Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Characteristics of STP Pre-2004 Archived KE Basin Sludge Samples Before and After Re-Jarring in the RPL - April 2012

This report describes results of work performed in the Shielded Analytical Laboratory (SAL) at the Pacific Northwest National Laboratory’s (PNNL) Radiochemical Processing Laboratory (RPL) with archive K East (KE) Basin sludge samples obtained before the year 2004, with some of them composited and initially characterized five years ago (Delegard et al. 2011). The previously performed testing included the physical properties determinations for selected samples (settled and particle densities, water and solids concentrations), the pH, as well as identification of crystalline phases by X-ray diffractometry (XRD) for selected samples. Another objective of the previous characterization and testing campaign was to transfer some sludge composites and individual samples into new storage containers to overcome the embrittlement effect which develops in original glass containers as a result of extended exposure to high radiation fields and which increases probability of sample loss.

K Basin↗

Development of a Raman Spectroscopy Technique to Detect Alternate Transportation Fuel Hydrocarbon Intermediates in Complex Combustion Environments

Spontaneous Raman spectra for important hydrocarbon fuels and combustion intermediates were recorded over a range of low-to-moderate flame temperatures using the multiscalar measurement facility located at Sandia/CA. Recorded spectra were extrapolated to higher flame temperatures and then converted into empirical spectral libraries that can readily be incorporated into existing post-processing analysis models that account for crosstalk from overlapping hydrocarbon channel signal. Performance testing of the developed libraries and reduction methods was conducted through an examination of results from well-characterized laminar reference flames, and was found to provide good agreement. The diagnostic development allows for temporally and spatially resolved flame measurements of speciated hydrocarbon concentrations whose parent is more chemically complex than methane. Such data are needed to validate increasingly complex flame simulations.

Ekoto, Isaac W.↗

In-Tank Elutriation Test Report And Independent Assessment

The Department of Energy (DOE) Office of Environmental Management (EM) funded Technology Development and Deployment (TDD) to solve technical problems associated with waste tank closure for sites such as Hanford Site and Savannah River Site (SRS). One of the tasks supported by this funding at Savannah River National Laboratory (SRNL) and Pacific Northwest Laboratory (PNNL) was In-Tank Elutriation. Elutriation is the process whereby physical separation occurs based on particle size and density. This report satisfies the first phase of Task WP_1.3.1.1 In-Tank Elutriation, which is to assess the feasibility of this method of separation in waste tanks at Hanford Site and SRS. This report includes an analysis of scoping tests performed in the Engineering Development Laboratory of SRNL, analysis of Hanford's inadvertent elutriation, the viability of separation methods such as elutriation and hydrocyclones and recommendations for a path forward.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Device Oriented Project Controller

This proposal is directed at the issue of developing control systems for very large HEP projects. A de-facto standard in accelerator control is the Experimental Physics and Industrial Control System (EPICS), which has been applied successfully to many physics projects. EPICS is a channel based system that requires that each channel of each device be configured and controlled. In Phase I, the feasibility of a device oriented extension to the distributed channel database was demonstrated by prototyping a device aware version of an EPICS I/O controller that functions with the current version of the channel access communication protocol. Extensions have been made to the grammar to define the database. Only a multi-stage position controller with limit switches was developed in the demonstration, but the grammar should support a full range of functional record types. In phase II, a full set of record types will be developed to support all existing record types, a set of process control functions for closed loop control, and support for experimental beam line control. A tool to configure these records will be developed. A communication protocol will be developed or extensions will be made to Channel Access to support introspection of components of a device. Performance bench marks will be made on both communication protocol and the database. After these records and performance tests are under way, a second of the grammar will be undertaken.

43 PARTICLE ACCELERATORS↗

2011 Groundwater Monitoring and Inspection Report Gnome-Coach Site, New Mexico

Gnome-Coach was the site of a 3-kiloton underground nuclear test in 1961. Surface and subsurface contamination resulted from the underground nuclear testing, post-test drilling, and groundwater tracer test performed at the site. The State of New Mexico is currently proceeding with a conditional certificate of completion for the surface. As for the subsurface, monitoring activities that include hydraulic head monitoring and groundwater sampling of the wells onsite are conducted as part of the annual site inspection. These activities were conducted on January 19, 2011. The site roads, monitoring well heads, and the monument at surface ground zero were observed as being in good condition at the time of the site inspection. An evaluation of the hydraulic head data obtained from the site indicates that water levels in wells USGS-4 and USGS-8 appear to respond to the on/off cycling of the dedicated pump in well USGS-1 and that water levels in wells LRL-7 and DD-1 increased during this annual monitoring period. Analytical results obtained from the sampling indicate that concentrations of tritium, strontium-90, and cesium-137 were consistent with concentrations from historical sampling events.

