Measurement of the neutron charge radius and the role of its constituents

The neutron is a cornerstone in our depiction of the visible universe. Despite the neutron zero-net electric charge, the asymmetric distribution of the positively- (up) and negatively-charged (down) quarks, a result of the complex quark-gluon dynamics, lead to a negative value for its squared charge radius, $\langle r^2_n\rangle$. The precise measurement of the neutron’s charge radius thus emerges as an essential part of unraveling its structure. Here we report on a $\langle r^2_n\rangle$ measurement, based on the extraction of the neutron electric form factor, $G^n_E$, at low four-momentum transfer squared (Q 2 ) by exploiting the long known connection between the N → Δ quadrupole transitions and the neutron electric form factor. Our result, $\langle r^2_n\rangle$=-0.110±0.008(fm 2 ), addresses long standing unresolved discrepancies in the $\langle r^2_n\rangle$ determination. The dynamics of the strong nuclear force can be viewed through the precise picture of the neutron’s constituent distributions that result into the non-zero $\langle r^2_n\rangle$ value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ZAM Modeling Study to Support the Tank Closure Cesium Removal (TCCR) 1A Unit

Currently at the Savannah River Site (SRS), the Tank Closure Cesium Removal (TCCR) is an “at-tank” process designed to remove cesium from aqueous tank waste. Cesium will be removed by ion exchange using the engineered IONSIV® R9120 form of Crystalline Silicotitanate (CST) media. The current TCCR design has two columns online in a lead-lag configuration to optimize media usage and achieve the target decontamination. Once the lead column is saturated with cesium, it will be removed from service, the lag column will rotate into the lead position, and a new column with fresh ion-exchange media will be placed into the lag position. The TCCR process for cesium removal from Tank 10H is detailed in X-SOW-H- 00002. Demonstration of the system began in early calendar year 2019 with two batches of salt solution generated by dissolving saltcake in Tank 10H, followed by processing of these batches through the TCCR system. A third TCCR Tank 10H dissolved saltcake batch is scheduled for processing soon. Upon completion of the demonstration with Tank 10H dissolved saltcake, Tank 9H salt solution will be transferred to Tank 10H and subsequently processed through the TCCR unit with new CST media (referred to as R9120-B 30x60) added to new IX columns. The TCCR processing campaign of Tank 9H salt solution is referred to as TCCR-1A .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-of-Flight Energy Measurements With BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighbouring Beam Position Monitors (BPMs). This report discusses implementation of such a procedure at the PIP-II H- linac being constructed at Fermilab. The case when the flight time between BPMs is longer than the period of BPM frequency is considered in more detail. When absolute BPM phase calibration is not available, the BPM phase information can be used to track deviations of the beam energy from the de-sired value. Such energy deviation parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander V. [Fermilab] (ORCID:00000001↗

Thermal analysis of Bridgman-Stockbarger growth

A thermal analysis of a cylindrical HgCdTe sample in a Bridgman-Stockbarger crystal growth configuration was conducted with emphasis on the thermal profile, interface shape and position, and the thermal gradients at the liquid-solid interface. Alloys of HgTe and CdTe with compositions approximating 20 percent CdTe, 80 percent HgTe were used. This composition results in a bandgap suited for the detection of 10.6 micron CO2 radiation. The sensitivity of the sample thermal characteristics to important growth parameters, such as thermal diffusivities, thermal conductivities, furnace temperature profile, ampoule dimensions, and growth velocity was assessed. Numerical techniques and associated computational models necessary to analyze the heat transfer process within the sample and the Bridgman-Stockbarger boundary conditions were developed. This thermal analysis mode was programmed in FORTRAN V, and is currently operational on the MSFC Univac 1100 system.

