. The goal for ARC is disruption-free operation, however, the pragmatic design target is to withstand one mitigated disruption per day, and to restart the plasma following mitigation in tens of seconds without interrupting the power output. Unmitigated disruptions must be rare, and experience with unmitigated disruption impacts in SPARC will better define what rare means. The implications of this strategy for plasma disruptivity and disruption prediction are discussed, and operating the ARC scenario on SPARC is expected to refine the ARC final design and operational plan.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fuel Cell Power Plant Initiative: Solid Oxide Fuel Cell/Logistics Fuel Processor 27 kWe Power System Demonstration for ARPA - Volume 1

This report describes the successful testing of a 27 kWe Solid Oxide Fuel Cell (SOFC) generator fueled by natural gas and/or a fuel gas produced by a brassboard logistics fuel preprocessor (LFP). The test period began on May 24, 1995 and ended on February 26, 1996 with the successful completion of all program requirements and objectives. During this time period, this power system produced 118.2 MWh of electric power. No degradation of the generator's performance was measured after 5582 accumulated hours of operation on these fuels: local natural gas - 3261 hours, jet fuel reformate gas - 766 hours, and diesel fuel reformate gas - 1555 hours. This SOFC generator was thermally cycled from full operating temperature to room temperature and back to operating temperature six times, because of failures of support system components and the occasional loss of test site power, without measurable cell degradation. Numerous outages of the LFP did not interrupt the generator's operation because the fuel control system quickly switched to local natural gas when an alarm indicated that the LFP reformate fuel supply had been interrupted. The report presents the measured electrical performance of the generator on all three fuel types and notes the small differences due to fuel type. Operational difficulties due to component failures are well documented even though they did not affect the overall excellent performance of this SOFC power generator. The final two appendices describe in detail the LFP design and the operating history of the tested brassboard LFP.

Veyo, S.E.↗

System Study: Isolation Condenser 1998-2022

This report presents an unreliability evaluation of the isolation condenser (ISO) system at three U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from calendar year 1998–2022 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the ISO results.

99 GENERAL AND MISCELLANEOUS↗

Integrating Control Methods and Digital Twins for Advanced Nuclear Reactors

Advanced nuclear reactors offer new capabilities such as the ability to adapt to variable energy demand, operate autonomously with remote supervision, be deployable in rural locations, be compact in size, afford lower power ratings, and rely on novel techniques for increased operational safety. However, realizing these capabilities requires intelligent control systems that can track changing power demands and make autonomous decisions based on these demands. The unique aspects of advanced reactors (e.g., strict regulatory requirements, harsh operating environments, high consequences, highly coupled dynamics, evolving knowledge, and limited operating histories) directly impact the design and deployment of control systems for these reactors. The present work identifies and evaluates these aspects so as to develop a set of control system requirements to guide future research and development. To meet these requirements, a layered control system approach is proposed that integrates digital twins with different control paradigms. This work aims to demonstrate how different methods interface with enabling solutions, and to identify any gaps that need to be researched.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-String Integration Test Measurements of the NEXT Ion Engine Plume

Measurements were made of a 40 cm ion-thruster plume as part of the single-string-integration-test (SSIT) activity of Phase I of the NASA's Evolutionary Xenon Thruster (NEXT) project. The NEXT ion engine incorporates design improvements that extend NSTAR power levels and efficiencies. During SSIT, an engineering model (EM2) 40 cm engine was operated using an advanced xenon propellant system in combination with either a GRC power console or advanced power processing unit. Integral goals of the single-string phase were to characterize engine performance over the full input power range and to detail thruster operation within the specification of the NEXT throttle table. Plume diagnostics measurements of relative Xe(+) and Xe(++) currents were made using near-field and far-field ExB probes. Planar geometry faraday probes were used to obtain beam current density profiles. This paper reports on the characterization of the EM2 plume over a range of SSIT operating conditions, first with the advanced propellant management system teamed with the GRC power console and then with the power-processing unit.

Snyder, Aaron↗

Laser-powered MHD generators for space application

Magnetohydrodynamic (MHD) energy conversion systems of the pulsed laser-supported detonation (LSD) wave, plasma MHD, and liquid-metal MHD (LMMHD) types are assessed for their potential as space-based laser-to-electrical power converters. These systems offer several advantages as energy converters relative to the present chemical, nuclear, and solar devices, including high conversion efficiency, simple design, high-temperature operation, high power density, and high reliability. Of these systems, the Brayton cycle liquid-metal MHD system appears to be the most attractive. The LMMHD technology base is well established for terrestrial applications, particularly with regard to the generator, mixer, and other system components. However, further research is required to extend this technology base to space applications and to establish the technology required to couple the laser energy into the system most efficiently. Continued research on each of the three system types is recommended.