54 ENVIRONMENTAL SCIENCES↗

Technetium Removal Using Tc-Goethite Coprecipitation

This report describes the results from laboratory tests performed at Pacific Northwest National Laboratory for the U.S. Department of Energy (DOE) EM-31 Support Program (EMSP) subtask, “Low temperature waste forms coupled with technetium removal using an alternative immobilization process such as Fe(II) treated-goethite precipitation” to increase our understanding of 99Tc long-term stability in goethite mineral form and the process that controls the 99Tc(VII) reduction and removal by the final Fe (oxy)hydroxide forms. The overall objectives of this task were to 1) evaluate the transformation process of Fe (oxy)hydroxide solids to the more crystalline goethite (α-FeOOH) mineral for 99 Tc removal and 2) determine the mechanism that limits 99 Tc(IV) reoxidation in Fe(II)-treated 99 Tc-goethite mineral and 3) evaluate whether there is a long-term 99 Tcoxidation state change for Tc sequestered in the iron solids.

Goethite↗

Measure Guideline: Combustion Safety for Natural Draft Appliances Using Indoor Air

This Measure Guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate Measure Guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combustion Safety for Appliances Using Indoor Air (Fact Sheet)

This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mo-99 Stripping Results and Column Designs for Mini-Medical Isotope Production System (MIPS)

Results from the column tests performed by using small volumes of irradiated solutions as tracers for depleted uranium (DU) solutions containing stable molybdenum (Mo) as Na 2 MoO 4 forced us to investigate the stripping parameters needed to obtain full Mo recovery. In an effort to optimize the stripping conditions, several column runs were done by using either 1 M NaOH or NH 4 OH as the stripping agent at different velocities. Overall, we obtained very inconsistent results that suggest stripping velocity does not affect Mo recovery as much as originally believed. In addition, we generated 0.1 M HNO 3 breakthrough curves after each run to determine if the performance of the column was changing. Future experiments will utilize columns packed with fresh sorbent after each run. The column designs for the mini-MIPS 5-liter (L) and 20-L experiments employed data obtained from using several different S80 columns at different loading, washing, and stripping velocities. Data were input into the VERSE code, and plant-scale column designs were generated. The mini-MIPS column designs and parameters are a direct downscale of the plant operation, where full Mo adsorption and recovery are expected.

Youker, Amanda J.↗

An Investigation of the Applicability and Limitations of the ORNL Expanded Plug Test

The expanded plug test technique for measuring the circumferential tensile properties of irradiated nuclear fuel cladding was developed at Oak Ridge National Laboratory (ORNL) and has been used successfully in several applications. The primary advantage of this technique over other procedures is its simplicity for application in the complex hot cell environment. During the development stage, efforts were made to both qualify the technique as much as possible regarding its experimental application and to develop and validate the data reduction procedures. However, since this is a new technique, the technical community is cautious in adopting a procedure that has not been fully vetted. The purpose of this effort was to address several baseline issues regarding the applicability of the technique and the precision of the use of experimental expanded ring load-deformation data to calculate material circumferential stress-strain properties. The tests performed, in conjunction with the developed data reduction procedures, demonstrate good reliability in the prediction of ring material stress-strain behavior for several materials of widely different strengths.

tensile, nuclear fuel cladding↗

LAMMPS strong scaling performance optimization on Blue Gene/Q

LAMMPS "Large-scale Atomic/Molecular Massively Parallel Simulator" is an open-source molecular dynamics package from Sandia National Laboratories. Significant performance improvements in strong-scaling and time-to-solution for this application on IBM's Blue Gene/Q have been achieved through computational optimizations of the OpenMP versions of the short-range Lennard-Jones term of the CHARMM force field and the long-range Coulombic interaction implemented with the PPPM (particle-particle-particle mesh) algorithm, enhanced by runtime parameter settings controlling thread utilization. Additionally, MPI communication performance improvements were made to the PPPM calculation by re-engineering the parallel 3D FFT to use MPICH collectives instead of point-to-point. Performance testing was done using an 8.4-million atom simulation scaling up to 16 racks on the Mira system at Argonne Leadership Computing Facility (ALCF). Speedups resulting from this effort were in some cases over 2x.