Knopf, F. W.↗

An experimental investigation of surface pressure measurements on an advanced winged entry vehicle at Mach 10

Surface pressure measurements have been made at Mach 10 in air on an instrumented 0.006-scale model of an advanced (control configured) winged entry vehicle. The tests were conducted in the Langley Continuous Flow Hypersonic Tunnel. Data were obtained at 83 surface pressure stations, which include locations on the lower and upper surface centerlines, spanwise positions along the lower and upper surfaces of the wing, the lower surface of the body flap, and radial locations on the fuselage. Data were obtained for angles of attack ranging from zero to 40 deg, sideslip angles of -2 deg to +5 deg, Reynolds numbers of 0.5, 1.0, and 2.0 million per foot, and body-flap deflections of zero, 10, and 20 deg. Test conditions and orifice locations were chosen to correspond directly with those for the heat transfer measurements previously reported on the same configuration. Comparison of windward symmetry plane data with predictions based upon an approximate engineering method was found to yield reasonable agreement for angles of attack from 20 to 40 deg. The leeward surface pressure data were observed to be roughly an order of magnitude lower than the corresponding windward data. At low angles of attack, regions of high pressure were noted on the windward wing surface. The result is attributed to vortical action or shock impingement. High pressures were also measured on the deflected body flap, a critical region for this type of vehicle. Reynolds number effects were found to be insignificant.

Wurster, K. E.↗

Multiple sensor multifrequency eddy current monitor for solidification and growth

A compact cylindrical multisensor eddy current measuring system with integral furnace was develop to monitor II-VI crystal growth to provide interfacial information, solutal segregation, and conductivities of the growth materials. The use of an array of sensors surrounding the furnace element allows one to monitor the volume of interest. Coupling these data with inverse multifrequency analysis allows radial conductivity profiles to be generated at each sensor position. These outputs were incorporated to control the processes within the melt volume. The standard eddy current system functions with materials whose electric conductivities are as low as 2E2 Mhos/m. A need was seen to extend the measurement range to poorly conducting media so the unit was modified to allow measurement of materials conductivities 4 order of magnitude lower and bulk dielectric properties. Typically these included submicron thick films and semiinsulating GaAs. This system was used to monitor complex heat transfer in grey bodies as well as semiconductor and metallic solidification.

Wallace, John↗

Simulation of space measurements of vegetation canopy bidirectional reflectance factors

A vegetation canopy receives both monodirectional and scattered radiation which is then reflected back into the atmosphere according to its bidirectional reflectance distribution function (BRDF). Remote measurements are typically the angular and spectral distributions of radiations exiting the atmosphere. The evaluation of vegetation canopy bidirectional reflectance factors requires a numerical solution of the canopy radiative transfer equation. A horizontally homogeneous vegetation canopy, of finite physical depth, filled densely with small leaves and bounded by a flat Lambertian ground surface is considered. The canopy is illuminated spatially uniformly by monodirectional radiation. The scattered intensity distribution emerging at the top of the canopy in all directions in the upper hemisphere is evaluated. The magnitude, sign and angular distribution of atmospheric effects are wavelength specific and depend on the composition of the atmosphere. The net atmospheric effect is positive (negative) at the red (near-infrared) wavelength due to strong scattering (absorption) in the atmosphere. The angular distribution of these effects is bowl-shaped. Thus, off-nadir remote observations, especially at shorter wavelengths, are most affected by atmospheric perturbations.

Myneni, R. B.↗

NASA/DOD Aerospace Knowledge Diffusion Research Project. Report 35: The use of computer networks in aerospace engineering

This research used survey research to explore and describe the use of computer networks by aerospace engineers. The study population included 2000 randomly selected U.S. aerospace engineers and scientists who subscribed to Aerospace Engineering. A total of 950 usable questionnaires were received by the cutoff date of July 1994. Study results contribute to existing knowledge about both computer network use and the nature of engineering work and communication. We found that 74 percent of mail survey respondents personally used computer networks. Electronic mail, file transfer, and remote login were the most widely used applications. Networks were used less often than face-to-face interactions in performing work tasks, but about equally with reading and telephone conversations, and more often than mail or fax. Network use was associated with a range of technical, organizational, and personal factors: lack of compatibility across systems, cost, inadequate access and training, and unwillingness to embrace new technologies and modes of work appear to discourage network use. The greatest positive impacts from networking appear to be increases in the amount of accurate and timely information available, better exchange of ideas across organizational boundaries, and enhanced work flexibility, efficiency, and quality. Involvement with classified or proprietary data and type of organizational structure did not distinguish network users from nonusers. The findings can be used by people involved in the design and implementation of networks in engineering communities to inform the development of more effective networking systems, services, and policies.