Jalufka, N. W.↗

Storage Futures Study: The Four Phases of Storage Deployment: A Framework for the Expanding Role of Storage in the U.S. Power System

This report is one in a series of NREL’s Storage Futures Study (SFS) publications. The SFS is a multiyear research project that explores the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. The research findings and supporting data will be published as a series of publications. The table on the next page lists the planned publications and specific research topics they will examine under the SFS. This report, the first in the SFS series, explores the roles and opportunities for new, cost-competitive stationary energy storage with a conceptual framework based on four phases of current and potential future storage deployment, and presents a value proposition for energy storage that could result in substantial new cost-effective deployments. This conceptual framework provides a broader context for consideration of the later reports in the series, including the detailed results of the modeling and analysis of power system evolution scenarios and their operational implications

25 ENERGY STORAGE↗

Distinct Dynamics of Lithium Intercalation and Plating on Graphite Anode for Li‐Ion Batteries in eVTOL Applications

In the absence of viable high-energy-density battery alternatives, lithium-ion (Li-ion) batteries remain essential for enabling electric vertical take-off and landing (eVTOL) platforms in advanced air mobility. Unlike Li-ion batteries used in electric vehicles and portable electronics, eVTOL battery systems operate under distinct high-power demands, which necessitate an independent assessment of material degradation mechanisms. This study presents a case analysis of graphite anode evolution under high-power cycling conditions. The findings reveal lithium entrapment within graphite particles, potentially resulting from incomplete Li-ion de-intercalation during a high-rate discharge event that is characteristic of eVTOL take-off and landing. This phenomenon leads to a progressive reduction in graphite-specific capacity and, over time, promotes lithium metal plating on the anode. Notably, the Li-metal plating observed in this study differs from that associated with fast-charging conditions, as it is primarily governed by concentration polarization-induced overpotential in the latter case. In conclusion, these findings highlight the inherent challenges of utilizing graphite in high-power Li-ion battery applications and elucidate the unique degradation mechanisms that arise due to the sluggish reaction kinetics of Li-ion intercalation and de-intercalation within graphite.

Li plating↗

Cross-Layered Distributed Data-Driven Framework for Enhanced Smart Grid Cyber-Physical Security

Smart Grid (SG) research and development has drawn much attention from academia, industry and government due to the great impact it will have on society, economics and the environment. Securing the SG is a considerably significant challenge due the increased dependency on communication networks to assist in physical process control, exposing them to various cyber-threats. In addition to attacks that change measurement values using False Data Injection (FDI) techniques, attacks on the communication network may disrupt the power system's real-time operation by intercepting messages, or by flooding the communication channels with unnecessary data. Addressing these attacks requires a cross-layer approach. In this paper a cross-layered strategy is presented, called Cross-Layer Ensemble CorrDet with Adaptive Statistics(CECD-AS), which integrates the detection of faulty SG measurement data as well as inconsistent network inter-arrival times and transmission delays for more reliable and accurate anomaly detection and attack interpretation. Numerical results show that CECD-AS can detect multiple False Data Injections, Denial of Service (DoS) and Man In The Middle (MITM) attacks with a high F1-score compared to current approaches that only use SG measurement data for detection such as the traditional physics-based State Estimation, Ensemble CorrDet with Adaptive Statistics strategy and other machine learning classification-based detection schemes.

cyber-physical security↗

A parametric SPICE model for the simulation of spark gap switches

The use of SPICE-based software for the simulation of pulsed power systems—even large complex systems—has become commonplace in the pulsed power community. This is in contrast to earlier work in the field that relied on specially developed simulation codes such as Sandia’s Screamer or the Navy Research Lab’s Bertha, which natively incorporated models for common pulsed power components such as spark gap switches. Unlike these programs, SPICE programs provide a simple and familiar user interface and wide availability. However, SPICE programs do not include realistic models for key pulsed power circuit devices—including the spark gap switch. While simple switch models do exist in SPICE programs, these can only crudely approximate the behavior of a spark gap. This effort focuses on developing an SPICE circuit model for a gas-filled spark gap switch that is physically realistic while being simple enough to permit simulations to run in reasonable times on typical personal computers. Detailed information is provided for implementation in two common versions of SPICE: LTspice and Orcad PSPICE. Adaptation to other SPICE programs is possible with minimal modification. The model is intended as a design tool that uses physical parameters as inputs to connect it directly to the development of useable pulsed power systems. Data collected from the operation of a high-pressure pulsed-charged switch and a complete 12-stage Marx generator have been used to demonstrate the implementation and accuracy of the model over a wide range of parameters.

Pouncey, J. Cameron (ORCID:0000000153500816)↗