Coffman, Paul↗

Investigation of HNO2 Production in Solvent Extraction Organic Phases

This document is a letter report that was prepared to meet FCR&D level 4 milestone M4FT-14IN0304054, “Investigate HNO2 production in solvent extraction organic phases.” This work was carried out under the auspices of the Fundamental Radiation Chemistry FCR&D work package. This document reports on an initial tests performed to follow HNO2 formation in reference flowsheet relevant organic phases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design & Implementation of MACSio

We are proposing to develop “MACSio” (pronounced “max-ee-oh”), a Multi-purpose, Application-Centric, Scalable I/O proxy application. It is being proposed to fill a long existing void in co-design proxy applications that allow for I/O performance testing and evaluation of tradeoffs in data model interfaces and parallel I/O paradigms for multi-physics, HPC applications. Two key design features of MACSio will set it apart from existing I/O benchmarking tools. The first is the level of abstraction (LOA) at which MACSio is being designed to operate. The second is the degree of flexibility MACSio is being designed to provide in driving an HPC I/O workload through parameterized, user-defined data objects and a variety of parallel I/O paradigms and I/O interfaces. Combined, these features will allow MACSio to closely mimic I/O workloads for a wide variety of real applications and, in particular, multi-physics applications where data object distribution and composition vary dramatically both within and across parallel tasks. These data objects can then be marshaled using one or more I/O interfaces and parallel I/O paradigms, allowing for direct comparisons of software interfaces, parallel I/O paradigms, and filesystem technologies with the same set of customizable data objects.

97 MATHEMATICS AND COMPUTING↗

Causal Analysis For Occurrence Report: OR NA-SS-SNL-2000-2015-0005 Unexpected Type of Failure of Thermal Battery

On 6/26/2015 at approximately 1445 in 894/136, a pulse thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following an electrical performance test that is routinely conducted on thermal batteries. A dedicated tester for this operation was used and it ran the test until the nominal 28-volt output of the battery had dropped to 5 volts, usually indicative of the battery being spent and safe enough to move. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another primary containment box within the same room; initial indications are that the battery experienced an over-pressurization failure which led to the battery's base plate being expelled and the operator receiving a non-recordable injury (bruising to the palm of the hand) from the pressure of the expulsion. The operator was wearing the prescribed PPE (safety glasses and high temperature glove) and was handling the battery appropriately with an open, flat hand. Pictures of the scene are below.

25 ENERGY STORAGE↗

GrayQb TM Single-Faced Version 2 (SF2) Open Environment Test Report (Rev. 1)

This report details the design upgrades incorporated into the new version of the GrayQb TM SF2 device and the characterization testing of this upgraded device. Results from controlled characterization testing in the Savannah River National Laboratory (SRNL) R&D Engineering Imaging and Radiation Lab (IRL) and the Savannah River Site (SRS) Health Physics Instrument Calibration Laboratory (HPICL) is presented, as well as results from the open environment field testing performed in the E-Area Low Level Waste Storage Area. Resultant images presented in this report were generated using the SRNL developed Radiation Analyzer (RAzer TM ) software program which overlays the radiation contour images onto the visual image of the location being surveyed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commercial Building Motor Protection Response Report

When voltages recover, motors may immediately reenergize and reaccelerate, or delay for a few minutes, or stay stalled. The estimated motor response is given for both the voltage sag magnitude and voltage sag duration. These response estimates are based on experience and available test data. Good data is available for voltage sag response for many components such as relays and contactors, but little data is available for both voltage sag and recovery response. The tables in Appendix A include data from recent voltage sag and recovery tests performed by SCE and BPA on air conditioners and energy management systems. The response of the motor can vary greatly depending on the type of protection and control. The time duration for the voltage sag consists of those times that are of interest for bulk power system modelers.

24 POWER TRANSMISSION AND DISTRIBUTION↗