Bishop, Ann P.↗

MXER Simulation Study (Appendix A)

In this study, we consider the dynamics of a spinning tether system in an elliptical orbit in application to the Momentum Exchange Electrodynamic Reboost system. Momentum exchange tether systems have been studied in a variety of applications since Hans Moravec's early publication. It has recently been suggested that momentum exchange systems can be enhanced with electrodynamic reboost between payload transfers. The Momentum Exchange Electrodynamic Reboost system (MXER) has a projected tether span of up to 100 km, and spins rapidly with a period of 6-7 min. It is placed in an orbit with a low perigee of about 400 km and a high apogee of about 8000 km. To capture a payload at a perigee rendezvous, within a window of a few seconds, the motion of the system has to be predicted with very high precision, having acceptable position errors on the order of 1 m. While this level of precision is routinely achieved today for conventional (non-tethered) satellites, it is much more difficult to achieve for a 100 km long flexible tether system. It is the goal of this study to investigate theoretical aspects of the dynamics and offer a practical approach to high precision dynamic modeling of a typical momentum exchange tether system.

Levin, E. M.↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents computational fluid dynamics (CFD) models with conjugate heat transfer that are used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34-liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, and wall temperature. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface.

Computational Fluid Dynamics↗

Deciphering Reaction Mechanisms of Molecular Proton Reduction Catalysts with Cyclic Voltammetry: Kinetic vs Thermodynamic Control

The kinetics and thermodynamics of elementary reaction steps involved in the catalytic reduction of protons to hydrogen define the reaction landscape for catalysis. The mechanisms can differ in the order of the elementary proton transfer, electron transfer, and bond-forming steps and can be further differentiated by the sites at which protons and electrons localize. Access to fully elucidated mechanistic, kinetic, and thermochemical details of molecular catalysts is crucial to facilitate the development of new catalysts that operate with optimal efficiency, selectivity, and durability. The mechanism by which a catalyst operates, as well as the kinetics and thermodynamics associated with the individual steps, can often be accessed through electroanalytical studies. Here, this Account details the application of cyclic voltammetry to interrogate reaction mechanisms and quantify the kinetics and thermodynamics of elementary reaction steps for a series of molecular catalysts that mediate electrochemical proton reduction. I distinguish the limiting scenarios wherein a catalyst operates under kinetic control vs thermodynamic control, with a focus on detecting how cyclic voltammetry features shift with proton source strength and concentration, as well as scan rate. For systems that operate under kinetic control, catalytic currents are observed at, or slightly positive toward, the formal potential for the redox process that triggers catalysis. Under thermodynamic control, catalytic responses shift as a function of the proton source pKa and effective pH of the solution. After drawing this distinction, we introduce the appropriate voltammetry experiments and accompanying analytical expressions for extracting key metrics from the data. To illustrate analytical strategies to quantify elementary reaction steps of catalysts operating under kinetic control, I describe our studies of proton reduction catalysts Co(dmgBF 2 ) 2 (CH 3 CN) 2 (dmgBF 2 = difluoroboryl-dimethylglyoxime) and [Ni(P 2 Ph N 2 Ph ) 2 ] 2+ (P 2 Ph N 2 Ph = 1,5-phenyl-3,7-phenyl-1,5-diaza-3,7-diphosphacyclooctane). Here, peak shift analysis, foot-of-the-wave analysis, and plateau current analysis are applied to data sets wherein voltammetric response are recorded as a function of catalyst concentration, proton source concentration, proton source strength, and scan rate to quantify rate constants for elementary proton transfer and bond-forming steps in a catalytic cycle. Further, the case study of [Ni(P 2 Ph N 2 Ph ) 2 ] 2+ illustrates how complementary spectroscopic methods can bolster the mechanistic assignment. Collectively, these two studies showcase how detailed mechanistic studies inform on rate-limiting elementary steps in catalysis and other key processes underpinning catalysis. Second, I present analytical strategies to interrogate catalysts operating under thermodynamic control, centered on the case study of [Ni II (P 2 Ph N 2 Bn ) 2 ] 2+ (P 2 Ph N 2 Bn = 1,5-dibenzyl-3,7-diphenyl-1,5-diaza-3,7-diphosphacyclooctane). Here, the application of nonaqueous Pourbaix theory to extract thermodynamic information is introduced, and the construction of a coupled Pourbaix diagram is detailed. This study identifies ligand-based protonation as the key process that places catalysis under thermodynamic control and influences the reaction mechanism. Together, the work detailed in this Account showcases the utility of electroanalytical methods to disentangle complex reaction mechanisms and extract key thermochemical and kinetic parameters for elementary steps of catalysis. Through detailed presentation of the key analytical expressions that underpin these analyses, this Account seeks to facilitate the adoption of cyclic voltammetry by the community to fully extract kinetic, thermochemical, and mechanistic information on electrochemical small-molecule activation.

catalysts↗

One Electron Multiple Proton Transfer in Model Organic Donor–Acceptor Systems: Implications for High-Frequency EPR

EPR spectroscopy is an important spectroscopic method for identification and characterization of radical species involved in many biological reactions. The tyrosyl radical is one of the most studied amino acid radical intermediates in biology. Often in conjunction with histidine residues, it is involved in many fundamental biological electron and proton transfer processes, such as in the water oxidation in photosystem II. As biological processes are typically extremely complicated and hard to control, molecular bio-mimetic model complexes are often used to clarify the mechanisms of the biological reactions. In this work, we present theoretical calculations to investigate the sensitivity of magnetic resonance parameters to proton-coupled electron transfer events, as well as conformational substates of the molecular constructs which mimic the tyrosine-histidine (Tyr-His) pairs found in a large variety of proteins. Upon oxidation of the phenol, the Tyr analog, these complexes can perform not only one-electron one-proton transfer (EPT), but also one-electron two-proton transfers (E2PT). It is shown that in aprotic environment the g X -components of the electronicg-tensor are extremely sensitive to the first proton transfer from the phenoxyl oxygen to the imidazole nitrogen (EPT product), leading to a significant increase of the g X -value of up to 0.003, but are not sensitive to the second proton transfer (E2PT). In the latter case, the change of the g X -value is much smaller (ca. 0.0001), which is too small to be distinguished even by high-frequency EPR. The 14 N hyperfine values are also too similar to allow differentiation between the different protonation states in EPT and E2PT. The magnetic resonance parameters were also calculated as a function of the rotation angles around single bonds. It was demonstrated that rotation of the phenoxyl group results in large positive changes (> 0.001) in the g X -values. Analysis of the data reveals that the main source of these changes is related to the strength of the H-bond between phenoxyl oxygen and the proton(s) on N 1 and N 2 positions of the imidazole.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Superradiance and Directional Exciton Migration in Metal–Organic Frameworks

Crystalline metal–organic frameworks (MOFs) are promising synthetic analogues of photosynthetic light-harvesting complexes (LHCs). The precise assembly of linkers (organic chromophores) around the topology-defined pores offers the evolution of unique photophysical behaviors that are reminiscence of LHCs. These include MOF excited states with photoabsorbed energy that is spatially dispersed over multiple linkers defining the molecular excitons. The multilinker molecular excitons display superradiance–a hallmark of coupled oscillators seen in LHCs–with radiative rate constant (k rad ) exceeding that of a single linker. Our theoretical model and experimental results on three zirconium MOFs, namely, PCN-222(Zn), NU-1000, and SIU-100, with similar topology but varying linkers suggest that the size of such molecular excitons depends on the electronic symmetry of the linker. This multilinker exciton model effectively predicts the energy transfer rate constant; corresponding single-step exciton hopping time, ranging from a few picoseconds in SIU-100 and NU-1000 to a few hundreds of picoseconds in PCN-222(Zn), matches well with the experimental data. The model also predicts the anisotropy of exciton displacement with preferential migration along the crystallographic c-axis. Overall, these findings establish various missing links defining the exciton size and dynamics in MOF-assembled linkers. Furthermore, the understandings will provide design principles, especially, positioning the catalysts or electrode relative to the linker orientation for low-density solar energy conversion systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-of-Flight energy measurements with BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighboring Beam Position Monitors (BPMs). This report presents estimations on implementation of such a procedure at PIP-II H- linac being constructed at Fermilab. In part, the case when the flight time between BPMs is larger than the period of BPM frequency is considered in detail. When the absolute BPM phase calibration is not available, the BPM phase information can be used to trace deviations of the beam energy from the desired value. Such “energy deviation” parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander [Fermilab] (ORCID:00000001501↗

COLD-SAT orbital experiment configured for Atlas launch

The design and requirements for the proposed cryogenic on-orbit liquid depot storage, acquisition, and transfer (COLD-SAT) satellite experiment, which is to be launched by Atlas I, are examined. The COLD-SAT experiments are categorized as class I and II; class I involves technology related to space transportation missions and class II represents alternative fluid management operations and data. The hardware for the COLD-SAT experiments consists of three hydrogen tanks contained in the experimental module; the experimental module is connected to a three-axis-controlled spacecraft bus, and thrusters are positioned on the forward and aft ends of the spacecraft and on the cylindrical portion of the experimental module. The components and systems of the experiment module and the types of experiments that can be conducted in each tank are described. Diagrams of the spacecraft configuration are provided.

Shuster, J. R.↗

NASA Tech Briefs, September 2003

Topics include: Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask; Three-Dimensional Venturi Sensor for Measuring Extreme Winds; Swarms of Micron-Sized Sensors; Monitoring Volcanoes by Use of Air-Dropped Sensor Packages; Capacitive Sensors for Measuring Masses of Cryogenic Fluids; UHF Microstrip Antenna Array for Synthetic- Aperture Radar; Multimode Broad-Band Patch Antennas; 164-GHz MMIC HEMT Frequency Doubler; GPS Position and Heading Circuitry for Ships; Software for Managing Parametric Studies; Software Aids Visualization of Computed Unsteady Flow; Software for Testing Electroactive Structural Components; Advanced Software for Analysis of High-Speed Rolling-Element Bearings; Web Program for Development of GUIs for Cluster Computers; XML-Based Generator of C++ Code for Integration With GUIs; Oxide Protective Coats for Ir/Re Rocket Combustion Chambers; Simplified Waterproofing of Aerogels; Improved Thermal-Insulation Systems for Low Temperatures; Device for Automated Cutting and Transfer of Plant Shoots; Extension of Liouville Formalism to Postinstability Dynamics; Advances in Thrust-Based Emergency Control of an Airplane; Ultrasonic/Sonic Mechanisms for Drilling and Coring; Exercise Device Would Exert Selectable Constant Resistance; Improved Apparatus for Measuring Distance Between Axles; Six Classes of Diffraction-Based Optoelectronic Instruments; Modernizing Fortran 77 Legacy Codes; Active State Model for Autonomous Systems; Shields for Enhanced Protection Against High-Speed Debris; Scaling of Two-Phase Flows to Partial-Earth Gravity; Neutral-Axis Springs for Thin-Wall Integral Boom Hinges.

Source record↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction Using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